Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Adhesion forces”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Potential-Dependent Adhesion Forces between dsDNA and Electroactive Surfaces

A promising approach to regulating the interactions between polyelectrolytes and materials is the use of electroactive surfaces that can change their charge state. However, common electroactive groups are too unstable to be practical for this purpose. Here we have performed a single molecule force spectroscopy study of the interactions between dsDNA and an 1,1'-biferrocenylene (BFD = bis(fulvalene)diiron)-terminated self-assembled monolayer surface that allows us to reversibly change the charge state. We found that the interaction force between DNA and the surface is correlated to the oxidation state of the BFD groups, which is conveniently controlled by the electrochemical potentials. We discovered that the electroactive SAM produces much stronger interaction forces than its nonelectroactive counterpart. A model based on the Grahame equation was able to quantitatively reproduce the experimentally observed relation between the applied potentials and adhesion forces. Our electroactive surface provides a model system for quantitative studies of the interactions between polyelectrolyte and charged surfaces in liquid. Furthermore, these insights may enable new opportunities for actively manipulating the binding, orientations, and conformations of polyelectrolytes for biosensing, nanomotors, and other applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Friction and Adhesion Forces of Bacillus thuringiensis Spores on Planar Surfaces in Atmospheric Systems

The kinetic friction force and the adhesion force of Bacillus thuringiensis spores on planar surfaces in atmospheric systems were studied using atomic force microscopy. The influence of relative humidity (RH) on these forces varied for different surface properties including hydrophobicity, roughness, and surface charge. The friction force of the spore was greater on a rougher surface than on mica, which is atomically flat. As RH increases, the friction force of the spores decreases on mica whereas it increases on rough surfaces. The influence of RH on the interaction forces between hydrophobic surfaces is not as strong as for hydrophilic surfaces. The friction force of the spore is linear to the sum of the adhesion force and normal load on the hydrophobic surface. In conclusion, the poorly defined surface structure of the spore and the adsorption of contaminants from the surrounding atmosphere are believed to cause a discrepancy between the calculated and measured adhesion forces.

59 BASIC BIOLOGICAL SCIENCES↗

Graphene thickness dependent adhesion force and its correlation to surface roughness

In this paper, adhesion force of graphene layers on 300 nm silicon oxide is studied. A simple model for measuring adhesion force for a flat surface with sub-nanometer roughness was developed and is shown that small surface roughness decreases adhesion force while large roughness results in an effectively larger adhesion forces. We also show that surface roughness over scales comparable to the tip radius increase by nearly a factor of two, the effective adhesion force measured by the atomic force microscopy. Thus, we demonstrate that surface roughness is an important parameter that should be taken into account in analyzing the adhesion force measurement results.

36 MATERIALS SCIENCE↗

Study of the time effect on the strength of cell-cell adhesion force by a novel nano-picker

Highlights: {yields} A nano-picker is developed for single cell adhesion force measurement. {yields} The adhesion of picker-cell has no influence to the cell-cell measurement result. {yields} Cell-cell adhesion force has a rise at the first few minutes and then becomes constant. -- Abstract: Cell's adhesion is important to cell's interaction and activates. In this paper, a novel method for cell-cell adhesion force measurement was proposed by using a nano-picker. The effect of the contact time on the cell-cell adhesion force was studied. The nano-picker was fabricated from an atomic force microscopy (AFM) cantilever by nano fabrication technique. The cell-cell adhesion force was measured based on the deflection of the nano-picker beam. The result suggests that the adhesion force between cells increased with the increasing of contact time at the first few minutes. After that, the force became constant. This measurement methodology was based on the nanorobotic manipulation system inside an environmental scanning electron microscope. It can realize both the observation and manipulation of a single cell at nanoscale. The quantitative and precise cell-cell adhesion force result can be obtained by this method. It would help us to understand the single cell interaction with time and would benefit the research in medical and biological fields potentially.

