SEARCH · Engineering Papers
Results for “BEAM COLUMN”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Neutron capture measurements at UMass lowell research reactor
A new facility was designed around the thermal column beam port of the 1 MW Research Reactor at the University of Massachusetts Lowell. Thermal neutrons are collimated to a 1-inch diameter beam and incident on samples to induce the radiative neutron capture. New measurements of capture gamma rays are planned for Mn, Cu, Ni, Cr, and Gd samples in the next few years. The experiments will be carried out in close collaboration with the ENSDF (Evaluated Nuclear Structure Data File) evaluation group at Brookhaven National Laboratory. The gamma rays are measured using an array of high-resolution HPGe detectors. Some of the HPGe detectors use active Compton shields that were designed from scintillation detectors and improve significantly the signal-to-background in the measured gamma-ray spectra with HPGe. The experimental spectra will be validated by the GEANT4 simulations of the array and theoretical models of the emission of gamma rays from the compound nucleus. In conclusion, the new experimental results on the capture gamma ray intensities will be incorporated in future ENSDF evaluations.
Towards Construction of a Novel Nanometer-Resolution MeV-STEM for Imaging Thick Frozen Biological Samples
Driven by life-science applications, a mega-electron-volt Scanning Transmission Electron Microscope (MeV-STEM) has been proposed here to image thick frozen biological samples as a conventional Transmission Electron Microscope (TEM) may not be suitable to image samples thicker than 300–500 nm and various volume electron microscopy (EM) techniques either suffering from low resolution, or low speed. The high penetration of inelastic scattering signals of MeV electrons could make the MeV-STEM an appropriate microscope for biological samples as thick as 10 μm or more with a nanoscale resolution, considering the effect of electron energy, beam broadening, and low-dose limit on resolution. The best resolution is inversely related to the sample thickness and changes from 6 nm to 24 nm when the sample thickness increases from 1 μm to 10 μm. To achieve such a resolution in STEM, the imaging electrons must be focused on the specimen with a nm size and an mrad semi-convergence angle. This requires an electron beam emittance of a few picometers, which is ~1000 times smaller than the presently achieved nm emittance, in conjunction with less than 10 -4 energy spread and 1 nA current. We numerically simulated two different approaches that are potentially applicable to build a compact MeV-STEM instrument: (1) DC (Direct Current) gun, aperture, superconducting radio-frequency (SRF) cavities, and STEM column; (2) SRF gun, aperture, SRF cavities, and STEM column. Beam dynamic simulations show promising results, which meet the needs of an MeV-STEM, a few-picometer emittance, less than 10 -4 energy spread, and 0.1–1 nA current from both options. Also, we designed a compact STEM column based on permanent quadrupole quintuplet, not only to demagnify the beam size from 1 μm at the source point to 2 nm at the specimen but also to provide the freedom of changing the magnifications at the specimen and a scanning system to raster the electron beam across the sample with a step size of 2 nm and the repetition rate of 1 MHz. This makes it possible to build a compact MeV-STEM and use it to study thick, large-volume samples in cell biology.
Bim-to-fea Conversion Program
The purpose of this program is to enable interoperability between BIM-based architectural design software (i.e., Revit, ArchiCAD, AVEVA E3D) to structural analysis software (i.e., SAP2000). The program takes in BIM building model data via the IFC file format, automatically transforms the architectural coordination entities (structural beams, columns, slabs, walls) to structural analysis entities (i.e., finite element space frames and shells), automatically adjusts the connectivity of the structural analysis entities, and finally exports the structural analysis entities as a structural analysis model contained within a new IFC file. For example, a 3D building in Revit can be exported to an IFC file, run through this BIM-to-FEA program, then the exported IFC can be inputted into SAP2000.
