Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AuC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Probing the electronic structure and Au—C chemical bonding in AuC{sub n}{sup −} and AuC{sub n}H{sup −} (n = 2, 4, and 6) using high-resolution photoelectron spectroscopy

We report a joint photoelectron spectroscopy and theoretical study on AuC{sub 4}{sup −}, AuC{sub 6}{sup −}, and AuC{sub n}H{sup −} (n = 2, 4, and 6) using high-resolution photoelectron imaging and ab initio calculations. The ground state of AuC{sub 2}H{sup −}, AuC{sub 4}H{sup −}, and AuC{sub 6}H{sup −} is found to be linear, while that of AuC{sub 4}{sup −} and AuC{sub 6}{sup −} is bent. All the species are found to be linear in their neutral ground states. The electron affinities (EAs) are measured to be 3.366(1) and 3.593(1) eV for AuC{sub 4} and AuC{sub 6}, respectively. Both bending and stretching frequencies are resolved in the spectra of AuC{sub 4}{sup −} and AuC{sub 6}{sup −}. High-resolution data of AuC{sub n}H{sup −} reveal major vibrational progressions in the Au—C stretching and bending modes. AuC{sub 2}H{sup −} has a ground state stretching frequency of 445(10) cm{sup −1} and a bending frequency of 260(10) cm{sup −1}; AuC{sub 4}H{sup −} has a ground state stretching frequency of 340(10) cm{sup −1}; AuC{sub 6}H{sup −} has a ground state stretching frequency of 260(10) cm{sup −1} and a bending frequency of 55(10) cm{sup −1}. The EAs are measured to be 1.475(1), 1.778(1), and 1.962(1) eV for AuC{sub 2}H, AuC{sub 4}H, and AuC{sub 6}H, respectively. The strength of the Au—C bond decreases as the number of carbon atoms increases. The current study provides a wealth of electronic structure information about AuC{sub 4}{sup −}, AuC{sub 6}{sup −}, and AuC{sub n}H{sup −} (n = 2, 4, and 6) and their corresponding neutrals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single reader between-cases AUC estimator with nested data

The area under the receiver operating characteristic curve (AUC) is widely used in evaluating diagnostic performance for many clinical tasks. It is still challenging to evaluate the reading performance of distinguishing between positive and negative regions of interest (ROIs) in the nested-data problem, where multiple ROIs are nested within the cases. To address this issue, we identify two kinds of AUC estimators, within-cases AUC and between-cases AUC. We focus on the between-cases AUC estimator, since our main research interest is in patient-level diagnostic performance rather than location-level performance (the ability to separate ROIs with and without disease within each patient). Another reason is that as the case number increases, the number of between-cases paired ROIs is much larger than the number of within-cases ROIs. We provide estimators for the variance of the between-cases AUC and for the covariance when there are two readers. We derive and prove the above estimators’ theoretical values based on a simulation model and characterize their behavior using Monte Carlo simulation results. We also provide a real-data example. Moreover, we connect the distribution-based simulation model with the simulation model based on the linear mixed-effect model, which helps better understand the sources of variation in the simulated dataset.

Health Care Sciences & Services↗

Probing the electronic structure and Au–C chemical bonding in AuC{sub 2}{sup −} and AuC{sub 2} using high-resolution photoelectron spectroscopy

We report photoelectron spectroscopy (PES) and high-resolution PE imaging of AuC{sub 2}{sup −} at a wide range of photon energies. The ground state of AuC{sub 2}{sup −} is found to be linear (C{sub ∞v}, {sup 1}Σ{sup +}) with a …8π{sup 4}4δ{sup 4}17σ{sup 2}9π{sup 4}18σ{sup 2} valence configuration. Detachments from all the five valence orbitals of the ground state of AuC{sub 2}{sup −} are observed at 193 nm. High-resolution PE images are obtained in the energy range from 830 to 330 nm, revealing complicated vibronic structures from electron detachment of the 18σ, 9π, and 17σ orbitals. Detachment from the 18σ orbital results in the {sup 2}Σ{sup +} ground state of neutral AuC{sub 2}, which, however, is bent due to strong vibronic coupling with the nearby {sup 2}Π state from detachment of a 9π electron. The {sup 2}Σ{sup +}–{sup 2}Π vibronic and spin-orbit coupling results in complicated vibronic structures for the {sup 2}Σ{sup +} and {sup 2}Π{sub 3/2} states with extensive bending excitations. The electron affinity of AuC{sub 2} is measured accurately to be 3.2192(7) eV with a ground state bending frequency of 195(6) cm{sup −1}. The first excited state ({sup 2}A′) of AuC{sub 2}, corresponding to the {sup 2}Π{sub 3/2} state at the linear geometry, is only 0.0021 eV above the ground state ({sup 2}A′) and has a bending frequency of 207(6) cm{sup −1}. The {sup 2}Π{sub 1/2} state, 0.2291 eV above the ground state, is linear with little geometry change relative to the anion ground state. The detachment of the 17σ orbital also results in complicated vibronic structures, suggesting again a bent state due to possible vibronic coupling with the lower {sup 2}Π state. The spectrum at 193 nm shows the presence of a minor species with less than 2% intensity relative to the ground state of AuC{sub 2}{sup −}. High-resolution data of the minor species reveal several vibrational progressions in the Au–C stretching mode, which are assigned to be from the metastable {sup 3}Π{sub 2,1,0} spin-orbit excited states of AuC{sub 2}{sup −} to the {sup 2}Π{sub 3/2,1/2} spin-orbit states of neutral AuC{sub 2}. The spin-orbit splittings of the {sup 3}Π and {sup 2}Π states are accurately measured at the linear geometry. The current study provides a wealth of electronic structure information about AuC{sub 2}{sup −} and AuC{sub 2}, which are ideal systems to investigate the strong Σ–Π and spin-orbit vibronic couplings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Theoretical predictive screening of noble-metal-containing M 3 AuC 2 (M = Ti, V, and Cr) MAX phases

