Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Assays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

FRET-Aptamer Assays for Bone Marker Assessment, C-Telopeptide, Creatinine, and Vitamin D

Astronauts lose 1.0 to 1.5% of their bone mass per month on long-duration spaceflights. NASA wishes to monitor the bone loss onboard spacecraft to develop nutritional and exercise countermeasures, and make adjustments during long space missions. On Earth, the same technology could be used to monitor osteoporosis and its therapy. Aptamers bind to targets against which they are developed, much like antibodies. However, aptamers do not require animal hosts or cell culture and are therefore easier, faster, and less expensive to produce. In addition, aptamers sometimes exhibit greater affinity and specificity vs. comparable antibodies. In this work, fluorescent dyes and quenchers were added to the aptamers to enable pushbutton, one-step, bind-and-detect fluorescence resonance energy transfer (FRET) assays or tests that can be freeze-dried, rehydrated with body fluids, and used to quantitate bone loss of vitamin D levels with a handheld fluorometer in the spacecraft environment. This work generated specific, rapid, one-step FRET assays for the bone loss marker C-telopeptide (CTx) when extracted from urine, creatinine from urine, and vitamin D congeners in diluted serum. The assays were quantified in nanograms/mL using a handheld fluorometer connected to a laptop computer to convert the raw fluorescence values into concentrations of each analyte according to linear standard curves. DNA aptamers were selected and amplified for several rounds against a 26- amino acid form of CTx, creatinine, and vitamin D. The commonalities between loop structures were studied, and several common loop structures were converted into aptamer beacons with a fluorophore and quencher on each end. In theory, when the aptamer beacon binds its cognate target (CTx bone peptide, creatinine, or vitamin D), it is forced open and no longer quenched, so it gives off fluorescent light (when excited) in proportion to the amount of target present in a sample. This proportional increase in fluorescence is called a "lights on" FRET response. The vitamin D aptamer beacon gives a "lights off" or inversely proportional fluorescence response to the amount of vitamin D present in diluted serum. These FRET-aptamer assays are rapid (<30 minutes), sensitive (low ng/mL detection limits), and quite easy to carry out (add sample, mix, and detect in the handheld reader). Benefits include the speed of the assays as well as the small amount of space taken up by the handheld reader and cuvette assays. The aptamer DNA sequences represent novel additional features of the existing (patent-pending) FRET-aptamer assay platform.

Bruno, John G.

Lessons from Astrobiological Planetary Analogue Exploration in Iceland: Biomarker Assay Performance and Downselection

Understanding the sensitivity of biomarker assays to the local physicochemical environment, and the underlying spatial distribution of the target biomarkers in 'homogeneous' environments, can increase mission science return. We have conducted four expeditions to Icelandic Mars analogue sites in which an increasingly refined battery of physicochemical measurements and biomarker assays were performed, staggered with scouting of further sites. Completed expeditions took place in 2012 (location scouting and field assay use testing), 2013 (sampling of two major sites with three assays and observational physicochemical measurements), 2015 (repeat sampling of prior sites and one new site, scouting of new sites, three assays and three instruments), and 2016 (preliminary sampling of new sites with analysis of returned samples). Target sites were geologically recent basaltic lava flows, and sample loci were arranged in hierarchically nested grids at 10 cm, 1 m, 10 m, 100 m, and >1 km order scales, subject to field constraints. Assays were intended to represent a diversity of potential biomarker types (cell counting via nucleic acid staining and fluorescence microscopy, ATP quantification via luciferase luminescence, and relative DNA quantification with simple domain-level primers) rather a specific mission science target, and were selected to reduce laboratory overhead, require limited consumables, and allow rapid turnaround. All analytical work was performed in situ or in a field laboratory within a day's travel of the field sites unless otherwise noted. We have demonstrated the feasibility of performing ATP quantification and qPCR analysis in a field-based laboratory with single-day turnaround. The ATP assay was generally robust and reliable and required minimal field equipment and training to produce a large amount of useful data. DNA was successfully extracted from all samples, but the serial-batch nature of qPCR significantly limited the number of primers (hence classifications) and replicates that could be run in a single day. Fluorescence microscopy did not prove feasible under the same constraints, primarily due to the large number of person-hours required to view, analyze, and record results from the images; however, this could be mitigated with higher-quality imaging instruments and appropriate image analysis software.

