Characterization of catalytic fast pyrolysis oils: The importance of solvent selection for analytical method development
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Boron is a ubiquitous dissolved constituent in natural waters due to its high solubility, natural occurrence in continental crust, and anthropogenic use in fertilizers, consumer products, and other non-natural sources. The two stable isotopes of boron, 10 B and 11 B (natural abundances ≈ 19.9 and ≈ 80.1 atom percent, respectively), undergo isotopic fractionation due to a variety of chemical processes related to boron speciation ( 10 B is preferentially incorporated into B(OH) 4 - versus B(OH) 3 , e.g. Byrne et al., 2006). The isotopic composition of dissolved boron in groundwater can be used to determine the source(s) of boron; this information can be used to infer the source(s) of other co-migrating contaminants (e.g. nitrate, pharmaceuticals, etc.). Boron behaves as a conservative element in groundwater and surface water systems (Barth, 2000), and the isotopic signature of boron is most useful in conjunction with other stable and radiogenic isotope systems (e.g. δ 18 O, δ 15 N, δ 13 C, 87 Sr/ 86 Sr; Tirez et al., 2010; Widory et al., 2004; Widory et al., 2005) to determine the source(s) of contaminants of interest. We present here a method for boron purification in natural water samples (groundwater, surface water, and seawater) by ion exchange chemistry and measurement of boron isotopic composition by MC-ICP-MS. These methods can be applied to samples with boron concentrations as low as 10 ppb with precision on δ 11 B measurements better than ± 1 ‰. We utilize boron isotopic measurements of boric acid, groundwater, and seawater standards to validate the methods. We also present boron isotopic measurements of San Diego County domestic well samples to demonstrate how these methods can be applied to any study of natural water samples.
In the polymer bonded explosive (PBX) 9501, a binder consisting of 2.5 wt% nitroplasticizer (NP) and 2.5 wt% Estane R 5703 (Estane) is combined with 94.9 wt% of the high-explosive HMX and 0.1 wt% stabilizer. Because of its flexibility and tensile strength, this binder lowers the sensitivity and improves the manufacturability of PBX 9501. However, like many plasticizers comprised of low molecular weight components, NP has a tendency to diffuse out of the PBX 9501 matrix and can decompose at moderate temperatures into reactive byproducts, such as NO, NO 2 , H 2 O, and HNO x . Through oxidation and hydrolysis, these molecules can further degrade NP and Estane, ultimately degrading the properties of PBX 9501. While gaseous molecules can readily diffuse out of the PBX 9501 charges, the intermediates with lower volatility are more likely trapped in the condensed phase inside the charges and, in a closed system, will co-exist with Estane for an extended period of time creating an ongoing reactive environment. Understanding the rates of formation for these volatiles and intermediates during the NP degradation is therefore a critical prerequisite for understanding the long-term stability of polymeric binders used in munition systems. To work toward this ultimate goal, in the past year, we have conducted comprehensive studies on the physical properties of NP and finished three-year long aging experiment to understand the aging behavior of NP under thermal treatment. Important results are summarized in this annual report. Although NP is widely used in the DOE complex, their physical properties are rather scattered and inconsistent in the open literature. For example, there are at least two widely different values, 14.5°C and -15°C, for the melting point of NP. Although it is known that NP is a eutectic 50:50 mixture of BDNPA and BDNPF, their eutectic phase diagram is not well documented. Furthermore, the effect of temperature on the miscibility between water and eutectic BDNPA/F mixture is rarely reported. To fill these knowledge gaps, a large set of BDNPA/F mixtures with BDNPA concentration ranging from 0 to 100 wt% was analyzed using DSC techniques. In addition to determining the eutectic melt point as -25°C, a phase diagram of the BDNPA/F system was constructed from -30°C to 45°C. With this phase diagram, the phase transition temperatures and composition can be readily found for the BDNPA/F mixtures with various mass ratios.
