Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Annulus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Flow regimes in a shallow rotating cylindrical annulus with temperature gradients imposed on the horizontal boundaries

Experimental flow regime diagrams are determined for a new rotating cylindrical annulus configuration which permits a measure of control over the internal vertical temperature gradient. The new annulus has radial temperature gradients imposed on plane horizontal thermally conducting endwalls (with the cylindrical sidewalls as insulators) and is considered to be more relevant to atmospheric dynamics studies than the classical cylindrical annulus. Observations have revealed that, in addition to the axisymmetric flow and nonaxisymmetric baroclinic wave flow which occur in the classical annulus, two additional nonaxisymmetric flow types occur in the new annulus: boundary-layer thermal convection and deep thermal convection. Flow regime diagrams for three different values of the imposed vertical temperature difference are presented, and explanations for the flow transitions are offered. The new annulus provides scientific backup for the proposed Atmospheric General Circulation Experiment for Spacelab. The apparatus diagram is included.

Hathaway, D. H.

Axial-slot Air Admission for Controlling Performance of a One-quarter-annulus Turbojet Combustor and Comparison with Complete Engine

An investigation of a single-annulus turbojet combustor with slot-type air admission was conducted to demonstrate the application of certain design principles to the control of outlet-gas temperature distributions. Comparisons of performance of a one-quarter-annulus combustor (duct-type installation) and a full-annulus combustor (obtained in a full-scale turbojet engine) are presented to indicate the applicability of results obtained from combustion studies conducted in duct-type installations. A reasonable correlation existed between the performance of the one-quarter-annulus and full-annulus combustors except for temperature distribution. Sufficient trends did exist which made it possible to predict temperature distributions for the engine, although absolute correlation did not exist. A radial temperature distribution similar to that required for a given engine was obtained using a one-quarter-annulus duct-type setup to predict results.

COMBUSTION--TURBINE ENGINES

The Dark Annulus of a Drop in a Hele-Shaw Cell Is Caused by the Refraction of Light through Its Meniscus

Knowing the meniscus shape of confined drops is important for understanding how they make first contact and then coalesce. When imaged from the top view by brightfield microscopy, a liquid drop (e.g., corn syrup) confined in a Hele-Shaw cell, surrounded by immiscible liquid (e.g., mineral oil), had a dark annulus, and the width of the annulus decreased with increasing concentration of corn syrup. Since the difference in the annulus width was presumed to be related to the meniscus shape of the drops, three-dimensional images of the drops with different concentrations were obtained using confocal fluorescence microscopy, and their cross-sectional meniscus profile was determined by image processing. The meniscus of the drops remained circular despite varying concentration. Since the refractive index of corn syrup increased with concentration, while the surface tension coefficient between corn syrup and mineral oil remained unchanged, the observed change in the annulus width was then attributed to the refraction of light passing through the drop’s meniscus. As such, a ray optics model was developed, which predicted that the annulus width of the drop would decrease as the refractive index of the drop approached that of the surrounding liquid. Therefore, the dark annulus of the drops in the Hele-Shaw cell was caused by the refraction of light passing through the circular meniscus of the drop.

Sangjin Ryu

Characteristics of mean velocity in the annulus wall region at the exit of turbomachinery rotor passage

This paper reports the experimental study of the three-dimensional characteristics of the mean velocity in the annulus-wall boundary layer and wake mixing region of a moderately loaded compressor rotor blade. The measurements reported were obtained using a three-sensor hot-wire probe at the exit of the rotor. They consisted of tangential surveys at several axial and radial locations downstream of the compressor rotor blade passage. The variation of the streamwise, normal, and radial velocity profiles and their decay characteristics are derived from this data. The measurements reveal the highly complex and three-dimensional nature of the annulus-wall flow field and the nature of the interaction of the annulus-wall boundary layer, the blade boundary layers and wake, and the secondary flow associated with the annulus-wall region.

Davino, R.

