Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Peer-to-Peer Communication Trade-Offs for Smart Grid Applications: Preprint

Peer-to-peer energy management systems for smart grids require developers to consider the trade-offs between the amount of communication traffic generated and the quality and speed of convergence of the control algorithms that are deployed. Employing a fully connected communication causes messages to scale exponentially with the number of nodes, while using a sparse connectivity causes less information dissemination leading to degradation of the algorithm performance. The best communication topology for a particular application lies somewhere in between and often requires empirical evaluation by application designers. Existing methods do not put focus on the needs for smart grid applications, which is information dissemination throughout the network and they do not provide a flexible solution for application developers to prototype and deploy different topologies without modifying the application code. This paper introduces a configurable virtual communication topology framework TopLinkMgr, allowing users to specify any chosen communication topology and deploy peer-to-peer applications using it. It also introduces a self-adaptive, fault-tolerant topology management algorithm, Bounded Path Dissemination that can ensure the dissemination of information to all peers within a specified threshold for a sparsely connected topology. Experiments show that the algorithm improves on convergence speed and accuracy over state-of-the-art methods and is also robust against node failures. The results indicate the possibility of achieving a close-to optimal convergence without overloading the network allowing the realization of peer-to-peer control platforms covering larger and more complex power systems.

Bounded Path Dissemination↗

Application of the Aquifer Impact Model to support decisions at a CO 2 sequestration site

The National Risk Assessment Partnership (NRAP) has developed a suite of tools to assess and manage risk at CO 2 sequestration sites. The NRAP tool suite includes the Aquifer Impact Model (AIM), which evaluates the potential for groundwater impacts from leaks of CO 2 and brine through abandoned wellbores. There are two aquifer reduced-order models (ROMs) included with the AIM tool, a confined alluvium aquifer, and an unconfined carbonate aquifer. The models accept aquifer parameters as a range of variable inputs so they may have broad applicability. The generic aquifer models may be used at the early stages of site selection, when site-specific data is not available. Guidelines have been developed for determining when the generic ROMs might be applicable to a new site. This work considers the application of the AIM to predicting the impact of CO 2 or brine leakage were it to occur at the Illinois Basin Decatur Project (IBDP). Results of the model sensitivity analysis can help guide characterization efforts; the hydraulic parameters and leakage source term magnitude are more sensitive than clay fraction or cation exchange capacity. Sand permeability was the only hydraulic parameter measured at the IBDP site. More information on the other hydraulic parameters could reduce uncertainty in risk estimates. Some non-adjustable parameters are significantly different for the ROM than for the observations at the IBDP site. The generic ROMs could be made more useful to a wider range of sites if the initial conditions and no-impact threshold values were adjustable parameters.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Phase stability and property evolution of biphasic Ti-Ni-Sn alloys for use in thermoelectric applications

Thermoelectric properties and phase evolution have been studied in biphasic Ti–Ni–Sn materials containing full-Heusler TiNi 2 Sn embedded within half-Heusler thermoelectric TiNiSn. Materials, prepared by levitation induction melting followed by annealing, were of the nominal starting composition of TiNi 1+x Sn, with x between 0.00 and 0.25. Phases and microstructure were determined using synchrotron X-ray diffraction and optical and electron microscopy. The full-Heusler phase is observed to be semi-coherent with the half-Heusler majority phase. Differential thermal analysis was performed to determine melting temperatures of the end-member compounds. The thermal conductivity is reduced with the introduction of a dispersed, full-Heusler phase within the half-Heusler material. This leads to an increased thermoelectric figure of merit, ZT, from 0.35 for the stoichiometric compound to 0.44 for TiNi 1.15 Sn. Beyond x = 0.15 ZT decreases due to a rise in thermal conductivity. Density functional theory calculations using hybrid functionals were performed to determine band alignments between the half- and full-Heusler compounds, as well as comparative energies of formation. The hybrid functional band structure of TiNiSn is presented as well.

