Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Analytical Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Determination of Biogenic Content by 14 C in fuels using Liquid Scintillation Analysis Laboratory Analytical Procedure (Laboratory Analytical Procedure)

This procedure covers the determination of the percent 14 C in biogenic gasoline, jet fuel, and diesel range hydrocarbons prepared from distillation of hydrotreated pyrolysis oils and blended with fossil derived hydrocarbons (e.g. fossil diesel, gasoline, jet, or toluene). Either an internal 14C standard or a color quench curve is used to correct for potential signal quenching effects. Recent publications provide some background of direct LSC methods used for determination of biogenic fuel content.

02 PETROLEUM↗

Determination of Total, Organic, and Inorganic Carbon and Total Nitrogen in Biological Cultures and Liquid Fraction Process Samples: Laboratory Analytical Procedure (LAP)

This Laboratory Analytical Procedure (LAP) describes the quantitative determination of total organic carbon, inorganic carbon in whole suspended biological samples and in the cell-free supernatant, by combustion and CO 2 detection with a non-dispersive infrared (NDIR) detector. This allows for distinct reporting of soluble and insoluble organic and inorganic carbon. In addition, this procedure covers the quantitative determination of soluble nitrogen in the cell-free supernatant.

09 BIOMASS FUELS↗

Accelerated Aging of Fast Pyrolysis Bio-Oil Using Carbonyl Titration: Laboratory Analytical Procedure (LAP)

This laboratory analytical procedure covers the accelerated aging of fast pyrolysis bio-oils. Bio-oils undergo reactions that result in physical and chemical changes over time. These changes typically result in an increase in molecular weight, decrease in some functional groups such as carbonyls, and an increase in viscosity; additionally, the aging process often leads to phase separation. Studies have shown that accelerated aging of bio-oils using this method closely mimics room temperature aging for long periods of time (over 3 years). This procedure has been developed for the accelerated aging of fast pyrolysis bio-oils only. Fast pyrolysis bio-oils are more reactive than other bio-oils (e.g., catalytic fast pyrolysis) and undergo aging much more rapidly. Therefore, this procedure should only be used for fast pyrolysis bio-oil samples.

09 BIOMASS FUELS↗

Identification and Quantification of Photosynthetic Pigments in Algae (Laboratory Analytical Procedure (LAP))

The Laboratory Analytical Procedure (LAP) outlined here describes a method to quantitatively extract phytopigments from microalgae biomass, as well as to identify and quantify individual pigments based on separation and detection with a High-Performance Liquid Chromatography (HPLC) system coupled to a Diode Array Detector (DAD). Pigments were extracted with greater than 95 % extraction efficiency. Chromatographic conditions allowed for isomeric resolution between pigments and identification based on UV/Vis spectra and comparison to analytical standards.

09 BIOMASS FUELS↗

Data review processes in the analytical laboratory

These documents contain information on the Analytical laboratory data review processes for the following analytical techniques: - alpha spectrometry - light elements analyses - gamma spectrometry - gas proportional flow counting - HR-ICP-MS - Q-ICP-MS - MC-ICP-MS - ICP OES - liquid scintillation counting

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The role of light microscopy in aerospace analytical laboratories

Light microscopy has greatly reduced analytical flow time and added new dimensions to laboratory capability. Aerospace analytical laboratories are often confronted with problems involving contamination, wear, or material inhomogeneity. The detection of potential problems and the solution of those that develop necessitate the most sensitive and selective applications of sophisticated analytical techniques and instrumentation. This inevitably involves light microscopy. The microscope can characterize and often identify the cause of a problem in 5-15 minutes with confirmatory tests generally less than one hour. Light microscopy has and will make a very significant contribution to the analytical capabilities of aerospace laboratories.

Crutcher, E. R.↗

Automated Data Review of Analytical Laboratory Results at Los Alamos National Laboratory - 20299

