Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM PULSERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Tunable electron beam pulser for picoseconds stroboscopic microscopy in transmission electron microscopes

For two decades, time-resolved transmission electron microscopes (TEM) have relied on pulsed-laser photoemission to generate electron bunches to explore sub-microsecond to sub-picosecond dynamics. Despite the vast successes of photoemission time-resolved TEMs, laser-based systems are inherently complex, thus tend not to be turn-key. In this paper, we report on the successful retrofit of a commercial 200 keV TEM, without an external laser, capable of producing continuously tunable pulsed electron beams with repetition rates from 0.1 GHz up to 12 GHz and a tunable bunch length from tens of nanoseconds down to 10 ps. This innovation enables temporal access into previously inaccessible regimes: i.e., high repetition rate stroboscopic experiments. Combination of a pair of RF-driven traveling wave stripline elements, quadrupole magnets, and a variable beam aperture enables operation of the instrument in (1) continuous waveform (CW) mode as though the instrument was never modified (i.e. convention TEM operation mode, where the electrons from the emission cathode randomly arrive at the sample without resolvable time information), (2) stroboscopic (pump-probe) mode, and (3) pulsed beam mode for dose rate sensitive materials. In order to analyze the effect of a pulsed beam on image quality, we examined Au nanoparticles using bright field, high-resolution TEM imaging and selected area diffraction in both continuous and pulsed-beam mode. Furthermore, in comparison of conventional TEMs, the add-on beam pulser enables the observation of ultrafast dynamic behavior in materials that are reversible under synchronized excitation.

36 MATERIALS SCIENCE↗

Broad band tunable energy electron beam pulser

An electromagnetic mechanical pulser implements a transverse wave metallic comb stripline TWMCS kicker having inwardly opposing teeth that retards a phase velocity of an RF traveling wave to match the kinetic velocity of a continuous electron beam, causing the beam to oscillate before being chopped into pulses by an aperture. The RF phase velocity is substantially independent of RF frequency and amplitude, thereby enabling independent tuning of the electron pulse widths and repetition rate. The TWMCS further comprises an electron pulse picker (EPP) that applies a pulsed transverse electric field across the TWMCS to deflect electrons out of the beam, allowing only selected electrons and/or groups of electrons to pass through. The EPP pulses can be synchronized with the RF traveling wave and/or with a pumping trigger of a transverse electron microscope (TEM), for example to obtain dynamic TEM images in real time.

42 ENGINEERING↗

Broad band tunable energy electron beam pulser

An electromagnetic mechanical pulser implements a transverse wave metallic comb stripline TWMCS kicker having inwardly opposing teeth structured to retard a phase velocity of an RF traveling wave propagated therethrough to match the kinetic velocity of a continuous electron beam simultaneously propagated therethrough. The kicker imposes transverse oscillations onto the beam, which is subsequently chopped into pulses by an aperture. The RF phase velocity is substantially independent of RF frequency and amplitude, thereby enabling independent tuning of the electron pulse widths and repetition rate. The exterior surface of the kicker is conductive, thereby avoiding electron charging. In embodiments, various elements of the kicker and/or aperture can be mechanically varied to provide further tuning of the pulsed electron beam. A divergence suppression section can include a mirror TWMCS and/or magnetic quadrupoles. RF can be applied to a down-selecting TWMCS downstream of the aperture to reduce the pulse repetition rate.

Jing, Chunguang↗

Chopper system for time resolved experiments with synchrotron radiation

A chopper system for time resolved pump-probe experiments with x-ray beams from a synchrotron is described. The system has three parts: a water-cooled heatload chopper, a high-speed chopper, and a millisecond shutter. The chopper system, which is installed in beamline ID09B at the European Synchrotron Radiation Facility, provides short x-ray pulses for pump-probe experiments with ultrafast lasers. The chopper system can produce x-ray pulses as short as 200 ns in a continuous beam and repeat at frequencies from 0 to 3 kHz. For bunch filling patterns of the synchrotron with pulse separations greater than 100 ns, the high-speed chopper can isolate single 100 ps x-ray pulses that are used for the highest time resolution. A new rotor in the high-speed chopper is presented with a single pulse (100 ps) and long pulse (10 {mu}s) option. In white beam experiments, the heatload of the (noncooled) high-speed chopper is lowered by a heatload chopper, which absorbs 95% of the incoming power without affecting the pulses selected by the high speed chopper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of high-energy heavy ions using piezoelectric lead zirconate titanate