Stable electron beam propagation in a plasma column
The stability of plasma-based accelerators against transverse misalignments and asymmetries of the drive beam is crucial for their applicability. Without stabilizing mechanisms, even small initial offsets of the drive beam centroid can couple coherently to the plasma wake, grow, and ultimately lead to emittance degradation or beam loss for a trailing witness beam. In this work, we demonstrate the intrinsic stability of a beam propagating in a plasma column. This result is relevant in the context of plasma-based positron acceleration, where a wakefield suitable for the transport and acceleration of a positron witness beam is generated in a plasma column by means of an electron drive beam. The stable propagation of the drive beam is a necessary condition for the experimental implementation of this scheme. The differences and similarities of stabilizing mechanisms in a plasma column compared to a homogeneous plasma are identified via theory and particle-in-cell simulations. Experimental tolerances are given, demonstrating the experimental feasibility of the scheme.
Mitigation of space charge effects using electron column at IOTA ring
We investigate a novel method to mitigate space charge effects of high intensity proton beams propagating in circular accelerators by means of trapping and controlling electrons generated from beam-induced residual gas ionization. This compensation method uses Coulomb repulsion force between a proton beam and electrons to mitigate self-space charge effects of the beam if it passes through a plasma column. The transverse electron-proton (e-p) instability in the plasma column is well controlled by the longitudinal magnetic field of a solenoid magnet and the bias voltages on electrodes. In this report, we will show simulation results how to control distributions of electrons and ions as well as that of the proton beam inside the column.
Numerical simulation of terahertz radiation by laser-driven plasma dipole oscillation
Laser-plasma interactions have many theoretical and technological applications. One is the use of coherently accelerated electrons to provide novel sources of THz radiation. Our research focuses on simulating the cross/self-interactions between two high intensity, ultra-short, counter propagating and detuned laser pulses and an initial neutral target for controlled ionization. Unlike our previous studies of laser-matter interaction over preformed plasma, we explore the injection and collision of laser pulses to induce background plasma driven by the self-guided laser wakefield mechanism, which is then used to perturb the plasma resulting in induced dipole oscillations leading to transverse radiation. Inducing a cylindrical spatial plasma column within the laser beam radius regime provides a stable, spatially localized plasma channel. The emitted radiation from the plasma dipole oscillation (PDO) will not be affected by surrounding plasma absorption, resulting in effective radiation distribution. Finally, results include 3D EM-PIC simulations and a comparison of the self- ionizing plasma against the preformed plasma to assess the efficiency of the mechanisms.
Comprehensive Review of DPF-based Flash Neutron Radiography Viability
MJOLNIR (MegaJOule Neutron Imaging Radiography) is a Dense Plasma Focus (DPF) being developed by LLNL as a prototype to assess the viability of a DPF as a flash neutron radiography source. To date, MJOLNIR has discharged up to 1.3 MJ of stored energy into a deuterium plasma load and achieved yields up to 1.2 × 10 12 neutrons per discharge. The MJOLNIR pulse length already meets the preliminary requirements for flash neutron radiography and we demonstrate in this report plausible paths forward to meet the yield requirement in a deuterium plasma. MJOLNIR’s neutron spot size has been characterized to be a factor of two greater than radiography requirements and presents the greatest challenge. A path forward to sufficiently shrinking spot size is outlined in this report, using a combination of gas dopants and a smaller anode implosion radius. A DPF is a plasma device with coaxial electrodes whose discharge ends with a stagnated hot and dense plasma column on-axis, at the tip of the central anode. Inside the MJOLNIR DPF plasma column, both thermal and beam target processes generate neutrons. To understand the underlying physics of neutron generation inside the DPF, we model the experiment using a combination of kinetic, fluid, and reduced-order models we have been developing for over ten years at LLNL. Our numerical tools are also pivotal to charting the path forward because they allow us to numerically test out which modifications would improve the DPF’s characteristic output.
