Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ambient Air”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Secondary organic aerosol formation from ambient air in an oxidation flow reactor in central Amazonia

Abstract. Secondary organic aerosol (SOA) formation from ambient air was studied using an oxidation flow reactor (OFR) coupled to an aerosol mass spectrometer (AMS) during both the wet and dry seasons at the Observations and Modeling of the Green Ocean Amazon (GoAmazon2014/5) field campaign. Measurements were made at two sites downwind of the city of Manaus, Brazil. Ambient air was oxidized in the OFR using variable concentrations of either OH or O3, over ranges from hours to days (O3) or weeks (OH) of equivalent atmospheric aging. The amount of SOA formed in the OFR ranged from 0 to as much as 10 µg m−3, depending on the amount of SOA precursor gases in ambient air. Typically, more SOA was formed during nighttime than daytime, and more from OH than from O3 oxidation. SOA yields of individual organic precursors under OFR conditions were measured by standard addition into ambient air and were confirmed to be consistent with published environmental chamber-derived SOA yields. Positive matrix factorization of organic aerosol (OA) after OH oxidation showed formation of typical oxidized OA factors and a loss of primary OA factors as OH aging increased. After OH oxidation in the OFR, the hygroscopicity of the OA increased with increasing elemental O:C up to O:C∼1.0, and then decreased as O:C increased further. Possible reasons for this decrease are discussed. The measured SOA formation was compared to the amount predicted from the concentrations of measured ambient SOA precursors and their SOA yields. While measured ambient precursors were sufficient to explain the amount of SOA formed from O3, they could only explain 10–50 % of the SOA formed from OH. This is consistent with previous OFR studies, which showed that typically unmeasured semivolatile and intermediate volatility gases (that tend to lack C=C bonds) are present in ambient air and can explain such additional SOA formation. To investigate the sources of the unmeasured SOA-forming gases during this campaign, multilinear regression analysis was performed between measured SOA formation and the concentration of gas-phase tracers representing different precursor sources. The majority of SOA-forming gases present during both seasons were of biogenic origin. Urban sources also contributed substantially in both seasons, while biomass burning sources were more important during the dry season. This study enables a better understanding of SOA formation in environments with diverse emission sources.

54 ENVIRONMENTAL SCIENCES↗

Ambient air pollution and semen quality

Highlights: • Sperm development is sensitive to oxidative stress, a key effect of air pollution. • Prior evidence is inconclusive for an effect of air pollution on semen quality. • Ambient air pollution was not associated with most semen quality parameters. • Fine particulate matter was associated with smaller sperm head measures. • Findings are generally reassuring for healthy men exposed to moderate air pollution. Ambient air pollution is associated with systemic increases in oxidative stress, to which sperm are particularly sensitive. Although decrements in semen quality represent a key mechanism for impaired fecundability, prior research has not established a clear association between air pollution and semen quality. To address this, we evaluated the association between ambient air pollution and semen quality among men with moderate air pollution exposure.

54 ENVIRONMENTAL SCIENCES↗

Efficiency of Room Air Cleaners for Removal of Bioaerosols From Ambient Air

The COVID-19 pandemic necessitated the evaluation of commercial air purification units to protect worker safety in indoor spaces. This project evaluated the efficacy of commercial off-the-shelf air purification systems that utilize electrostatic precipitation for the collection and removal of particulates (including bioaerosols) from ambient air. An aerosol mist containing Escherichia coli (E. coli) and bacteriophage surrogate virus, MS2, was produced using a nebulizer and delivered to the front intake of the commercial system with the ionizer ON and OFF. Removal efficiency was evaluated by colony/plaque formation assays using a small agar plate (60 X 15 mm) to passively collect E. coli and MS2 exhausting from the electrostatic precipitation cell. The system was determined to remove 98-99% of the microorganism introduced to the system. Testing was performed with all pre- and post-electrostatic cell filters removed so further removal is anticipated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Performance, Hybrid Polymer Membrane for Carbon Dioxide Separation from Ambient Air

