Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BOLOMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Increased accuracy and signal-to-noise ratio through recent improvements in infra-red video bolometer fabrication and calibration

The infra-red video bolometer (IRVB) is a diagnostic equipped with an infra-red camera that measures the total radiated power in thousands of lines of sight within a large field of view. Recently validated in MAST-U [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)], it offers a high spatial resolution map of the radiated power in the divertor region, where large gradients are expected. The IRVB’s sensing element comprises a thin layer of high Z absorbing material, typically platinum, usually coated with carbon to reduce reflections [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)].Here, the possibility of using a relatively inert material such as titanium, is explored that can be produced in layers up to 1 μm compared to 2.5 μm for Pt and then coat it with Pt of the desired thickness (0.3 μm per side here) and carbon. This leads to a higher temperature signal (about 3 times) and better spatial resolution (about 4 times), resulting in higher accuracy in the measured power [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)]. This assembly is also expected to improve foil uniformity, as the Pt layer is obtained via deposition rather than mechanical processes [Mukai et al., Rev. Sci. Instrum. 87, 2014 (2016)].Given its multi-material composition, measuring the thermal properties of the foil assembly is vital. Various methods using a calibrated laser as a heat source have been developed, analyzing the temperature profile shape [Sano et al., Plasma and Fusion Res. 7, 2405039 (2012)] and [Mukai et al., Rev. Sci. Instrum. 89, 10E114 (2018)] or fitting the calculated laser power for different intensities and frequencies [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)]. Here, a simpler approach is presented, which relies on analyzing the separate components of the foil heat equation for a single laser exposure in a given area. This can then be iterated over the entire foil to capture local deviations.

Magnetic Fusion Energy↗

Developing a robust sensor for infrared imaging bolometers

A new type of large area sensor for infrared imaging bolometers has been developed. It replaces the thin and fragile free-standing metal foils, which typically have been used, with a multi-layer coated sapphire (or diamond) substrate. Sapphire is transparent to mid-infrared wavelengths, is robust against transients, and can be thick enough to even be the vacuum window. The primary radiation absorber is still a thin deposited metal layer, but now it is partially insulated from the supporting sapphire substrate by a black (carbon-based) layer, which also acts as a blackbody remitter. Test results indicate 6× more noise equivalent power density (estimated NEPD = 23 W/m 2 at 5 ms camera exposure time, foil temperature decay time 60 ms) for a 2 μm gold-coated sapphire disk compared to estimated NEP = 4 W/m 2 at 1.8 ms exposure time, with foil decay time 420 ms, for a nominal 2.5 μm thick platinum-free-standing foil.

47 OTHER INSTRUMENTATION↗

Fiber-Optic Bolometer and Calorimeter Arrays for Magnetically Confined Plasmas

Bolometers measure the plasma radiation and provide essential diagnostic information both for safe, sustainable operation of magnetic-confinement fusion (MCF) devices and for study of the relevant physics. The fusion community has been replying on resistive bolometers for plasma radiation measurement. However, their performance is greatly compromised by the strong electromagnetic interference present in MCF devices. Previously, we have demonstrated a fiber-optic bolometer that has the promise to overcome the challenges related to the strong EMI in the MCF environment. In this project, we study the performance of the fiber-optic bolometer in a simulated MCF environment and improved the sensitivity through a novel sensor design. Part of the work reported here was performed between 09/01-12/31/2017 when the PI was with University of Nebraska-Lincoln under the same project but with a different award number (DE-SC0018273).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First demonstration of a fiber optic bolometer on a tokamak plasma (invited)

