Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Atomic Weapons Establishment (AWE)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Radiochronometric discordance in cast uranium metal: a multi-laboratory intercomparison exercise

Here, the model age of a nuclear material is crucial in nuclear forensic analysis. Uranium metals with complex production histories often exhibit discordant model ages from the 230 Th– 234 U and 231 Pa– 235 U chronometers. Recent studies involving targeted uranium metal castings have enhanced our understanding of decay product behavior during casting, aiding nuclear forensic interpretation. Building on this prior work, forensics laboratories at Atomic Weapons Establishment (AWE), Lawrence Livermore National Laboratory (LLNL), and Los Alamos National Laboratory (LANL) conducted an interlaboratory comparison to investigate spatial heterogeneity in uranium metal cast under controlled conditions. Each laboratory measured samples of a mixed feedstock and its corresponding cast product. This work furthers our understanding of discordant model ages and the use of discordance as a signature to enhance confidence in interpretations of radiochronometric data for nuclear forensics.

230Th/234U↗

IER 500: AWE-LLNL Measurement Campaign at DAF [Slides]

Presentation Hosted at Device Assembly Facility (DAF). Joint collaboration by Atomic Weapons Establishment (AWE) and Lawrence Livermore National Laboratory (LLNL). Multiple measurements were recorded through a two-week period with 12 unique objects measured. LLNL deployed Machine learning software program for diagnostic assessments. Current status notes the dedicated DAF team LLNL maintains. Additionally, LLNL is compiling a report on the AWE-LLNL measurements and designing security benchmark experiments. The presentation concludes with future work envisioned.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of radioxenon activities during periods of gaseous release from an advanced gas-cooled reactor

Activities of radioxenon isotopes are reported from an Advanced Gas-cooled Reactor (AGR) during periods of gaseous release. Xenon isotopes are relevant to the monitoring regime of the Comprehensive Nuclear-Test-Ban Treaty (CTBT). These releases may affect detections from the International Monitoring System (IMS) by influencing the radioxenon background. Time series activity plots have been produced from both in-core monitoring and direct measurement at the point of release using a stack monitor system. Ratio plots using both data sets have been produced with results compared with a commonly chosen nuclear explosion “discrimination line.” The reported results improve the understanding of radionuclide emissions from civil nuclear power plants. This work is being performed as part of the Xenon Environmental Nuclide Analysis at Hartlepool (XENAH) collaboration between the Atomic Weapons Establishment (AWE, UK), EDF Energy (UK), Pacific Northwest National Laboratory (PNNL, USA), and the Swedish Defence Research Agency (FOI).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

International Intercomparison for Nuclear Accident Dosimetry Using Godiva-IV

During the week of August 22, 2022, Integral Experiment Request (IER) 538, an international blind intercomparison for nuclear accident dosimetry (NAD) exercise, was completed using the Godiva-IV critical assembly at the National Criticality Experiments Research Center (NCERC) located in the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS). This exercise builds upon a series of experiments that include the characterization the radiation fields around Godiva (IER-147) and Flattop (IER-252) and follow up intercomparisons of dosimetry around both Godiva IV and Flattop (IER-148 and IER-253, respectively). The participants consisted of seven Department of Energy laboratories and one laboratory each from the US Navy, United Kingdom, and France. The participants of the exercise were Lawrence Livermore National Laboratory (LLNL); Los Alamos National Laboratory (LANL); Sandia National Laboratory (SNL); Savannah River Site (SRS); Hanford Site, Missions Support and Test Services (MSTS); Y-12 National Security Complex (Y-12); Naval Dosimetry Center (NDC); Atomic Weapons Establishment (AWE); and Institut de Radioprotection et de Sûreté Nucléaire (IRSN). MSTS dosimeters were included in the irradiations but not reported for evaluation. This report primarily discusses the performance of the 24 hour results submitted by participants, though available final results are briefly discussed. Information for each irradiation performed is provided for participating laboratories to produce their own final report which will be incorporated into the CED-4a report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IER-484 CED3b Report: AFRRI ER1 Dosimetry Characterization

