At least 19 records

Analysis of coherent quantum cryptography protocol vulnerability to an active beam-splitting attack

We consider a new type of attack on a coherent quantum key distribution protocol [coherent one-way (COW) protocol]. The main idea of the attack consists in measuring individually the intercepted states and sending the rest of them unchanged. We have calculated the optimum values of the attack parameters for an arbitrary length of a communication channel and compared this novel attack with a standard beam-splitting attack. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of Stark-split beam and carbon charge exchange emissions for simultaneous B-field and temperature/rotation analysis at DIII-D

A set of two newly designed, single-channel Czerny–Turner spectrometers has been deployed at the DIII-D tokamak for measurements of the motional Stark effect (MSE) split beam emission and the C6+ (CVI) carbon charge exchange recombination (CER) emission at high spectral (δλ = 0.13 nm) and temporal (1–5 kHz) resolution. High throughput optics (f/# = 2.8) allow for good signal-to-noise at high time resolution using fast EMCCD detectors. The MSE emission allows for spectral fitting of the magnitude and direction of the local B-field, while the carbon emission yields local ion temperature and toroidal rotation information. To reduce so-called Doppler broadening of the MSE emission, a new channel-specific variable lens-masking approach has been developed. Experimental data collected from the 2023 DIII-D experimental campaign demonstrate the signal quality and instrument fidelity for both diagnostic measurements. Moreover, initial CER data analysis shows a clear evolution of the toroidal rotation during edge localized modes. Initial progress on the advanced MSE model, including a new validated ray-trace model of the DIII-D collection optics, is shown via sensitivity analysis.

Instruments & Instrumentation↗

High quality factor non-uniform metasurfaces

High quality factor electromagnetic metasurfaces are provided. The metasurface is configured to have in plane guided-mode resonances (e.g., corresponding to waveguide modes or the like). Coupling features are included in the metasurface that are configured to couple free-space radiation to the guided mode resonances. The resulting structures have a high-Q response to free-space radiation and can be used for various applications, such as beam splitting, beam steering, and beam focusing or defocusing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and simulation study of ultra-fast beam bunches split for three orthogonal planes high-energy electron dynamic radiography

Here a compact three orthogonal planes high-energy electron radiography system was proposed. One of the critical technologies, the ultra-fast beam bunches split from the bunch train are studied. The separated bunches could be transported to the three orthogonal planes of the target for dynamic radiography diagnostics. The key elements of the ultra-fast bunches split system are transverse deflecting cavity (TDC) and the twin septum magnet (TSM). The principle of TDC and TSM are briefly introduced. An example of the beam bunches split system for test experiment (40 MeV electron beam) with TDC and TSM is designed and studied by particle-tracking simulation and it confirms this method is valid and feasible. Especially with TSM, a compact three orthogonal planes radiography system can be realized. The evolution of the beam parameters along the beam line from simulation are investigated. The detailed design of the beam split system and beam dynamics simulation study are presented in this paper.

Zhao, Q. T.↗

Public Data Set: Spatial Heterodyne Spectroscopy for High Speed Measurements of Stark Split Neutral Beam Emission in a High Temperature Plasma

This public data set contains openly-documented, machine readable digital research data corresponding to figures published in M.G. Burke et al., 'Spatial Heterodyne Spectroscopy for High Speed Measurements of Stark Split Neutral Beam Emission in a High Temperature Plasma,' Review of Scientific Instruments 89, 10D114 (2018).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatial heterodyne spectroscopy for high speed measurements of Stark split neutral beam emission in a high temperature plasma

Measurement of electrostatic potential, or local electric field, turbulence is a critical missing component in validating nonlinear turbulence and transport simulations of fusion plasmas. A novel diagnostic is being developed for measuring local electric field fluctuations, $\sim\atop{E}$(r,t), via high-speed measurements of the light emitted from a hydrogenic neutral beam. It exploits the proportionality of the spectral line splitting from the Motional Stark Effect to the total electric field experienced by the neutral atom at the excitation site. The measurement is localized by the usual cross-beam geometry of beam-spectroscopy measurements. The corner stone of the diagnostic is a high spectral resolution, high etendue spatial heterodyne spectrometer (SHS). A SHS design with high etendue (~5 mm 2 sr) and resolution (~0.14 nm) meets the formidable spectrometer requirements. Field tests of the spectrometer at the DIII-D tokamak demonstrate that the beam emission spectrum produced by the SHS agrees with that of a traditional spectrometer and that the measured flux is adequate for turbulence studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Arrays of glass wedges for multi-dimensional optical diagnostics