A fiber optic bolometer (FOB) was demonstrated observing a fusion plasma for the first time at the DIII-D tokamak. A FOB uses a fiber optics-based interferometric technique that is designed to have a high sensitivity to temperature changes [75 mK/(W/m2) responsivity in high vacuum with 0.38 mK noise level] with a negligible susceptibility to electromagnetic interference (EMI) that can be problematic for resistive bolometers in a tokamak environment. A single-channel test apparatus was installed on DIII-D consisting of a measurement FOB and shielded reference FOB. The single-channel FOB showed a negligible increase in the noise level during typical plasma operations (0.39 mK) compared to the benchtop results (0.38 mK), confirming an insignificant EMI impact to the FOB. Comparisons to DIII-D resistive bolometers showed good agreement with the single-channel FOB, indicating that the FOB is comparable to a resistive bolometer when the impulse calibration is applied. The noise-equivalent power density of the calibrated FOB during a plasma operation was 0.55 W/m2 with an average sampling time of 20 ms. The major potential effect of ionizing radiation on the FOB would be the radiation-induced attenuation, which can be efficiently compensated for by adjusting the probing light power.

Lee, S. (ORCID:0000000170289004)↗

Design and commissioning of resistive foil bolometer diagnostics on the ST40 tokamak

Following successful campaigns on the compact high field spherical tokamak ST40, resistive gold foil bolometers have now been installed to measure the radiated power profile. Positioned on the midplane, two bolometer cameras offer perspectives of the horizontal and vertical planes, while the third camera, situated above the midplane, provides a vertical view of the top divertor plates, including the X-point and the strike points. Further, these cameras use a commercial off-the-shelf data acquisition platform with modules specifically designed for bolometers in a Wheatstone bridge configuration, providing both phase sensitive detection and in situ calibration. This paper presents an overview of the design and functionality of all three cameras and the commissioning of the horizontal plane camera. The commissioning of the horizontal camera shows data from a range of plasma pulses, presenting a positive correlation between the relative profiles measured from the bolometer camera and an absolute extreme ultraviolet diode camera viewing along similar lines of sight.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The infrared imaging video bolometer at Wendelstein 7-X

The radiated power distribution is a crucial aspect of heat transport, heat load mitigation, and plasma exhaust performance. An imaging video bolometer camera has been installed to measure the plasma radiated power in the divertor region of the Wendelstein 7-X (W7-X) stellarator. This diagnostic offers a wide-angle (40° × 68°) sampling of the plasma volume in both the poloidal and toroidal directions. The field-of-view is covered with a large number (> 500) of bolometer channels, providing imaging capability. The diagnostic design is introduced here together with its data analysis procedure. A set of laboratory experiments is performed to assess the thermal properties of the gold absorber foil and their spatial uniformity. Following installation, a heat source originating from the inertially cooled front of the diagnostic is identified and filtered out. The discharge data indicate a satisfactory signal-to-noise ratio as well as spatiotemporal resolution. These represent the first toroidally resolved images of the line-integrated radiated power in the W7-X island divertor. The diagnostic was then upgraded with a thinner platinum absorber and adjusted mirrors. Early data from the most recent experimental campaign employing the upgraded design show a considerable improvement in the diagnostic performance with more bolometer channels (> 1400), extended coverage, and increased spatial resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Twelve-crystal prototype of Li 2 MoO 4 scintillating bolometers for CUPID and CROSS experiments

An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, μBq/kg, level of the LMO crystals radioactive contamination by 228 Th and 226 Ra.

47 OTHER INSTRUMENTATION↗

Recent Developments of Commercially Fabricated Horn Antenna-Coupled Transition-Edge Sensor Bolometer Detectors for Next-Generation Cosmic Microwave Background Polarimetry Experiments

Here we report on the successful fabrication of orthomode transducer-coupled transition-edge sensor (TES) bolometer arrays for cosmic microwave background (CMB) polarimetry experiments with the superconductor electronics fabrication facility at SEEQC Inc. Commercial microfabrication foundry could provide increase in detector fabrication throughput for a next-generation CMB experiment, CMB-S4, that would deploy approximately one order of magnitude more detectors than current CMB experiments. We also developed TES bolometers with two TESs in series that have two different superconducting temperatures (Tc) using a superconducting proximity effect between niobium (Nb) and aluminum-manganese (AlMn) alloy. We will discuss the motivation, design considerations, fabrication processes, test results, and how industrial detector fabrication could be a path to fabricate hundreds of detector wafers for future CMB polarimetry experiments and other experiments that require TESs and superconducting RF circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Expected sensitivity to 128 Te neutrinoless double beta decay with the CUORE TeO 2 cryogenic bolometers

