Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BETATRONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Specific features of betatron oscillations and betatron emission in a hollow-channel plasma

Transverse betatron oscillations and the corresponding betatron emission are investigated for electrons in a strongly non-linear wake wave excited by a high-power laser pulse in a hollow-channel plasma. The expressions for the oscillation period and critical frequency in the synchrotron regime of betatron emission are derived. A two-stage scheme is considered, in which an electron bunch formed in a plasma possessing a certain set of parameters generates betatron emission in a plasma possessing another set of parameters. The emission spectrum at the second stage is calculated in the absence of bunch acceleration. (paper)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electron energy gain due to a laser frequency modulation experienced by electron during betatron motion

Direct laser acceleration of electrons is an important energy deposition mechanism for laser-irradiated plasmas that is particularly effective at relativistic laser intensities in the presence of quasi-static laser-driven plasma electric and magnetic fields. These radial electric and azimuthal magnetic fields provide transverse electron confinement by inducing betatron oscillations of forward-moving electrons undergoing laser acceleration. Electrons are said to experience a betatron resonance when the frequency of betatron oscillations matches the average frequency of the laser field oscillations at the electron position. In this paper, we show that the modulation of the laser frequency as seen by an electron performing betatron oscillations can be another important mechanism for net energy gain that is qualitatively different from the betatron resonance. Specifically, we show that the frequency modulation experienced by the electron can lead to net energy gain in the regime where the laser field performs three oscillations per betatron oscillation. There is no net energy gain in this regime without the modulation because the energy gain is fully compensated by the energy loss. The modulation slows down the laser oscillation near transverse stopping points, increasing the time interval during which the electron gains energy and making it possible to achieve net energy gain.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced betatron radiation in strongly magnetized plasma

Betatron radiation in strongly magnetized plasma is investigated by two dimensional (2D) particle-in-cell (PIC) simulations. The results show that the betatron radiation in magnetized plasmas is strongly enhanced and is more collimated compared to that in unmagnetized plasma. Single particle model analysis shows that the frequency and the amplitude of the electrons's betatron oscillation are strongly influenced by the axial external magnetic field and the axial self-generated magnetic field. And the 2D PIC simulation shows that the axial magnetic field is actually induced by the external magnetic field and tends to increase the betatron frequency. By disturbing the perturbation of the plasma density in the laser-produced channel, the hosing instability is also suppressed, which results in a better angular distribution and a better symmetry of the betatron radiation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A broadband gamma-ray spectrometry using novel unfolding algorithms for characterization of laser wakefield-generated betatron radiation

We present a high-flux, broadband gamma-ray spectrometry capable of characterizing the betatron radiation spectrum over the photon energy range from 10 keV to 20 MeV with respect to the peak photon energy, spectral bandwidth, and unique discrimination from background radiations, using a differential filtering spectrometer and the unfolding procedure based on the Monte Carlo code GEANT4. These properties are experimentally verified by measuring betatron radiation from a cm-scale laser wakefield accelerator (LWFA) driven by a 1-PW laser, using a differential filtering spectrometer consisting of a 15-filter and image plate stack. The gamma-ray spectra were derived by unfolding the photostimulated luminescence (PSL) values recorded on the image plates, using the spectrometer response matrix modeled with the Monte Carlo code GEANT4. The accuracy of unfolded betatron radiation spectra was assessed by unfolding the test PSL data simulated with GEANT4, showing an ambiguity of less than 20% and clear discrimination from the background radiation with less than 10%. The spectral analysis of betatron radiation from laser wakefield-accelerated electron beams with energies up to 3 GeV revealed radiation spectra characterized by synchrotron radiation with the critical photon energy up to 7 MeV. The gamma-ray spectrometer and unfolding method presented here facilitate an in-depth understanding of betatron radiation from LWFA process and a novel radiation source of high-quality photon beams in the MeV regime.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast Imaging of Laser Driven Shock Waves using Betatron X-rays from a Laser Wakefield Accelerator

Abstract Betatron radiation from laser wakefield accelerators is an ultrashort pulsed source of hard, synchrotron-like x-ray radiation. It emanates from a centimetre scale plasma accelerator producing GeV level electron beams. In recent years betatron radiation has been developed as a unique source capable of producing high resolution x-ray images in compact geometries. However, until now, the short pulse nature of this radiation has not been exploited. This report details the first experiment to utilize betatron radiation to image a rapidly evolving phenomenon by using it to radiograph a laser driven shock wave in a silicon target. The spatial resolution of the image is comparable to what has been achieved in similar experiments at conventional synchrotron light sources. The intrinsic temporal resolution of betatron radiation is below 100 fs, indicating that significantly faster processes could be probed in future without compromising spatial resolution. Quantitative measurements of the shock velocity and material density were made from the radiographs recorded during shock compression and were consistent with the established shock response of silicon, as determined with traditional velocimetry approaches. This suggests that future compact betatron imaging beamlines could be useful in the imaging and diagnosis of high-energy-density physics experiments.

