Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKSCATTERING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Methods for Conducting Electron Backscattered Diffraction (EBSD) on Polycrystalline Organic Molecular Thin Films

Electron backscattered diffraction (EBSD) is a technique regularly used to obtain crystallographic information from inorganic samples. When EBSD is acquired simultaneously with emitting diodes data, a sample can be thoroughly characterized both structurally and compositionally. For organic materials, coherent Kikuchi patterns do form when the electron beam interacts with crystalline material. However, such patterns tend to be weak due to the low average atomic number of organic materials. This is compounded by the fact that the patterns fade quickly and disappear completely once a critical electron dose is exceeded, inhibiting successful collection of EBSD maps from them. In this paper, a new approach is presented that allows successful collection of EBSD maps from organic materials, here the extreme example of a hydrocarbon organic molecular thin film, and opens new avenues of characterization for crystalline organic materials.

42 ENGINEERING↗

X-ray back-diffraction: can we further increase the energy resolution by tuning the energy slightly below that of exact backscattering?

X-ray beams at energies tuned slightly below that of exact backscattering (extreme conditions, where X-ray back-diffraction is almost extinguished - called residual XBD) are better focused if the experiment is carried out at lower energies in order to avoid multiple-beam diffraction effects. Following previous work by the authors [Honnicke, Conley, Cusatis, Kakuno, Zhou, Bouet, Marques & Vicentin (2014). J. Appl. Cryst.47, 1658-1665], herein efforts are directed towards characterizing the residual XBD beam of an ultra-thin Si 220 crystal (UTSiXTAL) at similar to 3.2 keV. To achieve the residual XBD condition the UTSiXTAL was cooled from 310 to 273 K. The results indicate that under this extreme condition the energy resolution can be further improved. Issues with the energy resolution measurements due to incoming beam divergence and the ultra-thin crystal flatness are discussed.

low-energy X-ray back-diffraction↗

TU-D-209-02: A Backscatter Point Spread Function for Entrance Skin Dose Determination

Purpose: To determine the distribution of backscattered radiation to the skin resulting from a non-uniform distribution of primary radiation through convolution with a backscatter point spread function (PSF). Methods: A backscatter PSF is determined using Monte Carlo simulation of a 1 mm primary beam incident on a 30 × 30 cm × 20 cm thick PMMA phantom using EGSnrc software. A primary profile is similarly obtained without the phantom and the difference from the total provides the backscatter profile. This scatter PSF characterizes the backscatter spread for a “point” primary interaction and can be convolved with the entrance primary dose distribution to obtain the total entrance skin dose. The backscatter PSF was integrated into the skin dose tracking system (DTS), a graphical utility for displaying the color-coded skin dose distribution on a 3D graphic of the patient during interventional fluoroscopic procedures. The backscatter convolution method was validated for the non-uniform beam resulting from the use of an ROI attenuator. The ROI attenuator is a copper sheet with about 20% primary transmission (0.7 mm thick) containing a circular aperture; this attenuator is placed in the beam to reduce dose in the periphery while maintaining full dose in the region of interest. The DTS calculated primary plus backscatter distribution is compared to that measured with GafChromic film and that calculated using EGSnrc Monte-Carlo software. Results: The PSF convolution method used in the DTS software was able to account for the spread of backscatter from the ROI region to the region under the attenuator. The skin dose distribution determined using DTS with the ROI attenuator was in good agreement with the distributions measured with Gafchromic film and determined by Monte Carlo simulation Conclusion: The PSF convolution technique provides an accurate alternative for entrance skin dose determination with non-uniform primary x-ray beams. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

Improving OFDR Distributed Fiber Sensing by Fibers With Enhanced Rayleigh Backscattering and Image Processing

This article investigates using optical fibers with enhanced backscattering profiles to improve distributed fiber sensor performance and reduce instrumentation costs. Using a femtosecond (fs) laser direct writing technique, the Rayleigh backscattering profile of a standard telecom fiber was enhanced by more than 40 dB to improve the signal-to-noise ratio (SNR) for optical frequency domain reflectometry (OFDR). The enhanced backscattering signals enable effectively distributed strain measurements using a low-cost tunable laser (TL). Median filtering is applied to denoise cross correlation results to further improve measurement outcomes. Results presented in this article show that a TL with a 1-nm tuning range, which is far less than the tuning range used in commercial OFDR interrogators, can perform effectively distributed strain measurements using sensing fibers with enhanced backscattering profiles. The sensing fiber with over 40-dB backscattering enhancement achieved 4.8-cm spatial resolution in strain measurements with a root mean square accuracy of less than 2.70 με when 10–50 με were exerted to the sensing fiber. In conclusion, results presented in this article reveal both the potential and limitations of sensing fibers with enhanced backscattering for OFDR-based distributed fiber sensors.