The Department of Energy (DOE) seeks to develop carbon capture materials specifically tailored for Direct Air Capture (DAC) processes. Related to this, they require recipients to develop novel DAC materials such as: solvents, membranes, or sorbents that demonstrate high affinities or capacities for carbon dioxide (CO2) at concentrations typically available in air and at near ambient conditions. Toward this, InnoSense LLC (ISL) is developing High-Performance, Hybrid Polymer Membranes (HypoMemTM) for Carbon Dioxide Separation from Ambient Air. HypoMem consists of two major layers. The first layer is the active layer which contains the active ingredients that help to separate CO2 from ambient air. The second is the support layer that provides good mechanical support to have a free-standing membrane without interfering with the properties of the active layer.

20 FOSSIL-FUELED POWER PLANTS↗

Ambient air cooling arrangement having a pre-swirler for gas turbine engine blade cooling

A gas turbine engine including: an ambient-air cooling circuit (10) having a cooling channel (26) disposed in a turbine blade (22) and in fluid communication with a source (12) of ambient air: and an pre-swirler (18), the pre-swirler having: an inner shroud (38); an outer shroud (56); and a plurality of guide vanes (42), each spanning from the inner shroud to the outer shroud. Circumferentially adjacent guide vanes (46, 48) define respective nozzles (44) there between. Forces created by a rotation of the turbine blade motivate ambient air through the cooling circuit. The pre-swirler is configured to impart swirl to ambient air drawn through the nozzles and to direct the swirled ambient air toward a base of the turbine blade. The end walls (50, 54) of the pre-swirler may be contoured.

42 ENGINEERING↗

Long-term exposure to ambient air pollution (including PM1) and metabolic syndrome: The 33 Communities Chinese Health Study (33CCHS)

Highlights: • Associations of ambient air pollution with metabolic syndrome were scarcely studied. • Data from 15,477 Chinese adults were analyzed. • Long-term exposure to air pollution was associated with metabolic syndrome. • Demographic and lifestyle factors modified the association between metabolic syndrome and air pollution. Little evidence exists about the effects of long-term exposure to ambient air pollution on metabolic syndrome (MetS). This study aimed to determine the association between long-term ambient air pollution and MetS in China. A total of 15,477 adults who participated in the 33 Communities Chinese Health Study (33CCHS) in 2009 were evaluated. MetS was defined based on the recommendation by the Joint Interim Societies. Exposure to air pollutants was assessed using data from monitoring stations and a spatial statistical model (including particles with diameters ≤ 1.0 µm (PM{sub 1}), ≤ 2.5 µm (PM{sub 2.5}), and ≤ 10 µm (PM{sub 10}), sulfur dioxide (SO{sub 2}), nitrogen dioxide (NO{sub 2}), and ozone (O{sub 3})). Two-level logistic regression analyses were utilized to assess the associations between air pollutants and MetS. The prevalence of MetS was 30.37%. The adjusted odds ratio of MetS per 10 µg/m{sup 3} increase in PM{sub 1}, PM{sub 2.5}, PM{sub 10}, SO{sub 2}, NO{sub 2}, and O{sub 3} were 1.12 (95% CI = 1.00–1.24), 1.09 (95% CI = 1.00–1.18), 1.13 (95% CI = 1.08–1.19), 1.10 (95% CI = 1.02–1.18), 1.33 (95% CI = 1.12–1.57), and 1.10 (95% CI = 1.01–1.18), respectively. Stratified analyses indicated that the above associations were stronger in participants with the demographic variables of males, < 50 years of age, and higher income, as well as with the behavioral characteristics of smoking, drinking, and consuming sugar-sweetened soft drinks frequently. This study indicates that long-term exposure to ambient air pollutants may increase the risk of MetS, especially among males, the young to middle aged, those of low income, and those with unhealthy lifestyles.

