RESULTS OF BACKGROUND SUBTRACTION TECHNIQUES ON THE SPALLATION NEUTRON SOURCE BEAM LOSS MONITORS

Recent improvements to the Spallation Neutron Source (SNS) beam loss monitor (BLM) designs have been made with the goal of significantly reducing background noise. This paper outlines this effort and analyzes the results. The significance of this noise reduction is the ability to use the BLM sensors [1], [2], [3] distributed throughout the SNS accelerator as a method to monitor activation of components as well as monitor beam losses.

Beam Loss Monitor↗

An Online Beam Loss Monitor for NSLS-II Storage Ring

Reliable beam loss monitors are important tools for the safe operation of the accelerators. Beam loss monitors provide valuable information on the magnitude and location of the particle beam loss inside the accelerator enclosures. In the synchrotron radiation facilities, the electron accelerator enclosures experience a mixed radiation environment, consisting of low energy x-ray background along with bremsstrahlung and photoneutrons.

36 MATERIALS SCIENCE↗

The LCLS Undulator Beam Loss Monitor Readout System

The LCLS Undulator Beam Loss Monitor System is required to detect any loss radiation seen by the FEL undulators. The undulator segments consist of permanent magnets which are very sensitive to radiation damage. The operational goal is to keep demagnetization below 0.01% over the life of the LCLS. The BLM system is designed to help achieve this goal by detecting any loss radiation and indicating a fault condition if the radiation level exceeds a certain threshold. Upon reception of this fault signal, the LCLS Machine Protection System takes appropriate action by either halting or rate limiting the beam. The BLM detector consists of a PMT coupled to a Cherenkov radiator located near the upstream end of each undulator segment. There are 33 BLMs in the system, one per segment. The detectors are read out by a dedicated system that is integrated directly into the LCLS MPS. The BLM readout system provides monitoring of radiation levels, computation of integrated doses, detection of radiation excursions beyond set thresholds, fault reporting and control of BLM system functions. This paper describes the design, construction and operational performance of the BLM readout system.

43 PARTICLE ACCELERATORS↗

FPGA Architectures for Distributed ML Systems for Real-time Beam Loss De-blending

The Accelerator Real-time Edge AI for Distributed Systems (READS) project’s goal is to create a Artificial Intelligence (AI) system for real-time beam loss de-blending within the accelerator enclosure, which houses two accelerators: the Main Injector (MI) and the Recycler Ring (RR). In periods of joint operation, when both machines contain high intensity beam, radioactive beam losses from MI and RR overlap on the enclosure’s beam loss monitoring Beam Loss Monitor (BLM) system, making it difficult to attribute those losses to a single machine. Incorrect diagnoses result in unnecessary downtime that incurs both financialand experimental cost. The ML system will automatically disentangle each machine’s contributions to those measured losses, while not disrupting the existing operations-critical functions of the BLM system. This paper will focus on the evolution of the architectures, which provided the high-frequency, low-latency collection of synchronized data streams to make real-time inferences. The ML models, used for learning both local and global machine signatures and producing high quality inferences based on raw BLM loss measurements, will only be discussed at a high-level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The upgraded data acquisition system for beam loss monitoring at the Fermilab Tevatron and Main Injector

A VME-based data acquisition system for beam-loss monitors has been developed and is in use in the Tevatron and Main Injector accelerators at the Fermilab complex. The need for enhanced beam-loss protection when the Tevatron is operating in collider-mode was the main driving force for the new design. Prior to the implementation of the present system, the beam-loss monitor system was disabled during collider operation and protection of the Tevatron magnets relied on the quench protection system. The new Beam-Loss Monitor system allows appropriate abort logic and thresholds to be set over the full set of collider operating conditions. The system also records a history of beam-loss data prior to a beam-abort event for post-abort analysis. Installation of the Main Injector system occurred in the fall of 2006 and the Tevatron system in the summer of 2007. Both systems were fully operation by the summer of 2008. In this paper we report on the overall system design, provide a description of its normal operation, and show a number of examples of its use in both the Main Injector and Tevatron.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signal Processing for Beam Loss Monitor System at Jefferson Lab

Ion Chamber and Photomultiplier Tube (PMT) are both used for beam loss monitor in the Machine Protection System (MPS) at Jefferson Lab. The requirements of signal processing of these detectors are different, so two VME-based signal processing boards, Beam Loss Monitor (BLM) board and Ion-Chamber board, were developed. The BLM board has fast response (< 1us) and 5 decades dynamic range from 10nA to 1 mA, while the Ion-Chamber board has 8 decades dynamic range from 100 pA to 10 mA and slower response. Both of boards provide functions of machine protection and beam diagnostics, and features of fast shutdown (FSD) interface, beam sync interface, built-in-self-test, remotely controlled bias signals, and on-board memory buffer.