In this study, we investigated several porous chromatographic materials as synthetic substrates for preparing surrogate nuclear explosion debris particles. The resulting synthetic debris materials are of interest for use in developing analytical methods. Eighteen metals, including some of forensic interest, were loaded onto materials by immersing them in metal solutions (556 mg/L of each metal) to fill the pores, applying gentle heat (110°C) to drive off water, and then treating them at high temperatures (up to 800°C) in air to form less soluble metal species. High-boiling-point metals were uniformly loaded on spherical controlled-pore glass to emulate early fallout, whereas low-boiling-point metals were loaded on core-shell silica to represent coated particles formed later in the nuclear fallout-formation process. Analytical studies were applied to characterize solubility, material balance, and formation of recalcitrant species. Dissolution experiments indicated loading was 1.5 to 3 times higher than expected from the pore volume alone, a result attributed to surface coating. Analysis of load solutions before and after filling the material pores revealed that most metals were passively loaded; that is, solutions filled the pores without active metal discrimination. However, niobium and tin concentrations were lower in solutions after pore filling, and were found in elevated concentrations in the final products, indicating some metals were selectively loaded. High-temperature treatments caused reduced solubility of several metal species, and loss of some metals (rhenium and tellurium) because volatile species were formed. Sample preparation reproducibility was high (the inter-batch relative standard deviation was 7.8%, and the intra-batch relative standard deviation was 0.84%) indicating that this material is suitable for use as a working standard for analytical methods development. We anticipate future standardized radionuclide-loaded materials will find use in radioanalytical methods development and/or serve as a starting material for the synthesis of more complex forms of nuclear explosion debris (e.g., Trinitite).
The purpose of this project is to develop analytical methods that can be deployed for analysis of lithium isotope enrichment products. One method involves rapid, high-throughput, relatively low precision analysis for direct monitoring of enrichment processes. A second method involves slower, but more precise analysis of final products of the enrichment process. We will use commercially available analytical equipment (quadrupole base inductively coupled plasma mass spectrometry and multi-collector magnetic sector inductively coupled plasma mass spectrometry) so that the analytical methods developed can be applied broadly.
The Savannah River National Laboratory Nuclear Measurements Group was tasked by the Mark 18A Program team with developing three analytical characterization methods. These methods will support process and waste characterization of the Mark 18A program material. While methods already existed for most analytes of interest to the Mark 18A program team, the Nuclear Measurements Group developed and refined methods to quantify the Cf isotopes, 107 Pd, and 121m Sn. The results of that effort are presented in this work. Methods were successfully developed to characterize the Mark 18A samples for the needed isotopes and the NMG is ready to receive Mark 18A program samples.
Mercury in the Savannah River Site (SRS) Liquid Waste System (LWS) exists in various forms, including: a) ionic inorganic mercury, organomercury (e.g., methyl Hg), and other less abundant species dissolved in LWS fluids, b) mercury solids such as oxides, hydroxides, amalgams, sulfides, and sorbed mercury, c) accumulations of dense liquid elemental mercury, and d) vapor phase elemental and organomercury mercury in tank headspace gas and in evaporators. Strategic and proactive management of the estimated 60,000 Kg mercury in the LWS requires deployment of efficient and effective paradigms for sampling and analysis of the total quantity of mercury in the various physical-chemical forms. Scoping tests of selective gas-phase sorbents for mercury speciation were performed to support LWS objectives. This research specifically focused on developing and testing streamlined methods to obtain high-quality analytical results for gaseous mercury species. The proposed methods are straightforward, using small columns (microcolumns) filled with materials that selectively sorb one or more target forms of mercury. Simple differentiation of mercury species and quantification is then achieved using an efficient thermal-desorption-based total mercury analyzer as the final step. Benefits associated with transitioning from multistep procedures such as EPA Methods 245.1, 1630 and 1631to streamlined microcolumn approaches include reduced analysis time, labor, and waste generation. Such transitioning would maximize the value of the current deployment of direct mercury analysis (EPA Method 7473) at SRS. This work has two target end uses: 1) simplifying the analysis steps and reducing costs for liquid samples (e.g., developing a total organic mercury (TOM) method), and 2) providing options for high-quality onsite analysis and rapid turnaround for gas samples in support of SRS LWS industrial hygiene (IH) objectives.