42 ENGINEERING↗

SU-C-BRC-05: Monte Carlo Calculations to Establish a Simple Relation of Backscatter Dose Enhancement Around High-Z Dental Alloy to Its Atomic Number

Purpose: To establish a simple relation of backscatter dose enhancement around a high-Z dental alloy in head and neck radiation therapy to its average atomic number based on Monte Carlo calculations. Methods: The PHITS Monte Carlo code was used to calculate dose enhancement, which is quantified by the backscatter dose factor (BSDF). The accuracy of the beam modeling with PHITS was verified by comparing with basic measured data namely PDDs and dose profiles. In the simulation, a high-Z alloy of 1 cm cube was embedded into a tough water phantom irradiated by a 6-MV (nominal) X-ray beam of 10 cm × 10 cm field size of Novalis TX (Brainlab). The ten different materials of high-Z alloys (Al, Ti, Cu, Ag, Au-Pd-Ag, I, Ba, W, Au, Pb) were considered. The accuracy of calculated BSDF was verified by comparing with measured data by Gafchromic EBT3 films placed at from 0 to 10 mm away from a high-Z alloy (Au-Pd-Ag). We derived an approximate equation to determine the relation of BSDF and range of backscatter to average atomic number of high-Z alloy. Results: The calculated BSDF showed excellent agreement with measured one by Gafchromic EBT3 films at from 0 to 10 mm away from the high-Z alloy. We found the simple linear relation of BSDF and range of backscatter to average atomic number of dental alloys. The latter relation was proven by the fact that energy spectrum of backscatter electrons strongly depend on average atomic number. Conclusion: We found a simple relation of backscatter dose enhancement around high-Z alloys to its average atomic number based on Monte Carlo calculations. This work provides a simple and useful method to estimate backscatter dose enhancement from dental alloys and corresponding optimal thickness of dental spacer to prevent mucositis effectively.

60 APPLIED LIFE SCIENCES↗

Imaging and Segmenting Grains and Subgrains Using Backscattered Electron Techniques

We present two new methods of processing data from backscattered electron signals in a scanning electron microscope to image grains and subgrains. The first combines data from multiple backscattered electron images acquired at different specimen geometries to (1) better reveal grain boundaries in recrystallized microstructures and (2) distinguish between recrystallized and unrecrystallized regions in partially recrystallized microstructures. The second utilizes spherical harmonic transform indexing of electron backscatter diffraction patterns to produce high angular resolution orientation data that enable the characterization of subgrains. Subgrains are produced during high-temperature plastic deformation and have boundary misorientation angles ranging from a few degrees down to a few hundredths of a degree. Here, we also present an algorithm to automatically segment grains from combined backscattered electron image data or grains and subgrains from high angular resolution electron backscatter diffraction data. Together, these new techniques enable rapid measurements of individual grains and subgrains from large populations.

36 MATERIALS SCIENCE↗

Power flow in magnetically insulated transmission lines with ion backscatter effects

Ion backscattering off of surfaces in magnetically insulated transmission lines (MITLs) is often ignored in kinetic simulations of MITL power flow. Backscattering reduces ion current losses and the surface impact heating, which dictates the rate at which surface-adsorbed contaminants are liberated into the anode–cathode gap. Backscatter probabilities are difficult to implement in a kinetic code because there are limited data for incident ion energies less than a few keV. This paper presents an analytic model based on the Rutherford scattering formula that reproduces the measured backscatter probabilities at high incident energies and transitions to the highly reflective behavior expected at low incident energies. The backscatter model is implemented in power flow simulations, which are validated with current loss experiments conducted on the 0.4 TW Mykonos accelerator at Sandia National Laboratories. This simulation setup is then used in a high-current Z-machine shot. In conclusion, backscatter effects are found to be unimportant in the low-current Mykonos regime but significantly reduce current losses at the Z-machine scale.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Parametric Study of X-ray Energy Modulation for Depth Sensitive Backscatter Imaging