Yan, J.↗

Signal Processing Board for Beam Loss Monitors

This paper describes a new VME based machine protection Beam Loss Monitor (BLM) signal processing board designed at Jefferson Lab which features high sensitivity, high resolution, and low cost per channel. This double-wide VME board provides eight-channel signal processing with each channel having linear, logarithmic, and integrating amplifiers that simultaneously provide the optimal signal processing for both machine protection and beam diagnostics. Amplified signals are independently sampled by 16-bit, fast ADCs and then further processed through a Field Programmable Gate Array (FPGA). It also has features of fast shutdown interface (FSD), beam sync interface, built-in-self-test, remotely controlled bias signals, and on-board memory buffer. The initial experimental test shows that the BLM board has fast response (<< 1us) for integrating and wide dynamic range from 10 nA to 1 mA (>50 dB) for logarithmic signals. The board is suitable for signal processing from photomultiplier (PMT) and ion chamber detectors. Notice: Authored by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177. The U.S. Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce this manuscript for U.S. Government purposes.

Yan, Jianxun↗

New Beam Loss Monitor for 12 GeV Upgrade

This paper describes a new VME based machine protection Beam Loss Monitor (BLM) signal processing board designed at Jefferson Lab to replace the current CAMAC based BLM board. The new eight-channel BLM signal processor has linear, logarithmic, and integrating amplifiers that simultaneously provide the optimal signal processing for each application. Amplified signals are digitized and then further processed through a Field Programmable Gate Array (FPGA). Combining both the diagnostic and machine protection functions in each channel allows the operator to tune-up and monitor beam operations while the machine protection is integrating the same signal. Other features include extensive built-in-self-test, fast shutdown interface (FSD), and 16-Mbit buffers for beam loss transient play-back. The new VME BLM board features high sensitivity, high resolution, and low cost per channel.

43 PARTICLE ACCELERATORS↗

OPERATIONAL EXPERIENCE WITH FAST FIBER-OPTIC BEAM LOSS MONITORS FOR THE ADVANCED PHOTON SOURCE STORAGE RING SUPERCONDUCTING UNDULATORS

Fast fiber-optic (FFO) beam loss monitors (BLMs) installed with the first two superconducting undulators (SCUs) in the Advanced Photon Source storage ring have proven to be a useful diagnostic for measuring deposited charge (energy) during rapid beam loss events. The first set of FFOBLMs were installed outside the cryostat of the short SCU, a 0.33-m long device, above and below the beam centerline. The second set are mounted with the first 1.1-mlong SCU within the cryostat, on the outboard and inboard sides of the vacuum chamber. The next 1.1-m-long SCU is scheduled to replace the short SCU later in 2016 and will be fitted with FFOBLMs in a manner similar to original 1.1-m device. The FFOBLMs were employed to set timing and voltage for the abort kicker (AK) system. The AK helps to prevent quenching of the SCUs during beam dumps [1] by directing the beam away from the SC magnet windings. The AK is triggered by the Machine Protection System (MPS). In cases when the AK fails to prevent quenching, the FFOBLMs show that losses often begin before detection by the MPS.

Dooling, J.↗

Beam Loss Monitors for NSLS-II Storage Ring

The shielding for the NSLS-II storage ring will provide adequate protection for the full injected beam losses in two cells of the ring around the injection point, but the remainder of the ring is shielded for lower losses of <10% top-off injection beam current. This will require a system to insure that beam losses do not exceed levels for a period of time that could cause excessive radiation exposure outside the shield walls. This beam Loss Control and Monitoring system will have beam loss monitors that will measure where the beam charge is lost around the ring, to warn operators if losses approach the design limits. To measure the charge loss quantitatively, we propose measuring the electron component of the shower as beam electrons hit the vacuum chamber (VC) wall. This will be done using the Cerenkov light as electrons transit ultra-pure fused silica rods placed close to the inner edge of the VC. The entire length of the rod will collect light from the electrons of the spread out shower resulting from the small glancing angle of the lost beam particles to the VC wall. The design and measurements results of the prototype Cerenkov BLM will be presented.

43 PARTICLE ACCELERATORS↗

Calibration of Fast Fiber-Optic Beam Loss Monitors for the Advanced Photon Source Storage Ring Superconducting Undulators

We report on the calibration and use of fast fiber-optic (FO) beam loss monitors (BLMs) in the Advanced Photon Source storage ring (SR). A superconducting undulator prototype (SCU0) has been operating in SR Sector 6 (“ID6”) since the beginning of CY2013, and another undulator SCU1 (a 1.1-m length undulator that is three times the length of SCU0) is scheduled for installation in Sector 1 (“ID1”) in 2015. The SCU0 main coil often quenches during beam dumps. MARS simulations have shown that relatively small beam loss (<1 nC) can lead to temperature excursions sufficient to cause quenchingwhen the SCU0windings are near critical current. To characterize local beam losses, high-purity fused-silica FO cables were installed in ID6 on the SCU0 chamber transitions and in ID1 where SCU1 will be installed. These BLMs aid in the search for operating modes that protect the SCU structures from beam-loss-induced quenching. In this paper, we describe the BLM calibration process that included deliberate beam dumps at locations of BLMs. We also compare beam dump events where SCU0 did and did not quench.