Using first-principles density functional theory (DFT), the ground state physical properties of the newly synthesized noble-metal-containing Ti 3 AuC 2 MAX phase have been investigated. The effect of transition-element Ti replacement (V and Cr) on physical properties, including structural, elastic, electronic, thermal, and optical are presented. The optimized lattice parameters of Ti 3 AuC 2 MAX phase are in good agreement with the experimental values and decrease when we replace Ti with V and then Cr. The magnetic properties of M 3 AuC 2 are predicted by using generalized gradient approximation (GGA) incorporating onsite electron correlation parameter (Hubbard U parameter) within DFT. Out of three studied MAX phases, V 3 AuC 2 and Cr 3 AuC 2 phases exhibit magnetism. The thermodynamical stability of M 3 AuC 2 (M = Ti, V, and Cr) phases is discussed by the formation enthalpy with respect to their most competing phases. The electronic structure reveals that these phases have metallic nature and are electrically anisotropic. The M-element replacement has an effect on the bonding properties of M 3 AuC 2 . The bonding between M-C is in the order of Cr 3 AuC 2 > V 3 AuC 2 > Ti 3 AuC 2 according to their peak positions and heights of density of states in the occupied site, which is also confirmed from the charge density distribution. The elastic properties indicate that M 3 AuC 2 phases are ductile, machinable, less stiff, and better resistant to thermal shock and are elastically anisotropic. To understand the properties of M 3 AuC 2 for the extreme environment, we employed a quasi-harmonic Debye model at the pressure and temperature range of 0–50 GPa and 0–1600 K, respectively. Additionally, we evaluated thermal conductivity and melting temperature to further understand the potential of these MAX phases in coating applications at elevated temperature. In relation to optical properties, these MAX phases have a reasonable absorption coefficient in the visible as well as in the ultra-violet regions. The reflectivity of M 3 AuC 2 phases is polarization dependent and of 45 % against the visible region, which reveals its potential as coating material to minimize solar heating.

312 MAX phases↗

Materials Data on AuC by Materials Project

AuC is Tungsten Carbide structured and crystallizes in the hexagonal P-6m2 space group. The structure is three-dimensional. Au2+ is bonded to six equivalent C2- atoms to form a mixture of distorted edge, face, and corner-sharing AuC6 pentagonal pyramids. All Au–C bond lengths are 2.38 Å. C2- is bonded to six equivalent Au2+ atoms to form a mixture of distorted edge, face, and corner-sharing CAu6 pentagonal pyramids.

36 MATERIALS SCIENCE↗

Materials Data on AuC by Materials Project

AuC is Wurtzite structured and crystallizes in the hexagonal P6_3mc space group. The structure is three-dimensional. Au2+ is bonded to four equivalent C2- atoms to form corner-sharing AuC4 tetrahedra. All Au–C bond lengths are 2.14 Å. C2- is bonded to four equivalent Au2+ atoms to form corner-sharing CAu4 tetrahedra.

36 MATERIALS SCIENCE↗

First spectroscopic observation of gold(I) butadiynylide: Photodetachment velocity map imaging of the AuC{sub 4}H anion

The velocity map imaging technique was used in the investigation of gold(I) butadiynylide, AuC{sub 4}H{sup −}, with images recorded at two excitation wavelengths. The resultant photodetachment spectra show a well defined vibrational progression in the neutral with an energy spacing of 343 ± 3 cm{sup −1}. The adiabatic electron affinity was determined to be 1.775 ± 0.005 eV and assigned to the X{sup 1}Σ{sup +}←X{sup 2}Σ{sup +} transition between the anionic and neutral ground states. Franck-Condon simulations performed on density functional theory optimized geometries assisted the assignment of linear geometries to the neutral and anion and the observed vibrational progression to that of the Au–C{sub 4}H stretch.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MO-DE-207B-01: JACK FOWLER JUNIOR INVESTIGATOR COMPETITION WINNER: Between Somatic Mutations and PET-Based Radiomic Features in Non-Small Cell Lung Cancer