The technique of X-ray backscatter imaging has been studied for its applications in both medical imaging and nondestructive testing. The geometry and dimensionality of the detector system and photon source affect acquisition time, resolution, and signal to noise ratio (SNR) but the end result is still, at most, a 2D image. This is similar to transmission radiography with the difference being that the backscatter image has the benefit of requiring only single sided access to the object. Despite these physical limitations to the dimensions of a backscatter image, Towe and Jacobs showed that it is possible to obtain depth sensitive information (the third dimension in this case) by acquiring multiple images, each at a different X-ray tube voltage. By changing the average energy of the X-ray source, the penetration depth and therefore the signal which is generated from a backscatter design changes depending on the materials present in the object of interest. In order to further investigate the capabilities of depth sensitive X-ray backscatter imaging, a parametric study has been conducted on X-ray energy and its associated backscatter signal depth for materials relevant to medical imaging and non-destructive testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic coherent backscattering mirror

The phase of multiply scattered light has recently attracted considerable interest. Coherent backscattering is a striking phenomenon of multiple scattered light in which the coherence of light survives multiple scattering in a random medium and is observable in the direction space as an enhancement of the intensity of backscattered light within a cone around the retroreflection direction. Reciprocity also leads to enhancement of backscattering light in the spatial space. The random medium behaves as a reciprocity mirror which robustly converts a diverging incident beam into a converging backscattering one focusing at a conjugate spot in space. Here we first analyze theoretically this coherent backscattering mirror (CBM) phenomenon and then demonstrate the capability of CBM compensating and correcting both static and dynamic phase distortions occurring along the optical path. CBM may offer novel approaches for high speed dynamic phase corrections in optical systems and find applications in sensing and navigation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Backscatter dose effects for high atomic number materials being irradiated in the presence of a magnetic field: A Monte Carlo study for the MRI linac

Purpose: To quantify and explain the backscatter dose effects for clinically relevant high atomic number materials being irradiated in the presence of a 1.5 T transverse magnetic field. Methods: Interface effects were investigated using Monte Carlo simulation techniques. We used GPUMCD (v5.1) and GEANT4 (v10.1) for this purpose. GPUMCD is a commercial software written for the Elekta AB, MRI linac. Dose was scored using GPUMCD in cubic voxels of side 1 and 0.5 mm, in two different virtual phantoms of dimensions 20 × 20 × 20 cm and 5 × 5 × 13.3 cm, respectively. A photon beam was generated from a point 143.5 cm away from the isocenter with energy distribution sampled from a histogram representing the true Elekta, MRI linac photon spectrum. A slab of variable thickness and position containing either bone, aluminum, titanium, stainless steel, or one of the two different dental filling materials was inserted as an inhomogeneity in the 20 × 20 × 20 cm phantom. The 5 × 5 × 13.3 cm phantom was used as a clinical test case in order to explain the dose perturbation effects for a head and neck cancer patient. The back scatter dose factor (BSDF) was defined as the ratio of the doses at a given depth with and without the presence of the inhomogeneity. Backscattered electron fluence was calculated at the inhomogeneity interface using GEANT4. A 1.5 T magnetic field was applied perpendicular to the direction of the beam in both phantoms, identical to the geometry in the Elekta MRI linac. Results: With the application of a 1.5 T magnetic field, all the BSDF’s were reduced by 12%–47%, compared to the no magnetic field case. The corresponding backscattered electron fluence at the interface was also reduced by 45%–64%. The reduction in the BSDF at the interface, due to the application of the magnetic field, is manifested in a different manner for each material. In the case of bone, the dose drops at the interface contrary to the expected increase when no magnetic field is applied. In the case of aluminum, the dose at the interface is the same with and without the presence of the aluminum. For all of the other materials the dose increases at the interface. Conclusions: The reduction in dose at the interface, in the presence of the magnetic field, is directly related to the reduction in backscattered electron fluence. This reduction occurs due to two different reasons. First, the electron spectrum hitting the interface is changed when the magnetic field is turned on, which results in changes in the electron scattering probability. Second, some electrons that have curved trajectories due to the presence of the magnetic field are absorbed by the higher density side of the interface and no longer contribute to the backscattered electron fluence.

