Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Air Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Whole Air Sampling During NASA's March-April 1999 Pacific Exploratory Expedition (PEM-Tropics B)

University of California, Irvine (UCI) collected more than 4500 samples whole air samples collected over the remote Pacific Ocean during NASA's Global Tropospheric Experiment (GTE) Pacific Exploratory Mission-Tropics B (PEM-Tropics B) in March and early April 1999. Approximately 140 samples during a typical 8-hour DC-8 flight, and 120 canisters for each 8-hour flight aboard the P-3B. These samples were obtained roughly every 3-7 min during horizontal flight legs and 1-3 min during vertical legs. The filled canisters were analyzed in the laboratory at UCI within ten days of collection. The mixing ratios of 58 trace gases comprising hydrocarbons, halocarbons, alkyl nitrates and DMS were reported (and archived) for each sample. Two identical analytical systems sharing the same standards were operated simultaneously around the clock to improve canister turn-around time and to keep our measurement precision optimal. This report presents a summary of the results for sample collected.

Blake, Donald R.

Does Collection Time Bias the Ecology of Cleanroom Air Samples?

Microbial monitoring of astromaterials collections has taken on increased importance with the return of biologically sensitive samples from the asteroids Ryugu and Bennu and the initiation of the Mars Sample Return Program. Terrestrial bacteria and fungi can alter the mineralogy and organic composition of our collections causing irreversible contamination of pristine samples and increasing the risk of false positives for life detection measurements. NASA has conducted routine microbial monitoring of its existing collections since 20181. Initial monitoring focused on surface samples collected with foam swabs. Although, airborne microbiology is often decoupled from surface microbiology in the built environment2 culture-based air sampling techniques like impactors were not compliant with existing contamination control requirements. Bringing organic rich media, gelatin or liquids into curation cleanrooms presents an unacceptable risk to pristine samples. In 2022 NASA purchased a materials complaint air sampler and began collecting air samples from the cleanrooms in addition to surface samples3. The new instrument uses an electret filter to collect samples that are suitable for cultivating organisms or for direct DNA sequencing. Preliminary DNA sequencing results appeared to indicate that longer sampling times biased the microbial community in favor of hearty, spore-forming bacteria3. We present the results of a study comparing overnight sampling (17 hours) to short (1 hour) sampling of unoccupied curation cleanrooms. The results will help us optimize our monitoring protocols and develop a more detailed inventory of the ecology of astromaterials curation cleanrooms. Methods: We analyzed 72 paired air samples from six different cleanrooms including the meteorite processing lab (ISO 7 equivalent, 16 samples), the lunar lab (ISO 6 equivalent, 10 samples), the stardust lab (ISO 5 equivalent 14 samples), the OSIRIS-REx lab (ISO 5 equivalent, 12 samples), the Hayabusa2 lab (ISO 5 equivalent, 14 samples), and the Genesis lab (ISO 4 equivalent, 6 samples). All the samples were collected with an InnovaPrep Bobcat air sampler operating at a sampling rate of 200 L/min. The sampler operates for 5 minutes out of every 20 minute period. Half of the samples were collected by filtering 3,000L (15 min. of active sampling) of air across an electret filter for one hour. The rest of the samples were collected by filtering approximately 51,000 L air across the filter overnight (~17 hours, 255 min. of active sampling). Cells were eluted from the filter using 6-7 ml of pressurized 0.15% tween 20 in PBS (phosphate buffered saline). This liquid was used to cultivate bacteria according to previously published methods1,4,5 and for DNA extraction and next generation sequencing. DNA was extracted with a Qiagen MagAttract PowerMicrobiome kit6. To identify bacteria and archaea, the 16S rRNA gene was amplified using Earth Microbiome primers for the V4 region 7. The amplified DNA was sequenced on an Illumina MiSeq using a V3 reagent kit. The resulting sequences were processed using DADA2 and QIIME2 as implemented on the EDGE bioinformatics platform8–10. Results: Only two of the 72 samples had no amplifiable DNA. Amplified DNA concentrations ranged from 2.67 – 0.272 ng/µl. The median concentration of amplified DNA for the 1 hour samples was 0.770 ± 0.368 ng/µl. The median concentration of amplified DNA for the overnight samples was 0.877 ± 0.434 ng/µl. On average the overnight samples had slightly more sequences (58,960 vs. 59,456) and ASV’s (amplicon sequence variants) (60 vs 64.5) than the one hour samples, but these differences are not statistically significant. The most abundant ASV in every sample mapped to the genus Cupravidus. ASV’s mapping to the genuses Bacillus, Schlegelella, Thermus, and Staphylococcus were also common. Discussion and Future Work: Alpha diversity statistics like Shannon Entropy and Faith Phylogenetic Diversity are used to describe the diversity of organisms in a single sample. If a longer sampling time was biasing the data, we would expect to see a change in these diversity statistics vs. sample time. However, we did not observe this in our data. The median Shannon entropy was slightly higher for the overnight samples (3.773 vs 3.611) as was the Faith Phylogenetic Diversity (4.042 vs 3.596), but both values were within a standard deviation of each other for the two sampling times (Fig. 1). It is unlikely, that the longer sampling time is introducing bias into our data. We do observe a significant decrease in diversity when comparing the air samples by lab. The Genesis lab (ISO 4 equivalent) has a lower median number of ASV’s (45.5) than the other labs (62). Median values for Shannon Entropy (3.717 vs. 3.430) and Faith Phylogenetic Diversity (3.796 vs. 3.548) are also lower for Genesis, but those values are with one standard deviation of each other for the different sampling times. This is consistent with previous culture-based results suggesting that the environment in cleanrooms tends to select for a core group of organisms capable of surviving under dry, low nutrient, conditions. The presence of the ASV’s mapping to Cupravidus and Thermus in our sequencing blanks and controls suggests that several of the most common organisms in our samples represent contaminants from the reagents used to perform the DNA extractions and sequencing. Further work is needed to identify these contaminants, remove them from our data and recalculate the diversity statistics. This is a systematic error. Therefore, we do not expect removing the sequencing contaminants to change our conclusions. Longer air sample collection times appear to result in slightly higher diversity and do not bias the results towards “hardy” bacteria like spore-formers. Based on these preliminary results we conclude that sampling at least 3,000 liters of air is sufficient to capture the microbial diversity of cleanrooms, and that air samples can also be collected overnight without negatively impacting diversity. These results allow us to be flexible when designing microbial monitoring plans so that they do not interfere with routine lab activity. References: 1. Regberg, A. B. et al. 49th Lunar and Planetary Science Conference (2018). 2. The United States Pharmacopeial Convention. USP General Chapter <1116> (2013). 3. Regberg, A. B., et al. 54th Lunar and Planetary Science Conference (2023). 4. Regberg, A. B. et al. 53rd Lunar and Planetary Science Conference ( 2022). 5. Davis, R. E.,et al. 50th Lunar and Planetary Science Conference (2019). 6. Qiagen. MagAttract® PowerMicrobiome® DNA/RNA EP Kit Handbook. (2018). 7. Walters, W. et al. mSystems 1, (2015). 8. Callahan, B. J. et al. Nat. Methods 13, 581–583 (2016). 9. Hall, M. & Beiko, R. G. Microbiome Analysis: Methods and Protocols113–129 (Springer, 2018). 10. Philipson, C. et al. Bio-Protoc. 7, e2622 (2017).