Douglas, Jason E.↗

Global‐view coefficients: a data management solution for parallel quantum Monte Carlo applications

Summary Quantum Monte Carlo (QMC) applications perform simulation with respect to an initial state of the quantum mechanical system, which is often captured by using a cubic B‐spline basis. This representation is stored as a read‐only table of coefficients and accesses to the table are generated at random as part of the Monte Carlo simulation. Current QMC applications, such as QWalk and QMCPACK, replicate this table at every process or node, which limits scalability because increasing the number of processors does not enable larger systems to be run. We present a partitioned global address space approach to transparently managing this data using Global Arrays in a manner that allows the memory of multiple nodes to be aggregated. We develop an automated data management system that significantly reduces communication overheads, enabling new capabilities for QMC codes. Experimental results with QWalk and QMCPACK demonstrate the effectiveness of the data management system. Copyright © 2016 John Wiley & Sons, Ltd.

Niu, Qingpeng↗

Reasons for Declining Applicant Numbers in Radiation Oncology From the Applicants' Perspective: Results From the Applicant Concerns and Radiation Oncology Sources Survey (ACROSS)

Applications to radiation oncology in the United States have decreased the past 3 years, resulting in unfilled residency positions (30 [14.5%] in 2019 and 35 [18.5%] in 2020). The aim of this study is to understand the concerns among radiation oncology applicants and whether these concerns may have led to a decline in applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nb3Sn Coating of Twin Axis Cavity for SRF Applications

The twin axis cavity with two identical accelerating beams has been proposed for Energy recovery linac (ERL) applications. Nb3Sn is a superconducting material with a higher critical temperature and a higher critical field as compared to Nb, which promises a lower operating cost due to higher quality factors. Two niobium twin axis cavities fabricated at JLab and were proposed to be coated with Nb3Sn. Due to their more complex geometry, the typical coating process used for basic elliptical cavities needs to be improved to coat these cavities. This devel-opment advances the current coating system at JLab for coating complex cavities. Two twin axis cavities were coated recently for the first time. This contribution dis-cusses initial results from coating of twin axis cavities, RF testing and witness sample analysis with an overview of the current challenges towards high performance Nb3Sn coated twin axis cavities.

Tiskumara, J.↗

A Tunable Bimetallic MOF-74 for Adsorption Chiller Applications: A Tunable Bimetallic MOF-74 for Adsorption Chiller Applications

A mixed metal strategy, in which two different metal nodes coexist in one MOF framework, was examined using MOF-74. The Ni salt precursor for the MOF-74(Ni) analogue was partially replaced during synthesis with relatively inexpensive Zn salt. These bimetallic MOFs were developed and examined for water sorption for potential use in adsorption cooling/chiller applications. Varying concentration ratios of Ni:Zn in MOF-74 achieved using this mixed metal strategy were shown to provide unique impacts on H2O uptake while significantly mitigating the costs of synthesis

Liu, Jian↗

Recent applications of hard x-ray photoelectron spectroscopy

Recent applications of hard x-ray photoelectron spectroscopy (HAXPES) demonstrate its many capabilities in addition to several of its limitations. Examples are given, including measurement of buried interfaces and materials under in situ or in operando conditions, as well as measurements under x-ray standing-wave and resonant excitation. Physical considerations that differentiate HAXPES from photoemission measurements utilizing soft x-ray and ultraviolet photon sources are also presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source

Purpose: Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with specialized conical applicators placed directly on the lesion. Applicators are available for use with high dose rate (HDR){sup 192}Ir sources, as well as electronic brachytherapy sources. Part I of this paper will discuss the applicators used with electronic brachytherapy sources; Part II will discuss those used with HDR {sup 192}Ir sources. Although the use of these applicators has gained in popularity, the dosimetric characteristics including depth dose and surface dose distributions have not been independently verified. Additionally, there is no recognized method of output verification for quality assurance procedures with applicators like these. Existing dosimetry protocols available from the AAPM bookend the cross-over characteristics of a traditional brachytherapy source (as described by Task Group 43) being implemented as a low-energy superficial x-ray beam (as described by Task Group 61) as observed with the surface applicators of interest. Methods: This work aims to create a cohesive method of output verification that can be used to determine the dose at the treatment surface as part of a quality assurance/commissioning process for surface applicators used with HDR electronic brachytherapy sources (Part I) and{sup 192}Ir sources (Part II). Air-kerma rate measurements for the electronic brachytherapy sources were completed with an Attix Free-Air Chamber, as well as several models of small-volume ionization chambers to obtain an air-kerma rate at the treatment surface for each applicator. Correction factors were calculated using MCNP5 and EGSnrc Monte Carlo codes in order to determine an applicator-specific absorbed dose to water at the treatment surface from the measured air-kerma rate. Additionally, relative dose measurements of the surface dose distributions and characteristic depth dose curves were completed in-phantom. Results: Theoretical dose distributions and depth dose curves were generated for each applicator and agreed well with the measured values. A method of output verification was created that allows users to determine the applicator-specific dose to water at the treatment surface based on a measured air-kerma rate. Conclusions: The novel output verification methods described in this work will reduce uncertainties in dose delivery for treatments with these kinds of surface applicators, ultimately improving patient care.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part II. High dose rate {sup 192}Ir sources