This project will develop methodology to identify and analyze U and Pu containing particles using laser ablation MC-ICP-MS. The proposed work will involve: i) setup and optimization of the LA-MC-ICP-MS system, ii) testing and validation by analysis of QC standards, iii) designing analytical protocols for single particles, and iv) developing a data processing system. Ultimately, this project will output a detailed operating procedure documenting the experimental techniques and data processing routines required to perform particle identification and analysis by laser ablation MC-ICP-MS.
Savannah River National Laboratory (SRNL) was tasked with identifying and developing at least one, but preferably two methods for quantifying the suppressor in the Next Generation Solvent (NGS) system. The suppressor is a guanidine derivative, N,N',N"-tris(3,7-dimethyloctyl)guanidine (TiDG). A list of 10 possible methods was generated, and screening experiments were performed for 8 of the 10 methods. After completion of the screening experiments, the non-aqueous acid-base titration was determined to be the most promising, and was selected for further development as the primary method. 1 H NMR also showed promising results from the screening experiments, and this method was selected for further development as the secondary method. Other methods, including 36 Cl radiocounting and ion chromatography, also showed promise; however, due to the similarity to the primary method (titration) and the inability to differentiate between TiDG and TOA (tri-n-ocytlamine) in the blended solvent, 1 H NMR was selected over these methods. Analysis of radioactive samples obtained from real waste ESS (extraction, scrub, strip) testing using the titration method showed good results. Based on these results, the titration method was selected as the method of choice for TiDG measurement. 1 H NMR has been selected as the secondary (back-up) method, and additional work is planned to further develop this method and to verify the method using radioactive samples. Procedures for analyzing radioactive samples of both pure NGS and blended solvent were developed and issued for the both methods.
Here, the United Nations Economic Commission for Europe Global Technical Regulation (GTR) Number 13 ( Global Technical Regulation on Hydrogen and Fuel Cell Vehicles ) is the defining document regulating safety requirements in hydrogen vehicles, and in particular, fuel cell electric vehicles (FCEVs). GTR Number 13 has been formally adopted and will serve as the basis for the national regulatory standards for FCEV safety in North America (led by the United States), Japan, Korea, and the European Union. The GTR defines safety requirements for these vehicles, including specifications on the allowable hydrogen levels in vehicle enclosures during in-use and post-crash conditions and on the allowable hydrogen emissions levels in vehicle exhaust during certain modes of normal operation. However, in order to be incorporated into national regulations, that is, to be legally binding, methods to verify compliance with the specific requirements must exist. In a collaborative program, the Sensor Laboratories at the National Renewable Energy Laboratory in the United States and the Joint Research Centre, Institute for Energy and Transport in the Netherlands have been evaluating and developing analytical methods that can be used to verify compliance with the hydrogen release requirements as specified in the GTR.
This is a technical report to be published as part of the FY2021 annual overview package. We have designed experiments and developed analytical methods using images from x-ray and electron microscopy in order to quantify the behavior of crystal dislocation defects at their native nanometer-length and micro-length scales. The results of these analyses are used to directly inform theoretical physics models and guide interpretation of dark field x-ray microscopy (DFXM) images that offer spatial resolution surpassing the resolution of beamline optics. Additionally, we developed new analytical methods to automate the alignment of optics hardware used in both synchrotron and x-ray free electron laser beamline facilities. The tools and workflows developed for this project are now being deployed as proof-of-concept in reaction history analysis (RHA) for future programmatic integration.