A. B. Regberg

Air-sampling inlet contamination by aircraft emissions on the NASA CV-990 aircraft

Results of an experimental investigation of the contamination of air sampling inlets by aircraft emissions from the NASA CV-990 research aircraft are presented. This four-engine jet aircraft is a NASA facility used for many different atmospheric and meteorological experiments, as well as for developing spacecraft instrumentation for remote measurements. Our investigations were performed to provide information on which to base the selection of sampling locations for a series of multi-instrument missions for measuring tropospheric trace gases. The major source of contamination is the exhaust from the jet engines, which generate many of the same gases that are of interest in atmospheric chemistry, as well as other gases that may interfere with sampling measurements. The engine exhaust contains these gases in mixing ratios many orders of magnitude greater than those that occur in the clean atmosphere which the missions seek to quantify. Pressurized samples of air were collected simultaneously from a scoop located forward of the engines to represent clean air and from other multiport scoops at various aft positions on the aircraft. The air samples were analyzed in the laboratory by gas chromatography for carbon monoxide, an abundant combustion by-product. Data are presented for various scoop locations under various flight conditions.

Condon, E. P.

Venturi Air-Jet Vacuum Ejector For Sampling Air

Venturi air-jet vacuum ejector pump light in weight, requires no electrical power, does not contribute heat to aircraft, and provides high pumping speeds at moderate suctions. High-pressure motive gas required for this type of pump bled from compressor of aircraft engine with negligible effect on performance of engine. Used as source of vacuum for differential-absorption CO-measurement (DACOM), modified to achieve in situ measurements of CO at frequency response of 10 Hz. Provides improvement in spatial resolution and potentially leads to capability to measure turbulent flux of CO by use of eddy-correlation technique.

Hill, Gerald F.

Trace gas measurements from whole air samples collected over the Antarctic continent

Whole air samples collected aboard the NASA DC-8 and ER-2 aircraft as part of the Airborne Antarctic Ozone Experiment (AAOE) were analyzed in a field laboratory set up at Punta Arenas, Chile, in August and September, 1987. Mixing ratios obtained from gas chromatographic analyses of these samples are presented for N2O, CFCl3, CFCl2, C2F3Cl3, CH3CCl3, CH4, and CO. Variations in the mixing ratios of these gases along the individual flight paths of the aircraft are used as tracers to indicate the history of air masses over and near the Antarctic continent.