Purpose: Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with specialized conical applicators placed directly on the lesion. Applicators are available for use with high dose rate (HDR){sup 192}Ir sources, as well as electronic brachytherapy sources. Part I of this paper discussed the applicators used with electronic brachytherapy sources. Part II will discuss those used with HDR {sup 192}Ir sources. Although the use of these applicators has gained in popularity, the dosimetric characteristics have not been independently verified. Additionally, there is no recognized method of output verification for quality assurance procedures with applicators like these. Methods: This work aims to create a cohesive method of output verification that can be used to determine the dose at the treatment surface as part of a quality assurance/commissioning process for surface applicators used with HDR electronic brachytherapy sources (Part I) and{sup 192}Ir sources (Part II). Air-kerma rate measurements for the {sup 192}Ir sources were completed with several models of small-volume ionization chambers to obtain an air-kerma rate at the treatment surface for each applicator. Correction factors were calculated using MCNP5 and EGSnrc Monte Carlo codes in order to determine an applicator-specific absorbed dose to water at the treatment surface from the measured air-kerma rate. Additionally, relative dose measurements of the surface dose distributions and characteristic depth dose curves were completed in-phantom. Results: Theoretical dose distributions and depth dose curves were generated for each applicator and agreed well with the measured values. A method of output verification was created that allows users to determine the applicator-specific dose to water at the treatment surface based on a measured air-kerma rate. Conclusions: The novel output verification methods described in this work will reduce uncertainties in dose delivery for treatments with these kinds of surface applicators, ultimately improving patient care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A real-time applicator position monitoring system for gynecologic intracavitary brachytherapy

Purpose: To develop a real-time applicator position monitoring system (RAPS) for intracavitary brachytherapy using an infrared camera and reflective markers. Methods: 3D image-guided brachytherapy requires high accuracy of applicator localization; however, applicator displacement can happen during patient transfer for imaging and treatment delivery. No continuous applicator position monitoring system is currently available. The RAPS system was developed for real-time applicator position monitoring without additional radiation dose to patients. It includes an infrared camera, reflective markers, an infrared illuminator, and image processing software. After reflective markers are firmly attached to the applicator and the patient body, applicator displacement can be measured by computing the relative change in distance between the markers. The reflective markers are magnetic resonance imaging (MRI) compatible, which is suitable for MRI-guided HDR brachytherapy paradigm. In our prototype, a Microsoft Kinect sensor with a resolution of 640 by 480 pixels is used as an infrared camera. A phantom study was carried out to compare RAPS' measurements with known displacements ranging from −15 to +15 mm. A reproducibility test was also conducted. Results: The RAPS can achieve 4 frames/s using a laptop with Intel{sup ®} Core™2 Duo processor. When the pixel size is 0.95 mm, the difference between RAPS' measurements and known shift values varied from 0 to 0.8 mm with the mean value of 0.1 mm and a standard deviation of 0.44 mm. The system reproducibility was within 0.6 mm after ten reposition trials. Conclusions: This work demonstrates the feasibility of a real-time infrared camera based gynecologic intracavitary brachytherapy applicator monitoring system. Less than 1 mm accuracy is achieved when using an off-the-shelf infrared camera.

62 RADIOLOGY AND NUCLEAR MEDICINE↗