Newport News Nuclear BWXT-Los Alamos, LLC (N3B) collects samples in support of the U.S. Department of Energy's (DOE) Office of Environmental Management (EM) Los Alamos Legacy Cleanup Contract (LLCC). N3B receives and reviews over 1.6 million sample data points annually in support of various ongoing environmental monitoring and remediation projects of the LLCC. N3B must demonstrate and document that reported external analytical laboratory data produced for the LLCC are of sufficient quality to fulfill their intended purpose and to support defensible decision making as described in EPA QA/G4 Guidance for the Data Quality Objectives Process 1994. In 2018, N3B assumed management of the LLCC along with the Environmental Information Management (EIM) database that contains all historical and current environmental data associated with the LLCC. The entire EIM database is shared between N3B, Triad National Security, LLC (Triad), and New Mexico Environment Department (NMED). These three parties jointly manage the database, its configuration, and changes / updates. All environmental data that are entered into EIM are updated and available, on a daily basis, in the linked public database Intellus New Mexico (Intellus). The quality and defensibility of the environmental data generated from sampling activities is a key component of an effective remediation process. Providing quality data is accomplished through a data assessment process that includes examination, verification, and validation. Examination is the assessment of completeness of the deliverables, identification of any reporting errors, and determining the usability of the data based on the laboratory's evaluation of its data as described in the case narrative received with the data. Verification consists of an evaluation of the Electronic Data Deliverables (EDD) data report to determine the extent to which the external analytical laboratories met method and contract-specific quality control and reporting requirements. Validation consists of determining the data quality and the extent to which the external analytical laboratories accurately and completely reported all sample and quality control results and satisfied all contract requirements. EIM contains an automatic Data Validation Module which performs automated data review (DVM ADR). DVM ADR is a tool to assist in the validation process. When DVM ADR is used in conjunction with manual examination of sample data packages, the combination of the two will meet and exceed the requirements of verification. N3B recognized an opportunity for process improvement, focusing on DVM ADR configuration and enhancements in EIM. Testing EIM's configuration provided proof of the DVM ADR's capabilities and flexibility to accurately perform routine data checks based on analytical methods and regulatory requirements. In addition, the DVM ADR module was improved through enhancements for all analytes, particularly upgrades for radiochemistry data. Extensive testing of the DVM ADR module occurred using EDDs from actual laboratory analyses on the EIM testing site. During this process, N3B manipulated EDD information to verify that the actual outcomes matched the expected outcomes. The results of this testing were shared with the database architects, and configuration improvements were identified to address these results. During this process, N3B identified that the radiochemical DVM ADR capabilities were underutilized, and so enhanced the DVM ADR functionality with respect to radioanalytical assessment. N3B environmental data uploads to Intellus on a daily basis from EIM, once the analytical data undergoes examination and verification. As such, it is important to have a high level of confidence in the quality and defensibility of the data. The process of manual examination, along with the DVM ADR, in conjunction with full validation of a percentage the data specified through the Data Quality Objectives greatly increases efficiency of data review and confidence level of the quality of the data, and gives the project managers, governmental offices, and the public expedited access to high-quality data. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lessons Learned-Analytical Laboratory Construction Modifications

The purpose of this document is to disseminate lessons learned from the Sandia National Laboratories (SNL) Building 1090 modification project and other analytical laboratory related construction projects. The following sections summarize lessons learned at various phases of the project.

99 GENERAL AND MISCELLANEOUS↗

Automating the Analytical Laboratories Section, Lewis Research Center, National Aeronautics and Space Administration: A feasibility study

The feasibility of computerized automation of the Analytical Laboratories Section at NASA's Lewis Research Center was considered. Since that laboratory's duties are not routine, the automation goals were set with that in mind. Four instruments were selected as the most likely automation candidates: an atomic absorption spectrophotometer, an emission spectrometer, an X-ray fluorescence spectrometer, and an X-ray diffraction unit. Two options for computer automation were described: a time-shared central computer and a system with microcomputers for each instrument connected to a central computer. A third option, presented for future planning, expands the microcomputer version. Costs and benefits for each option were considered. It was concluded that the microcomputer version best fits the goals and duties of the laboratory and that such an automted system is needed to meet the laboratory's future requirements.

Boyle, W. G.↗

Corrosivity Screening of Pyrolysis Bio-Oils by Short-Term Alloy Exposures. Laboratory Analytical Procedure (LAP), Issue Date: May 12, 2022

Bio-oils contain organic acids and oxygenated compounds that can lead to corrosion issues during bio-oil processing and storage. This Laboratory Analytical Procedure (LAP) allows for rapid screening of a bio-oil's corrosivity without the need for complex equipment and long-term exposures. A robust and repeatable method for assessing the corrosivity of bio-oils is necessary in order to remove materials degradation as an obstacle to research, upgrading, use and storage of bio-oils. This LAP involves the incubation of a representative alloy, 410 stainless steel (410 SS), specimen in bio-oil over a period of 48 hours at 50 degrees C in a sealed container. The corrosive species in the bio-oil react with and deplete alloy elements such as iron (Fe) and/or chromium (Cr) from the specimen into the bio-oil solution. The depletion of Fe and Cr from the specimen results in a significant mass loss that can be recorded. The mass loss is directly correlated to the corrosivity of a bio-oil. Examples of bio-oils in scope include the ones produced by fast pyrolysis and catalytic fast pyrolysis, as well as liquids produced from hydrothermal liquefaction.