54 ENVIRONMENTAL SCIENCES↗

Cooling system with compressor bleed and ambient air for gas turbine engine

A cooling system for a turbine engine for directing cooling fluids from a compressor to a turbine blade cooling fluid supply and from an ambient air source to the turbine blade cooling fluid supply to supply cooling fluids to one or more airfoils of a rotor assembly is disclosed. The cooling system may include a compressor bleed conduit extending from a compressor to the turbine blade cooling fluid supply that provides cooling fluid to at least one turbine blade. The compressor bleed conduit may include an upstream section and a downstream section whereby the upstream section exhausts compressed bleed air through an outlet into the downstream section through which ambient air passes. The outlet of the upstream section may be generally aligned with a flow of ambient air flowing in the downstream section. As such, the compressed air increases the flow of ambient air to the turbine blade cooling fluid supply.

42 ENGINEERING↗

Apparatus and method for maintaining an article at a temperature that is less than the temperature of the ambient air

An apparatus for maintaining the temperature of an article at a temperature that is below the ambient air temperature includes an enclosure having an outer wall that defines an interior chamber for holding a volume of sealed air. An insert is disposed inside of the chamber and has a body that is made of a porous graphite foam material. A vacuum pump penetrates the outer wall and fluidly connects the sealed air in the interior chamber with the ambient air outside of the enclosure. The temperatures of the insert and article is maintained at temperatures that are below the ambient air temperature when a volume of a liquid is wicked into the pores of the porous insert and the vacuum pump is activated to reduce the pressure of a volume of sealed air within the interior chamber to a pressure that is below the vapor pressure of the liquid.

42 ENGINEERING↗

Influence of ambient air pressure on effervescent atomization

The influence of ambient air pressure on the drop-size distributions produced in effervescent atomization is examined in this article. Also investigated are the effects on spray characteristics of variations in air/liquid mass ratio, liquid-injection pressure, and atomizer discharge-orifice diameter at different levels of ambient air pressure. It is found that continuous increase in air pressure above the normal atmospheric value causes the mean drop-size to first increase up to a maximum value and then decline. An explanation for this characteristic is provided in terms of the various contributing factors to the overall atomization process. It is also observed that changes in atomizer geometry and operating conditions have little effect on the distribution of drop-sizes in the spray.

Chen, S. K.↗

Ambient air pollution and pregnancy outcomes: A comprehensive review and identification of environmental public health challenges

There is a growing number of studies on the association between ambient air pollution and adverse pregnancy outcomes, but their results have been inconsistent. Consequently, a comprehensive review of this research area is needed. There was a wide variability in studied pregnancy outcomes, observed gestational windows of exposure, observed ambient air pollutants, applied exposure assessment methods and statistical analysis methods Gestational duration, preterm birth, (low) birth weight, and small for gestational age/intrauterine growth restriction were most commonly investigated pregnancy outcomes. Gestational windows of exposure typically included were whole pregnancy period, 1st, 2nd, 3rd trimester, first and last gestational months. Preterm birth was the outcome most extensively studied across various gestational windows, especially at the beginning and at the end of pregnancy. Particulate matter, nitrogen dioxide, ozone, and carbon monoxide were the most commonly used markers of ambient air pollution. Continuous monitoring data were frequently combined with spatially more precisely modelled estimates of exposure. Exposure to particulate matter and ozone over the entire pregnancy was significantly associated with higher risk for preterm birth: the pooled effect estimates were 1.09 (1.03–1.16) per 10 μg/m{sup 3} increase in particulate matter with an aerodynamic diameter of 10 µm or less (PM{sub 10}){sub ,}1.24 (1.08–1.41) per 10 μg/m{sup 3} increase in particulate matter with an aerodynamic diameter of 2.5 µm or less (PM{sub 2.5}), and 1.03 (1.01–1.04) per 10 ppb increase in ozone. For pregnancy outcomes other than PTB, ranges of observed effect estimates were reported due to smaller number of studies included in each gestational window of exposure. Further research is needed to link the routine pregnancy outcome data with spatially and temporally resolved ambient air pollution data, while adjusting for commonly defined confounders. Methods for assessing exposure to mixtures of pollutants, indoor air pollution exposure, and various other environmental exposures, need to be developed.