Planetary

Martian Superoxide and Peroxide O2 Release (OR) Assay: A New Technology for Terrestrial and Planetary Applications

This study presents an assay for the detection and quantification of soil metal superoxides and peroxides in regolith and soil. The O2 release (OR) assay is based on the enzymatic conversion of the hydrolysis products of metal oxides to O2, and their quantification by an O2 electrode based on the stoichiometry of the involved reactions: The intermediate product O2 from the hydrolysis of metal superoxides is converted by cytochrome c to O2, and also by superoxide dismutase (SOD) to 1/2 mol O2 and 1/2 mol H2O2, which is then converted by catalase (CAT) to 1/2 mol O2. The product H2O2 from the hydrolysis of metal peroxides and hydroperoxides is converted to 1/2 mol O2 by CAT. The assay-method was validated in a sealed sample chamber using a liquid-phase Clark-type O2 electrode with known concentrations of O2 and H2O2, and with commercial metal superoxide and peroxide mixed with Mars analogue Mojave and Atacama Desert soils. Carbonates and perchlorates, both present on Mars, do not interfere with the assay. The assay lower limit of detection, using luminescence quenching/optical sensing O2-electrodes, is 1 nmol O2 cm(exp. -3) or better. The activity of the assay enzymes SOD and cytochrome c was unaffected up to 6 Gy exposure by gamma-radiation, while CAT retained 100% and 40% of its activity at 3 and 6 Gy, respectively, demonstrating the suitability of these enzymes for planetary missions, e.g., in Mars or Europa.

soil metal superoxides and peroxides

Biochemical assays on plasminogen activators and hormones from kidney sources

Investigations were established for the purpose of analyzing the conditioned media from human embryonic kidney cell subpopulations separated in space by electrophoresis. This data is based on the experiments performed on STS-8 on the continuous flow electrophoresis system. The primary biological activity that was analyzed was plasminogen activator activity, but some assays for erythropoeitin and human granulocyte colony stimulating activity were also performed. It is concluded that a battery of assays are required to completely define the plasminogen activator profile of a conditioned media from cell culture. Each type of assay measures different parts of the mixture and are influenced by different parameters. The functional role of each assay is given along with an indication of which combination of assays are required to answer specific questions. With this type of information it is possible by combinations of assays with mathematical analysis to pinpoint a specific component of the system.

Barlow, Grant H.

Developing A Miniaturized Biology Assay for the Astrobiology Search Kit

Partnering with Retego Labs we will develop an acetate assay to use in the Astrobiology Search Kit advanced spectrometer. Our current knowledge of metabolic pathways (methanogeneis, and acetogenesis) both produce acetate. There is no known method of producing acetate abiotically, therefore the detection of acetate indicates the presence of biology. There is no current assays to directly detect acetate. We would be developing the first assay. Our development plan is based on the development of previous assays. We start with EPA standards then modify and increase the sensitivity based on our detection needs. In this case the detection is 10^2 cells/ml equivalent. This assay would be useful on Titan where if life exists the biogeochemistry is methane based instead of water based like Earth (possibly Mars, Europa).

H. Smith

Metabolic response of environmentally isolated microorganisms to industrial effluents: Use of a newly described cell culture assay

An environmental application using a microtiter culture assay to measure the metabolic sensitivity of microorganisms to petrochemical effluents will be tested. The Biomedical Operations and Research Branch at NASA JSC has recently developed a rapid and nondestructive method to measure cell growth and metabolism. Using a colorimetric procedure the uniquely modified assay allows the metabolic kinetics of prokaryotic and eukaryotic cells to be measured. Use of such an assay if adapted for the routine monitoring of waste products, process effluents, and environmentally hazardous substances may prove to be invaluable to the industrial community. The microtiter method as described will be tested using microorganisms isolated from the Galveston Bay aquatic habitat. The microbial isolates will be identified prior to testing using the automated systems available at JSC. Sodium dodecyl sulfate (SDS), cadmium, and lead will provide control toxic chemicals. The toxicity of industrial effluent from two industrial sites will be tested. An effort will be made to test the efficacy of this assay for measuring toxicity in a mixed culture community.