There is a common need in the advancement of optical diagnostic techniques to increase the dimensionality of measurements. For example, point measurements could be improved to multi-point, line, planar, volumetric, or time-resolved volumetric measurements. In this work, a unique optical element is presented to enable multi-dimensional measurements, namely, an array of glass wedges. A light source is passed through the wedges, and different portions of the illumination are refracted by different amounts depending on the glass wedge angle. Subsequent optics can be used to focus the light to multiple points, lines, or planes. Basic characterization of a glass wedge array is presented. Additional wedge-array configurations are discussed, including the use of a periodic intensity mask for multi-planar measurements via structured illumination. The utility of this optical element is briefly demonstrated in (a) multi-planar flame particulate measurements, (b) multi-point femtosecond-laser electronic excitation tagging for flow velocimetry, and (c) multi-line nitric oxide molecular tagging velocimetry in a hypersonic shock-tunnel. One significant advantage of this optical component is its compatibility with high-energy laser sources, which may be a limiting factor with other beam-splitting or beam-forming elements such as some diffractive optics. Additionally, an array of glass wedges is simple and easily customizable compared to other methods for forming multiple closely spaced illumination patterns. In conclusion, suggestions for further development and applications are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nekton Interaction Monitoring System

The software provides a real-time processing system for sonar to detect and track animals, and to extract water column biomass statistics in order to facilitate continuous monitoring of an underwater environment. The Nekton Interaction Monitoring System (NIMS) extracts and archives tracking and backscatter statistics data from a real-time stream of data from a sonar device. NIMS also sends real-time tracking messages over the network that can be used by other systems to generate other metrics or to trigger instruments such as an optical video camera. A web-based user interface provides remote monitoring and control. NIMS currently supports three popular sonar devices: M3 multi-beam sonar (Kongsberg), EK60 split-beam echo-sounder (Simrad) and BlueView acoustic camera (Teledyne).

Source record↗

Nekton Interaction Monitoring System

The software provides a real-time processing system for sonar to detect and track animals, and to extract water column biomass statistics in order to facilitate continuous monitoring of an underwater environment. The Nekton Interaction Monitoring System (NIMS) extracts and archives tracking and backscatter statistics data from a real-time stream of data from a sonar device. NIMS also sends real-time tracking messages over the network that can be used by other systems to generate other metrics or to trigger instruments such as an optical video camera. A web-based user interface provides remote monitoring and control. NIMS currently supports three popular sonar devices: M3 multi-beam sonar (Kongsberg), EK60 split-beam echo-sounder (Simrad) and BlueView acoustic camera (Teledyne).

Source record↗

Interaction of doughnut-shaped laser pulses with glasses

Non-Gaussian laser beams can open new opportunities for microfabrication, including ultrashort laser direct writing. By using a model based on Maxwell’s equations, we investigate the dynamics of doughnut-shaped laser beams focused inside fused silica glass, in comparison with Gaussian pulses of the same energy. The laser propagation dynamics reveals intriguing features of beam splitting and sudden collapse toward the beam axis, overcoming the intensity clamping effect. The resulting structure of light absorption represents a very hot, hollow nanocylinder, which can lead to an implosion process that brings matter to extreme thermodynamic states. Furthermore, by monitoring the simulations of the laser beam scattering we see a considerable difference in both the blueshift and the angular distribution of scattered light for different laser energies, suggesting that investigations of the spectra of scattered radiation can be used as a diagnostic of laser-produced electron plasmas in transparent materials.

42 ENGINEERING↗

Coherent-state quantum cryptography using pseudorandom number generators

Quantum key distribution plays an important role in modern cryptography, since the security of the transmitted keys is guaranteed by fundamental laws of nature. A method using pseudorandom number generators well known from classical cryptography is considered. It is shown that their use in quantum cryptography makes it possible to increase the key generation rate under very weak assumptions about the capabilities of the eavesdropper. A practical scheme of a coherent-state quantum key distribution protocol using pseudorandom sequences is proposed. The cryptographic strength of the proposed protocol against a beam-splitting attack is considered. (quantum cryptography)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Are There Enough Decoy States to Ensure Key Secrecy in Quantum Cryptography?

