Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Air dehumidifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Heat Pipe Precools and Reheats Dehumidified Air

Precooling and reheating by heat pipe reduces operating costs of air-conditioning. Warm air returned from air-conditioned space and cooled air supplied are precooled and reheated, respectively, by each other through a heat pipe. Heat-pipe technology brought to bear on problem of conserving airconditioning energy in hot, humid environments. Any increase in the cost of equipment due to installation of heat-pipe heat exchangers expected to be recovered in energy savings during service period of 2 years or less.

Koning, R. C.↗

Dehumidifying Heat Pipe

U-shaped heat pipe partly dehumidifies air leaving air conditioner. Fits readily in air-handling unit of conditioner. Evaporator and condenser sections of heat pipe consist of finned tubes in comb pattern. Each tube sealed at one end and joined to manifold at other. Sections connected by single pipe carrying vapor to condenser manifold and liquid to evaporator manifold. Simple on/off or proportional valve used to control flow of working fluid. Valve actuated by temperature/humidity sensor.

Khattar, Mukesh K.↗

Regenerable Liquid Desiccants for High Efficiency Humidity Control in Microgravity

The NASA X-Hab project aims to design, manufacture, test, and prove functionality of an air humidity control subsystem to dehumidify and re-humidify air from a space cabin. The method of regulating cabin air humidity utilizes vortex phase separation, which uses an ionic liquid (IL) desiccant for air-water phase separation. This subsystem is intended to be integrated with a CO 2 removal system requiring de-humidified air to operate efficiently. The air humidity control subsystem is composed of a cold-desiccant or cold-side Vortex Phase Separator (VPS) that dehumidifies the cabin air. The dehumidified air exits the cold-side (CS) VPS chamber to flow into the CO 2 removal module, and the cold, water-laden liquid desiccant flows to a regenerative heat exchanger. From the heat exchanger the liquid desiccant continues to the heater. After heating, the desiccant flows into a hot-desiccant or hot-side (HS) VPS as the dehumidified air from CO 2 removal module enters through the HS VPS air inlet. The rehumidified air exits the HS VPS into the space cabin. One pump installed at the liquid exit of the CS VPS and one pump installed at the liquid exit of the HS VPS transport the fluid through the system. To evaluate the system’s efficiency and effectiveness, the temperature, pressure, flow rate and relative humidity are read, recorded, and analyzed at critical points along the module.

Gerardo Castro↗

Analysis of a membrane-based condesate recovery heat exchanger (CRX)

The development of a temperature and humidity control system that can remove heat and recover water vapor is key to the development of an Environmental Control and Life Support System (ECLSS). Large quantities of water vapor must be removed from air, and this operation has proven difficult in the absense of gravity. This paper presents the modeling results from a program to develop a novel membrane-based heat exchanger known as the condensate recovery heat exchanger (CRX). This device cools and dehumidifies humid air and simultaneously recovers water-vapor condensate. In this paper, the CRX is described and the results of an analysis of the heat- and mass-transfer characteristics of the device are given.

Newbold, D.D.↗

A Study of Mars Dust Environment Simulation at NASA Johnson Space Center Energy Systems Test Area Resource Conversion Test Facility

The dust environment on Mars is planned to be simulated in a 20 foot thermal-vacuum chamber at the Johnson Space Center, Energy Systems Test Area Resource Conversion Test Facility in Houston, Texas. This vacuum chamber will be used to perform tests and study the interactions between the dust in Martian air and ISPP hardware. This project is to research, theorize, quantify, and document the Mars dust/wind environment needed for the 20 foot simulation chamber. This simulation work is to support the safety, endurance, and cost reduction of the hardware for the future missions. The Martian dust environment conditions is discussed. Two issues of Martian dust, (1) Dust Contamination related hazards, and (2) Dust Charging caused electrical hazards, are of our interest. The different methods of dust particles measurement are given. The design trade off and feasibility were studied. A glass bell jar system is used to evaluate various concepts for the Mars dust/wind environment simulation. It was observed that the external dust source injection is the best method to introduce the dust into the simulation system. The dust concentration of 30 Mg/M3 should be employed for preparing for the worst possible Martian atmosphere condition in the future. Two approaches thermal-panel shroud for the hardware conditioning are discussed. It is suggested the wind tunnel approach be used to study the dust charging characteristics then to be apply to the close-system cyclone approach. For the operation cost reduction purpose, a dehumidified ambient air could be used to replace the expensive CO2 mixture for some tests.