This report presents the preliminary work for IER 484, the characterization of the leakage radia tion field from the TRIGA reactor at the Armed Forces Radiobiology Research Institute (AFRRI). The purpose of the dose characterization is to establish the reference dose needed to execute a NAD inter-comparison exercise. During the week of August 20th, a team from Lawrence Livermore National Laboratory (LLNL), Sandia National Laboratory (SNL), and Institut de Radioprotection et de Sûreté Nucléaire (IRSN) performed various measurements in AFRRI’s TRIGA ER1 (Exposure Room 1) with Passive Neutron Spectrometer (PNS) spheres and nuclear accident dosimeters (NADs) mounted on Bottle Manikin Absorption (BOMAB) phantoms (to simulate doses received by people) and additional NADs mounted on aluminum plates (to simulate doses in free air). Without Atomic Weapons Establishment (AWE), LLNL became responsible for measuring the neutron spectrum using PNS spheres. SNL is responsible for providing photon dose data. LLNL, SNL, and IRSN each deployed their own NADs, which will be compared to the reference dose measured. Final characterization of the dose field based on analyzed data will be presented in the CED4a report.

42 ENGINEERING↗

Improvements to the 115g/115m Cd Nuclear Data

Repeated measurements of the isotope 115m Cd by Los Alamos National Laboratory (LANL), Pacific Northwest National Laboratory (PNNL), and Atomic Weapons Establishment (AWE) have revealed a consistent discrepancy between beta and gamma counting. This suggests that a significant disparity exists between the true value of the isotope’s gamma-ray branching ratios and the values reported by the National Nuclear Data Center (NNDC). Enriched 114 Cd was irradiated using thermal neutrons to produce a high-purity 115m/g Cd source for counting and analysis using traditional singles gamma-ray spectroscopy, liquid scintillation counting, gas-proportional counting, and analysis using the new Gamma-Alpha-Beta-Gamma (GABγ) and Gamma-Alpha-Beta Radio-Isotope EvaLuator (GABRIEL) coincidence detection systems. Using the D-T fusion generated neutrons, reduces the wait time required to let the short-lived 115Cd ground state decay away by leveraging the 1:1 production ratio of the ground and metastable state of 115 Cd from the 115 In (n,p) reaction relative to the 10:1 production ratio of the ground and metastable isotopes of 115 Cd by thermal neutron capture on 114 Cd. However, the much higher flux in from the Washington State University TRIGA reactor is a more rapid method of production of 115m/gCd but requires access to enriched 114 Cd. High purity 115m/g Cd samples were analyzed on regular intervals over a period of 140-days. The activity of 115m Cd measured by beta and gamma show a clear discrepancy using the current best known gamma-ray decay branching ratios. Based on these observations and measurements, a set of new branching ratio recommendations have been produced using conventional counting techniques and the advanced GAB? and GABRIEL instruments.