43 PARTICLE ACCELERATORS↗

Transverse oscillating bubble enhanced laser-driven betatron X-ray radiation generation

Abstract Ultrafast high-brightness X-ray pulses have proven invaluable for a broad range of research. Such pulses are typically generated via synchrotron emission from relativistic electron bunches using large-scale facilities. Recently, significantly more compact X-ray sources based on laser-wakefield accelerated (LWFA) electron beams have been demonstrated. In particular, laser-driven sources, where the radiation is generated by transverse oscillations of electrons within the plasma accelerator structure (so-called betatron oscillations) can generate highly-brilliant ultrashort X-ray pulses using a comparably simple setup. Here, we experimentally demonstrate a method to markedly enhance the parameters of LWFA-driven betatron X-ray emission in a proof-of-principle experiment. We show a significant increase in the number of generated photons by specifically manipulating the amplitude of the betatron oscillations by using our novel Transverse Oscillating Bubble Enhanced Betatron Radiation scheme. We realize this through an orchestrated evolution of the temporal laser pulse shape and the accelerating plasma structure. This leads to controlled off-axis injection of electrons that perform large-amplitude collective transverse betatron oscillations, resulting in increased radiation emission. Our concept holds the promise for a method to optimize the X-ray parameters for specific applications, such as time-resolved investigations with spatial and temporal atomic resolution or advanced high-resolution imaging modalities, and the generation of X-ray beams with even higher peak and average brightness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single-Shot Diagnosis of Electron Energy Evolution via Streaked Betatron X Rays in a Curved Laser Wakefield Accelerator

We report on an experimental observation of the streaking of betatron x rays in a curved laser wakefield accelerator. The streaking of the betatron x rays was realized by launching a laser pulse into a plasma with a transverse density gradient. By controlling the plasma density and the density gradient, we realized the steering of the laser driver, electron beam, and betatron x rays simultaneously. Furthermore, we observed an energy-angle correlation of the streaked betatron x rays and utilized it in diagnosing the electron acceleration process in a single-shot mode. Our work could also find applications in advanced control of laser beam and particle propagation. More importantly, the angular streaked betatron x ray has an intrinsic spatiotemporal correlation, which makes it a promising tool for single-shot pump-probe applications.

43 PARTICLE ACCELERATORS↗

Measurement of angularly dependent spectra of betatron gamma-rays from a laser plasma accelerator with quadrant-sectored range filters

Measurement of angularly dependent spectra of betatron gamma-rays radiated by GeV electron beams from laser wakefield accelerators (LWFAs) are presented. The angle-resolved spectrum of betatron radiation was deconvolved from the position dependent data measured for a single laser shot with a broadband gamma-ray spectrometer comprising four-quadrant sectored range filters and an unfolding algorithm, based on the Monte Carlo code GEANT4. The unfolded gamma-ray spectra in the photon energy range of 0.1–10 MeV revealed an approximately isotropic angular dependence of the peak photon energy and photon energy-integrated fluence. As expected by the analysis of betatron radiation from LWFAs, the results indicate that unpolarized gamma-rays are emitted by electrons undergoing betatron motion in isotropically distributed orbit planes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep learning based x-ray spectrometer for high repetition rate characterization of betatron radiation