Turbulence characteristics in the annulus-wall boundary layer and wake mixing region of a compressor rotor exit

The flow at the exit of a turbomachinery rotor near the annulus wall is three-dimensional with a varying degree of turbulence and nonisotropic characteristics. The characteristics of the turbulence vary considerably with radial and axial location, blade loading, Reynolds number, free-stream turbulence, and the rotor blade geometry. This paper is concerned with the turbulence properties near the annulus wall region of a moderately loaded compressor blade. The variation of the streamwise, normal, and radial intensities as well as the stresses across the wake, its profile and decay characteristics, were determined with a tri-axial hot-wire probe in the stationary frame of reference. The turbulence characteristics in the annulus-wall region of the rotor exit were found to be highly complex due to the interaction of the blade wake and the annulus wall.

Davino, R.

Analysis of shape and motion of the mitral annulus in subjects with and without cardiomyopathy by echocardiographic 3-dimensional reconstruction

The shape and dynamics of the mitral annulus of 10 patients without heart disease (controls), 3 patients with dilated cardiomyopathy, and 5 patients with hypertrophic obstructive cardiomyopathy and normal systolic function were analyzed by transesophageal echocardiography and 3-dimensional reconstruction. Mitral annular orifice area, apico-basal motion of the annulus, and nonplanarity were calculated over time. Annular area was largest in end diastole and smallest in end systole. Mean areas were 11.8 +/- 2.5 cm(2) (controls), 15.2 +/- 4.2 cm(2) (dilated cardiomyopathy), and 10.2 +/- 2.4 cm(2) (hypertrophic cardiomyopathy) (P = not significant). After correction for body surface, annuli from patients with normal left ventricular function were smaller than annuli from patients with dilated cardiomyopathy (5.9 +/- 1.2 cm(2)/m(2) vs 7.7 +/- 1.0 cm(2)/m(2); P <.02). The change in area during the cardiac cycle showed significant differences: 23.8% +/- 5.1% (controls), 13.2% +/- 2.3% (dilated cardiomyopathy), and 32.4% +/- 7.6% (hypertrophic cardiomyopathy) (P <.001). Apico-basal motion was highest in controls, followed by those with hypertrophic obstructive and dilated cardiomyopathy (1.0 +/- 0.3 cm, 0.8 +/- 0.2 cm, 0.3 +/- 0.2 cm, respectively; P <.01). Visual inspection and Fourier analysis showed a consistent pattern of anteroseptal and posterolateral elevations of the annulus toward the left atrium. In conclusion, although area changes and apico-basal motion of the mitral annulus strongly depend on left ventricular systolic function, nonplanarity is a structural feature preserved throughout the cardiac cycle in all three groups.

Non-NASA Center

Noise suppression due to annulus shaping of an inverted-velocity-profile coaxial nozzle

An inverted velocity profile coaxial nozzle for use with supersonic cruise aircraft produces less jet noise than an equivalent conical nozzle. Furthermore, decreasing the annulus height (increasing radius ratio with constant flow) results in further noise reduction benefits. The annulus shape (height) was varied by an eccentric mounting of the annular nozzle with respect to a conical core nozzle. Acoustic measurements were made in the flyover plane below the narrowest portion of the annulus and at 90 deg and 180 deg from this point. The model-scale spectra are scaled up to engine size (1.07 m diameter) and the perceived noise levels for the eccentric and baseline concentric inverted velocity profile coaxial nozzles are compared over a range of operating conditions. The implications of the acoustic benefits derived with the eccentric nozzle to practical applications are discussed.

Goodykoontz, J.

Noise suppression due to annulus shaping of conventional coaxial nozzle

A method which shows that increasing the annulus width of a conventional coaxial nozzle with constant bypass velocity will lower the noise level is described. The method entails modifying a concentric coaxial nozzle to provide an eccentric outer stream annulus while maintaining approximately the same through flow as that for the original concentric bypass nozzle. Acoustical tests to determine the noise generating characteristics of the nozzle over a range of flow conditions are described. The tests involved sequentially analyzing the noise signals and digitally recording the 1/3 octave band sound pressure levels. The measurements were made in a plane passing through the minimum and maximum annulus width points, as well as at 90 degrees in this plane, by rotating the outer nozzle about its axis. Representative measured spectral data in the flyover plane for the concentric nozzle obtained at model scale are discussed. Representative spectra for several engine cycles are presented for both the eccentric and concentric nozzles at engine size.