Quantitative Electron Beam‐Single Atom Interactions Enabled by Sub‐20‐pm Precision Targeting
The ability to probe and control matter at the picometer scale is essential for advancing quantum and energy technologies. Scanning transmission electron microscopy offers powerful capabilities for materials analysis and modification, but sample damage, drift, and scan distortions hinder single atom analysis and deterministic manipulation. Materials analysis and modification via electron–solid interactions can be transformed by precise delivery of electrons to a specified atomic location, maintaining the beam position despite drift, and minimizing collateral dose. Here a fast, low-dose, sub-20-pm precision electron beam positioning technique is developed, “atomic lock-on,” (ALO), which offers the ability to position the beam on a specific atomic column without previously irradiating that column. This technique is used to lock onto a single selected atomic location to repeatedly measure its weak electron energy loss signal despite sample drift. Moreover, electron beam-matter interactions in single atomic events are measured with μ s time resolution. This enables observation of single-atom dynamics, such as atomic bistability, revealing partially bonded atomic configurations and recapture phenomena. This opens prospects for using electron microscopy for high-precision measurements and deterministic control of matter for quantum technologies.
Optimize Electron Beam Energy toward In Situ Imaging of Thick Frozen Bio-Samples with Nanometer Resolution Using MeV-STEM
To optimize electron energy for in situ imaging of large biological samples up to 10 μm in thickness with nanoscale resolutions, we implemented an analytical model based on elastic and inelastic characteristic angles. This model has been benchmarked by Monte Carlo simulations and can be used to predict the transverse beam size broadening as a function of electron energy while the probe beam traverses through the sample. As a result, the optimal choice of the electron beam energy can be realized. In addition, the impact of the dose-limited resolution was analysed. While the sample thickness is less than 10 μm, there exists an optimal electron beam energy below 10 MeV regarding a specific sample thickness. However, for samples thicker than 10 μm, the optimal beam energy is 10 MeV or higher depending on the sample thickness, and the ultimate resolution could become worse with the increase in the sample thickness. Moreover, a MeV-STEM column based on a two-stage lens system can be applied to reduce the beam size from one micron at aperture to one nanometre at the sample with the energy tuning range from 3 to 10 MeV. In conjunction with the state-of-the-art ultralow emittance electron source that we recently implemented, the maximum size of an electron beam when it traverses through an up to 10 μm thick bio-sample can be kept less than 10 nm . This is a critical step toward the in situ imaging of large, thick biological samples with nanometer resolution.
Simulation Study of High-Precision Characterization of MeV Electron Interactions for Advanced Nano-Imaging of Thick Biological Samples and Microchips
The resolution of a mega-electron-volt scanning transmission electron microscope (MeV-STEM) is primarily governed by the properties of the incident electron beam and angular broadening effects that occur within thick biological samples and microchips. A precise understanding and mitigation of these constraints require detailed knowledge of beam emittance, aberrations in the STEM column optics, and energy-dependent elastic and inelastic critical angles of the materials being examined. This simulation study proposes a standardized experimental framework for comprehensively assessing beam intensity, divergence, and size at the sample exit. This framework aims to characterize electron-sample interactions, reconcile discrepancies among analytical models, and validate Monte Carlo (MC) simulations for enhanced predictive accuracy. Our numerical findings demonstrate that precise measurements of these parameters, especially angular broadening, are not only feasible but also essential for optimizing imaging resolution in thick biological samples and microchips. By utilizing an electron source with minimal emittance and tailored beam characteristics, along with amorphous ice and silicon samples as biological proxies and microchip materials, this research seeks to optimize electron beam energy by focusing on parameters to improve the resolution in MeV-STEM/TEM. This optimization is particularly crucial for in situ imaging of thick biological samples and for examining microchip defects with nanometer resolutions. Our ultimate goal is to develop a comprehensive mapping of the minimum electron energy required to achieve a nanoscale resolution, taking into account variations in sample thickness, composition, and imaging mode.