60 APPLIED LIFE SCIENCES↗

Laser transport and backscatter in low-density SiO 2 and Ta2O 5 foams

Experiments using a single 527 nm wavelength beam interacting with sub- and supercritical density SiO 2 and Ta 2 O 5 foams examined laser propagation and backscatter from laser–plasma instabilities such as Stimulated Brillouin Scattering (SBS). Two densities of each material were examined, and multiple diagnostics were used to characterize the propagation and backscatter. For 5 mg/cc SiO 2 (n e /n c = 0.375), the laser propagation distance was well approximated by treating the foam as a gas. However, for the 2 mg/cc SiO 2 foam (n e /n c = 0.15), the same model over-predicts the propagation distance by ~40%. Furthermore, existing analytical theories on propagation through subcritical foams were able to account for this difference. The laser heat wave propagated ~1/2 as far in Ta 2 O 5 than SiO 2 foams with similar electron density. We showed that this difference is due to the increased radiation losses in the higher Z foam. The fraction of backscattered light scales linearly with incident laser intensity for the range of intensities examined. Ta 2 O 5 foams had significantly lower levels of backscatter (1–3%) than the SiO 2 (4–8%), which is consistent with estimates of large Landau damping due to the presence of the oxygen atoms. The measured fraction of SBS backscattered laser energy for a 2 mg/cc SiO 2 foam shot was ~4 times lower than predicted by simulations assuming a gas-like foam. We found that we needed to assume increased ion heating such that T i /T e ~1.2–1.5 in the plasma to agree with the measured SBS reflectivity. Analytical models of laser-heated foams predict preferential heating of the ions as has been observed in previous experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The aCORN backscatter-suppressed beta spectrometer

Backscatter of electrons from a beta detector, with incomplete energy deposition, can lead to undesirable effects in many types of experiments. We present and discuss the design and operation of a backscatter-suppressed beta spectrometer that was developed as part of a program to measure the electron–antineutrino correlation coefficient in neutron beta decay (aCORN). An array of backscatter veto detectors surrounds a plastic scintillator beta energy detector. The spectrometer contains an axial magnetic field gradient, so electrons are efficiently admitted but have a low probability for escaping back through the entrance after backscattering. Lastly, the design, construction, calibration, and performance of the spectrometer are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling and Characterizing the electron backscatter in a cylindrical anode-based distributed X-ray source

Upcoming advancements in computed tomography architectures warrants the investigation of new X-ray source designs and the impacts that electron backscatter can have on these designs. One such design being investigated is a distributed, cylindrical anode-based X-ray source. For such a distributed X-ray source, we developed a modeling pipeline for simulating electron optics and transport to characterize the quality of the primary X-ray beam and the electron backscatter behavior. We report our results on the energy distributions of the bremsstrahlung spectra; electron backscatter ratio; and spatial, temporal, and energy distributions of backscattered electrons that return to the anode.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

The Backscattering Phase Function for a Sphere with a Two-Scale Relief of Rough Surface

The backscattering of light from spherical surfaces characterized by one and two-scale roughness reliefs has been investigated. The analysis is performed using the three-dimensional Monte-Carlo program POKS-RG (geometrical-optics approximation), which makes it possible to take into account the roughness of objects under study by introducing local geometries of different levels. The geometric module of the program is aimed at describing objects by equations of second-order surfaces. One-scale roughness is set as an ensemble of geometric figures (convex or concave halves of ellipsoids or cones). The two-scale roughness is modeled by convex halves of ellipsoids, with surface containing ellipsoidal pores. It is shown that a spherical surface with one-scale convex inhomogeneities has a flatter backscattering phase function than a surface with concave inhomogeneities (pores). For a sphere with two-scale roughness, the dependence of the backscattering intensity is found to be determined mostly by the lower-level inhomogeneities. The influence of roughness on the dependence of the backscattering from different spatial regions of spherical surface is analyzed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rays for Roots - Integrating Backscatter X-Ray Phenotyping, Modeling and Genetics to Increase Carbon Sequestration and Switchgrass Resource Use (Final Report)

