A network of soil moisture, soil temperature, air temperature, net radiation, ground heat flux and ground water for Chicago, Illinois

This dataset contains environmental monitoring data collected using solar-powered Multi-Function Research (MFR) Long Range Wide Area (LoRaWAN)-enabled nodes at 11 sites in Chicago, Illinois, as part of the DOE Urban Integrated Field Lab CROCUS project. The MFR node system consists of an Input/Output Digital Input Module (IB8) interface box (ICT International) providing wired connections for environmental sensors and an MFR-Node-L data logger that manages power, data processing, and LoRaWAN communication. The wireless data are ingested via Sage network (https://sagecontinuum.org/) nodes that contain LoRaWAN antennae. Measurements were collected from 11 MFR nodes deployed across Chicago State University (CSU), Northeastern Illinois University (NEIU), Northwestern University (NU), University of Illinois Chicago (UIC), West Woodlawn "Blacks in Green" (BIG), and Indian Boundary Prairies (IBP). Each MFR node supports a consistent suite of sensors measuring atmospheric, soil, and hydrological variables. Atmospheric measurements include 2m air temperature (°C), 2m vapor pressure deficit (kPa), and 2m shortwave/longwave radiation (incoming and outgoing, W/m²) measured using ATH-VPD and Apogee SN500 sensors. Soil measurements include volumetric water content (VWC, %) and temperature (°C) at four depths (15, 30, 45, and 60 cm below surface) using Meter Teros54 sensors, and heat flux (W/m²) at 10 cm depth using Huske HFP01-05 sensors. At selected locations, Meter Hydros21 sensors measure groundwater depth (mm), specific conductivity (dS/m), and temperature (°C). The dataset includes timestamps, site identifiers with location names, device IDs, Global Positioning System (GPS) coordinates, variable names with units, measurement depths, values, sensor names, and Sage node identifiers. All timestamps are in local Chicago time (CDT/CST). Quality control flags are provided using a 6-bit binary system indicating physical range violations, step spikes, 24-hour flat-line conditions, 6-hour jitter, 7-day ultra-low variance, and persistent high offset. Data is provided in CSV and CF-compliant NetCDF formats. This dataset is part of a larger collection of CROCUS environmental monitoring data, including linked datasets from Air Quality Transmitter (AQT) sensors, Weather Transmitter (WXT) sensors, and Sap Flow Meter (SFM1x) sensors.

Chicago

The influence of snow depth and surface air temperature on satellite-derived microwave brightness temperature

Areas of the steppes of central Russia, the high plains of Montana and North Dakota, and the high plains of Canada were studied in an effort to determine the relationship between passive microwave satellite brightness temperature, surface air temperature, and snow depth. Significant regression relationships were developed in each of these homogeneous areas. Results show that sq R values obtained for air temperature versus snow depth and the ratio of microwave brightness temperature and air temperature versus snow depth were not as the sq R values obtained by simply plotting microwave brightness temperature versus snow depth. Multiple regression analysis provided only marginal improvement over the results obtained by using simple linear regression.

Foster, J. L.

Effect of Air Temperature and Relative Humidity at Various Fuel-Air Ratios on Exhaust Emissions on a Per-Mode Basis of an AVCO Lycoming 0-320 Diad Light Aircraft Engine: Volume 1: Results and Plotted Data

A carbureted four cylinder air cooled 0-320 DIAD Lycoming aircraft engine was tested to establish the effects of air temperature and humidity at various fuel-air ratios on the exhaust emissions on a per-mode basis. The test conditions include carburetor lean out at air temperatures of 50, 59, 80, and 100 F at relative humidities of 0, 30, 60, and 80 percent. Temperature humidity effects at the higher values of air temperature and relative humidity tested indicated that the HC and CO emissions increased significantly, while the NOx emissions decreased. Even at a fixed fuel air ratio, the HC emissions increase and the NOx emissions decrease at the higher values of air temperature and humidity.

Skorobatckyi, M.

Effect of air temperature and relative humidity at various fuel-air ratios on exhaust emissions on a per-mode basis of an Avco Lycoming 0-320 DIAD light aircraft engine. Volume 2: Individual data points

A carbureted four cylinder air cooled 0-320 DIAD Lycoming aircraft engine was tested to establish the effects of air temperature and humidity at various fuel-air ratios on the exhaust emissions on a per-mode basis. The test conditions included carburetor lean-out at air temperatures of 50, 59, 80, and 100 F at relative humidities of 0, 30, 60, and 80 percent. Temperature-humidity effects at the higher values of air temperature and relative humidity tested indicated that the HC and CO emissions increased significantly, while the NOx emissions decreased. Even at a fixed fuel-air ratio, the HC emissions increase and the NOx emissions decrease at the higher values of air temperature and humidity. Volume II contains the data taken at each of the individual test points.

Skorobatckyi, M.