60 APPLIED LIFE SCIENCES↗

Measurement of cell adhesion force by vertical forcible detachment using an arrowhead nanoneedle and atomic force microscopy

Graphical abstract: - Highlights: • We developed a method to measure cell adhesion force by detaching cell using an arrowhead nanoneedle and AFM. • A nanofilm consisting of fibronectin and gelatin was formed on cell surface to reinforce the cell cortex. • By the nanofilm lamination, detachment efficiencies of strongly adherent cell lines were improved markedly. - Abstract: The properties of substrates and extracellular matrices (ECM) are important factors governing the functions and fates of mammalian adherent cells. For example, substrate stiffness often affects cell differentiation. At focal adhesions, clustered–integrin bindings link cells mechanically to the ECM. In order to quantitate the affinity between cell and substrate, the cell adhesion force must be measured for single cells. In this study, forcible detachment of a single cell in the vertical direction using AFM was carried out, allowing breakage of the integrin–substrate bindings. An AFM tip was fabricated into an arrowhead shape to detach the cell from the substrate. Peak force observed in the recorded force curve during probe retraction was defined as the adhesion force, and was analyzed for various types of cells. Some of the cell types adhered so strongly that they could not be picked up because of plasma membrane breakage by the arrowhead probe. To address this problem, a technique to reinforce the cellular membrane with layer-by-layer nanofilms composed of fibronectin and gelatin helped to improve insertion efficiency and to prevent cell membrane rupture during the detachment process, allowing successful detachment of the cells. This method for detaching cells, involving cellular membrane reinforcement, may be beneficial for evaluating true cell adhesion forces in various cell types.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of Adhesion Forces Between Dust Particles and Solar Glass

We investigate the adhesion mechanisms that occur in the first stages of soiling by measuring adhesion forces between different kinds of particles and solar glass, using force vs. distance curves in an atomic force microscope (AFM). To simulate several degrees of roughness, we polished the samples at different conditions. We studied the effects of relative humidity by performing the measurements in a glove box and in an AFM enclosure. The measurements revealed that the main interactions are van der Waals and capillary forces. We show the dependence of the adhesion force on the several parameters and provide an explanation of how they operate.

14 SOLAR ENERGY↗

Effects of Solar-Glass Coatings on the Adhesion Forces Related to Soiling

We report on the impact that different coatings on solar glass have on the adhesion forces with SiO 2 spheres, which are used to emulate real dust particles. We measured the forces in an atomic force microscope, using force versus distance measurements, and performed the investigation at different values of relative humidity, from 15% to 80%. We will show that, in general, bare solar glass has the largest adhesive forces, with a strong influence of RH. In contrast, some coatings result in much lower adhesion forces and little influence of humidity, which suggests that these coatings may help reduce soiling, and have an impact on soiling associated with dew formation and some cementation processes.

14 SOLAR ENERGY↗

Adhesion-force micro-scale study of desiccating granular material

Experiments on five-, four-, three- and two-wet-hydrophilic-grain clusters were performed to investigate evolution of adhesion of granular media during drying on the micro-scale. The experiments show that the adhesion-force of a cluster initially grows at most to three times the original value before decreasing to zero by the end of evaporation. The adhesion-force is composed of capillary pressure force acting over the liquid/solid contact surface area, and surface tension forces acting over the three-phase contact perimeter length. This is in contrast with most macro-scale phenomenological models, in which the only desaturation process variables affecting strength are suction and saturation. Both the contact surface area and contact perimeter length are reduced to zero upon complete liquid evaporation. The morphology of an evaporating water body evolves through slow flow controlled by evaporation rate, interrupted by various modes of fast air entry, which are non-equilibrium jumps of liquid/gas interfaces (Haines jumps). The instabilities involve large adhesion force discontinuities and substantial water mass reconfiguration with water flow in an extremely short time, which makes the process transient. The reconfigurations can reduce the original multi-grain water clusters to four-, three- and two-grain clusters by way of three different instability modes: of thin-sheet instability, or meniscus snap-through instability, depending on the sign of the Gauss curvature of the liquid surface, or finally, for two-grain bridges only, a liquid wire pinch-off. For larger meso-scale assemblies, however, the global adhesion-force evolution is little affected by the jumps. The air entries are potential sites for drying cracks. The (approximately) calculated capillary pressure for two- and three-grain clusters, in no cases is seen to reach high values, predicted from water retention curves.

