Engineering PapersSearch

SEARCH · Engineering Papers

Results for “BLOOD PLASMA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The behavior of fatty acids in the blood plasma of monkeys following exposure to short term stresses

Monkeys exposed to short term stresses (immobilization, jealousy) were found to develop hyperlipacidemia with a rise in concentration of unsaturated fatty acids in blood plasma, especially of oleic acid, and a relative decrease of saturated free fatty acids, chiefly of palmitinic acid. This finding was more pronounced under immobilization stress than in the jealousy situation. Meanwhile, the composition of triglycerides did not change essentially under the conditions used.

Michailov, M. L.

Microbiomes of frozen blood plasma samples reveal potential pathogens in wild birds and rodents

The lack of genomic data on pathogens from wildlife severely limits our ability to track transmission patterns and trace the origins of an outbreak. There are currently millions of wildlife samples in biobanks around the world, including blood samples. Blood has traditionally been viewed as a sterile environment in healthy individuals, but recent evidence suggests that this is not the case, especially for wild animals. Our goal was to determine whether frozen plasma samples can be surveyed using 16S sequencing to provide information about potential hosts for pathogens for a more complete understanding of disease systems. We sequenced blood plasma from wild North American deer mice ( Peromyscus maniculatus ) and American kestrels ( Falco sparverius ) that were cryogenically stored for 7 and 13 years, respectively, and compared two DNA extraction kits. The kestrel samples contained a very high number of reads that could not be identified to phylum compared to the mouse samples. The two kits differed in the phyla and genera that were detected, and the Zymo kit, which is optimized for plasma and serum, produced more high-quality reads for both kestrel and mouse samples. We identified several pathogenic genera, including Mycoplasma, Escherichia-Shigella , and Bartonella . Sequencing blood samples for pathogens could potentially have broad applications for identifying important reservoir hosts for pathogen transmission and provide a reduced set of species on which to follow up.

59 BASIC BIOLOGICAL SCIENCES

Measurement of Human Blood and Plasma Volumes

Report reviews techniques for measuring blood-plasma volume in humans. Common technique of using radioactive iodine isotope to label plasma albumin involves unwarranted risks from low-level radiation. Report emphasizes techniques using Evans-blue-dye (T-1824) labeling of albumin, hematocrit or hemoglobin/hematocrit measurements, or blood densitometry. In Evans-blue-dye technique, plasma volume determined from decrease in dye concentration occurring after small amount of dye solution injected into circulatory system. Subjection of Evans blue dye to test for carcinogenicity gave negative results.

Greenleaf, J. E.

Method of high-precision microsampled blood and plasma mass densitometry

The reliability of the mechanical oscillator technique for blood and plasma density measurements on samples of volumes less than 0.1 ml is examined, and a precision of 0.001 g/l is found if plasma-isodensic heparin solution and siliconized densitometers are employed. Sources of measurement errors in the density determinations include storage of plasma samples, inhomogeneity of blood samples, and density reading before adequate temperature equilibration. In tests of plasma sample storage, the best reproducibility was obtained with samples kept at 4 C. Linear correlations were found between plasma density and plasma protein concentration, blood density and blood hemoglobin concentration, and erythrocyte density and MCHC.

Hinghofer-Szalkay, H.

Determining blood and plasma volumes using bioelectrical response spectroscopy

We hypothesized that an electric field (inductance) produced by charged blood components passing through the many branches of arteries and veins could assess total blood volume (TBV) or plasma volume (PV). Individual (N = 29) electrical circuits (inductors, two resistors, and a capacitor) were determined from bioelectrical response spectroscopy (BERS) using a Hewlett Packard 4284A Precision LCR Meter. Inductance, capacitance, and resistance from the circuits of 19 subjects modeled TBV (sum of PV and computed red cell volume) and PV (based on 125I-albumin). Each model (N = 10, cross validation group) had good validity based on 1) mean differences (-2.3 to 1.5%) between the methods that were not significant and less than the propagated errors (+/- 5.2% for TBV and PV), 2) high correlations (r > 0.92) with low SEE (< 7.7%) between dilution and BERS assessments, and 3) Bland-Altman pairwise comparisons that indicated "clinical equivalency" between the methods. Given the limitation of this study (10 validity subjects), we concluded that BERS models accurately assessed TBV and PV. Further evaluations of the models' validities are needed before they are used in clinical or research settings.

NASA Discipline Number 00-00

The effect of chronic erythrocytic polycythemia and high altitude upon plasma and blood volumes.

Comparison of two kinds of physiological chronic erythrocytic polycythemias in order to differentiate the specific effect of erythrocytic polycythemia from the general effects of high altitude upon the plasma volume. The two kinds were produced hormonally in female chickens, at sea level, or by protracted high-altitude exposures. It appears that the vascular system of the body may account for an increase in red blood cell mass either by reduction in plasma volume, or by no change in plasma volume, resulting in differential changes in total blood volumes.

Burton, R. R.

The effect of immobilization and 3 (beta-aminoethyl)-1, 2, 4 triazol on the calcium content in gastric tissues of guinea pigs during the formation of experimental ulcers

A sharp fall in the concentration of calcium in gastric tissues upon immobilization and after administration of the histamine analog was recorded. Similar shifts were seen to occur in the blood plasma as well. This implies that under the effect of different action, tissue dystrophy develops by following a common mechanism involving not only the adenyl cyclase system, but that of calcium ion metabolism as well. The calcium ion content in the blood plasma and gastric tissues were measured by atomic absorption spectrophotometry.