09 BIOMASS FUELS↗

MIS Shelf-Life Final Report for Plutonium Oxide Item CAN92 (SSR147) from Rocky Flats Analytical Laboratory Operations

A plutonium/uranium oxide material from the Material Identification and Surveillance (MIS) Program inventory has been studied to determine the gas generation and corrosion behavior in a storage environment. Sample CAN92 represents plutonium/uranium oxides stored in 3013 containers. The material originated in the analytical laboratory at Rocky Flats. This study followed over time the gas pressure and composition of a sample with nominally 0.5 wt% water in a sealed container with an internal volume scaled to 1/400th of the volume of a 3013 container. Gas compositions had been measured periodically over 5 ½ years. The maximum observed gas pressure from gas generation was 117 kPa. The increase over the initial pressure of 77.5 kPa was largely due to the generation of nitrogen and carbon dioxide with minor amounts of hydrogen and nitrous oxide. The internal components of SSR147 were inspected 6.5 years after it was removed from the array. The inside surfaces of the inner bucket exposed to the original sample for 1,937 days had an etched appearance and general corrosion. No pitting was observed on the inner bucket that held the sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CheMin: A Definitive Mineralogy Instrument in the Analytical Laboratory of the Mars Science Laboratory (MSL '09)

An important goal of the Mars Science Laboratory (MSL 09) mission is the determination of definitive mineralogy and chemical composition. CheMin is a miniature X-ray diffraction/X-ray fluorescence (XRD/XRF) instrument that has been chosen for the analytical laboratory of MSL. CheMin utilizes a miniature microfocus source cobalt X-ray tube, a transmission sample cell and an energy-discriminating X-ray sensitive CCD to produce simultaneous 2-D X-ray diffraction patterns and X-ray fluorescence spectra from powdered or crushed samples. A diagrammatic view of the instrument is shown.

Blake, D. F.↗

CheMin: A Definitive Mineralogy Instrument in the Analytical Laboratory of the Mars Science Laboratory

An important goal of the Mars Science Laboratory (MSL '09) mission is the determination of definitive mineralogy and chemical composition. CheMin is a miniature X-ray diffraction/X-ray fluorescence (XRD/XRF) instrument that has been chosen for the analytical laboratory of MSL. CheMin utilizes a miniature microfocus source cobalt X-ray tube, a transmission sample cell and an energy-discriminating X-ray sensitive CCD to produce simultaneous 2-D X-ray diffraction patterns and X-ray fluorescence spectra from powdered or crushed samples. A diagrammatic view of the instrument is shown. Additional information is included in the original extended abstract.

Blake, David F.↗

Determination of Carbon Functional Groups in Pyrolysis Bio-Oils using 13 C NMR: Laboratory Analytical Procedure (LAP)

Pyrolysis is a process that can be used to convert biomass to solid, liquid and gaseous products for use as renewable chemicals and fuels. The liquid fraction, known as “bio-oil” is complex and challenging to characterize, particularly by means of GC/MS, GPC, LC and FT-IR. NMR is capable of analyzing whole bio-oil samples and can provide quantitative results to characterize different functional groups or types of carbon present in bio-oil. This Laboratory Analytical Procedure (LAP) quantifies different carbon functional groups in whole bio-oil samples. This information can be used for comparisons between different pyrolysis experimental conditions or different upgrading processes and catalysts, and also allow for comparisons between bio-oils produced at different facilities.