High Efficiency Particulate Air (HEPA) filters, commonly used in nuclear filtration applications, are an integral part of the waste management processes in nuclear plants. HEPA filters are 99.97% efficient filtration devices characterized by their high resistance to air flow, or pressure drop. From theoretical models, the initial pressure drop across a clean filter is proven to be a function of the filter media fiber diameters and porosity of the media. These filter properties are relatively difficult to obtain with traditional manual methods; therefore, there is a need to develop analytical methods to find the fiber diameter and porosity to determine the pressure drop. Typically, these values can be found by substituting a calculated representative value based upon measured values, such as equivalent fiber diameter based upon a clean pressure drop. However, these values may also be directly recorded and measured by incorporating Scanning Electron Microscope (SEM) image analysis and other measurement methods to analyze the filter media and determine its physical properties without the need for media testing. DiameterJ, an open source Java plug-in, used with ImageJ, can process images of filter media taken by an SEM to find statistical data such as mean fiber diameter and porosity. To produce the raw data, SEM images of two filter media type samples are taken and segmented in DiameterJ using the traditional and statistical region merging segmentation algorithms. Manual segmentation is necessary after the initial segmentation by the algorithms as the images tend to be too complex for the algorithms to output with the necessary accuracy. However, complications exist in the manual segmentation process as these methods can be time intensive and prone to the individual bias of the user. This in turn can skew the final mean fiber diameter result, and lead to either an over or under prediction of the pressure drop. It was also discovered that the porosity data produced by DiameterJ is inaccurate, as the SEM analyzes the three-dimensional filter media by projecting its geometry onto a plane and analyzing it as a two-dimensional binary image. Thus, the porosity is artificially inflated through the segmentation process, rendering this result incorrect. Alternatively, density determination, gravimetric analysis, and thickness testing of the filter media is collectively used to determine the filter fiber porosity. Together, the SEM image analysis and analytical lab methods produce results through direct measurements which allow for the prediction of the initial pressure drop from clean filter media without the need for prior media testing to collect pressure data. By improving upon this proposed analytical method in the future, there is potential to streamline the process of finding these filter properties into a more direct methodology for determining the pressure drop across HEPA filters.
Ion Chromatography (IC) is routinely used at the Savannah River National Laboratory (SRNL) for sample analysis and characterization. Results from IC analysis are valued in corrosion control maintenance and measurement programs, remediation waste process control, soil and ground water measurement, nuclear materials processing, and various other research and development programs. Presented in this report are analytical methods developed on a DIONEX ICS3000 Reagent Free Ion Chromatography (RFIC) system located in AD at SRNL. This IC system contains two independent analysis channels comprising of a mobile phase generator, a pump, stationary phase columns, a suppressor and a conductivity detector. One channel is dedicated to anion analysis using Potassium Hydroxide (KOH) as the mobile phase while a second channel is configured for cation analysis using Methanesulfonic Acid (MSA) as the mobile phase. Both channels share an autosampler and the peak analysis software, Chromeleon{reg_sign} v.6.8. Instrument configuration is modified from the manufacturer for radiological service. Listed within this report are Dionex ICS3000 parameters and results for the analysis of routine anions and cations. Additional method parameters and discussion are presented on the analysis of Acetate (CH{sub 3}COO{sup -}) and Iodate (IO{sub 3}{sup -}). Previous IC analysis instruments at AD have been based upon carbonate/bicarbonate buffer mobile phase chemistry. This report represents a transition to hydroxide as a mobile phase eluent. The hydroxide eluent offers a lower baseline conductivity, which allows for greater sample dilution and/or lower detection limits. Also the hydroxide mobile phase and column set has a significant separation of the phosphate peak from the nitrate and sulfate peaks vs. the carbonate/bicarbonate mobile phase and column set, an advantage for the industrial waste analyzed at SRNL.
This document serves as both an FY2103 End-of-Year and End-of-Project report on efforts that resulted in the design of a prototype fast neutron multiplicity counter leveraged upon the findings of previous project efforts. The prototype design includes 32 liquid scintillator detectors with cubic volumes 7.62 cm in dimension configured into 4 stacked rings of 8 detectors. Detector signal collection for the system is handled with a pair of Struck Innovative Systeme 16-channel digitizers controlled by in-house developed software with built-in multiplicity analysis algorithms. Initial testing and familiarization of the currently obtained prototype components is underway, however full prototype construction is required for further optimization. Monte Carlo models of the prototype system were performed to estimate die-away and efficiency values. Analysis of these models resulted in the development of a software package capable of determining the effects of nearest-neighbor rejection methods for elimination of detector cross talk. A parameter study was performed using previously developed analytical methods for the estimation of assay mass variance for use as a figure-of-merit for system performance. A software package was developed to automate these calculations and ensure accuracy. The results of the parameter study show that the prototype fast neutron multiplicity counter design is very nearly optimized under the restraints of the parameter space.