Chen, Yuan-Liang Albert↗

Electrolysis cell functions as water vapor dehumidifier and oxygen generator

Water vapor is absorbed in hygroscopic electrolyte, and oxygen generated by absorbed water electrolysis at anode is added simultaneously to air stream. Cell applications include on-board aircraft oxygen systems, portable oxygen generators, oxygen concentration requirements, and commercial air conditioning and dehumidifying systems.

Clifford, J. E.↗

Simulation Helps Improve Atmosphere Revitalization Systems for Manned Spacecraft

Life support systems for manned spacecraft must provide breathable air and drinkable water for the astronauts. Through the Atmosphere Revitalization Recovery and Environmental Monitoring (ARREM) project, engineers at NASA are developing atmosphere control devices for the safety of the onboard crew. The atmosphere in a manned spacecraft needs to be regularly revitalized in order to ensure the safety of the astronauts and the success of the space mission. For missions lasting a few months, this means air is continuously dehumidified, water collected for re-use, and carbon dioxide (CO2) ejected. One component of the onboard atmosphere control system is a water-saving device that Jim Knox, aerospace engineer at NASA, is optimizing through the Atmosphere Revitalization Recovery and Environmental Monitoring (ARREM) project. He is leading a team at the Marshall Space Flight Center (Huntsville, Alabama) that is aiming to make the assembly more cost-effective and efficient by reducing its power usage and maximizing the water saved; their goal is to save 80-90% of the water in the air. They hope to offer flight system developers at NASA an integrated approach to atmosphere revitalization and water collection that will ultimately increase the time and distance space missions can travel.

Knox, James C.↗

Modelling and experimental verification of a water alleviation system for the NASP

One possible low speed propulsion system for the National Aerospace Plane is a liquid air cycle engine (LACE). The LACE system uses the heat sink in the liquid hydrogen propellant to liquefy air in a heat exchanger which is then pumped up to high pressure and used as the oxidizer in a hydrogen liquid air rocket. The inlet airstream must be dehumidified or moisture could freeze on the cryogenic heat exchangers and block them. The main objective of this research has been to develop a computer simulation of the cold tube/antifreeze-spray water alleviation system and to verify the model with experimental data. An experimental facility has been built and humid air tests were conducted on a generic heat exchanger to obtain condensing data for code development. The paper describes the experimental setup, outlines the method of calculation used in the code, and presents comparisons of the calculations and measurements. Cause of discrepancies between the model and data are explained.

Vanfossen, G. James↗

Development of an Additively Manufactured Capacitive Humidity Sensor for the International Space Station

The ability to measure humidity on the International Space Station and other long-duration spaceflight missions is a crucial part of the onboard systems. For example, the Environmental Control and Life Support System (ECLSS) needs to know the amount of humidity in the air to make decisions about whether it should spend power to run the dehumidifier systems to attempt to reclaim that water. Other issues can arise if the humidity reaches too high of levels and condensation builds up on electrical components. With that in mind, it is vital that the spacecraft keeps spare sensors on board or has the ability to manufacture new sensors on demand. An additively manufactured sensor would be additionally beneficial because it would save space onboard that would normally be taken up by spares, save money from costly resupply missions, and allow the sensor to be constantly updated with the most effective design. This Technical Memorandum outlines a development process carried out to design, manufacture, and test an additively manufactured humidity sensor.

Chang, K. T.↗

Water cycles in closed ecological systems: effects of atmospheric pressure

In bioregenerative life support systems that use plants to generate food and oxygen, the largest mass flux between the plants and their surrounding environment will be water. This water cycle is a consequence of the continuous change of state (evaporation-condensation) from liquid to gas through the process of transpiration and the need to transfer heat (cool) and dehumidify the plant growth chamber. Evapotranspiration rates for full plant canopies can range from ~1 to 10 L m-2 d-1 (~1 to 10 mm m-2 d-1), with the rates depending primarily on the vapor pressure deficit (VPD) between the leaves and the air inside the plant growth chamber. VPD in turn is dependent on the air temperature, leaf temperature, and current value of relative humidity (RH). Concepts for developing closed plant growth systems, such as greenhouses for Mars, have been discussed for many years and the feasibility of such systems will depend on the overall system costs and reliability. One approach for reducing system costs would be to reduce the operating pressure within the greenhouse to reduce structural mass and gas leakage. But managing plant growth environments at low pressures (e.g., controlling humidity and heat exchange) may be difficult, and the effects of low-pressure environments on plant growth and system water cycling need further study. We present experimental evidence to show that water saturation pressures in air under isothermal conditions are only slightly affected by total pressure, but the overall water flux from evaporating surfaces can increase as pressure decreases. Mathematical models describing these observations are presented, along with discussion of the importance for considering "water cycles" in closed bioregenerative life support systems.

NASA Center KSC↗