Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM EMITTANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Investigation of Beam Emittance and Beam Transport Line Optics on Polarization

Effects of beam emittance, energy spread, optical parameters and magnet misalignment on beam polarization through particle transport systems are investigated. Particular emphasis will be placed on the beam lines being used at Fermilab for the development of the muon beam for the Muon g-2 experiment, including comparisons with the natural polarization resulting from pion decay, and comments on the development of systematic correlations among phase space variables.

43 PARTICLE ACCELERATORS↗

Influence of injection beam emittance on beam transmission efficiency in a cyclotron

The JAEA AVF cyclotron accelerates various kinds of high-energy ion beams for research in biotechnology and materials science. Beam intensities of an ion species of the order of 10{sup −9}–10{sup −6} ampere are often required for various experiments performed sequentially over a day. To provide ion beams with sufficient intensity and stability, an operator has to retune an ion source in a short time. However, the beam intensity downstream of the cyclotron rarely increases in proportion to the intensity at the ion source. To understand the cause of this beam behavior, transmission efficiencies of a {sup 12}C{sup 5+} beam from an electron cyclotron resonance ion source to the cyclotron were measured for various conditions of the ion source. Moreover, a feasible region for acceleration in the emittance of the injection beam was clarified using a transverse-acceptance measuring system. We confirmed that the beam emittance and profile were changed depending on the condition of the ion source and that matching between the beam emittance and the acceptance of the cyclotron was degraded. However, after fine-tuning to improve the matching, beam intensity downstream of the cyclotron increased.

43 PARTICLE ACCELERATORS↗

Effect of beam emittance on self-modulation of long beams in plasma wakefield accelerators

The initial beam emittance determines the maximum wakefield amplitude that can be reached as a result of beam self-modulation in the plasma. The wakefield excited by the fully self-modulated beam decreases linearly with the increase in the beam emittance. There is a value of initial emittance beyond which the self-modulation does not develop even if the instability is initiated by a strong seed perturbation. The emittance scale at which the wakefield is suppressed by a factor of two with respect to the zero-emittance case (the so called critical emittance) is determined by inability of the excited wave to confine beam particles radially and is related to beam and plasma parameters by a simple formula. The effect of beam emittance can be observed in several discussed self-modulation experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Studies of Beam Intensity Effects in Fermilab Booster Synchrotron. Part II: Beam Emittance Evolution

Detrimental beam dynamics effects limit performance of high intensity rapid cycling synchrotrons (RCS) such as the 8 GeV Fermilab Booster. Here we report the results of comprehensive studies of various beam intensity dependent effects in the Booster. In the previous publication we presented the dependencies of the Booster beam intensity losses on the total number of protons per pulse and on key operational parameters such as the machine tunes and chromaticities. Here we discuss two methods of the Booster beam emittance measurements (the multi-wires proportional chambers and the ionization profile monitors), analyze the intensity dependent emittance growth effects and discuss the ultimate performance of the machine now and after foreseen and proposed upgrades.

43 PARTICLE ACCELERATORS↗

Beam emittance preservation using Gaussian density ramps in a beam-driven plasma wakefield accelerator

A current challenge that is facing the plasma wakefield accelerator (PWFA) community is transverse beam emittance preservation. This can be achieved by balancing the natural divergence of the beam against the strong focusing force provided by the PWFA plasma source in a scheme referred to as beam matching. One method to accomplish beam matching is through the gradual focusing of a beam with a plasma density ramp leading into the bulk plasma. Here, the beam dynamics in a Gaussian plasma density ramp are considered, and an empirical formula is identified that gives the ramp length and beam vacuum waist location needed to achieve near-perfect matching. The method uses only the beam vacuum waist beta function as an input. Numerical studies show that the Gaussian ramp focusing formula is robust for beta function demagnification factors spanning more than an order of magnitude with experimentally favourable tolerances for future PWFA research facilities. This article is part of the Theo Murphy meeting issue ‘Directions in particle beam-driven plasma wakefield acceleration’.