Nitrous oxide (N 2 O) was used as a reaction gas to investigate the gas phase ion-molecule interactions using the Agilent 8900 QQQ-ICP-MS. A multi-element standard containing 45 elements with masses ranging from 9 to 208 u was measured in the presence and absence of N 2 O. The main product ion species observed were oxides and nitrides. Comparison of the N 2 O reaction results with similar measurements conducted with O 2 revealed that N 2 O was more effective at forming oxides in general: the elements Cd and Pb were shown to produce oxides with N 2 O where the reaction did not occur with O 2 . Nitrous oxide was also shown to produce a significant amount of nitride species in a few cases. The general reactivity was shown to be consistent with density functional theory (DFT)-predicted reaction enthalpies, such that all predicted exothermic reactions produced product ions at levels at least 1% of the unreacted ion. Our results show that reaction enthalpy is a reasonable predictor of reactivity with N2O on the timescales of the interactions in non-thermal ICP-MS/MS systems. Our work demonstrates the utility of two relatively new platforms (commercial elemental ICP-MS/MS and EMSL Arrows interface to the NWChem program suite), which allows for the study of a large number of elements within a short period. While DFT with the basis sets utilized here is not the most accurate computational method, it is also not computationally expensive and is shown to be suitable for predicting gas phase reactivity in the QQQ-ICP-MS for the majority of ions studied. Here, the ease and rapidity of data collection and DFT calculations has the potential to be very impactful for the identification of targeted reaction chemistries to be leveraged for analytical method development, such as for the inline separation of isobaric interferences from analytes of interest.
Carbon dioxide (CO 2 ) was used as a reaction gas to investigate the gas‐phase ion‐molecule interactions using the Agilent 8900 ICP‐MS/MS. A solution containing forty‐five elements representative of the periodic table was used to supply the ions to react with CO 2 in the collision/reaction cell (CRC). The only significant product ions formed were monoxides. The general reactivity was shown to be consistent with density functional theory (DFT)‐predicted reaction enthalpies, such that all predicted exothermic reactions produced product ions at levels of at least 1% of the unreacted ion. Most endothermic reactions observed had sufficient kinetic energy in excess of the reaction enthalpies. Our results suggest that reaction enthalpy is a reasonable predictor of reactivity with CO 2 on the timescales of the interactions in non‐thermal ICP‐MS/MS systems. The ease and rapidity of data collection with the ICP‐MS/MS and DFT calculations using the NWChem suite has value given the scarcity of thermochemical data of CO 2 reactions in the literature. These studies are especially useful for the identification of targeted reaction chemistries to be leveraged for analytical method development, such as for the inline separation of isobaric interferences from analytes of interest.
This work presents a novel automated analytical method developed for high throughput ultrasensitive determinations of Th and U in copper using inductively coupled plasma mass spectrometry (ICP-MS). The method is based on the use of ultra clean sample preparation procedures including the use of a fully automated off-line chromatography system for the extraction and pre-concentration of the analytes prior to ICP-MS analysis. The separation system is equipped with a single reusable chromatographic column that, with the rigorously clean procedures developed herein, provided a low carryover, low background, and reproducible automated separation method. Isotope dilution methods were used for quantitation. Method Detection Limits (MDLs) of 3.7 and 9.4 fg·g-1 were obtained for the quantitation of 232Th and 238U in copper, respectively, corresponding to activities of 0.0148 and 0.116 microBq·kg-1 for 232Th and 238U, respectively. The analytical method provided high and reproducible tracer recoveries. The use of an automated system significantly reduced the extremely tedious active work time required for the chemist (by ca. 80%) relative to manually performing the separation. This method could be adapted to other critical sample matrices requiring the utmost in high throughput clean chemistry procedures for automated ultrasensitive analyses.