Ferebee, Robert N.

Microelectronic DNA assay for the detection of BRCA1 gene mutations

Mutations in BRCA1 are characterized by predisposition to breast cancer, ovarian cancer and prostate cancer as well as colon cancer. Prognosis for this cancer survival depends upon the stage at which cancer is diagnosed. Reliable and rapid mutation detection is crucial for the early diagnosis and treatment. We developed an electronic assay for the detection of a representative single nucleotide polymorphism (SNP), deletion and insertion in BRCA1 gene by the microelectronics microarray instrumentation. The assay is rapid, and it takes 30 minutes for the immobilization of target DNA samples, hybridization, washing and readout. The assay is multiplexing since it is carried out at the same temperature and buffer conditions for each step. The assay is also highly specific, as the signal-to-noise ratio is much larger than recommended value (72.86 to 321.05 vs. 5) for homozygotes genotyping, and signal ratio close to the perfect value 1 for heterozygotes genotyping (1.04).

Validation Studies

Application of luciferase assay for ATP to antimicrobial drug susceptibility

The susceptibility of bacteria, particularly those derived from body fluids, to antimicrobial agents is determined in terms of an ATP index measured by culturing a bacterium in a growth medium. The amount of ATP is assayed in a sample of the cultured bacterium by measuring the amount of luminescent light emitted when the bacterial ATP is reacted with a luciferase-luciferin mixture. The sample of the cultured bacterium is subjected to an antibiotic agent. The amount of bacterial adenosine triphosphate is assayed after treatment with the antibiotic by measuring the luminescent light resulting from the reaction. The ATP index is determined from the values obtained from the assay procedures.

Chappelle, E. W.

Application of firefly luciferase assay for adenosine triphosphate (ATP) to antimicrobial drug sensitivity testing

The development of a rapid method for determining microbial susceptibilities to antibiotics using the firefly luciferase assay for adenosine triphosphate (ATP) is documented. The reduction of bacterial ATP by an antimicrobial agent was determined to be a valid measure of drug effect in most cases. The effect of 12 antibiotics on 8 different bacterial species gave a 94 percent correlation with the standard Kirby-Buer-Agar disc diffusion method. A 93 percent correlation was obtained when the ATP assay method was applied directly to 50 urine specimens from patients with urinary tract infections. Urine samples were centrifuged first to that bacterial pellets could be suspended in broth. No primary isolation or subculturing was required. Mixed cultures in which one species was predominant gave accurate results for the most abundant organism. Since the method is based on an increase in bacterial ATP with time, the presence of leukocytes did not interfere with the interpretation of results. Both the incubation procedure and the ATP assays are compatible with automation.

Picciolo, G. L.

Novel Confocal Microscopic and Flow Cytometric Based Assays to Visualize and Detect the (Beta)2-Adrenergic Receptor in Human Lymphocyte and Mononuclear Cell Populations

The data show that immunophenotyping of leukocyte populations with (beta)2AR is possible with the commercially available Ab, although the FC assay is limited to the IST as a result of the Ab binding site to the intracellular C-terminus of the 2AR. The FC assay has applications for measuring alterations in total (beta)2AR in human leukocyte populations as changes in fluorescence. In addition, CM confirms that both surface and intracellular compartments stain positively for the (beta)2AR and can be used for qualitative assays that screen for changes in receptor compartmentalization and localization.

Salicru, A. N.