Betatron radiation produced from a laser-wakefield accelerator is a broadband, hard x-ray (>1 keV) source that has been used in a variety of applications in medicine, engineering, and fundamental science. Further development and optimization of stable, high repetition rate (HRR) (>1 Hz) betatron sources will provide a means to extend their application base to include single-shot dynamical measurements of ultrafast processes or dense materials. Recent advances in laser technology used in such experiments have enabled increases in shot-rate and system stability, providing improved statistical analysis and detailed parameter scans. However, unique challenges exist at high repetition rate, where data throughput and source optimization are now limited by diagnostic acquisition rates and analysis. Here, we present the development of a machine-learning algorithm for the real-time analysis of betatron radiation. We report on the fielding of this deep learning algorithm for online source characterization at the Institut National de la Recherche Scientifique's Advanced Laser Light Source. By fine-tuning an algorithm originally trained on a fully synthetic dataset using a subset of experimental data, the algorithm can predict the betatron critical energy with a percent error of 7.2 % with a reconstruction time of 1.5 ms, providing a valuable tool for real-time, multi-objective optimization at HRR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Controlled Betatron X-Ray Radiation from Tunable Optically Injected Electrons

The features of Betatron x-ray emission produced in a laser-plasma accelerator are closely linked to the properties of the relativistic electrons which are at the origin of the radiation. While in interaction regimes explored previously the source was by nature unstable, following the fluctuations of the electron beam, we demonstrate in this Letter the possibility to generate x-ray Betatron radiation with controlled and reproducible features, allowing fine studies of its properties. To do so, Betatron radiation is produced using monoenergetic electrons with tunable energies from a laser-plasma accelerator with colliding pulse injection [J. Faure et al., Nature (London) 444, 737 (2006)]. The presented study provides evidence of the correlations between electrons and x-rays, and the obtained results open significant perspectives toward the production of a stable and controlled femtosecond Betatron x-ray source in the keV range.

43 PARTICLE ACCELERATORS↗

High-resolution phase-contrast imaging of biological specimens using a stable betatron X-ray source in the multiple-exposure mode

Abstract Phase-contrast imaging using X-ray sources with high spatial coherence is an emerging tool in biology and material science. Much of this research is being done using large synchrotron facilities or relatively low-flux microfocus X-ray tubes. An alternative high-flux, ultra-short and high-spatial-coherence table-top X-ray source based on betatron motions of electrons in laser wakefield accelerators has the promise to produce high quality images. In previous phase-contrast imaging studies with betatron sources, single-exposure images with a spatial resolution of 6–70 μ m were reported by using large-scale laser systems (60–200 TW). Furthermore, images obtained with multiple exposures tended to have a reduced contrast and resolution due to the shot-to-shot fluctuations. In this article, we demonstrate that a highly stable multiple-exposure betatron source, with an effective average source size of 5 μ m, photon number and pointing jitters of <5% and spectral fluctuation of <10%, can be obtained by utilizing ionization injection in pure nitrogen plasma using a 30–40 TW laser. Using this source, high quality phase-contrast images of biological specimens with a 5- μ m resolution are obtained for the first time. This work shows a way for the application of high resolution phase-contrast imaging with stable betatron sources using modest power, high repetition-rate lasers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Betatron x-ray radiation from laser-plasma accelerators driven by femtosecond and picosecond laser systems

A comparative experimental study of betatron x-ray radiation from laser wakefield acceleration in the blowout and self-modulated regimes is presented. Our experiments use picosecond duration laser pulses up to 150 J (self-modulated regime) and 60 fs duration laser pulses up to 10 J (blowout regime), for plasmas with electronic densities on the order of 10 19 cm –3 . In the self-modulated regime, where betatron radiation has been very little studied compared to the blowout regime, electrons accelerated in the wake of the laser pulse are subject to both the longitudinal plasma and transverse laser electrical fields. As a result, their motion within the wake is relatively complex; consequently, the experimental and theoretical properties of the x-ray source based on self-modulation differ from the blowout regime of laser wakefield acceleration. In our experimental configuration, electrons accelerated up to about 250 MeV and betatron x-ray spectra with critical energies of about 10–20 keV and photon fluxes between 10 8 and 10 10 photons/eV Sr are reported. In conclusion, our experiments open the prospect of using betatron x-ray radiation for applications, and the source is competitive with current x-ray backlighting methods on multi-kilojoule laser systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Angular streaking of betatron X-rays in a transverse density gradient laser-wakefield accelerator