Purpose: Although PET-based radiomic features have been proposed to quantify tumor heterogeneity and shown promise in outcome prediction, little is known about their relationship with tumor genetics. This study assessed the association of [{sup 18}F]fluorodeoxyglucose (FDG)-PET-based radiomic features with non-small cell lung cancer (NSCLC) mutations. Methods: 348 NSCLC patients underwent FDG-PET/CT scans before treatment and were tested for genetic mutations. 13% (44/348) and 28% (96/348) patients were found to harbor EGFR (EGFR+) and KRAS (KRAS+) mutations, respectively. We evaluated nineteen PET-based radiomic features quantifying phenotypic traits, and compared them with conventional PET features (metabolic tumor volume (MTV) and maximum-SUV). The association between the feature values and mutation status was evaluated using the Wilcoxcon-rank-sum-test. The ability of each measure to predict mutations was assessed by the area under the receiver operating curve (AUC). Noether’s test was used to determine if the AUCs were significantly from random (AUC=0.50). All p-values were corrected for multiple testing by controlling the false discovery rate (FDR{sub Wilcoxon} and FDR{sub Noether}) of 10%. Results: Eight radiomic features, MTV, and maximum-SUV, were significantly associated with the EGFR mutation (FDR{sub Wilcoxon}=0.01–0.10). However, KRAS+ demonstrated no significantly distinctive imaging features compared to KRAS− (FDR{sub Wilcoxon}≥0.92). EGFR+ and EGFR− were significantly discriminated by conventional PET features (AUC=0.61, FDR{sub Noether}=0.04 for MTV and AUC=0.64, FDR{sub Noether}=0.01 for maximum-SUV). Eight radiomic features were significantly predictive for EGFR+ compared to EGFR− (AUC=0.59–0.67, FDR{sub Noether}=0.0032–0.09). Normalized-inverse-difference-moment outperformed all features in predicting EGFR mutation (AUC=0.67, FDR{sub Noether}=0.0032). Moreover, only the radiomic feature normalized-inverse-difference-moment could significantly predict KRAS+ from EGFR+ (AUC=0.65, FDR{sub Noether}=0.05). All measures failed to predict KRAS+ from KRAS− (AUC=0.50–0.54, FDR{sub Noether}≥0.92). Conclusion: PET imaging features were strongly associated with EGFR mutations in NSCLC. Radiomic features have great potential in predicting EGFR mutations. Our study may help develop a non-invasive imaging biomarker for EGFR mutation. R.M. has consulting interests with Amgen.

60 APPLIED LIFE SCIENCES↗

In vivo doses of butadiene epoxides as estimated from in vitro enzyme kinetics by using cob(I)alamin and measured hemoglobin adducts: An inter-species extrapolation approach

1,3-Butadiene (BD) is a rodent and human carcinogen. In the cancer tests, mice have been much more susceptible than rats with regard to BD-induced carcinogenicity. The species-differences are dependent on metabolic formation/disappearance of the genotoxic BD epoxy-metabolites that lead to variations in the respective in vivo doses, i.e. “area under the concentration-time curve” (AUC). Differences in AUC of the most gentoxic BD epoxy-metabolite, diepoxybutane (DEB), are considered important with regard to cancer susceptibility. The present work describes: the application of cob(I)alamin for accurate measurements of in vitro enzyme kinetic parameters associated with BD epoxy-metabolites in human, mouse and rat; the use of published data on hemoglobin (Hb) adduct levels of BD epoxides from BD exposure studies on the three species to calculate the corresponding AUCs in blood; and a parallelogram approach for extrapolation of AUC of DEB based on the in vitro metabolism studies and adduct data from in vivo measurements. The predicted value of AUC of DEB for humans from the parallelogram approach was 0.078 nM · h for 1 ppm · h of BD exposure compared to 0.023 nM · h/ppm · h as calculated from Hb adduct levels observed in occupational exposure. The corresponding values in nM · h/ppm · h were for mice 41 vs. 38 and for rats 1.26 vs. 1.37 from the parallelogram approach vs. experimental exposures, respectively, showing a good agreement. This quantitative inter-species extrapolation approach will be further explored for the clarification of metabolic rates/pharmacokinetics and the AUC of other genotoxic electrophilic compounds/metabolites, and has a potential to reduce and refine animal experiments. - Highlights: • In vitro metabolism to in vivo dose extrapolation of butadiene metabolites was proposed. • A parallelogram approach was introduced to estimate dose (AUC) in humans and rodents. • AUC of diepoxybutane predicted in humans was 0.078 nM h/ppm h butadiene exposure. • The presented approach has a potential to reduce, refine and replace animal experiments.