Heidt, L. E.

Multistage open-tube trap for enrichment of part-per-trillion trace components of low-pressure (below 27-kPa) air samples

A multistage open-tube trap for cryogenic collection of trace components in low-pressure air samples is described. The open-tube design allows higher volumetric flow rates than densely packed glass-bead traps commonly reported and is suitable for air samples at pressures below 27 kPa with liquid nitrogen as the cryogen. Gas blends containing 200 to 2500 parts per trillion by volume each of ethane and ethene were sampled and hydrocarbons were enriched with 100 + or - 4 percent trap efficiency. The multistage design is more efficient than equal-length open-tube traps under the conditions of the measurements.

Ohara, D.

Diagnosing AIRS Sampling with CloudSat Cloud Classes

AIRS yield and sampling vary with cloud state. Careful utilization of collocated multiple satellite sensors is necessary. Profile differences between AIRS and ECMWF model analyses indicate that AIRS has high sampling and excellent accuracy for certain meteorological conditions. Cloud-dependent sampling biases may have large impact on AIRS L2 and L3 data in climate research. MBL clouds / lower tropospheric stability relationship is one example. AIRS and CloudSat reveal a reasonable climatology in the MBL cloud regime despite limited sampling in stratocumulus. Thermodynamic parameters such as EIS derived from AIRS data map these cloud conditions successfully. We are working on characterizing AIRS scenes with mixed cloud types.

model analyses

Mathematical estimation of the level of microbial contamination on spacecraft surfaces by volumetric air sampling

Microbiological sampling methods presently used for enumeration of microorganisms on spacecraft surfaces require contact with easily damaged components. Estimation of viable particles on surfaces using air sampling methods in conjunction with a mathematical model would be desirable. Parameters necessary for the mathematical model are the effect of angled surfaces on viable particle collection and the number of viable cells per viable particle. Deposition of viable particles on angled surfaces closely followed a cosine function, and the number of viable cells per viable particle was consistent with a Poisson distribution. Other parameters considered by the mathematical model included deposition rate and fractional removal per unit time. A close nonlinear correlation between volumetric air sampling and airborne fallout on surfaces was established with all fallout data points falling within the 95% confidence limits as determined by the mathematical model.

Oxborrow, G. S.

Determination of trace gases in learjet and U-2 whole air samples collected during the intertropical convergence zone experiment

The contribution of Washington State University (WSU) to the Intertropical Convergence Zone (ITCZ) study, conducted in the Panama Canal Zone in July 1977 is reported. The ITCZ program had the objective to study the meteorology and air chemistry to determine, if possible, the magnitude of injection of tropospheric air into the stratosphere in the ITCZ. WSU was responsible for two phases of the air chemistry program for the ITCZ study: (1) the collection of whole-air samples from ground level to 13.7 km using a Learjet as a sampling platform, and the analysis of the samples for selected halocarbons, C2 hydrocarbons, N2O, and SF6; and (2) the analysis for selected halocarbon species and N2O of low pressure whole-air samples, collected between 13.7 km and 21.3 km by a U-2 aircraft. The report is divided into separate sections describing the Learjet and the U-2 sampling methods, analytical methods, and results. Complete data tables for all samples analyzed are given.

Cronn, D. R.

Air Sampling Filter

General Metal Works' Accu-Vol is a high-volume air sampling system used by many government agencies to monitor air quality for pollution control purposes. Procedure prevents possible test-invalidating contamination from materials other than particulate pollutants, caused by manual handling or penetration of windblown matter during transit, a cassette was developed in which the filter is sealed within a metal frame and protected in transit by a snap-on aluminum cover, thus handled only under clean conditions in the laboratory.

Source record

Ozone measurement system for NASA global air sampling program

The ozone measurement system used in the NASA Global Air Sampling Program is described. The system uses a commercially available ozone concentration monitor that was modified and repackaged so as to operate unattended in an aircraft environment. The modifications required for aircraft use are described along with the calibration techniques, the measurement of ozone loss in the sample lines, and the operating procedures that were developed for use in the program. Based on calibrations with JPL's 5-meter ultraviolet photometer, all previously published GASP ozone data are biased high by 9 percent. A system error analysis showed that the total system measurement random error is from 3 to 8 percent of reading (depending on the pump diaphragm material) or 3 ppbv, whichever are greater.

Tiefermann, M. W.