Dooling, J.↗

Monte Carlo Studies of the Radiation Fields in the Linac Coherent Light Source Undulators and of the Corresponding Signals in the Cerenkov Beam Loss Monitors

In 2009 the Linac Coherent Light Source (LCLS) at the SLAC National Accelerator Center started free electron laser (FEL) operation. In order to continue to produce the bright and short-pulsed x-ray laser demanded by FEL scientists, this pioneer hard x-ray FEL requires a perfectly tailored magnetic field at the undulators, so that the photons generated at the electron wiggling path interact at the right phase with the electron beam. In such a precise system, small (>0.01%) radiation-induced alterations of the magnetic field in the permanent magnets could affect FEL performance. This paper describes the simulation studies of radiation fields in permanent magnets and the expected signal in the detectors. The transport of particles from the radiation sources (i.e. diagnostic insert) to the undulator magnets and to the beam loss monitors (BLM) was simulated with the intra nuclear cascade codes FLUKA and MARS15. In order to accurately reproduce the optics of LCLS, lattice capabilities and magnetic fields were enabled in FLUKA and betatron oscillations were validated against reference data. All electron events entering the BLMs were printed in data files. The paper also introduces the Radioactive Ion Beam Optimizer (RIBO) Monte Carlo 3-D code, which was used to read from the event files, to compute Cerenkov production and then to simulate the optical coupling of the BLM detectors, accounting for the transmission of light through the quartz.

COMP, SAFETY, XFEL, OTHER↗

Injection Beam Loss Monitor for NSLS-II Radiation Protection

The NSLS-II with its high stored beam energy operation and top-off injection, make the radiation protection a critical issue. The radiation shield wall of the tunnel is being designed to be adequate for a 10% loss of the injection current (l.4nC/min) at any one location. The injection region is shielded for 100% injection losses (14nC/min). This thinner shielding around the ring is a concern should the beam develop high current instabilities, that would cause the beam to dump or develop a very short lifetime. In order to overcome these instabilities, studies and operations in the high current conditions that might drive these instabilities would be required. If the radiation shielding would not allow operation at these currents, then the ability to study and correct these instabilities may not be allowed or at least not without greatly restriction the users access to the experimental floor. We propose a detector that could be used to quantify the amount of charge (DC current) lost around the ring, verifying that beam losses didn't exceed the design levels. This would then allow the beam to be refilled for operations and/or studies without regard to the experimental floor occupancy. In a earlier Tech Note we proposed a method to control the location of the beam dumped during intentional (interlock trips) and unintentional beam losses, this Tech Note will deal mostly with accounting for beam lost during injection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam Loss Monitoring with Fixed and Translating Scintillation Detectors Along the Fermilab Drift-tube Linac

The Fermilab Linac is a roughly 145 meter linear accelerator that accelerates H- beam from 750 keV to 400 MeV and provides beam for the Booster and the rest of the accelerator chain. The first section of the Linac is a Drift-Tube Linac (DTL), which in its current state, suffers from a lack of instrumentation along its length. As a result, operational staff do not have access to the diagnostic information needed to tune the critical components of this accelerator, such as the quadrupole magnets within the drift tubes. This work presents an effort to utilize both fixed and translating scintillation detectors to investigate beam loss along the first two cavities of the DTL.

43 PARTICLE ACCELERATORS↗

A novel digitization scheme with FPGA-base TDC for beam loss monitors operating at cryogenic temperature

Recycling integrators are common current-to-frequency converting circuits for measurements of low current such as that produced by Fermilab's cryogenic ionization chambers. In typical digitization/readout schemes, a counter is utilized to accumulate the number of pulses generated by the recycling integrator to adequately digitize the total charge. In order to calculate current with reasonable resolution (e.g., 7-8 bits), hundreds of pulses must be accumulated which corresponds to a long sampling period, i.e., a very low sampling rate. In our new scheme, an FPGA-based Time-to-Digital Convertor (TDC) is utilized to measure the time intervals between the pulses output from the recycling integrator. Using this method, a sample point of the current can be made with good resolution (>10 bits) for each pulse. This effectively increases the sampling rates by hundreds of times for the same recycling integrator front-end electronics. This scheme provides a fast response to the beams loss and is potentially suitable for accelerator protection applications. Moreover, the method is also self-zero-suppressed, i.e., it produces more data when the beam loss is high while it produces significantly less data when the beam loss is low.

43 PARTICLE ACCELERATORS↗