09 BIOMASS FUELS↗

Determination of Carbon, Hydrogen, Nitrogen, and Oxygen in Bio-Oils: Laboratory Analytical Procedure (LAP)

The determination of total carbon, hydrogen, and nitrogen in bio-oils is important as these values can be used to track the carbon balance of production processes as well as calculate total oxygen content by difference. Oxygen content of bio-oils is a key metric for production and upgrading strategies as these are typically aimed at reducing oxygen. Oxygenates in bio-oils contribute to poor hydrocarbon miscibility, high acidity, high viscosity, and poor stability. Upgrading of bio-oils via deoxygenation produces hydrocarbons which can be used to generate feedstocks for renewable fuels and chemicals. In this Laboratory Analytical Procedure (LAP), combustion-based ultimate analysis is used to determine the weight percent (wt%) of C, H, and N in bio-oils and upgraded products. Ultimate analysis uses high temperatures and a pure oxygen environment to completely combust organic samples to carbon dioxide (CO 2 ), water (H 2 O), and nitrogen oxides (NO x ). In this procedure the amount of C and H in the sample are quantified by measuring resultant CO 2 and H 2 O with Fourier-transform infrared spectroscopy (FTIR). For N, NO x is reduced to nitrogen (N 2 ) which is measured with a thermal conductivity detector (TCD), providing total N content.

09 BIOMASS FUELS↗

Determination of Phenolic Groups in Bio-Oils Using Revised Folin-Ciocalteu Methods: Single Cuvette and Plate Reader. Laboratory Analytical Procedure (LAP), Issue Date: May 12, 2022

Phenol components are ubiquitous in wood-derived bio-oils and biocrudes. Their reaction with other functional groups (e.g., aldehydes) may contribute to the formation of carbonaceous species and the expected thermal instability of pyrolysis oils. During hydrotreating, phenols can be recalcitrant species, requiring higher reaction temperatures than other oxygen-containing functional groups. Phenols are also present in upgraded products and have been shown to lead to catalyst deactivation during hydrotreating. They also are the first oxygenated functional group to re-appear in the upgraded product, signaling catalyst deactivation. This procedure covers the determination of phenolic compounds in fast pyrolysis oils. This Laboratory Analytical Procedure (LAP) includes two methods, the first allowing for shorter analysis time at increased reaction temperature, while the second employs a longer analysis time but at room temperature. Additionally, the use of both a single cuvette and of a plate reader are also presented.

09 BIOMASS FUELS↗

Elemental Analysis of Bio-Oils by Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). Laboratory Analytical Procedure (LAP), Issue Date: May 13, 2022

Concentrations of inorganic elements is a key quality metric for bio-oils as certain elements impact upgrading processes and product quality. Unless reduced or removed during production and processing, alkali and alkaline metals native to lignocellulosic biomass can carry over into bio-oils contributing to ash content and degraded catalyst performance during upgrading to hydrocarbon fuels or chemical products. Non-metallic elements such as sulfur and phosphorus can also negatively impact upgrading catalysts and product quality. Inductively coupled plasma optical emission spectroscopy (ICP-OES) can be used to measure inorganic elements of interest in bio-oils. This procedure covers the preparation and analysis of fast pyrolysis (FP) and catalytic fast pyrolysis (CFP) bio-oils. The concentrations of these elements can indicate potential bio-oil quality from the perspective of deoxygenation processes. The implications of elemental composition will depend on process parameters such as upgrading catalyst sensitivities. This Laboratory Analytical Procedure (LAP) covers two methods for quantification of inorganic elements by ICP-OES: Procedure A uses microwave assisted digestion with concentrated nitric acid, and Procedure B is an organic ICP-OES method utilizing a diglyme solvent.

09 BIOMASS FUELS↗

Determination of Water Content in Bio-Oils by Volumetric Karl Fischer Titration: Laboratory Analytical Procedure (LAP)

The water content of bio-oils is a key metric for several reasons. Water is typically the most concentrated single component of fast pyrolysis oils, though this will be much lower in catalytic fast pyrolysis and upgraded products. Reduced water content is preferable in bio-oil as water can contribute to phase separation, corrosivity, and instability. Additionally, lower water is beneficial for physical properties such as energy density. The percentage of water can also be used to correct the calculation for organic oxygen when determining total oxygen content of bio-oils via combustion-based ultimate analysis. The procedure described here is specifically written for the analysis of bio-oils, and is based on ASTM E203, Standard Test Method for Water Using Volumetric Karl Fischer Titration. This standard test method is specified for measuring the mass % water in pyrolysis liquid biofuels in ASTM D7544, Standard Specification for Pyrolysis Liquid Biofuel. Although the standard method is prescribed for the analysis of pyrolysis liquids for use in industrial and commercial burners, the method is not specifically written for this product. The method described with this Laboratory Analytical Procedure (LAP) provides specific guidance for the analysis of bio-oils. Both organic and aqueous phases can be measured with this technique.

09 BIOMASS FUELS↗