43 PARTICLE ACCELERATORS↗

Proton beam emittance growth in multipicosecond laser-solid interactions

High intensity laser-solid interactions can accelerate high energy, low emittance proton beams via the target normal sheath acceleration (TNSA) mechanism. Such beams are useful for a number of applications, including time-resolved proton radiography for basic plasma and high energy density physics studies. In experiments using the OMEGA EP laser system, we perform the first measurements of TNSA proton beams generated by up to 100 ps, kilojoule-class laser pulses with relativistic intensities. By systematically varying the laser pulse duration, we measure degradation of the accelerated proton beam quality as the pulse length increases. Two dimensional particle-in-cell simulations and simple scaling arguments suggest that ion motion during the rise time of the longer pulses leads to extended preformed plasma expansion from the rear target surface and strong filamentary field structures which can deflect ions away from uniform trajectories and therefore lead to large emittance growth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fermilab Booster Beam Emittances from Quadrupole Modes Measured BPMs

The measurement of beam emittances by extracting the quadrupole mode signal from a 4 plate beam position monitor (BPM) was published at least 40 years ago. Unfortunately, in practice, this method suffers from poor signal to noise ratio and requires a lot of tuning to extract out the emittances. In this paper, an improved method where multiple BPMs are used together with better mathematical analysis is described. The BPM derived emittances are then compared with those measured by the Ion Profile Monitor (IPM). Surprisingly, the BPM measured emittances behave very well and are more realistic than those measured by the IPM.

43 PARTICLE ACCELERATORS↗

Beam emittance measurements and simulations of injector line for radio frequency quadrupole

A 400 keV deuteron (D{sup +}) radio frequency quadrupole (RFQ) accelerator has been designed, built, and commissioned at the Bhabha Atomic Research Centre, India. A beam line has been developed for injecting deuterons into the 400 keV RFQ. This comprises of a RF plasma ion source and a low energy beam transport (LEBT) system, consisting of two solenoid magnets and two steerer magnets. The ion source is characterized in terms of transverse beam emittance. A slit-wire scanner based emittance measurement setup has been developed for the transverse emittance measurements of H{sup +} and D{sup +} beams. The measured emittance values are found to be well within the acceptance value for the RFQ. These measured emittance parameters are used to optimize the solenoid fields in LEBT to match the beam from the ion source to RFQ. TRACEWIN simulation code is used for the beam transport simulations. The simulations show 99% transmission of D{sup +} beam through the RFQ, while 95% transmission has been measured experimentally.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fermilab Booster Beam Emittances from Quadrupole Modes Measured by BPMs

The measurement of beam emittances by extracting the quadrupole mode signal from a 4 plate beam position monitor (BPM) was published at least 40 years ago. Unfortunately, in practice, this method suffers from poor signal to noise ratio and requires a lot of tuning to extract out the emittances. In this paper, an improved method where multiple BPMs are used together with better mathematical analysis is described. The BPM derived emittances are then compared with those measured by the Ion Profile Monitor (IPM). Surprisingly, the BPM measured emittances behave very well and are more realistic than those measured by the IPM.

43 PARTICLE ACCELERATORS↗

A real-time phase-space beam emittance monitoring system

An electron beam position and angle monitoring system, ps-BPM, has been shown to be able to measure the electron source position and angle at a single location in a beamline at a synchrotron source. This system uses a monochromator to prepare a photon beam whose energy is at that of the K -edge of an absorber filter. The divergence of the beam from the source gives an energy range that will encompass the K -edge of the filter. A measurement of the centre of the monochromatic beam and the K -edge location through the absorber filter gives the position and angle of the electron source. Here, it is shown that this system is also capable of measuring the source size and divergence at the same time. This capability is validated by measurement as the beam size in the storage ring was changed and by ray-tracing simulations. The system operates by measuring the photon beam spatial distribution as well as a K -edge filtered beam distribution. These additional measurements result in the ability to also determine the electron source size and divergence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Absolute beam emittance measurements at RHIC using ionization profile monitors

In the past, comparisons between emittance measurements obtained using ionization profile monitors, Vernier scans (using as input the measured rates from the zero degree counters, or ZDCs), the polarimeters and the Schottky detectors evidenced significant variations of up to 100%. In this report we present studies of the RHIC ionization profile monitors (IPMs). After identifying and correcting for two systematic instrumental errors in the beam size measurements, we present experimental results showing that the remaining dominant error in beam emittance measurements at RHIC using the IPMs was imprecise knowledge of the local beta functions. After removal of the systematic errors and implementation of measured beta functions, precise emittance measurements result. Also, consistency between the emittances measured by the IPMs and those derived from the ZDCs was demonstrated.