Experimental parameters for plasma wakefield acceleration in a narrow plasma column
Recent theoretical advancements propose multiple positron acceleration schemes in plasma wakefield acceleration (PWFA). One of the most promising ideas involves the creation of an electron-driven blowout wake within a finite-radius pre-ionized plasma column. This leads to the formation of an elongated region of sheath electrons at the closing of the first wake period capable of accelerating positrons while simultaneously providing a transverse focusing force. Additionally, the proposed scheme has shown to be a potential means of suppressing instabilities. We present an experimental opportunity to explore the narrow column PWFA at the Facility for Advanced Accelerator Experimental Tests II (FACET-II): the E333 experiment. As a pivotal first step towards achieving positron acceleration in PWFA, we have planned a precursor experiment utilizing the currently available single-bunch electron beam to study the physics of the narrow plasma PWFA scheme. We outline the feasible experimental parameters, including beam and ionization laser parameters, along with the required laser optics for the experiment. The primary observable signatures for this stage of the experiment are the final energy spectrum and transverse position of the electron bunch, anticipating reduced energy loss and enhanced beam guidance in the narrow plasma column compared to the nominal PWFA. Comprehensive simulations are used to detail our experimental plan.
Neutron generation dynamics inside a MA-class dense plasma focus Z-pinch
Dense plasma focii (DPFs) are appealing as energy efficient sources of short pulses of ions, neutrons, and x rays. The output of these sources is expected to scale with input current (I4), but has been shown to drop at the MA level [S. K. H. Auluck, “On the failure of neutron yield scaling in the dense plasma focus,” Phys. Plasmas 30, 080701 (2023)]. New results on the MegaJOuLe Neutron Imaging Radiography DPF showed neutron yield production in agreement with the input current scaling beyond the previously observed drop. This work provides insight into the pinch formation on a DPF and reports on the two different mechanisms leading to neutron generation inside a DPF using a combination of kinetic simulations and experimental data. A combination of particle-in-cell (PIC) and 1D shock theory results are used to describe the pinch formation and disassembly and the corresponding thermonuclear and beam-target mechanisms. The temporal evolution of the pinch column predicted by the PIC simulations shows qualitative agreement with the experimental data from plasma photon emission as well as temporal neutron pulse shapes. In MJ-class DPFs, both thermonuclear and beam-target mechanisms can occur over the course of the implosion and contribute to the total neutron production. Hence the neutron source size of a DPF will change throughout the implosion. Experimental neutron radiographs show the increase in source size as the pinch breaks apart, in agreement with simulation's prediction.
Simulation study of ion beam used to produce Mo-99
An 820 mA CW positive ion source is being developed to produce Mo-99 using the fusion of deuterium and tritium ion beams on a rotating target to produce neutrons for use in the production of radiopharmaceuticals. The ion source consists of an RF plasma source, a multi-aperture extractor, and 300 kV accelerating column. This paper will describe a simulation study of the beam through the extractor grid and the accelerator to the target. The uniformity of beam distribution on the target is an important aspect of the simulation.
A Three-Dimensional Reconstruction Algorithm for Scanning Transmission Electron Microscopy Data from a Single Sample Orientation
Abstract Increasing interest in three-dimensional nanostructures adds impetus to electron microscopy techniques capable of imaging at or below the nanoscale in three dimensions. We present a reconstruction algorithm that takes as input a focal series of four-dimensional scanning transmission electron microscopy (4D-STEM) data. We apply the approach to a lead iridate, PbIrO, and yttrium-stabilized zirconia, YZrO, heterostructure from data acquired with the specimen in a single plan-view orientation, with the epitaxial layers stacked along the beam direction. We demonstrate that Pb–Ir atomic columns are visible in the uppermost layers of the reconstructed volume. We compare this approach to the alternative techniques of depth sectioning using differential phase contrast scanning transmission electron microscopy (DPC-STEM) and multislice ptychographic reconstruction.
A diagnostic to measure time-resolved atom column density and Doppler temperature in atomic vapors produced by laser ablation
We report on the development of a diagnostic to measure the time-resolved column density and Doppler temperature of atomic vapors produced by laser ablation. The diagnostic is based on the strong frequency dependence of the atomic susceptibility near an electronic transition in the interrogated atomic species. Interference on the face of a fast photodetector between the several frequency components present in a sinusoidally phase-modulated probe beam will produce a time signature uniquely determined by the column density of atoms in the probed atomic state and the Doppler temperature of the atomic vapor. With the extensive, high precision atomic spectroscopy data available in the literature, it is possible to model the vapor and extract the desired parameters through comparison of the model result with the experimental data.