07 ISOTOPE AND RADIATION SOURCES↗

Godiva-IV Dosimetry Exercise 2022 Preliminary Results

Integral Experiment Request (IER) 538 is part of a series of dose characterization and nuclear accident dosimetry (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). This is the second NAD exercise using the Godiva-IV critical assembly and the third NAD exercise overall. The participating laboratories provided their own dosimeters that were mounted on the Lawrence Livermore National Laboratory (LLNL) BOttle Manikin ABsorption (BOMAB) phantoms and aluminum plates. The BOMABs and plates were placed at two, three, and four meters away from the center of Godiva. Alongside the NADs, there was a LLNL Passive Neutron Spectrometer (PNS), Atomic Weapons Establishment (AWE) PNS, and Y-12 Sphere present to measure the neutron dose from Godiva. Two irradiations were conducted to test the NAD performance from each laboratory and assesses their performance to the DOE-STD-1098-2017 part 515 criteria. Neutron and gamma doses were measured prior to this exercise. This work presents a model for the neutron and gamma dose respectively to serve as the reference value. A code written in C/C++/ROOT was used to fit the measured neutron and gamma dose with the new models. It was assumed that the neutron and gamma doses are proportional to the change in temperature of Godiva after a burst irradiation. Uncertainties for the reference values were calculated using error propagation of the model’s parameters. Preliminary results (within twenty-four hours) and final results were compared for each laboratory. On average of all the participating laboratories, 32% of neutron doses and 78% of gamma doses were outside the DOE standards. One laboratory did not report their dose readings and were not included in this average. There is a bias for a lower neutron dose and a higher gamma dose based on the distribution of results. In comparison with the past Godiva-IV NAD exercise, there is an improvement in neutron dose readings by 20%.

BOttle Manikin ABsorption (BOMAB)↗

Laser-driven high-resolution MeV x-ray tomography

The need for high-resolution MeV x-ray tomography to observe the three-dimensional structure of dense, large-sized objects is rapidly increasing for the non-destructive evaluation of critical additively manufactured parts, national security, and other applications. We report a demonstration of high-resolution MeV computed tomography of a dense, large object with a laser-driven x-ray source. A record detector-limited MeV radiograph resolution of < 200 µm as determined with the Bennett approximation of the point spread function was achieved by irradiating millimeter-thick tungsten targets with 300 TW femtosecond laser pulses at a 0.5 Hz repetition rate. A tungsten alloy step wedge spectrometer indicates that the peak of the x-ray emission is between 1 and 2 MeV, with an endpoint energy of 19 MeV. To illustrate the radiographic imaging capability of the system, a tomographic reconstruction of a nickel superalloy turbine blade ( maximum $ρr$ = 139 g/cm 2 ) with sub-millimeter resolution was performed using 2160 individual radiographs. The small x-ray source size opens the prospect of extremely high-resolution tomographs of large, dense objects. This laser-driven approach has major advantages for non-destructive evaluation.

47 OTHER INSTRUMENTATION↗

Analysis of 127 Xe tracer measurements using a net counts method

A suite of measurement systems were deployed as part of the Physical Experiment 1 series of experiments, which involved detonating chemical explosives along with radionuclide tracers in an underground cavity, at the Nevada National Security Site (NNSS) in the United States. One of the radionuclide tracers, 127 Xe was released from the containment following the explosion and detected on a SAUNA Q B sampler situated approximately 3.5 km away. The system uses a beta-gamma coincidence detector system to measure fission product radioisotopes of xenon relevant to nuclear explosion monitoring. In this work we use the coincidence measurement data to analyse and interpret the results from the SAUNA Q B system, to calculate the measured 127 Xe activity concentration(s).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Analysis of measurements from an array of radioxenon samplers near to Hartlepool Nuclear Power Station

As part of a scientific research and development project, the radionuclide fingerprint of an operating advanced gas-cooled reactor 25 (AGR) has been studied across several facets (Goodwin et al., 2024). One part of this project was to deploy an array of 26 radioxenon samplers to the region for a period of around 1 year, to measure any radioxenon emissions from the reactors of the 27 Hartlepool nuclear power station at a range of tens of kilometres away. The array of 3 sensors was operational for around 12 28 months from March 2022 and detected many occurrences of isotopes of radioxenon. Here we provide a detailed analysis and 29 interpretation of the data and where possible, attribution of detections to a source or region. Whilst a key part of this work is to 30 measure any emissions of radioxenon from Hartlepool, this work presents one of the most comprehensive efforts to determine the 31 source of a great number of (mostly) 133Xe detections. A combination of different types of atmospheric dispersion modelling 32 techniques, including the use of stack monitoring data from nearby civil radioxenon-emitting nuclear facilities has enabled the 33 majority of detections to be attributed to one or more possible sources. Whilst emissions from Hartlepool have been detected on 34 the systems, the majority of detections are associated with a medical isotope production facility in Fleurus, Belgium (IRE).