60 APPLIED LIFE SCIENCES↗

Residual analysis of the water resonance signal in breast lesions imaged with high spectral and spatial resolution (HiSS) MRI: A pilot study

Purpose: High spectral and spatial resolution magnetic resonance imaging (HiSS MRI) yields information on the local environment of suspicious lesions. Previous work has demonstrated the advantages of HiSS (complete fat-suppression, improved image contrast, no required contrast agent, etc.), leading to initial investigations of water resonance lineshape for the purpose of breast lesion classification. The purpose of this study is to investigate a quantitative imaging biomarker, which characterizes non-Lorentzian components of the water resonance in HiSS MRI datasets, for computer-aided diagnosis (CADx). Methods: The inhomogeneous broadening and non-Lorentzian or “off-peak” components seen in the water resonance of proton spectra of breast HiSS images are analyzed by subtracting a Lorentzian fit from the water peak spectra and evaluating the difference spectrum or “residual.” The maxima of these residuals (referred to hereafter as “off-peak components”) tend to be larger in magnitude in malignant lesions, indicating increased broadening in malignant lesions. The authors considered only those voxels with the highest magnitude off-peak components in each lesion, with the number of selected voxels dependent on lesion size. Our voxel-based method compared the magnitudes and frequencies of off-peak components of all voxels from all lesions in a database that included 15 malignant and 8 benign lesions (yielding ∼3900 voxels) based on the lesions’ biopsy-confirmed diagnosis. Lesion classification was accomplished by comparing the average off-peak component magnitudes and frequencies in malignant and benign lesions. The area under the ROC curve (AUC) was used as a figure of merit for both the voxel-based and lesion-based methods. Results: In the voxel-based task of distinguishing voxels from malignant and benign lesions, off-peak magnitude yielded an AUC of 0.88 (95% confidence interval [0.84, 0.91]). In the lesion-based task of distinguishing malignant and benign lesions, average off-peak magnitude yielded an AUC 0.83 (95% confidence interval [0.61, 0.98]). Conclusions: These promising AUC values suggest that analysis of the water-resonance in each HiSS image voxel using “residual analysis” could have high diagnostic utility and could be used to enhance current CADx methods and allow detection of breast cancer without the need to inject contrast agents.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and optimization of SPECT gated blood pool cluster analysis for the prediction of CRT outcome

Purpose: Phase analysis of single photon emission computed tomography (SPECT) radionuclide angiography (RNA) has been investigated for its potential to predict the outcome of cardiac resynchronization therapy (CRT). However, phase analysis may be limited in its potential at predicting CRT outcome as valuable information may be lost by assuming that time-activity curves (TAC) follow a simple sinusoidal shape. A new method, cluster analysis, is proposed which directly evaluates the TACs and may lead to a better understanding of dyssynchrony patterns and CRT outcome. Cluster analysis algorithms were developed and optimized to maximize their ability to predict CRT response. Methods: About 49 patients (N = 27 ischemic etiology) received a SPECT RNA scan as well as positron emission tomography (PET) perfusion and viability scans prior to undergoing CRT. A semiautomated algorithm sampled the left ventricle wall to produce 568 TACs from SPECT RNA data. The TACs were then subjected to two different cluster analysis techniques, K-means, and normal average, where several input metrics were also varied to determine the optimal settings for the prediction of CRT outcome. Each TAC was assigned to a cluster group based on the comparison criteria and global and segmental cluster size and scores were used as measures of dyssynchrony and used to predict response to CRT. A repeated random twofold cross-validation technique was used to train and validate the cluster algorithm. Receiver operating characteristic (ROC) analysis was used to calculate the area under the curve (AUC) and compare results to those obtained for SPECT RNA phase analysis and PET scar size analysis methods. Results: Using the normal average cluster analysis approach, the septal wall produced statistically significant results for predicting CRT results in the ischemic population (ROC AUC = 0.73;p < 0.05 vs. equal chance ROC AUC = 0.50) with an optimal operating point of 71% sensitivity and 60% specificity. Cluster analysis results were similar to SPECT RNA phase analysis (ROC AUC = 0.78, p = 0.73 vs cluster AUC; sensitivity/specificity = 59%/89%) and PET scar size analysis (ROC AUC = 0.73, p = 1.0 vs cluster AUC; sensitivity/specificity = 76%/67%). Conclusions: A SPECT RNA cluster analysis algorithm was developed for the prediction of CRT outcome. Cluster analysis results produced results equivalent to those obtained from Fourier and scar analysis.