The CUORE experiment is a ton-scale array of TeO 2 cryogenic bolometers located at the underground Laboratori Nazionali del Gran Sasso of Istituto Nazionale di Fisica Nucleare (INFN), in Italy. The CUORE detector consists of 988 crystals operated as source and detector at a base temperature of ~ 10 mK. Such cryogenic temperature is reached and maintained by means of a custom built cryogen-free dilution cryostat, designed with the aim of minimizing the vibrational noise and the environmental radioactivity. The primary goal of CUORE is the search for neutrinoless double beta decay of 130 Te , but thanks to its large target mass and ultra-low background it is suitable for the study of other rare processes as well, such as the neutrinoless double beta decay of 128 Te. This tellurium isotope is an attractive candidate for the search of this process, due to its high natural isotopic abundance of 31.75%. The transition energy at (866.7 ± 0.7) keV lies in a highly populated region of the energy spectrum, dominated by the contribution of the two-neutrino double beta decay of 130 Te. As the first ton-scale infrastructure operating cryogenic TeO 2 bolometers in stable conditions, CUORE is able to achieve a factor > 10 higher sensitivity to the neutrinoless double beta decay of this isotope with respect to past direct experiments.

128-Te↗

Crosstalk Effects in Microwave SQUID Multiplexed TES Bolometer Readout

Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability is limited by their cryogenic readout electronics. Microwave SQUID multiplexing offers a highly capable scaling solution through the use of inherently broadband circuitry, enabling readout of hundreds to thousands of channels per microwave line. As with any multiplexing technique, the channelization mechanism gives rise to electrical crosstalk which must be understood and controlled so as to not degrade the instrument sensitivity. Here, in this study, we explore implications relevant for TES bolometer array applications, focusing in particular on upcoming mm-wave observatories such as the Simons Observatory and AliCPT. We model the relative contributions of the various underlying crosstalk mechanisms, evaluate the difference between fixed-tone and tone-tracking readout systems, and discuss ways in which crosstalk nonlinearity will complicate on-sky measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and implementation of a prototype infrared video bolometer (IRVB) in MAST Upgrade

A prototype infrared video bolometer (IRVB) was successfully deployed in the Mega Ampere Spherical Tokamak Upgrade (MAST Upgrade or MAST-U), the first deployment of such a diagnostic in a spherical tokamak. The IRVB was designed to study the radiation around the lower x-point, another first in tokamaks, and has the potential to estimate emissivity profiles with spatial resolution beyond what is achievable with resistive bolometry. The system was fully characterized prior to installation on MAST-U, and the results are summarized here. After installation, it was verified that the actual measurement geometry in the tokamak qualitatively matches the design; this is a particularly difficult process for bolometers and was done using specific features of the plasma itself. The installed IRVB measurements are consistent both with observations from other diagnostics, including magnetic reconstruction, visible light cameras, and resistive bolometry, as well as with the IRVB-designed view. Early results show that with conventional divertor geometry and only intrinsic impurities (for example, C and He), the progression of radiative detachment follows a similar path to that observed for large aspect ratio tokamaks: The peak of the radiation moves along the separatrix from the targets to the x-point and high-field side midplane with a toroidally symmetric structure that can eventually lead to strong effects on the core plasma inside the separatrix.