Vonglahn, U.

Noise suppression due to annulus shaping of a conventional coaxial nozzle

Previous studies have shown that increasing the annulus width of a conventional coaxial nozzle with constant bypass velocity will lower the noise level. In the present model-scale study, the annulus was shaped by an eccentric mounting of the annular nozzle with respect to the conical core nozzle. Acoustic measurements were made in the flyover plane below the widest portion of the annulus and at 90 deg and 180 deg from this point. The model-scale spectra are scaled up to engine size (1.07 m diameter) and the perceived noise levels for the eccentric and concentric coaxial nozzles are compared over a limited range of operating conditions. The implications of the acoustic benefits derived from the eccentric nozzle to practical applications are discussed.

Von Glahn, U.

Noise suppression due to annulus shaping of an inverted-velocity-profile coaxial nozzle

Previous studies have shown that an inverted-velocity-profile coaxial nozzle for use with supersonic cruise aircraft produces less jet noise than an equivalent conical nozzle. Furthermore, decreasing the annulus height (increasing radius ratio with constant flow) results in further noise reduction benefits. In the present model-scale study, the annulus shape, that is, height, was varied by an eccentric mounting of the annular nozzle with respect to a conical core nozzle. Acoustic measurements were made in the flyover plane below the narrowest portion of the annulus and at 90 deg and 180 deg from this point. The model-scale spectra are scaled up to engine size (1.07 m diameter) and the perceived noise levels for the eccentric and baseline concentric inverted-velocity-profile coaxial nozzles are compared over a range of operating conditions. The implications of the acoustic benefits derived with the eccentric nozzle to practical applications are discussed.

Goodykoontz, J.

Three dimensional mean velocity and turbulence characteristics in the annulus wall region of an axial flow compressor rotor passage

The experiment was performed using the rotating hot-wire technique within the rotor blade passage and the stationary hot-wire technique for the exitflow of the rotor blade passage. The measurements reveal the effect of rotation and subsequent flow interactions upon the rotor blade flowfield and wake development in the annulus-wall region. The flow near the rotor blade tips is found to be highly complex due to the interaction of the annulus-wall boundary layer, the blade boundary layers, the tip leakage flow, and the secondary flow. Within the blade passage, this interaction results in an appreciable radial inward flow as well as a defect in the mainstream velocity near the mid-passage. Turbulence levels within this region are very high. This indicates a considerable extent of flow mixing due to the viscous flow interactions. The size and strength of this loss core is found to grow with axial distance from the blade trailing edge. The nature of the rotor blade exit-flow was dominated by the wake development.

Davino, R.

Characteristics of the flow in the annulus-wall region of an axial-flow compressor rotor blade passage

Three-dimensional characteristics of the mean velocity and turbulence structure in the annulus-wall region of a moderately loaded compressor rotor have been investigated experimentally by employing triaxial hot-wire probes. Results are presented which indicate that the flow within and downstream of the rotor passage is highly complex due to the interaction of the annulus-wall boundary layer, blade boundary layers, tip leakage flow, and passage secondary flow. An understanding of the reported viscous flow interactions is important for establishing improved aerodynamic design criteria and efficiency, for predicting noise levels, and for determining the stall, surge, vibration, and flutter characteristics of turbomachinery.

Davino, R. M.

Stability of fluid flow in a cylindrical annulus

Helical flow in an annulus between two coaxial cylinders is investigated with regard to its stability against the formation of helical vortices of the type known as Taylor's annular vortices. Assuming the annulus to be small and the velocities to vary linearly with radius, it is shown that the problem can be reduced to the classical case of flow between two rotating cylinders. An appropriate stability criterion for helical flows is derived from Rayleigh's stability criterion applicable to such flows.

Ludwieg, H.