Advanced gas-cooled reactor↗

Updated Results of the Nuclear Accident Dosimetry Intercomparison at the Armed Forces Radiobiology Research Institute’s TRIGA Reactor (IER-602 CED-4a Report)

The IER-602 3b document (Angus, et al. 2024) reported the initial, 24-hour results of the international nuclear accident intercomparison, which took place at the Armed Forces Radiobiological Research Institute during June 24-28, 2024. This report provides updated results and further analysis of the intercomparison.

61 RADIATION PROTECTION AND DOSIMETRY↗

Detecting 127 Xe in an atmospheric tracer experiment

The Xcounts algorithm for calculating air concentrations of radioactive xenon isotopes (Eslinger et al., 2023) has been extended to estimate 127 Xe in addition to 131m Xe, 133m Xe, 133 Xe, and 135 Xe. The algorithm was applied to 119 samples collected with a SAUNA Q B system (Ringbom et al., 2023) during a two-month atmospheric tracer release experiment. Finally, the algorithm identified two samples with 127 Xe present from a single 1.5 h release about 3.5 km upwind of the sampler and no false detections of 127 Xe were observed in the other samples.

127Xe calibration↗

Seismic DAS observations of a large underground chemical explosion in dry tuff

On 18 October 2023 a 16.3-ton TNT equivalent chemical explosion was detonated underground at the Nevada National Security Site, generating a seismic event with a magnitude of 1.7 (Meyers et al., 2024). The associated seismic wavefield was measured on a Distributed Acoustic Sensing (DAS) array with slant range distances from 27 m – 1123 m. The first arriving phase traveled at an apparent velocity of about 2640 m s -1 from 27 m to 420 m slant range and about 2470 m s -1 from 505 m to 1123 m slant range according to the first arrival moveouts on the DAS data. The first arrival from the explosion temporarily saturated the cable from a slant range of 27 m – 186 m and 0.009 s to 0.084 s post detonation. From 186 m slant range to 420 m slant range, peak strain rates of 5.6 x 10 6 nm m -1 s -1 were observed for the first arrival phase. For the first arrival from 505 m slant range to 1123 m slant range, peak strain rates reduced to 8.0 x 104 nm m -1 s -1 . A comparison of the scaled accelerations computed from DAS, the geophone pairs, and the measurements of co-located accelerometer pairs show common agreement at the scaled ranges of the single point sensors. This study adds to the body of work reporting near-source DAS observations of the seismic wavefields generated by underground chemical explosions. These results indicate that near-source DAS observations can refine interpretations of phase identification from single-point sensor observations. Phase identification could be one mechanism that contributes scatter to single point seismic measurements which would confound the performance of empirical relationships for small explosions. Removing that mechanism may therefore reduce interstation variability and increase empirical relationship performance for small explosions.

58 GEOSCIENCES↗

Assessment of rare earth element fractionation in NIF implosions with radiochemically doped capsules

An ongoing experimental campaign at the National Ignition Facility (NIF) aims to measure neutron induced nuclear reaction cross–sections using radiochemically doped target capsules. Critical to this campaign is the ability to collect a representative sample of the reaction products using Solid Radiochemical Collectors (SRCs) fielded around the NIF chamber. The shot presented in this paper used a doped target capsule with a neopentane gas fill was to investigate the ratio of isotopes collected at three chamber angles. It was found that SRC samples of rare earth elements collected from NIF are representative of the ingoing dopant mix, thereby concluding that fractionation does not occur during a NIF implosion. This validates the doped capsule method for use in measuring neutron induced reaction cross-sections.