To increase carbon (C) deposition in the soil and enhance crop resource use efficiency, characterizing root form and function is essential. Several root and soil traits have been linked to increased root-to-soil C transfer. Technology that could provide high-resolution characterization of many of these traits in field conditions would revolutionize our ability to study and understand how to increase C sequestration. In this effort, we developed an initial early prototype backscatter X-ray system for non-destructive imaging of root traits. We collected initial backscatter X-ray data in field and lab settings and carried out early analysis of these data. Along with this prototype, we also developed a suite of root phenotyping approaches including advanced minirhizotron image analysis, soil core imaging, and mesocosm imaging. Minirhizotron (MR) tubes are clear tubes inserted into the soil in the field and used to image roots and the surrounding soil. Our team has developed deep learning-based methods that can segment roots from soil that can learn from imprecise image-level labels. The ability to learn or fine-tune our deep learning algorithms from image-level labels allows easier and faster application of these approaches to new locations and new plant species. We have successfully implemented and applied our MR analysis approaches to thousands of switchgrass MR images collected across geographical regions. An advantage of MR imaging is the ability to collect root and soil images over time. Our soil core analysis included collecting hundreds of soil core samples from harvested switchgrass fields and imaging these cores with both X-ray CT and backscatter X-ray imaging. Initial segmentation approaches for the X-ray CT images of these cores have been developed and applied. An advantage of soil core analysis is that it preserves the three-dimensional structures of the roots and soil in the core collected. Our group also developed photogrammetry-based mesocosm root imaging and phenotyping approaches. In this approach, a plant was grown in a large mesocosm with a three-dimensional grid of thin supporting lines inserted throughout the mesocosm. After the plant (and, correspondingly, the root architecture is grown and established) the soil media was removed and the supporting lines approximately preserved the three-dimensional root architecture. Then, we applied photogrammetry techniques to create a three-dimensional digital representation of the root architecture for which we developed analysis algorithms including skeletonization. We carried out our phenotyping development with powerful switchgrass resources and physiological and agroecosystem modeling to deliver novel technology. This project contributes to multiple ARPA-E missions including reduction of foreign imports of energy, reduction of energy-related emissions including greenhouse gases, and ensuring that the United States maintains a technological lead in developing and deploying advanced energy technology. Furthermore, the developed tools could transform public and private plant breeding and could be broadly applicable to other crops and, potentially, other application areas. Our team of engineers, plant and soil scientists, and modelers i) developed an early prototype backscatter X-ray platform that can operate in field conditions; ii) developed a suite of root phenotyping and characterization approaches as described above; iii) developed and carried out plant biology and physiology roots studies and; iv) developed and implemented mechanistic physiological modeling.

42 ENGINEERING↗

Information depth in backscattered electron microscopy of nanoparticles within a solid matrix

Highlights: • Backscattered electron microscopy was used for reliable determination of nanoparticle density and sizes within Al alloys • Backscattered electron information depth was determined as a function of nanoparticle size from Monte Carlo simulations • Unlike transmission electron microscopy, the method is non-destructive and allows analyzing large sample areas • Good agreement with transmission electron microscopy data shows that our method is suitable for nanocomposite materials - Abstract: Measuring the dimensions and number density of nanoparticles dispersed in a solid matrix is usually accomplished via transmission electron microscopy (TEM) which suffers from high cost, low throughput, and small analytical volume. In comparison, scanning backscattered electron microscopy is inexpensive, requires little sample preparation, and allows for the analysis of large sample areas. However, the information depth is usually not known precisely and depends on several factors such as the composition of the nanoparticles and the matrix as well as the size of the nanoparticles, hindering the reconstruction of the actual size distribution and three-dimensional number density. Here we present a method to estimate the information depth for spherical nanoparticles of different sizes in order to accurately determine size distribution and number density. The approach is based on Monte Carlo simulation of electron trajectories in the material and analysis of the obtained backscattered electron signal-to-noise-ratio. Our experimental results are compared to those obtained via TEM and good agreement is demonstrated; this shows that TEM can be replaced by scanning electron microscopy for studying nanocomposites in many cases.

77 NANOSCIENCE AND NANOTECHNOLOGY↗