47 OTHER INSTRUMENTATION↗

Fiber-optic bolometer with low detection limit fabricated using thermal release tape and precise laser heating

Fiber-optic bolometers (FOBs) based on a fiber-tipped silicon Fabry–Perot (FP) interferometric temperature sensor and a gold disk absorber have been shown to be an attractive alternative to conventional resistive bolometers for plasma radiation measurement in fusion devices. Either a high-finesse FP or a low-finesse FP can be used, each with trade-offs between noise performance and fabrication complexity. In this paper, we present an FOB design that overcomes these limitations by combining a low-finesse long silicon FP cavity with a large gold disk absorber to achieve enhanced sensitivity and noise performance without increasing the fabrication complexity and the time constant. We also demonstrated a fabrication method for the sensor head facilitated by thermal release tape and precise laser heating. Our FOB demonstrates a temperature resolution of 0.08 mK, a cooling time constant of 230 ms, and a noise equivalent power density of 0.015 W m −2 . This represents an eightfold improvement over previous high-finesse FOBs and 26-fold improvement over previous low-finesse FOBs with similar demodulation bandwidths and similar cooling time constants.

Fabry–Perot interferometer↗

Optical Characterization of OMT-Coupled TES Bolometers for LiteBIRD

Feedhorn- and orthomode transducer- (OMT) coupled transition edge sensor (TES) bolometers have been designed and micro-fabricated to meet the optical specifications of the LiteBIRD high frequency telescope (HFT) focal plane. Here, we discuss the design and optical characterization of two LiteBIRD HFT detector types: dual-polarization, dual-frequency-band pixels with 195/280 GHz and 235/337 GHz band centers. Results show well-matched passbands between orthogonal polarization channels and frequency centers within 3% of the design values. The optical efficiency of each frequency channel is conservatively reported to be within the range 0.64–0.72, determined from the response to a cryogenic, temperature-controlled thermal source. These values are in good agreement with expectations and either exceed or are within 10% of the values used in the LiteBIRD sensitivity forecast. Lastly, we report a measurement of loss in Nb/SiN x /Nb microstrip at 100 mK and over the frequency range 200–350 GHz, which is comparable to values previously reported in the literature.

47 OTHER INSTRUMENTATION↗

Demonstration of a 1820 channel multiplexer for transition-edge sensor bolometers

The scalability of most transition-edge sensor arrays is limited by the multiplexing technology, which combines their signals over a reduced number of wires and amplifiers. Here, in this Letter, we present and demonstrate a multiplexer design optimized for transition-edge sensor bolometers with 1820 sensors per readout unit, a factor of two more than the previous state-of-the-art. The design is optimized for cosmic microwave background imaging applications, and it builds on previous microwave superconducting quantum interference device multiplexers by doubling the available readout bandwidth to the full 4–8 GHz octave. Evaluating the key performance metrics of yield, sensitivity, and crosstalk through laboratory testing, we find an end-to-end operable detector yield of 78%, a typical nearest-neighbor crosstalk amplitude of ∼0.4%, and a median white noise level of 83 pA/$\sqrt{\textrm{Hz}}$ due to the multiplexer, corresponding to an estimated contribution of 4% to the total system noise for a ground-based cosmic microwave background telescope. Additionally, we identify a possible path toward reducing resonator loss for future designs with reduced noise. We expect these developments to alleviate the system complexity, cryogenic requirements, and cost of future large arrays of low temperature detectors.

cosmic microwave background↗

Collaborative Research Towards a tonne-scale bolometer-based neutrinoless double beta decay experiment (Final Report)

Cryogenic bolometers are an excellent technology for neutrinoless double beta decay searches owing to their very high energy resolution and potential for high radiopurity. The current most advanced large-scale experiment using these detectors is the Cryogenic Underground Observatory for Rare Events (CUORE). The largest source of background in CUORE is degraded alpha particles, emitted from shallow depths of the detector holders, which can deposit a thermal energy signature similar to neutrinoless double beta decay. To mitigate this background, the CUPID concept (CUORE Upgrade with Particle IDentification) proposes to use scintillating cryogenic detectors. Detecting both the scintillation light and the thermal signal allows discrimination between alpha particle events and beta/gamma events. We report on the design and execution of R&D tests to optimize the design of the single detector module, in particular the scintillation light collection efficiency at cryogenic temperatures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Understanding the Phase of Responsivity and Noise Sources in Frequency-Domain Multiplexed Readout of Transition Edge Sensor Bolometers