In a plasma with a transverse density gradient, laser wavefront tilt develops gradually due to phase velocity differences in different plasma densities. The wavefront tilt leads to a parabolic trajectory of the plasma wakefield and hence the accelerated electron beam, which leads to an angular streaking of the emitted betatron radiation. In this way, the temporal evolution of the betatron X-ray spectra will be converted into angular “streak,” i.e., having a critical energy-angle correlation. An analytical model for the curved trajectory of a laser pulse in a transverse density gradient is presented. This gives the deflection angle of the electron beam and the betatron X-rays as a function of the plasma and laser parameters, and it was verified by particle-in-cell simulations. This angular streaking could be used as a single-shot diagnostic technique to reveal the temporal evolution of betatron X-ray spectra and hence the electron acceleration itself.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proof-of-Principle Studies on Betatron-Oscillation Phase Tracking of a Single Electron (BOPTSE) in IOTA Run 3

We present a description and preliminary results of the proof-of-principle studies on betatron-oscillation phase tracking of a single electron in the Fermilab IOTA storage ring during Run 3 (2021). We describe the general principles of the experiment, the optical diagnostics setup, the configuration of the ring, a chronology of the studies, the structure of the measured data, and results of the preliminary analysis of the collected data. It was observed that the coherence time of betatron oscillations exceeds 60,000 turns. The betatron tune of the single electron was accurately measured and compared with that of electron bunches. In addition, chromaticity was extracted from the combined analysis of synchrotron oscillations and betatron phase tracking.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Betatron radiation from a beam driven plasma source

Photons produced by the betatron oscillation of electrons in a beam-driven plasma wake provide a uniquely intense and high-energy source of hard X-rays and gamma rays. This betatron radiation is interesting not only for its high intensity and spectral characteristics, but also because it can be used as a diagnostic for beam matching into the plasma, which is critical for maximizing the energy extraction efficiency of a plasma accelerator stage. At SLAC, gamma ray detection devices have been installed at the dump area of the FACET beamline where the betatron radiation from the plasma source used in the E200 plasma wakefield acceleration experiment may be observed. The ultra-dense, high-energy beam at FACET (2 Multiplication-Sign 10{sup 10} electrons, 20 Multiplication-Sign 20{mu}m{sup 2} spot, 20 - 100{mu}m length, 20GeV energy) when sent into a plasma source with a nominal density of {approx} 1 Multiplication-Sign 10{sup 17} cm{sup -3} will generate synchrotron-like spectra with critical energies well into the tens of MeV. The intensity of the radiation can be increased by introducing a radial offset to the centroid of the witness bunch, which may be achieved at FACET through the use of a transverse deflecting RF cavity. The E200 gamma ray detector has two main components: a 30 Multiplication-Sign 35cm{sup 2} phosphorescent screen for observing the transverse extent of the radiation, and a sampling electromagnetic calorimeter outfitted with photodiodes for measuring the on-axis spectrum. To estimate the spectrum, the observed intensity patterns across the calorimeter are fit with a Gaussian-integrated synchrotron spectrum and compared to simulations. Results and observations from the first FACET user run (April-June 2012) are presented.

43 PARTICLE ACCELERATORS↗

Betatron Radiation from a Beam Driven Plasma Source

Photons produced by the betatron oscillation of electrons in a beam-driven plasma wake provide a uniquely intense and high-energy source of hard X-rays and gamma rays. This betatron radiation is interesting not only for its high intensity and spectral characteristics, but also because it can be used as a diagnostic for beam matching into the plasma, which is critical for maximizing the energy extraction efficiency of a plasma accelerator stage. At SLAC, gamma ray detection devices have been installed at the dump area of the FACET beamline where the betatron radiation from the plasma source used in the E200 plasma wakefield acceleration experiment may be observed. The ultra-dense, high-energy beam at FACET (2 x 10{sup 10} electrons, 20 x 20 {micro}m{sup 2} spot, 20-100 {micro}m length, 20 GeV energy) when sent into a plasma source with a nominal density of {approx} 1 x 10{sup 17} cm{sup -3} will generate synchrotron-like spectra with critical energies well into the tens of MeV. The intensity of the radiation can be increased by introducing a radial offset to the centroid of the witness bunch, which may be achieved at FACET through the use of a transverse deflecting RF cavity. The E200 gamma ray detector has two main components: a 30 x 35 cm{sup 2} phosphorescent screen for observing the transverse extent of the radiation, and a sampling electromagnetic calorimeter outfitted with photodiodes for measuring the on-axis spectrum. To estimate the spectrum, the observed intensity patterns across the calorimeter are fit with a Gaussian-integrated synchrotron spectrum and compared to simulations. Results and observations from the first FACET user run (April-June 2012) are presented.

43 PARTICLE ACCELERATORS↗