The characteristics of a radiation detector fabricated with stacks of piezoelectric lead zirconate titanate (PZT) elements were studied by irradiating it with a 400 MeV/n xenon (Xe) beam for various beam pulse durations. This detector is referred to as the multilayered detector (MD). To understand the production mechanism behind the output voltage obtained from the MD, measurement of the spatial distribution of the output signals generated in the MD was attempted. It was found that the amplitude observed was dependent on the number of Xe ions per unit time and the amount of ionization loss energy of Xe ions in PZT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model of a SNS Electrostatic LEBT with a Near-Ground Beam Chopper

The low energy beam transport (LEBT) of the Spallation Neutron Source (SNS) accelerator consists of two electrostatic lenses, of which the second is split into four electrically-isolated segments. Adding fast pulsed voltages to the lens high voltage creates the transverse fields required for beam chopping. Electric sparks, however, create transients that enter the fast high-voltage switches, which are occasionally damaged and cause machine downtime. This work models a new configuration of the electrostatic LEBT, which chops the beam with four shielded, near-ground electrodes between the two lenses. The model shows that the new configuration can match the RFQ injection requirements and sufficiently deflect the beam in the phase-space using the same chopping voltages as in the baseline LEBT.

43 PARTICLE ACCELERATORS↗

Emittance studies of the Spallation Neutron Source external-antenna H{sup -} ion source

A new Allison-type emittance scanner has been built to characterize the ion sources and low energy beam transport systems at Spallation Neutron Source. In this work, the emittance characteristics of the H{sup -} beam produced with the external-antenna rf-driven ion source and transported through the two-lens electrostatic low energy beam transport are studied. The beam emittance dependence on beam intensity, extraction parameters, and the evolution of the emittance and twiss parameters over beam pulse duration are presented.

43 PARTICLE ACCELERATORS↗

Simultaneous two-dimensional laser-induced-fluorescence measurements of argon ions

Recent laser upgrades on the Hot Helicon Experiment at West Virginia University have enabled multiplexed simultaneous measurements of the ion velocity distribution function at a single location, expanding our capabilities in laser-induced fluorescence diagnostics. The laser output is split into two beams, each modulated with an optical chopper and injected perpendicular and parallel to the magnetic field. Light from the crossing point of the beams is transported to a narrow-band photomultiplier tube filtered at the fluorescence wavelength and monitored by two lock-in amplifiers, each referenced to one of the two chopper frequencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collective focusing of intense ion beam pulses for high-energy density physics applications

The collective focusing concept in which a weak magnetic lens provides strong focusing of an intense ion beam pulse carrying a neutralizing electron background is investigated by making use of advanced particle-in-cell simulations and reduced analytical models. The original analysis by Robertson [Phys. Rev. Lett. 48, 149 (1982)] is extended to the parameter regimes of particular importance for several high-energy density physics applications. The present paper investigates (1) the effects of non-neutral collective focusing in a moderately strong magnetic field; (2) the diamagnetic effects leading to suppression of the applied magnetic field due to the presence of the beam pulse; and (3) the influence of a finite-radius conducting wall surrounding the beam cross-section on beam neutralization. In addition, it is demonstrated that the use of the collective focusing lens can significantly simplify the technical realization of the final focusing of ion beam pulses in the Neutralized Drift Compression Experiment-I (NDCX-I), and the conceptual designs of possible experiments on NDCX-I are investigated by making use of advanced numerical simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion Source Development at the SNS