Surface Bacterial-Spore Assay Using Tb3+/DPA Luminescence

Equipment and a method for rapidly assaying solid surfaces for contamination by bacterial spores are undergoing development. The method would yield a total (nonviable plus viable) spore count of a surface within minutes and a viable-spore count in about one hour. In this method, spores would be collected from a surface by use of a transparent polymeric tape coated on one side with a polymeric adhesive that would be permeated with one or more reagent(s) for detection of spores by use of visible luminescence. The sticky side of the tape would be pressed against a surface to be assayed, then the tape with captured spores would be placed in a reader that illuminates the sample with ultraviolet light and counts the green luminescence spots under a microscope to quantify the number of bacterial spores per unit area. The visible luminescence spots seen through the microscope would be counted to determine the concentration of spores on the surface. This method is based on the chemical and physical principles of methods described in several prior NASA Tech Briefs articles, including Live/Dead Spore Assay Using DPA-Triggered Tb Luminescence (NPO-30444), Vol. 27, No. 3 (March 2003), page 7a. To recapitulate: The basic idea is to exploit the observations that (1) dipicolinic acid (DPA) is present naturally only in bacterial spores; and (2) when bound to Tb3+ ions, DPA triggers intense green luminescence of the ions under ultraviolet excitation; (3) DPA can be released from the viable spores by using L-alanine to make them germinate; and (4) by autoclaving, microwaving, or sonicating the sample, one can cause all the spores (non-viable as well as viable) to release their DPA. One candidate material for use as the adhesive in the present method is polydimethysiloxane (PDMS). In one variant of the method for obtaining counts of all (viable and nonviable) spores the PDMS would be doped with TbCl3. After collection of a sample, the spores immobilized on the sticky tape surface would be lysed by heating or microwaving to release their DPA. Tb3+ ions from the TbCl3 would become bound to the released DPA. The tape would then be irradiated with ultraviolet and examined as described above. In another variant of the method - for obtaining counts of viable spores only - the PDMS would be doped with L-alanine in addition to TbCl3. As now envisioned, a fully developed apparatus for implementing this method would include a pulsed source of ultraviolet light and a time-gated electronic camera to record the images seen through the microscope during a prescribed exposure interval at a prescribed short time after an ultraviolet pulse. As in the method of the second-mentioned prior article, the pulsing and time-gating would be used to discriminate between the longer-lived Tb3+/DPA luminescence and the shorter-lived background luminescence in the same wavelength range. In a time-gated image, the bright luminescence from bacterial spores could easily be seen against a dark background.

Ponce, Adrian

Evaluation of an ATP Assay to Quantify Bacterial Attachment to Surfaces in Reduced Gravity

Aim: To develop an assay to quantify the biomass of attached cells and biofilm formed on wetted surfaces in variable-gravity environments. Methods and Results: Liquid cultures of Pseudomonas aeruginosa were exposed to 30-35 brief cycles of hypergravity (< 2-g) followed by free fall (i.e., reduced gravity) equivalent to either lunar-g (i.e., 0.17 normal Earth gravity) or micro-g (i.e., < 0.001 normal Earth gravity) in an aircraft flying a series of parabolas. Over the course of two days of parabolic flight testing, 504 polymer or metal coupons were exposed to a stationary-phase population of P. aeruginosa strain ERC1 at a concentration of 1.0 x 10(exp 5) cells per milliliter. After the final parabola on each flight test day, half of the material coupon samples were treated with either 400 micro-g/L ionic silver fluoride (microgravity-exposed cultures) or 1% formalin (lunar-gravity-exposed cultures). The remaining sample coupons from each flight test day were not treated with a fixative. All samples were returned to the laboratory for analysis within 2 hours of landing, and all biochemical assays were completed within 8 hours of exposure to variable gravity. The intracellular ATP luminescent assay accurately reflected cell physiology compared to both cultivation-based and direct-count microscopy analyses. Cells exposed to variable gravity had more than twice as much intracellular ATP as control cells exposed only to normal Earth gravity.

Birmele, Michele N.

Antibody binding in altered gravity: implications for immunosorbent assay during space flight

A single antibody-incubation step of an indirect, enzyme-linked immunosorbent assay (ELISA) was performed during microgravity, Martian gravity (0.38 G) and hypergravity (1.8 G) phases of parabolic flight, onboard the NASA KC-135 aircraft. Antibody-antigen binding occurred within 15 seconds; the level of binding did not differ between microgravity, Martian gravity and 1 G (Earth's gravity) conditions. During hypergravity and 1 G, antibody binding was directly proportional to the fluid volume (per microtiter well) used for incubation; this pattern was not observed during microgravity. These effects in microgravity may be due to "fluid spread" within the chamber (observed during microgravity with digital photography), leading to greater fluid-surface contact and subsequently antibody-antigen contact. In summary, these results demonstrate that: i) ELISA antibody-incubation and washing steps can be successfully performed by human operators during microgravity, Martian gravity and hypergravity; ii) there is no significant difference in antibody binding between microgravity, Martian gravity and 1 G conditions; and iii) a smaller fluid volume/well (and therefore less antibody) was required for a given level of binding during microgravity. These conclusions indicate that reduced gravity would not present a barrier to successful operation of immunosorbent assays during spaceflight.