Capsule Doping↗

Femtosecond temperature measurements of laser-shocked copper deduced from the intensity of the x-ray thermal diffuse scattering

We present 50-fs, single-shot measurements of the x-ray thermal diffuse scattering (TDS) from copper foils that have been shocked via nanosecond laser ablation up to pressures above ∼135 GPa. We hence deduce the x-ray Debye–Waller factor, providing a temperature measurement. The targets were laser-shocked with the DiPOLE 100-X laser at the High Energy Density endstation of the European X-ray Free-Electron Laser. Single x-ray pulses, with a photon energy of 18 keV, were scattered from the samples and recorded on Varex detectors. Despite the targets being highly textured (as evinced by large variations in the elastic scattering) and with such texture changing upon compression, the absolute intensity of the azimuthally averaged inelastic TDS between the Bragg peaks is largely insensitive to these changes, and allowing for both Compton scattering and the low-level scattering from a sacrificial ablator layer provides a reliable measurement of $T/Θ^2_D$, where Θ D is the Debye temperature. We compare our results with the predictions of the SESAME 3336 and LEOS 290 equations of state for copper and find good agreement within experimental errors. We, thus, demonstrate that single-shot temperature measurements of dynamically compressed materials can be made via thermal diffuse scattering of XFEL radiation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

X-ray thermal diffuse scattering as a texture-robust temperature diagnostic for dynamically compressed solids

We present a model of x-ray thermal diffuse scattering (TDS) from a cubic polycrystal with an arbitrary crystallographic texture, based on the classic approach of Warren [B. E. Warren, Acta Crystallogr. 6, 803 (1953)]. We compare the predictions of our model with femtosecond x-ray diffraction patterns gathered from ambient and dynamically compressed rolled copper foils obtained at the High Energy Density instrument of the European X-Ray Free-Electron Laser facility and find that the texture-aware TDS model yields more accurate results than does the conventional powder model owed to Warren. Nevertheless, we further show: with sufficient angular detector coverage, the TDS signal is largely unchanged by sample orientation and in all cases strongly resembles the signal from a perfectly random powder; shot-to-shot fluctuations in the TDS signal resulting from grain-sampling statistics are at the percent level, in stark contrast to the fluctuations in the Bragg-peak intensities (which are over an order of magnitude greater); and TDS is largely unchanged even following texture evolution caused by compression-induced plastic deformation. We conclude that TDS is robust against texture variation, making it a flexible temperature diagnostic applicable just as well to off-the-shelf commercial foils as to ideal powders.

Crystal lattices↗

NCSP – AWE Collaboration [Slides]

Several points of collaboration between NCSP and AWE are noted, including the CIDAAS IS589 installation plan, CIDAAS testing, nuclear verification and detector physics, nuclear material control and nuclear security, and hands on criticality safety training.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

127 Xe quantification method development and intercomparison exercise

Monitoring of the atmosphere for fission products ( 131m Xe, 133m Xe, 133 Xe, and 135 Xe) is performed by various laboratories to detect nuclear explosions. Quantification of 127 Xe is not routinely performed by laboratories measuring atmospheric radioxenon because it is not a fission product. 127 Xe was recently detected by a ground-based beta-gamma air monitoring system. When measured using beta-gamma coincidence detector systems, such as those in use on the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), 127 Xe can interfere with the quantification of fission product radioxenon due to overlap of the 127 Xe beta-gamma coincidence signatures with those of fission product radioxenon. Here, this work demonstrates quantification of 127 Xe at different laboratories with different measurement techniques. Production and purification of 127 Xe was performed by neutron activation of enriched 126 Xe. The purified 127 Xe was then split between laboratories, and detection and quantification methods were developed. At Idaho National Laboratory, a quantification method involving high purity germanium detectors was devised that included self-attenuation correction. At AWE, a beta-gamma coincidence counting method, as used in support of the IMS, was modified to enable the measurement and analysis of the 127 Xe samples. Corrections were made for self-attenuation, which showed a strong xenon volume dependency, for some coincidence signatures. The gas sample activity concentration was used as the comparison metric and it showed excellent agreement between the methods.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