The Spallation Neutron Source (SNS) now routinely operates near 1 MW of beam power on target with a highly-persistent {approx}38 mA peak current in the linac and an availability of {approx}90%. The {approx}1 ms-long, 60 Hz, {approx}50 mA H{sup -} beam pulses are extracted from a Cs-enhanced, multi-cusp, RF-driven, internal-antenna ion source. An electrostatic LEBT (Low Energy Beam Transport) focuses the 65 kV beam into the RFQ accelerator. The ion source and LEBT have normally a combined availability of {approx}99%. Although much progress has been made over the last years to achieve this level of availability further improvements are desirable. Failures of the internal antenna and occasionally impaired electron dump insulators require several source replacements per year. An attempt to overcome the antenna issues with an AlN external antenna source early in 2009 had to be terminated due to availability issues. This report provides a comprehensive review of the design, experimental history, status, and description of recently updated components and future plans for this ion source. The mechanical design for improved electron dump vacuum feedthroughs is also presented, which is compatible with the baseline and both external antenna ion sources.

07 ISOTOPE AND RADIATION SOURCES↗

H{sup -} radio frequency source development at the Spallation Neutron Source

The Spallation Neutron Source (SNS) now routinely operates nearly 1 MW of beam power on target with a highly persistent {approx}38 mA peak current in the linac and an availability of {approx}90%. H{sup -} beam pulses ({approx}1 ms, 60 Hz) are produced by a Cs-enhanced, multicusp ion source closely coupled with an electrostatic low energy beam transport (LEBT), which focuses the 65 kV beam into a radio frequency quadrupole accelerator. The source plasma is generated by RF excitation (2 MHz, {approx}60 kW) of a copper antenna that has been encased with a thickness of {approx}0.7 mm of porcelain enamel and immersed into the plasma chamber. The ion source and LEBT normally have a combined availability of {approx}99%. Recent increases in duty-factor and RF power have made antenna failures a leading cause of downtime. This report first identifies the physical mechanism of antenna failure from a statistical inspection of {approx}75 antennas which ran at the SNS, scanning electron microscopy studies of antenna surface, and cross sectional cuts and analysis of calorimetric heating measurements. Failure mitigation efforts are then described which include modifying the antenna geometry and our acceptance/installation criteria. Progress and status of the development of the SNS external antenna source, a long-term solution to the internal antenna problem, are then discussed. Currently, this source is capable of delivering comparable beam currents to the baseline source to the SNS and, an earlier version, has briefly demonstrated unanalyzed currents up to {approx}100 mA (1 ms, 60 Hz) on the test stand. In particular, this paper discusses plasma ignition (dc and RF plasma guns), antenna reliability, magnet overheating, and insufficient beam persistence.

43 PARTICLE ACCELERATORS↗

A low energy beam transport system for proton beam

A low energy beam transport (LEBT) system has been built for a compact pulsed hadron source (CPHS) at Tsinghua University in China. The LEBT, consisting of two solenoids and three short-drift sections, transports a pulsed proton beam of 60 mA of energy of 50 keV to the entrance of a radio frequency quadrupole (RFQ). Measurement has shown a normalized RMS beam emittance less than 0.2 {pi} mm mrad at the end of the LEBT. Beam simulations were carried out to compare with the measurement and are in good agreement. Based on the successful CPHS LEBT development, a new LEBT for a China ADS projector has been designed. The features of the new design, including a beam chopper and beam simulations of the LEBT are presented and discussed along with CPHS LEBT development in this article.

43 PARTICLE ACCELERATORS↗

Enhancement of beam pulse controllability for a single-pulse formation system of a cyclotron

The single-pulse formation technique using a beam chopping system consisting of two types of high-voltage beam kickers was improved to enhance the quality and intensity of the single-pulse beam with a pulse interval over 1 μs at the Japan Atomic Energy Agency cyclotron facility. A contamination rate of neighboring beam bunches in the single-pulse beam was reduced to less than 0.1%. Long-term purification of the single pulse beam was guaranteed by the well-controlled magnetic field stabilization system for the cyclotron magnet. Reduction of the multi-turn extraction number for suppressing the neighboring beam bunch contamination was achieved by restriction of a beam phase width and precise optimization of a particle acceleration phase. In addition, the single-pulse beam intensity was increased by a factor of two or more by a combination of two types of beam bunchers using sinusoidal and saw-tooth voltage waveforms. Provision of the high quality intense single-pulse beam contributed to improve the accuracy of experiments for investigation of scintillation light time-profile and for neutron energy measurement by a time-of-flight method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-high vacuum compatible optical chopper system for synchrotron x-ray scanning tunneling microscopy