60 APPLIED LIFE SCIENCES↗

TU-C-BRE-09: Performance Comparisons of Patient Specific IMRT QA Methodologies Using ROC Analysis

Purpose: To evaluate the ability of a selection of patient-specific QA methods to accurately classify IMRT plans as acceptable or unacceptable based on a multiple ion chamber (MIC) phantom. Methods: Twenty-four IMRT plans were selected (20 previously failed the institutional QA), and were measured on a MIC phantom to assess their dosimetric acceptability. These same plans were then measured using film (Kodak EDR2) and ion chamber (Wellhofer cc04), ArcCheck (Sun Nuclear), and MapCheck (Sun Nuclear) (delivered AP field-by-field, AP composite, and with original gantry angles). All gamma analyses were performed at 2%/2mm, 3%/3mm, and 5%/3mm. By using the MIC results as a gold standard, the sensitivity and specificity were calculated across a range of cut-off thresholds (% pixels passing for gamma analysis, and % dose difference for ion chamber), and were used to form ROC curves. Area under the curve (AUC) was used as a metric to quantify the performance of the various QA methods. Results: Grouping device’s AUC’s revealed two statistically significant different groups: ion chamber (AUC of 0.94), AP composite MapCheck (AUC of 0.85), ArcCheck (AUC of 0.84), and film (AUC of 0.82) were in the better performing group, while original gantry angles and AP field-by-field MapCheck (AUC of 0.65 and 0.66, respectively) matched less well with the gold standard results. Optimal cut-offs were also assessed using the ROC curves. We found that while often 90% of pixels passing is used as a criteria, the differing sensitivities of QA methods can lead to device and methodology-based optimal cutoff thresholds. Conclusion: While many methods exist to perform the same task of patient-specific IMRT QA, they utilize different strategies. This work has shown that there are inconsistencies in these methodologies in terms of their sensitivity and specificity to dosimetric acceptability. This work was supported by Public Health Service grants CA010953, CA081647, and CA21661 awarded by the National Cancer Institute, United States Department of Health and Human Services.

60 APPLIED LIFE SCIENCES↗

Enhanced Surgical Decision-Making Tools in Breast Cancer: Predicting 2-Year Postoperative Physical, Sexual, and Psychosocial Well-Being following Mastectomy and Breast Reconstruction (INSPiRED 004)

Background: We sought to predict clinically meaningful changes in physical, sexual, and psychosocial well-being for women undergoing cancer-related mastectomy and breast reconstruction 2 years after surgery using machine learning (ML) algorithms trained on clinical and patient-reported outcomes data. Patients and Methods: We used data from women undergoing mastectomy and reconstruction at 11 study sites in North America to develop three distinct ML models. We used data of ten sites to predict clinically meaningful improvement or worsening by comparing pre-surgical scores with 2 year follow-up data measured by validated Breast-Q domains. We employed ten-fold cross-validation to train and test the algorithms, and then externally validated them using the 11th site’s data. We considered area-under-the-receiver-operating-characteristics-curve (AUC) as the primary metric to evaluate performance. Results: Overall, between 1454 and 1538 patients completed 2 year follow-up with data for physical, sexual, and psychosocial well-being. In the hold-out validation set, our ML algorithms were able to predict clinically significant changes in physical well-being (chest and upper body) (worsened: AUC range 0.69–0.70; improved: AUC range 0.81–0.82), sexual well-being (worsened: AUC range 0.76–0.77; improved: AUC range 0.74–0.76), and psychosocial well-being (worsened: AUC range 0.64–0.66; improved: AUC range 0.66–0.66). Baseline patient-reported outcome (PRO) variables showed the largest influence on model predictions. Conclusions: Machine learning can predict long-term individual PROs of patients undergoing postmastectomy breast reconstruction with acceptable accuracy. This may better help patients and clinicians make informed decisions regarding expected long-term effect of treatment, facilitate patient-centered care, and ultimately improve postoperative health-related quality of life.

60 APPLIED LIFE SCIENCES↗

Tau Positron Emission Tomography for Predicting Dementia in Individuals With Mild Cognitive Impairment