Wet-Bulb Temperature from Pressure, Relative Humidity, and Air Temperature

Abstract The algorithms currently in use for calculating the wet-bulb temperature from pressure, relative humidity, and air temperature have errors of a degree or more. Here, the equation for the thermodynamic wet-bulb temperature is derived using the Rankine–Kirchhoff approximations, which are highly accurate for meteorological and climatological applications. Likewise, equations are derived for the thermodynamic ice-bulb temperature and for the psychrometric wet-bulb and ice-bulb temperatures. The equations are fast to solve, requiring only a microsecond on a current laptop computer, and the results match empirical data to within hundredths of a degree. Furthermore, the equations reveal the existence of air temperatures and humidities that generate bistability: Evaporating liquid water is stable at a liquid temperature above freezing and, simultaneously, sublimating ice is stable at an ice temperature below freezing.

Romps, David M

The comparative performance of an aviation engine at normal and high inlet air temperatures

This report presents some results obtained during an investigation to determine the effect of high inlet air temperature on the performance of a Liberty 12 aviation engine. The purpose of this investigation was to ascertain, for normal service carburetor adjustments and a fixed ignition advance, the relation between power and temperature for the range of carburetor air temperatures that may be encountered when supercharging to sea level pressure at altitudes of over 20,000 feet and without intercooling when using plain aviation gasoline and mixtures of benzol and gasoline. The results show that for the conditions of test, both the brake and indicated power decrease with increase in air temperature at a faster rate than given by the theoretical assumption that power varies inversely as the square root of the absolute temperature. On a brake basis, the order of the difference in power for a temperature difference of 120 degrees F. Is 3 to 5 per cent. The observed relation between power and temperature when using the 30-70 blend was found to be linear. But, although these differences are noted, the above theoretical assumption may be considered as generally applicable except where greater precision over a wide range of temperatures is desired, in which case it appears necessary to test the particular engine under the given conditions. (author)

Gardiner, Arthur W

Upper bounds for 21st-century surface air temperatures in the Western United States

The last decade has seen a large number of severe heatwaves that were unprecedented in the observational record, highlighting challenges associated with observationally-based statistical quantification of the likelihood and magnitude of future extreme temperatures. An alternative to such probabilistic assessments is identification of upper bounds that quantify the hottest surface air temperatures that can possibly be achieved by the end of the 21st century. Theory, simulations, and observational analyses support the existence of a finite upper bound for surface air temperature; however, estimates for future upper-bound values that are realistic and usable for planning remain unavailable. Here, we combine atmospheric theory with large ensembles of dynamically downscaled projections to estimate historical and end-of-century upper bounds for surface air temperatures. A number of physical mechanisms can influence upper bounds, and at the end of the 21st century, estimates based on mechanisms that yield more moderate upper-bounds produce values around 60∘C for much of the Western United States and in excess of 80∘C for the hottest parts of the domain. Even cooler high-altitude locations have end-of-century upper bounds over 50∘C. Although these upper-bound estimates might seem implausibly large, increases in the upper bounds over the 21st century are similar to increases in dynamically downscaled peak surface temperatures after adjusting those downscaled temperatures to eliminate the possibly biased model trends in surface specific humidity. While upper bound estimates are high relative to historical observations, they nonetheless suggest that heatwave intensity risk is bounded, with uncertainty dominated by projections of surface and upper-level humidity.

Risser, Mark D

Study of Ram-air Heat Exchangers for Reducing Turbine Cooling-air Temperature of a Supersonic Aircraft Turbojet Engine

The sizes and weights of the cores of heat exchangers were determined analytically for possible application for reducing turbine cooling-air temperatures of an engine designed for a Mach number of 2.5 and an altitude The sizes and weights of the cores of heat exchangers were determined analytically for possible application for reducing turbine cooling-air temperatures of an engine designed for a Mach number of 2.5 and an altitude of 70,000 feet. A compressor-bleed-air weight flow of 2.7 pounds per second was assumed for the coolant; ram air was considered as the other fluid. Pressure drops and inlet states of both fluids were prescribed, and ranges of compressor-bleed-air temperature reductions and of the ratio of compressor-bleed to ram-air weight flows were considered.

Diaguila, Anthony J

Feasibility of estimation of surface air temperature from meteorological satellite data test plan

A conceptual system designed to estimate daily surface air temperatures utilizing radiometric data obtained from polar orbiting meteorological satellites is discussed in this memorandum. The Surface Air Temperature Estimation System is an outgrowth of previous developmental and operational systems. The system represents an effort to integrate both satellite and surface meteorological observations into an operational framework which would be usable worldwide.

Phinney, D. E.

Apparatus and method for generating large mass flow of high temperature air at hypersonic speeds

High temperature, high mass air flow and a high Reynolds number test air flow in the Mach number 8-10 regime of adequate test flow duration is attained by pressurizing a ceramic-lined storage tank with air to a pressure of about 100 to 200 atmospheres. The air is heated to temperatures of 7,000 to 8,000 R prior to introduction into the tank by passing the air over an electric arc heater means. The air cools to 5,500 to 6,000 R while in the tank. A decomposable gas such as nitrous oxide or a combustible gas such as propane is injected into the tank after pressurization and the heated pressurized air in the tank is rapidly released through a Mach number 8-10 nozzle. The injected gas medium upon contact with the heated pressurized air effects an exothermic reaction which maintains the pressure and temperature of the pressurized air during the rapid release.