High-speed beam choppers are a crucial part of time-resolved x-ray studies as well as a necessary component to enable elemental contrast in synchrotron x-ray scanning tunneling microscopy (SX-STM). However, many chopper systems are not capable of operation in vacuum, which restricts their application to x-ray studies with high photon energies, where air absorption does not present a significant problem. To overcome this limitation, we present a fully ultra-high vacuum (UHV) compatible chopper system capable of operating at variable chopping frequencies up to 4 kHz. The lightweight aluminum chopper disk is coated with Ti and Au films to provide the required beam attenuation for soft and hard x-rays with photon energies up to about 12 keV. The chopper is used for lock-in detection of x-ray enhanced signals in SX-STM.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of an implantable dosimeter for single-point water equivalent path length verification in proton therapy

Purpose: In vivo range verification in proton therapy is highly desirable. A recent study suggested that it was feasible to use point dose measurement for in vivo beam range verification in proton therapy, provided that the spread-out Bragg peak dose distribution is delivered in a different and rather unconventional manner. In this work, the authors investigate the possibility of using a commercial implantable dosimeter with wireless reading for this particular application. Methods: The traditional proton treatment technique delivers all the Bragg peaks required for a SOBP field in a single sequence, producing a constant dose plateau across the target volume. As a result, a point dose measurement anywhere in the target volume will produce the same value, thus providing no information regarding the water equivalent path length to the point of measurement. However, the same constant dose distribution can be achieved by splitting the field into a complementary pair of subfields, producing two oppositely ''sloped'' depth-dose distributions, respectively. The ratio between the two distributions can be a sensitive function of depth and measuring this ratio at a point inside the target volume can provide the water equivalent path length to the dosimeter location. Two types of field splits were used in the experiment, one achieved by the technique of beam current modulation and the other by manipulating the location and width of the beam pulse relative to the range modulator track. Eight MOSFET-based implantable dosimeters at four different depths in a water tank were used to measure the dose ratios for these field pairs. A method was developed to correct the effect of the well-known LET dependence of the MOSFET detectors on the depth-dose distributions using the columnar recombination model. The LET-corrected dose ratios were used to derive the water equivalent path lengths to the dosimeter locations to be compared to physical measurements. Results: The implantable dosimeters measured the dose ratios with a reasonable relative uncertainty of 1%-3% at all depths, except when the ratio itself becomes very small. In total, 55% of the individual measurements reproduced the water equivalent path lengths to the dosimeters within 1 mm. For three dosimeters, the difference was consistently less than 1 mm. Half of the standard deviations over the repeated measurements were equal or less than 1 mm. Conclusions: With a single fitting parameter, the LET-correction method worked remarkably well for the MOSFET detectors. The overall results were very encouraging for a potential method of in vivo beam range verification with millimeter accuracy. This is sufficient accuracy to expand range of clinical applications in which the authors could use the distal fall off of the proton depth dose for tight margins.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for lepton-flavor-violating rare muon processes

A new approach to seeking three lepton-flavor-violating rare muon processes ({mu} {sup {yields}}e conversion, {mu} {sup {yields}}e + {gamma}, and {mu} {sup {yields}}3e) on the basis of a single experimental facility is proposed. This approach makes it possible to improve the sensitivity level of relevant experiments by factors of 10{sup 5}, 600, and 300 for, respectively, the first, the second, and the third of the above processes in relation to the existing experimental level. The approach is based on employing a pulsed proton beam and on combining a muon source and the detector part of the facility into a unified magnetic system featuring a nonuniform field. A new detector design involving separate units andmaking it possible to study all three muonic processes at a single facility that admits a simple rearrangement of the detectors used is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Temporal Current Modulation on the Tracking Force Acting on a Relativistic Electron Beam in an Ohmic Plasma Channel

The effect of the current rise time in a relativistic electron beam pulse on the tracking force exerted by the low-conductivity Ohmic plasma channel on the beam has been analyzed using the “hard” beam model. It is shown using numerical analysis that an increase in the beam current rise time substantially reduces the tracking force considered here.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