The decoy state method has been proposed to detect a photon number splitting (PNS) attack. Today, the decoy state method is considered to be an almost universal method for proving the secrecy of quantum cryptography protocols and calculating the length of a secret key. In this paper, it is shown that there exist attacks, for example, a beam splitting (BS) attack, to which the decoy state method turns out to be insensitive. The decoy state method is oriented to the detection of changes in the photocount statistics of information states and decoy states under a PNS attack. Under a BS attack, the photocount statistics is not changed. As a result, the decoy state method significantly overestimates the length of the key. Thus, the decoy state method is not a universal method that allows the detection of various attacks. Apparently, due to a large number of publications on the decoy state method, a widespread opinion has been formed that this method is universal. This fact has led to attempts to adopt this method as an international standard in quantum cryptography, which is clearly premature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Full wave modeling of radio-frequency beams in tokamaks in the electron cyclotron frequency range

Simulation of full wave, without paraxial approximation, high-resolution solution of wave equations in frequency domain in the electron cyclotron resonance (ECR) frequency range for realistic Tokamak plasma parameters became possible by using recently formulated hybrid iterative algorithm [Svidzinski et al., Phys. Plasmas 25, 082509 (2018)] for numerically solving discretized wave equations. This approach combines time evolution and iterative relaxation techniques into iteration cycles. This algorithm is implemented in 2D code FullWave, solving wave equations in Tokamaks in cold and hot plasma models, and it has been tested in 3D full wave iterative RF beams simulation tool, which is presently being developed to model 3D ECRH RF beams in fusion devices using dynamic grid adaptation. The results of 2D full wave modeling, assuming specified toroidal mode number, of ECRH RF beams in DIII-D plasma, performed in the cold and hot plasma models for outboard and top launch scenarios using FullWave are presented. Nonlocal hot plasma response model, based on accurate numerical solution of linearized Vlasov equation, is used to model beam propagation and absorption in the 2nd electron cyclotron harmonic region. Demonstration of capability of the hybrid iterative algorithm to model ECRH RF beams in 3D is made by simulating a substantial part of realistic beam in DIII-D, launched from outboard side of the machine. All relevant physics of RF beam propagation, most of which is not captured in paraxial approximation, such as beam's divergence, interference between the X and O modes in the beam, X-O mode conversion, beam splitting into the X and O mode beams, transformation of beam's cross section, and absorption at the 2nd electron cyclotron harmonic, is captured in the simulations. A numerical technique to find an optimal beam polarization at the launcher to launch a nearly pure X or O mode beam in plasma is developed and tested.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An optically passive method that rate doubles 2-GHz timing fiducials

Solid-state optical comb-pulse generators provide a convenient and accurate method to include timing fiducials in a streak camera image for time base correction. Commercially available vertical-cavity surface-emitting lasers (VCSEL’s) emitting in the visible currently in use can be modulated up to 2 GHz. An optically passive method is presented to interleave a time-delayed path of the 2-GHz comb with itself, producing a 4-GHz comb. This technique can be applied to VCSEL’s with higher modulation rates. A fiber-delivered, randomly polarized 2 GHz VCSEL comb is polarization split into s polarization and p polarization paths. One path is time delayed relative to the other by twice the 2-GHz rate with 1-ps accuracy; the two paths then recombine at the fiber-coupled output. High throughput (≥90%) is achieved by carefully using polarization beam-splitting cubes, a total internal reflection beam-path–steering prism, and antireflection coatings. The glass path-length delay block and turning prism are optically contacted together. The beam polarizer cubes that split and recombine the paths are precision aligned and permanently cemented into place. We expect the palm-sized, inline fiber-coupled, comb-rate–doubling device to maintain its internal alignment indefinitely.

optical comb-pulse generators, timing fiducials, s↗

Summary of RF Technology Program Activities, October 2013 - September 2017

The goals of the National RF Research and Development Program (NRRDP) are to advance the basic understanding of high-power radio frequency (RF) in a plasma environment, and to maintain the high-power transmitters and cooling water systems required to support the ITER Ion Cylcotron Range of Frequencies (ICRF) transmission line high power component testing and operation of the Proto-Material Plasma Exposure eXperiment (MPEX) device. The work includes the study of the RF sheath, and development of RF-related diagnostics. These include active and passive spectroscopic diagnostics that can provide local and line integrated measurements of RF and Direct Current (DC) electric fields in the edge plasma of fusion devices, as well as measurements of other parameters. One of these, the Doppler Free Saturation Spectroscopy (DFSS) diagnostic, utilizes a laser beam split into two intersecting, counter-propagating pump and probe beams, whose intersection defines the measurement region. DFSS has demonstrated measurements of atomic spectra with 500 times greater resolution than passive Optical Emission Spectroscopy (OES). This allows Stark effect based electric field measurements to be made with two orders of magnitude high sensitivity than with OES. Measurements have been made using an ORNL electron-cyclotron resonant (ECR) plasma source producing densities up to 10 19 m -3 , in the vicinity of an RF-biased planar electrode.

47 OTHER INSTRUMENTATION↗