Partitioning of ocean and land uptake of CO2 as inferred by delta C-13 measurements from the NOAA Climate Monitoring and Diagnostics Laboratory Global Air Sampling Network

Using delta C-13 measurements in atmospheric CO2 from a cooperative global air sampling network, we determined the partitioning of the net uptake of CO2 between ocean and land as a function of latitude and time. The majority of delta C-13 measurements were made at the Institute of Arctic and Alpine Research (INSTAAR) of the University of Colorado. We perform an inverse deconvolution of both CO2 and delta C-13 observations, using a two-dimensional model of atmospheric transport. Also, the discrimination against C-13 by plant photosynthesis, as a function of latitude and time, is calculated from global runs of the simple biosphere (SiB) model. Uncertainty due to the longitudinal structure of the data, which is not represented by the model, is studied through a bootstrap analysis by adding and omitting measurement sites. The resulting error estimates for our inferred sources and sinks are of the order of 1 GTC (1 GTC = 10(exp 15) gC). Such error bars do not reflect potential systematic errors arising from our estimates of the isotopic disequilibria between the atmosphere and the oceans and biosphere, which are estimated in a separate sensitivity analysis. With respect to global totals for 1992 we found that 3.2 GTC of carbon dissolved into the ocean and that 1.5 GTC were sequestered by land ecosystems. Northern hemisphere ocean gyres north of 15 deg N absorbed 2.7 GTC. The equatorial oceans between 10 deg S and 10 deg N were a net source to the atmosphere of 0.9 GTC. We obtained a sink of 1.6 GTC in southern ocean gyres south of 20 deg S, although the deconvolution is poorly constrained by sparse data coverage at high southern latitudes. The seasonal uptake of CO2 in the northern gyres appears to be correlated with a bloom of phytoplankton in surface waters. On land, northern temperate and boreal ecosystems between 35 deg N and 65 deg N were found to be a major sink of CO2 in 1992, as large as 3.5 GTC. Northern tropical ecosystems (equator-30 deg N) appear to be a net source to the source to the atmosphere of 2 GTC which could reflect biomass burning. A small sink, 0.3 GTC, was inferred for southern tropical ecosystems (30 deg S-equator).

Ciais, Philippe

Ground vibration test and flutter analysis of air sampling probe

The Dryden Flight Research Facility of NASA Ames Research Center conducted a ground vibration test and a flutter analysis of an air sampling probe that was to be mounted on a Convair 990 airplane. The probe was a steel, wing-shaped structure used to gather atmospheric data. The ground vibration test was conducted to update the finite-element model used in the flutter analysis. The analysis predicted flutter speeds well outside the operating flight envelope of the Convair 990 airplane.

Ellison, J. F.

STS 134, 135 and 26S Return Samples: Air Quality aboard Shuttle (STS-134) and International Space Station

This is a very limited set of samples on which to perform an air quality assessment. However, based on these samples, we have no reason to believe that nominal ISS air is unsafe to breathe. We must continue to be vigilant when dealing with nominal atmospheres in ISS. New, unmanned modules require special attention when the crew first enters. Carbon Monoxide Accumulation aboard ISS: Beginning in late 2008 the nominal concentrations of CO began increasing gradually (Figure 1). The results from samples returned on this flight indicate that the CO concentrations, after dropping in late 2009, have cycled upward and then settled back to concentrations near 2 mg/m3. In any case, these changes are well below the 180-day SMAC for CO, which is17 mg/m3. There is no threat to crew health. Carbon Dioxide: This anthropogenic compound has drawn much attention recently because of the possibility that it could contribute to the effects of intracranial hypertension experienced because of spaceflight-induced fluid shifts. From now on we will maintain a plot (Figure 2) of carbon dioxide concentrations ( SD) by averaging the values found in the 3-5 mini-GSC samples taken each month in diverse locations of the ISS. This will enable us to estimate the average exposure of crewmembers to carbon dioxide during their stay aboard the ISS. In general, concentrations are being maintained below 3.5 mmHg. Figure 1

James, John T.

Collection and analysis of NASA clean room air samples

The environment of the HALOE assembly clean room at NASA Langley Research Center is analyzed to determine the background levels of airborne organic compounds. Sampling is accomplished by pumping the clean room air through absorbing cartridges. For volatile organics, cartridges are thermally desorbed and then analyzed by gas chromatography and mass spectrometry, compounds are identified by searching the EPA/NIH data base using an interactive operator INCOS computer search algorithm. For semivolatile organics, cartridges are solvent entracted and concentrated extracts are analyzed by gas chromatography-electron capture detection, compound identification is made by matching gas chromatogram retention times with known standards. The detection limits for the semivolatile organics are; 0.89 ng cu m for dioctylphlhalate (DOP) and 1.6 ng cu m for polychlorinated biphenyls (PCB). The detection limit for volatile organics ranges from 1 to 50 parts per trillion. Only trace quantities of organics are detected, the DOP levels do not exceed 2.5 ng cu m and the PCB levels do not exceed 454 ng cu m.

Sheldon, L. S.