Laboratory experiments in a baroclinic annulus with heating and cooling on the horizontal boundaries

Experiments have been performed in a cylindrical annulus with horizontal temperature gradients imposed upon the horizontal boundaries and in which the vertical depth was smaller than the width of the annulus. Qualitative observations were made by the use of small, suspended, reflective flakes in the liquid (water). Four basic regimes of flow were observed: (1) axisymmetric flow, (2) deep cellular convection, (3) boundary layer convective rolls, and (4) baroclinic waves. In some cases there was a mix of baroclinic and convective instabilities present. As a 'mean' interior Richardson number was decreased from a value greater than unity to one less than zero, axisymmetric baroclinic instability of the Solberg type was never observed. Rather, the transition was from non-axisymmetric baroclinic waves, to a mix of baroclinic and convective instability, to irregular cellular convection.

Miller, T. L.

Laser Doppler velocimeter measurement of annulus wall boundary layer development in a compressor rotor

Detailed measurement of the flow field in the tip region of a compressor rotor was carried out using LDV. The axial and tangential components of relative velocities were measured upstream, inside the passage, and at the exit of the rotor, up to about 20 percent of the blade span from the blade tip. The annulus-wall boundary layer is well behaved at the leading edge and far downstream of the rotor. But inside the passage, complex interactions between the leakage flow and the annulus-wall boundary layer result in unconventional profiles with wide deviations from models employed for analyses.

Lakshminarayana, B.

A study of baroclinic instability in a cylindrical annulus with the temperature gradient imposed on the lower surface

Results are presented from experimental and numerical-modeling studies carried out on a rotating thermally driven fluid system in a cylindrical annulus with the horizontal gradient imposed upon the lower horizontal surface. The rotation rate and the temperature difference were varied to construct a regime diagram in thermal Rossby-number/Taylor-number space. It is shown that the curve separating the axisymmetric flow from the wave flow is 'knee-shaped', similar to the conventional side-heated and side-cooled baroclinic annulus. The experimentally observed transition curve agrees well with numerical calculations and the agreement between the predicted and measured wavenumbers is good both near the transition and within the wave regime. Away from the transition curve and well within the wave regime, there is an evolution from larger to smaller wavenumbers as the flow equilibrates, which is well captured by the numerical model for these cases.

Miller, Timothy L.

Pressure oscillation in the leakage annulus between a shrouded impeller and its housing due to impeller-discharge-pressure disturbances

The perturbed flow in the leakage path between a shrouded-pump impeller and its housing is analyzed using experiences with the Space Shuttle Main Engine (SSME), high pressure fuel turbopump (HPFTP) wearing-ring seals. Analysis is based on a bulk-flow model which consists of the path-momentum, circumferential momentum, and continuity equations. The pressure oscillations in the leakage annulus are driven by a circumferential variation of the impeller discharge pressure. It is shown that the occurrence and nature of the pressure oscillations depend on the tangential-velocity ratio of the fluid entering the seal, the order of the Fourier coefficient, the closeness of the precessional frequency of the rotating pressure field to the first natural frequency of the fluid annulus, and the clearance of the wearing-ring seal. The results obtained may explain the internal melting observed on SSME HPFTP seal parts.

Childs, D. W.

Theoretical analysis of total-pressure loss and airflow distribution for tubular turbojet combustors with constant annulus and liner cross-sectional areas

Compressible and incompressible flow calculations were made of the combustor total-pressure-loss coefficient and liner airflow distribution for tubular turbojet combustors having constant annulus and liner cross-sectional areas along the combustor axis. Information on static and total pressure distribution and liner air-jet entrance angles along the length of the combustor was obtained as an intermediate step in the calculations. The calculations include the effects of heat release, annulus wall friction, and variation in discharge coefficients of the liner wall openings along the combustor. The combustor total-pressure-loss coefficient and liner air-flow distribution are presented graphically in terms of the following dimensionless parameters: (1) combustor reference Mach number, (2) ratio of combustor-exit to inlet total temperature, (3) fraction of total airflow passing through the liner dome, (4) ratio of total open hole area in liner wall to total combustor cross-sectional area, and (5) ratio of liner cross-sectional area to total combustor cross-sectional area.

Graves, Charles C