Grechishkin, L. L.

Comparison of the Physiology of the Spaceflight and Hindlimb Suspended Rat

The suspended rat has been used extensively as a simulation of the spaceflight animal. In suspension, hindlimbs are unloaded from the acceleration of gravity, much as they are in spaceflight. Comparisons of data from spaceflight (microgravity) and suspended (1G) rats have suggested that suspension my be an appropriate model, but no direct comparisons had been made between the spaceflight and suspended rat. Cosmos 2044 afforded the first opportunity to directly compare the effects of hindlimb suspension (HS) and spaceflight (SF) on a broad range of physiological and histological parameters. This paper reports on the comparison of skelton, skeletal muscle, heart, neural, pulmonary, kidney, liver, intestine, blood plasma, immune function, red blood cells, and endocrine and reproductive functions and systems.

Grindeland, R. E.

Changes in peak oxygen uptake and plasma volume in fit and unfit subjects following exposure to a simulation of microgravity

To test the hypothesis that the magnitude of reduction in plasma volume and work capacity following exposure to simulated microgravity is dependent on the initial level of aerobic fitness, peak oxygen uptake (VO2peak) was measured in a group of physically fit subjects and compared with VO2peak in a group of relatively unfit subjects before and after 10 days of continuous 6 degrees head-down tilt (HDT). Ten fit subjects (40 +/- 2 year) with mean +/- SE VO2peak = 48.9 +/- 1.7 mL kg-1 min-1 were matched for age, height, and lean body weight with 10 unfit subjects (VO2peak = 37.7 +/- 1.6 mL kg-1 min-1). Before and after HDT, plasma, blood, and red cell volumes and body composition were measured and all subjects underwent a graded supine cycle ergometer test to determine VO2peak period needed. Reduced VO2peak in fit subjects (-16.2%) was greater than that of unfit subjects (-6.1%). Similarly, reductions in plasma (-18.3%) and blood volumes (-16.0%) in fit subjects were larger than those of unfit subjects (blood volume = -5.6%; plasma volume = -6.6%). Reduced plasma volume was associated with greater negative body fluid balance during the initial 24 h of HDT in the fit group (912 +/- 154 mL) compared with unfit subjects (453 +/- 200 mL). The percentage change for VO2peak correlated with percentage change in plasma volume (r = +0.79). Following exposure to simulated microgravity, fit subjects demonstrated larger reductions in VO2peak than unfit subjects which was associated with larger reductions in plasma and blood volume. These data suggest that the magnitude of physical deconditioning induced by exposure to microgravity without intervention of countermeasures was influenced by the initial fitness of the subjects.

Non-NASA Center

Effect of training on blood volume and plasma hormone concentrations in the elderly

The purpose of this investigation was to determine the effects of 6 months of endurance training on resting plasma (PV) and blood volume (BV), and resting hormone and electrolyte concentrations in the elderly. Thirty-eight elderly men and women (ages 60-82 yr) were assigned to endurance exercise training (N = 29) or to control (N = 9) groups. Resting plasma levels of adrenocorticotropic hormone, vasopressin, aldosterone, norepinephrine, epinephrine, sodium, potassium, and protein were measured at the start (T1) and end (T2) of 26 wk of training. PV measurement was performed using the Evan's blue dye technique. Endurance training consisted of uphill treadmill walking or stairclimbing exercise 3 times.wk-1, 30-45 min.d-1, at 75-84% of maximal heart rate reserve. The exercise group increased VO2max by 11.2% (P < or = 0.05) and increased resting PV and BV by 11.2% and 12.7% (P < or = 0.05), respectively. Hormone and electrolyte levels in the exercise group remained unchanged; all variables were unchanged in the control group. These results are similar to findings in younger individuals. Because plasma hormone concentrations were maintained despite a chronically elevated BV, endurance training in healthy, elderly subjects may be associated with a resetting of volume receptors.

Clinical Trial

Studies on the bioassayable growth hormone-like activity of plasma

Evidence supporting the existence of bioassayable growth hormone-like activity in blood plasma distinct from the growth hormone measurable by radioimmunoassay and from somatomedin is presented. Tibial assays of the growth-hormone-like activity of injected, concentrated normal human and rat plasma in hypophysectomized rats reveal 200- and 50-fold activity excesses, respectively, with respect to the amount of growth hormone detected by radioimmunoassay. The origin of this bioassayable plasma hormone has been localized to the region of the pituitary, the origin of growth hormone, a distribution not followed by somatomedin C. Purification of the bioassayable agent indicates that is has a molecular weight of between 60,000 and 80,000, in contrast to that of growth hormone (20,000), and that the bioassayable activity is distinct from that of somatomedin C. Growth hormone-like activity detected in Cohn fraction IV as well as plasma activity, are found to be collectable on Dowex 50 resin, in contrast to somatomedin C and nonsuppressible insulin-like activity. The formation of bioassayable growth hormone-activity agents from radioimmunoassayable growth hormone and directly in the pituitary is suggested.

Ellis, S.