NASA Discipline Environmental Health

Microbiologic assay of space hardware.

Review of the procedures used in the microbiological examination of space hardware. The general procedure for enumerating aerobic and anaerobic microorganisms and spores is outlined. Culture media and temperature-time cycles used for incubation are reviewed, along with assay systems designed for the enumeration of aerobic and anaerobic spores. The special problems which are discussed are involved in the precise and accurate enumeration of microorganisms on surfaces and in the neutralization of viable organisms buried inside solid materials that could be released to a planet's surface if the solid should be fractured. Special attention is given to sampling procedures including also the indirect techniques of surface assays of space hardware such as those using detachable or fallout strips. Some data on comparative levels of microbial contamination on lunar and planetary spacecraft are presented.

Favero, M. S.

Problem areas in the use of the firefly luciferase assay for bacterial detection

By purifying the firefly luciferase extract and adding all necessary chemicals but ATP in excess, an assay for ATP was performed by measuring the amount of light produced when a sample containing soluble ATP is added to the luciferase reaction mixture. Instrumentation, applications, and basic characteristics of the luciferase assay are presented. Effect of the growth medium and length of time grown in this medium on ATP per viable E. coli values is shown in graphic form, along with an ATP concentration curve showing relative light units versus ATP injected. Reagent functions and concentration methods are explored. Efforts to develop a fast automatable system to detect the presence of bacteria in biological fluids, especially urine, resulted in the optimization of procedures for use with different types of samples.

Picciolo, G. L.

A rapid method for the determination of microbial susceptibility using the firefly luciferase assay for adenosine triphosphate (ATP)

Luciferase assay for adenosine triphosphate (ATP) was optimized for pure bacteria in broth in order to evaluate if changes in bacterial ATP content could be used as a rapid measure of antibiotic effect on microorganisms. Broth cultures of log phase bacteria were incubated at 310 K (37 C) for 2.5 hours at antimicrobial concentrations which resulted in the best discrimination between sensitive and resistant strains. Eighty-seven strains of 11 bacterial species were studied for their susceptibility to 12 commonly used antimicrobial agents: ampicillin, Penicillin G, nafcillin, carbenicillin, cephalothin, tetracycline, erythromycin, clindamycin, gentamicin, nitrofurantoin, colistin, and chloramplenicol. The major advantage of the ATP system over existing methods of rapid microbial susceptibility testing is that the assay can be made specific for bacterial ATP.

Vellend, H.

Electrochemical Assay of Gold-Plating Solutions

Gold content of plating solution is assayed by simple method that required only ordinary electrochemical laboratory equipment and materials. Technique involves electrodeposition of gold from solution onto electrode, the weight gain of which is measured. Suitable fast assay methods are economically and practically necessary in electronics and decorative-plating industries. If gold content in plating bath is too low, poor plating may result, with consequent economic loss to user.

Chiodo, R.

Semi-microdroplet assay for cell adhesion molecules

A new cell-to-cell adhesion assay was devised. Using dissociated embryos of the sea urchin, this procedure involves rotating a 0.100 ml suspension of single cells with 0.100 ml of the solution to be tested in the bulb portion of a transfer pipet with the tip removed. After 1 hour of rotation at 60 rpm at 15 C, the contents of each bulb were transferred into individual wells of a 96 well flat bottom plate. After the plate was incubated for 1 hour at 15 C, black and white photographs were taken with a 35 mm camera attached to an inverted photomicroscope. Examining a proof sheet of the negatives directly allowed a rapid evaluation of suspected cell adhesion promoting factors. A ranking system was used to evaluate all samples. The assay was tested by examining the effect of specific solutions on the aggregation of single cells obtained from dissociated 23 hour embryos.

Tawa, Lawrence Shinzo