Sabol, A. P.

Data Center Waste Heat as an Emerging Urban Thermal Hazard: First Field Measurements of Neighborhood-Scale Air Temperature Impacts

Data centers are among the fastest-growing sources of concentrated anthropogenic heat in urban environments. Despite heat flux densities that exceed peak solar irradiance by a factor of 2–6, their thermal impacts on adjacent communities have never been directly measured or reported in the peer-reviewed literature. This short communication addresses that gap by presenting the first vehicle-based traverse measurements of air temperature in residential neighborhoods downwind of operational data centers. Five traverses at four facilities in the Phoenix, Arizona metropolitan area, ranging from a 36 MW single-building data center in Mesa to a 169 MW colocation campus in Chandler, reveal downwind air temperature warming as high as 2.2 °C, with average downwind air temperatures 0.7–0.9 °C warmer than corresponding upwind areas. Thermal signatures were detectable at distances up to 500 m from facility perimeters. The 36 MW Mesa facility rejects waste heat equivalent to the electricity consumption of approximately 40,000 households, while the 169 MW Chandler campus is equivalent to over 180,000 households, both concentrated into footprints smaller than a single residential subdivision. With U.S. data center capacity projected to more than double by 2030, these findings establish data center anthropogenic waste heat as a previously undocumented urban thermal hazard demanding attention from the data center and urban planning communities.

Phoenix

Effectiveness of street trees in reducing air temperature and outdoor heat exposure in Las Vegas

Urban greening and especially tree planting strategies are being widely planned and implemented to mitigate urban overheating and thermal stress in many urban areas. However, the effectiveness of these strategies depends on multiple factors, including urban morphology, environmental conditions, and tree characteristics. This study investigates the effects of street tree planting strategies on air temperature and outdoor heat exposure in Las Vegas by combining an urbanized mesoscale climate model coupled to a multi-layer street tree model (Weather Research and Forecasting-BEP-Tree; Δ x = 900 m) with a microscale pedestrian heat exposure model (Temperatures of Urban Facets for Pedestrian; Δ x = 1 m). A series of simulations are conducted for July and August 2022. Large city-wide increases of a drought tolerant tree species cool air temperature mainly during the nighttime (up to 1.5 °C), with daytime effects being limited due to leaves shedding sensible instead of latent heat as stomata close in response to high vapor pressure deficits. Increased evaporative cooling is achieved with a different tree species (double at night, and reaching 0.4 °C during the day), but water requirements increase threefold. Despite their relatively small effect on air temperature during the day, trees provide significant shade by intercepting solar radiation, reducing mean radiant temperature (up to 16 °C) and enhancing outdoor thermal comfort, a major benefit of street trees in hot arid climates. The nighttime cooling of trees and the daytime reduction of radiant loading show potential to reduce the heat-related health impacts. Our results highlight the need to evaluate the effects of street trees on a case-by-case basis.

54 ENVIRONMENTAL SCIENCES

A Review of the Thermodynamic, Transport, and Chemical Reaction Rate Properties of High-temperature Air

Thermodynamic and transport properties of high temperature air, and the reaction rates for the important chemical processes which occur in air, are reviewed. Semiempirical, analytic expressions are presented for thermodynamic and transport properties of air. Examples are given illustrating the use of these properties to evaluate (1) equilibrium conditions following shock waves, (2) stagnation region heat flux to a blunt high-speed body, and (3) some chemical relaxation lengths in stagnation region flow.

Hansen, C Frederick

Global trends of measured surface air temperature

The paper presents the results of surface air temperature measurements from available meteorological stations for the period of 1880-1985. It is shown that the network of meteorological stations is sufficient to yield reliable long-term, decadal, and interannual temperature changes for both the Northern Hemisphere and the Southern Hemisphere, despite the fact that most stations are located on the continents. The results indicate a global warming of about 0.5-0.7 C in the past century, with warming of similar magnitude in both hemispheres. A strong warming trend between 1965 and 1980 raised the global mean temperature in 1980 and 1981 to the highest level in the period of instrumental records. Selected graphs of the temperature change in each of the eight latitude zones are included.

Hansen, James

Approximations for the Thermodynamic and Transport Properties of High-Temperature Air

The thermodynamic and transport properties of high-temperature air are found in closed form starting from approximate partition functions for the major components in air and neglecting all minor components. The compressibility, enthalpy, entropy, the specific heats, the speed of sound, the coefficients of viscosity and of thermal conductivity, and the Prandtl numbers for air are tabulated from 500 degrees to 15,000 degrees Kelvin over a range of pressure from 0.0001 to 100 atmospheres. The energy of air and the mol. fractions of the major components of air can be found from the tabulated values for compressibility and enthalpy. It is predicted that the Prandtl number for fully ionized air, which is in complete equilibrium, will become small compared to unity, the order of 0.01, and this implies that boundary layers in such flow will be very transparent to heat flux.

Hansen, C. Frederick