43 PARTICLE ACCELERATORS↗

Rematching AGS Booster synchrotron injection lattice for smaller transverse beam emittances

The polarized proton beam is injected into the booster via the charge-exchange (H- to H+) scheme. The emittance growth due to scattering at the stripping foil is proportional to the beta functions at the foil. It was demonstrated that the current scheme of reducing the beta functions at the stripping foil preserves the emittance better; however the betatron tunes are above but very close to half integer. Due to concern of space charge and half integer in general, options of lattice designs aimed towards reducing the beta functions at the stripping foil with tunes at more favorable places are explored.

43 PARTICLE ACCELERATORS↗

Intrinsic beam emittance of laser-accelerated electrons measured by x-ray spectroscopic imaging

Here, the recent combination of ultra-intense lasers and laser-accelerated electron beams is enabling the development of a new generation of compact x-ray light sources, the coherence of which depends directly on electron beam emittance. Although the emittance of accelerated electron beams can be low, it can grow due to the effects of space charge during free-space propagation. Direct experimental measurement of this important property is complicated by micron-scale beam sizes, and the presence of intense fields at the location where space charge acts. Reported here is a novel, non-destructive, single-shot method that overcame this problem. It employed an intense laser probe pulse, and spectroscopic imaging of the inverse-Compton scattered x-rays, allowing measurement of an ultra-low value for the normalized transverse emittance, 0.15 (±0.06) π mm mrad, as well as study of its subsequent growth upon exiting the accelerator. The technique and results are critical for designing multi-stage laser-wakefield accelerators, and generating high-brightness, spatially coherent x-rays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron beam emittance at operational intensity in fourth-generation synchrotron light sources

For synchrotron light sources, the brightness of user X-ray beams is primarily determined by the electron beam emittance and energy spread at operational intensity. A common feature of fourth-generation synchrotrons is the short length of electron bunches combined with a very small transverse beam size. Consequently, the particle density is much higher than in machines of previous generations, leading to strong collective effects that significantly increase the emittance and limit the achievable brightness at operational beam intensity. In this article, we summarize our studies of the emittance scaled with the beam energy and intensity, taking into account the effects of intrabeam scattering, beam-impedance interaction, and bunch lengthening provided by higher-harmonic RF systems, to identify optimal combinations of machine and beam parameters.

43 PARTICLE ACCELERATORS↗

PyEmittance: A General Python Package for Particle Beam Emittance Measurements With Adaptive Quadrupole Scans [Poster]

We present PyEmittance: a new Python package for general particle beam emittance measurements that offers adaptive quadrupole scans and is designed for robust and flexible integration with Python-based software, with online accelerators, and with simulation software. It is open source software, and can be installed via the command pip install pyemittance.

43 PARTICLE ACCELERATORS↗

Ultra-low emittance beam generation using two-color ionization injection in a CO 2 laser-driven plasma accelerator

Ultra-low emittance (tens of nm) beams can be generated in a plasma accelerator using ionization injection of electrons into a wakefield. An all-optical method of beam generation uses two laser pulses of different colors. A long-wavelength drive laser pulse (with a large ponderomotive force and small peak electric field) is used to excite a large wakefield without fully ionizing a gas, and a short-wavelength injection laser pulse (with a small ponderomotive force and large peak electric field), co-propagating and delayed with respect to the pump laser, to ionize a fraction of the remaining bound electrons at a trapped wake phase, generating an electron beam that is accelerated in the wake. The trapping condition, the ionized electron distribution, and the trapped bunch dynamics are discussed. Expressions for the beam transverse emittance, parallel and orthogonal to the ionization laser polarization, are presented. An example is shown using a 10-micron CO 2 laser to drive the wake and a frequency-doubled Ti:Al 2 O 3 laser for ionization injection.

43 PARTICLE ACCELERATORS↗

Beam emittance reduction during operation of Indus-2

Indus-2 storage ring is a 2.5 GeV third generation synchrotron radiation source. This source was commissioned using a moderate optics. Beam injection was accomplished using an off momentum electron beam to avoid difficulties faced in storage of beam at 550 MeV. The injection procedure and relevant beam dynamical studies are discussed. The switch over from the moderate optics to low emittance optics is done at 2.5 GeV after storing the electron beam. The procedure evolved to reduce the beam emittance and its implementation during the operation is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