An accurate prognosis is especially pertinent in mild cognitive impairment (MCI), when individuals experience considerable uncertainty about future progression. To evaluate the prognostic value of tau positron emission tomography (PET) to predict clinical progression from MCI to dementia. This was a multicenter cohort study with external validation and a mean (SD) follow-up of 2.0 (1.1) years. Data were collected from centers in South Korea, Sweden, the US, and Switzerland from June 2014 to January 2024. Participant data were retrospectively collected and inclusion criteria were a baseline clinical diagnosis of MCI; longitudinal clinical follow-up; a Mini-Mental State Examination (MMSE) score greater than 22; and available tau PET, amyloid-β (Aβ) PET, and magnetic resonance imaging (MRI) scan less than 1 year from diagnosis. A total of 448 eligible individuals with MCI were included (331 in the discovery cohort and 117 in the validation cohort). None of these participants were excluded over the course of the study. Exposures included Tau PET, Aβ PET, and MRI. Positive results on tau PET (temporal meta–region of interest), Aβ PET (global; expressed in the standardized metric Centiloids), and MRI (Alzheimer disease [AD] signature region) was assessed using quantitative thresholds and visual reads. Clinical progression from MCI to all-cause dementia (regardless of suspected etiology) or to AD dementia (AD as suspected etiology) served as the primary outcomes. The primary analyses were receiver operating characteristics. In the discovery cohort, the mean (SD) age was 70.9 (8.5) years, 191 (58%) were male, the mean (SD) MMSE score was 27.1 (1.9), and 110 individuals with MCI (33%) converted to dementia (71 to AD dementia). Only the model with tau PET predicted all-cause dementia (area under the receiver operating characteristic curve [AUC], 0.75; 95% CI, 0.70-0.80) better than a base model including age, sex, education, and MMSE score (AUC, 0.71; 95% CI, 0.65-0.77; P = .02), while the models assessing the other neuroimaging markers did not improve prediction. In the validation cohort, tau PET replicated in predicting all-cause dementia. Compared to the base model (AUC, 0.75; 95% CI, 0.69-0.82), prediction of AD dementia in the discovery cohort was significantly improved by including tau PET (AUC, 0.84; 95% CI, 0.79-0.89; P < .001), tau PET visual read (AUC, 0.83; 95% CI, 0.78-0.88; P = .001), and Aβ PET Centiloids (AUC, 0.83; 95% CI, 0.78-0.88; P = .03). In the validation cohort, only the tau PET and the tau PET visual reads replicated in predicting AD dementia. In this study, tau-PET showed the best performance as a stand-alone marker to predict progression to dementia among individuals with MCI. This suggests that, for prognostic purposes in MCI, a tau PET scan may be the best currently available neuroimaging marker.

59 BASIC BIOLOGICAL SCIENCES↗

Feasibility of using computed tomography texture analysis parameters as imaging biomarkers for predicting risk grade of gastrointestinal stromal tumors: comparison with visual inspection

Purpose: To evaluate the feasibility of using computed tomography texture analysis (CTTA) parameters for predicting malignant risk grade and mitosis index of gastrointestinal stromal tumors (GISTs), compared with visual inspection. Method and materials: CTTA was performed on portal phase CT images of 145 surgically confirmed GISTs (mean size: 42.9 ± 37.5 mm), using TexRAD software. Mean, standard deviation, entropy, mean of positive pixels (MPP), skewness, and kurtosis of CTTA parameters, on spatial scaling factor (SSF), 2–6 were compared by risk grade, mitosis rate, and the presence or absence of necrosis on visual inspection. CTTA parameters were correlated with risk grade. Diagnostic performance was evaluated with receiver operating characteristic curve analysis. Enhancement pattern, necrosis, heterogeneity, calcification, growth pattern, and mucosal ulceration were subjectively evaluated by two observers. Results: Three to four parameters at different scales were significantly different according to the risk grade, mitosis rate, and the presence or absence of necrosis (p < 0.041). MPP at fine or medium scale (r = − 0.547 to − 393) and kurtosis at coarse scale (r = 0.424–0.454) correlated significantly with risk grade (p < 0.001). HG-GIST was best differentiated from LG-GIST by MPP at SSF 2 (AUC, 0.782), and kurtosis at SSF 4 (AUC, 0.779) (all p < 0.001). CT features predictive of HG-GIST were density lower than or equal to that of the erector spinae muscles on enhanced images (OR 2.1; p = 0.037; AUC, 0.59), necrosis (OR, 6.1; p < 0.001; AUC, 0.70), heterogeneity (OR, 4.3; p < 0.001; AUC, 0.67), and mucosal ulceration (OR, 3.3; p = 0.002; AUC, 0.62). Conclusion: Using TexRAD, MPP and kurtosis are feasible in predicting risk grade and mitosis index of GISTs. CTTA demonstrated meaningful accuracy in preoperative risk stratification of GISTs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of ABCB1 polymorphisms on the pharmacokinetics and toxicity of lenalidomide in patients with multiple myeloma