54 ENVIRONMENTAL SCIENCES↗

From K‐O 2 to K‐Air Batteries: Realizing Superoxide Batteries on the Basis of Dry Ambient Air

Abstract Although using an air cathode is the goal for superoxide‐based potassium‐oxygen (K‐O 2 ) batteries, prior studies were limited to pure oxygen. Now, the first K‐air (dry) battery based on reversible superoxide electrochemistry is presented. Spectroscopic and gas chromatography analyses are applied to evaluate the reactivity of KO 2 in ambient air. Although KO 2 reacts with water vapor and CO 2 to form KHCO 3 , it is highly stable in dry air. With this knowledge, rechargeable K‐air (dry) batteries were successfully demonstrated by employing dry air cathode. The reduced partial pressure of oxygen plays a critical role in boosting battery lifespan. With a more stable environment for the K anode, a K‐air (dry) battery delivers over 100 cycles (>500 h) with low round‐trip overpotentials and high coulombic efficiencies as opposed to traditional K‐O 2 battery that fails early. This work sheds light on the benefits and restrictions of employing the air cathode in superoxide‐based batteries.

Qin, Lei↗

Prototype development and test results of a continuous ambient air monitoring system for hydrazine at the 10 ppb level

A Hydrazine Vapor Area Monitor (HVAM) system is currently being field tested as a detector for the presence of hydrazine in ambient air. The MDA/Polymetron Hydrazine Analyzer has been incorporated within the HVAM system as the core detector. This analyzer is a three-electrode liquid analyzer typically used in boiler feed water applications. The HVAM system incorporates a dual-phase sample collection/transport method which simultaneously pulls ambient air samples containing hydrazine and a very dilute sulfuric acid solution (0.0001 M) down a length of 1/4 inch outside diameter (OD) tubing from a remote site to the analyzer. The hydrazine-laden dilute acid stream is separated from the air and the pH is adjusted by addition of a dilute caustic solution to a pH greater than 10.2 prior to analysis. Both the dilute acid and caustic used by the HVAM are continuously generated during system operation on an "as needed" basis by mixing a metered amount of concentrated acid/base with dilution water. All of the waste water generated by the analyzer is purified for reuse by Barnstead ion-exchange cartridges so that the entire system minimizes the generation of waste materials. The pumping of all liquid streams and mixing of the caustic solution and dilution water with the incoming sample are done by a single pump motor fitted with the appropriate mix of peristaltic pump heads. The signal to noise (S/N) ratio of the analyzer has been enhanced by adding a stirrer in the MDA liquid cell to provide mixing normally generated by the high liquid flow rate designed by the manufacturer. An onboard microprocessor continuously monitors liquid levels, sample vacuum, and liquid leak sensors, as well as handles communications and other system functions (such as shut down should system malfunctions or errors occur). The overall system response of the HVAM can be automatically checked at regular intervals by measuring the analyzer response to a metered amount of calibration standard injected into the dilute acid stream. The HVAM system provides two measurement ranges (threshold limit value (TLV): 10 to 1000 parts per billion (ppb)/LEAK: 100 ppb to 10 parts per million (ppm)). The LEAK range is created by dilution of the sulfuric acid/hydrazine liquid sample with pure water. This dual range capability permits the analyzer to quantify ambient air samples whose hydrazine concentrations range from 10 ppb to as high as 10 ppm. The laboratory and field prototypes have demonstrated total system response times on the order of 10 to 12 minutes for samples ranging from 10 to 900 ppb in the lLV mode and is greater than 2 minutes for samples ranging from 100 to 1300 ppb in the LEAK mode. Service intervals of over 3 months have been demonstrated for continuous 24 hour/day, 7 day/week usage. The HVAM is made up of a purged cabinet that contains power supplies, RS422 signal transmission capabilities, a UPS, an on-site warning system, and a Line Replaceable Unit (LRU). The LRU includes all of the liquid flow system, the analyzer, the control/data system microprocessor and assorted flow and liquid-level sensors. The LRU is mounted on a track slide system so it can be serviced inplace or totally removed and quickly exchanged with another calibrated unit, thus minimizing analyzer downtime. Once an LRU is removed from an analyzer enclosure, it can be brought to a laboratory facility for complete calibration and periodic maintenance.

Meneghelli, Barry↗