Abstract Cosmic microwave background (CMB) experiments have deployed focal planes with $$\mathcal {O}(10^{4})$$ O ( 10 4 ) transition edge sensor (TES) bolometers cooled to sub-Kelvin temperatures by multiplexing the readout of many TES channels onto a single pair of wires. Digital Frequency-domain Multiplexing (DfMux) is a multiplexing technique used in many CMB polarization experiments, such as the Simons Array, SPT-3 G, and EBEX. The DfMux system studied here uses LC filters with resonant frequencies ranging from 1.5 to 4.5 MHz connected to an array of TESs. Each detector has an amplitude-modulated carrier tone at the resonant frequency of its accompanying LC resonator. The signal is recovered via quadrature demodulation where the in-phase (I) component of the demodulated current is in phase with the complex admittance of the circuit and the quadrature (Q) component is orthogonal to I. Observed excess current noise in the Q component is consistent with fluctuations in the resonant frequency. This noise has been shown to be non-orthogonal to the phase of the detector’s responsivity. We present a detailed analysis of the phase of responsivity of the TES and noise sources in our DfMux readout system. Further, we investigate how modifications to the TES operating resistance and bias frequency can affect the phase of noise relative to the phase of the detector responsivity, using data from Simons Array to evaluate our predictions. We find that both the phase of responsivity and phase of noise are functions of the two tuning parameters, which can be purposefully selected to maximize signal-to-noise (SNR) ratio.

47 OTHER INSTRUMENTATION↗

Overview and first measurements of the MAST Upgrade bolometer diagnostic

Here, a suite of multi-channel resistive bolometers has been implemented to measure the total radiation from Mega Amp Spherical Tokamak Upgrade plasmas, with cameras covering the core plasma and lower divertor chamber. Data are digitized and processed using novel field-programmable gate array-based electronics, offering improved compactness and new operational capabilities. A synthetic diagnostic has been developed to explore the quality of 2D reconstructions available from the system and to quantify the uncertainty on quantities such as the total radiated power. Measurements in the first campaign have demonstrated correct functioning of the diagnostic while also highlighting issues with electrical noise and some failure mechanisms of the detectors, as well as significant neutral beam fast-particle losses.

47 OTHER INSTRUMENTATION↗

Fiber-optic bolometers with high-temperature tolerance and reduced time constants for fusion plasma diagnostics

Fiber-optic bolometers (FOBs) designed for plasma radiation measurement in magnetically confined fusion environments have been previously developed and tested at the DIII-D tokamak. These FOBs utilize a silicon Fabry–Perot interferometer at the fiber tip for temperature measurement and a gold disk as a radiation absorber. This paper presents recent advancements in the development of FOBs with reduced cooling time constants and enhanced temperature tolerance. We also demonstrate high-temperature operation and report findings from irradiation tests. By incorporating a copper sensor holder as a thermal sink and integrating two closely packed sensor heads into a compact design, the cooling time constants were reduced to ∼100 ms in vacuum, while minimizing uncertainties caused by temperature gradients. The FOBs were subjected to heating at 400 °C for five hours, with no observed degradation in noise performance post-heating. High-temperature operation tests were conducted at ∼220 °C using a 404 nm square-wave modulated laser to simulate the plasma radiation. In addition, four FOBs constructed from copper-coated pure-silica fibers were fabricated and underwent irradiation testing, enduring a total γ-radiation dose of 15.2 MGy and a neutron fluence of 1.6 × 10 18 n/cm 2 . As a result, the FOBs maintained their physical integrity and the optical signal shows high visibility throughout the test.

42 ENGINEERING↗