Individual diversity in plasma concentrations of lenalidomide occurs despite dosage modifications based on creatinine clearance (CCr), which can lead to unexpected toxicity. We have previously identified a cutoff value of area under the concentration–time curve (AUC{sub 0–24}) for lenalidomide to avoid severe toxicity. Here, we investigated the association between ABCB1 polymorphisms and pharmacokinetics of lenalidomide in patients with multiple myeloma (MM) treated with lenalidomide and dexamethasone. Plasma concentrations of lenalidomide were analyzed using liquid chromatography–tandem mass spectrometry. Genotyping for ABCB1 1236C>T, 2677G>A/T, and 3435C>T polymorphisms was performed, and the effects of ABCB1 polymorphisms on AUC{sub 0–24} for lenalidomide were compared in 36 patients with MM who were administered lenalidomide according to the drug label based on CCr. Genotyping analysis showed that although there were no differences in AUC{sub 0–24} in 1236C>T and 2677G>A/T polymorphisms. AUC{sub 0–24} was significantly higher in patients with the T allele of 3435C>T (n = 15) than in those without (n = 21) (median 6324.6 ng h/mL vs. 2857.4 ng h/mL, p = 0.028). The AUC{sub 0–24} value exceeded the aforementioned cutoff value in 95% of the patients with the T allele of 3435C>T but in 60% with C/C genotype (p = 0.013). Multivariate logistic analysis confirmed the significance of T allele of ABCB1 3435C>T as a factor due to which the AUC{sub 0–24} cutoff value was exceeded (hazard ratio of 15.0, p = 0.019). We show that lenalidomide pharmacokinetics is influenced by the ABCB1 3435C>T polymorphism, which could be useful to individualize dosage design and reduce unexpected toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving perfusion defect detection with respiratory motion correction in cardiac SPECT at standard and reduced doses

Background: In cardiac SPECT perfusion imaging, respiratory motion can cause non-uniform blurring in the reconstructed myocardium. We investigate the potential benefit of respiratory correction with respiratory-binned acquisitions, both at standard dose and at reduced dose, for defect detection and for left ventricular (LV) wall resolution. Methods: We applied two reconstruction methods for respiratory motion correction: post-reconstruction motion correction (PMC) and motion-compensated reconstruction (MCR), and compared with reconstruction without motion correction (Non-MC). We quantified the presence of perfusion defects in reconstructed images by using the total perfusion deficit (TPD) scores and conducted receiver-operating-characteristic (ROC) studies using TPD. We quantified the LV spatial resolution by using the FWHM of its cross-sectional intensity profile. Results: The values in the area-under-the-ROC-curve (AUC) achieved by MCR, PMC, and Non-MC at standard dose were 0.835, 0.830, and 0.798, respectively. Similar AUC improvements were also obtained by MCR and PMC over Non-MC at 50%, 25%, and 12.5% of full dose. Improvements in LV resolution were also observed with motion correction. Conclusions: Respiratory-binned acquisitions can improve perfusion-defect detection accuracy over traditional reconstruction both at standard dose and at reduced dose. Motion correction may contribute to achieving further dose reduction while maintaining the diagnostic accuracy of traditional acquisitions. [French] French Abstract: Contexte: Les mouvements respiratoires peuvent entrainer des artefacts de uniformité lors de la reconstruction des images de perfusion myocardique en SPECT. Dans cet article, nous rapportons nos résultats sur le bénéfice potentiel du « gating » respiratoire avec des doses standards et réduites de radio-pharmaceutiques pour la détection des anomalies de perfusion et les mesures de la paroi ventriculaire gauche. Méthodes: Nous avons appliqué deux méthodes de reconstruction pour la correction du mouvement respiratoire: la première fait appel a une correction après reconstruction des images (PMC) ; la seconde fait appel à la correction des images avant reconstruction (MRC). Les deux approches ont été comparées à la reconstruction sans correction de mouvement (Non-MC). Nous avons quantifié les déficits de perfusion myocardiques sur les images reconstruites avec le système des scores de déficit de perfusion et analysé les résultats en utilisant les courbes ROC. Nous avons quantifié la résolution spatiale du VG en utilisant le FWHM du profil d’intensité de sa section transversale. Résultats: Les valeurs des surfaces en dessous des courbes ROC (AUC) obtenues par MCR, PMC et Non-MC avec doses standard de radio-pharmaceutiques étaient de 0,835, 0,830 et 0,798, respectivement. Des améliorations similaires de l’AUC ont également été obtenues par MCR et PMC sur Non-MC avec 50%, 25% et 12,5% des doses entières. Les mesures de résolution spatiale de la paroi du VG ont également été améliorées avec la correction des mouvements respiratoires. Conclusions: La correction des images de perfusion myocardiques en SPECT par « gating » respiratoire paraît améliorer la quantification des déficits perfusionels à la fois à dose standard et à dose réduite de radio-pharmaceutiques. L’application de cette correction devrait permettre de réduire les doses de radio-pharmaceutiques utilisées tout en maintenant la précision diagnostique des acquisitions traditionnelles. [Spanish] Spanish Abstract: Antecedentes: En los estudios de perfusión cardiaca por SPECT, los movimientos respiratorios pueden causar distorsión no uniforme en el miocardio reconstruido. Investigamos el beneficio potencial de la corrección respiratoria con adquisición de imágenes sincronizadas con la respiración, tanto a dosis estándar como a dosis reducida, para detección de defectos y para resolución de pared de ventrículo izquierdo (VI). Métodos: Aplicamos dos métodos de reconstrucción para corrección de movimientos respiratorios: Corrección de movimiento post reconstrucción (PMC) y reconstrucción compensada a movimiento (MCR), y los comparamos con la reconstrucción sin corrección de movimiento (Non-MC). Cuantificamos la presencia de defectos de perfusión en las imágenes reconstruidas usando los scores de déficit total de perfusión (TPD) y análisis ROC usando el TPD. Cuantificamos la resolución espacial del VI usando la anchura a media altura de su perfil de intensidad transversal. Resultados: Los valores en el área bajo la curva ROC (ABC) obtenidos por MCR, PMC y Non-MC a dosis estándar fueron 0.835, 0.830 y 0.798, respectivamente. Mejorías similares del ABC también se obtuvieron por MCR y PMC, sobre Non-MC a 50%, 25% y 12.5% de la dosis completa. Las mejorías en la resolución del VI fueron observadas también con corrección del movimiento. Conclusiones: Las adquisiciones sincronizadas con la respiración pueden mejorar la precisión de la detección de defectos de perfusión sobre las reconstrucciones tradicionales tanto a dosis estándar como a dosis reducida. La corrección de movimiento puede contribuir a lograr mayor reducción de la dosis manteniendo la precisión diagnóstica de las adquisiciones tradicionales. [Chinese] Chinese Abstract: 背景: 在心脏 SPECT 灌注成像中, 呼吸运动会导致心肌重建的不均匀模糊。我们研究了无论是标准剂量还是减少剂量的情况下, 呼吸跟踪采集的呼吸校正用于图像缺损检测和左心室 (LV) 室壁分辨率的潜在益处。 方法: 我们使用了两种呼吸运动校正的重建方法:重建后运动校正 (PMC) 和运动补偿重建 (MCR), 并与没有运动校正的重建 (Non-MC) 进行比较。 通过总灌注缺损 (TPD) 评分和其接受者操作特性曲线 (ROC) 来量化重建图像中的灌注缺陷。通过LV横截面强度分布的 FWHM来量化 LV 空间分辨率。 结果: MCR, PMC 和 Non-MC 在标准剂量下所获得的 ROC 曲线下面积 (AUC) 的值分别为0.835, 0.830 和 0.798。 在全剂量下, MCR, PMC和 Non-MC也获得类似的 AUC 提高, 分别为 50%, 25% 和 12.5%。 在运动校正下, LV的分辨率也得到了改善。 结论: 在标准剂量和减少剂量的情况下, 呼吸跟踪采集可以改善灌注缺损检测的准确性。 运动校正可能有助于进一步实现减少剂量的目标, 同时保证通过传统检测方法的诊断准确性。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pitfalls in Prediction Modeling for Normal Tissue Toxicity in Radiation Therapy: An Illustration With the Individual Radiation Sensitivity and Mammary Carcinoma Risk Factor Investigation Cohorts

Purpose: To identify the main causes underlying the failure of prediction models for radiation therapy toxicity to replicate. Methods and Materials: Data were used from two German cohorts, Individual Radiation Sensitivity (ISE) (n=418) and Mammary Carcinoma Risk Factor Investigation (MARIE) (n=409), of breast cancer patients with similar characteristics and radiation therapy treatments. The toxicity endpoint chosen was telangiectasia. The LASSO (least absolute shrinkage and selection operator) logistic regression method was used to build a predictive model for a dichotomized endpoint (Radiation Therapy Oncology Group/European Organization for the Research and Treatment of Cancer score 0, 1, or ≥2). Internal areas under the receiver operating characteristic curve (inAUCs) were calculated by a naïve approach whereby the training data (ISE) were also used for calculating the AUC. Cross-validation was also applied to calculate the AUC within the same cohort, a second type of inAUC. Internal AUCs from cross-validation were calculated within ISE and MARIE separately. Models trained on one dataset (ISE) were applied to a test dataset (MARIE) and AUCs calculated (exAUCs). Results: Internal AUCs from the naïve approach were generally larger than inAUCs from cross-validation owing to overfitting the training data. Internal AUCs from cross-validation were also generally larger than the exAUCs, reflecting heterogeneity in the predictors between cohorts. The best models with largest inAUCs from cross-validation within both cohorts had a number of common predictors: hypertension, normalized total boost, and presence of estrogen receptors. Surprisingly, the effect (coefficient in the prediction model) of hypertension on telangiectasia incidence was positive in ISE and negative in MARIE. Other predictors were also not common between the 2 cohorts, illustrating that overcoming overfitting does not solve the problem of replication failure of prediction models completely. Conclusions: Overfitting and cohort heterogeneity are the 2 main causes of replication failure of prediction models across cohorts. Cross-validation and similar techniques (eg, bootstrapping) cope with overfitting, but the development of validated predictive models for radiation therapy toxicity requires strategies that deal with cohort heterogeneity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