Engineering↗

Strong Attraction and Adhesion Forces of Dust Particles by System Voltages of Photovoltaic Modules

We report for the first time on direct measurements using atomic force microscopy (AFM) of electric field induced attraction and adhesion forces associated with soiling on photovoltaic (PV) modules. Real dust particles and silica spheres as surrogate to simulating dust particles were glued to AFM probe cantilevers. The electric field induced force (Fes) was measured via AFM force-distance (f-z) curves, where the electric field was generated by applying a voltage (Vs) to a simulated PV module. Fes and van der Waals (Fvw) force contributions could be separated with the f-z curves. The results show that Fes ~2.5 u N on dust particles is ~5 times larger than Fvw ~0.5 u N at even Vs = -100 V (i.e., similar to large-module operating voltages). Fes increases by an order of magnitude as the applied potential increases from Vs = -100 V to Vs = -500 V. These adhesion forces are by far the strongest that we have measured using the AFM technique for 'initial' contact of particles. Furthermore, unlike the more typical short-range forces of Fvw and liquid bridge, Fes extends sub-millimeters to a millimeter beyond the PV module surface, creating large attraction forces to even uncharged dust particles (i.e., via induced dipoles) in the air. These results indicate that the high voltages typically used with PV arrays today will attract more dust particles from the air, hold the dust particles to the surface very strongly, and potentially induce other PV module surface effects, all of which could increase the power production losses because of soiling.

14 SOLAR ENERGY↗

Influence of surface potential on the adhesive force of radioactive gold surfaces

Radioactive particles may acquire surface potential through self-charging, and thus can behave differently from natural aerosols in atmospheric systems with respect to aggregation, deposition, resuspension, and transport to areas surrounding a radioactive source. Here, this work focuses on the adhesive force between radioactive particles and metallic surfaces, which relates to the deposition and resuspension of particles on surrounding surfaces. Scanning surface potential microscopy was employed to measure the surface potential of radioactive gold foil. Atomic force microscopy was used to investigate the adhesive force for gold that acquired surface charge either by irradiation or by application of an equivalent electrical bias. Overall, the adhesive force increases with increasing surface potential or relative humidity. However, a behavior that does not follow the general trend was observed for the irradiated gold at a high decay rate. A comparison between experimental measurements and calculated values revealed that the surface potential promotes adhesion. The contribution of the electrostatic force at high levels of relative humidity was lower than the one found using theoretical calculations due to the effects caused by enhanced adsorption rate of water molecules under a high surface charge density. Lastly, the results of this study can be used to provide a better understanding of the behavior of radioactive particles in atmospheric systems.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Autonomous Self-Healing Elastomers with Unprecedented Adhesion Force

Self-healable elastomers are extremely attractive due to their ability to prolong product lifetime. An additional function that could further expand their applications is strong adhesion force to clean and dusty surfaces. This study reports a series of autonomous self-healable and highly adhesive elastomers (ASHA-Elastomer) that are fabricated via a simple, efficient, and scalable process. The obtained elastomers exhibit outstanding mechanical properties with elongation at break up to 2102% and toughness (modulus of toughness) of 1.73 MJ m -3 . The damaged ASHA-Elastomer can autonomously self-heal with full recovery of functionalities, and the healing process is not affected by the presence of water. The elastomers are found to possess an ultrahigh adhesion force up to 3488 N m -1 , greatly outperforming previously reported self-healing adhesive elastomers. Furthermore, the adhesion force of the ASHA-Elastomer is negligibly affected by dust on the surface, in stark contrast with regular adhesive polymers that have adhesion strengths extremely sensitive to dust. The successful development of high-toughness, autonomous self-healable, and ultra-adhesive elastomers will enable a wide range of applications with enhanced longevity and versatility, including their use in sealants, adhesives, and stretchable devices.

36 MATERIALS SCIENCE↗

Glass-particle adhesion-force-distribution on clean (laboratory) and contaminated (outdoor) surfaces

This article explores whether laboratory-clean samples are representative of real outdoor surfaces – often covered in dust and other contaminants – with respect to adhesion properties, which ultimately affect particle resuspension. In this study, Atomic Force Microscopy (AFM) was used to measure the adhesion force between a clean, smooth glass particle (5 µm in diameter) and two glass slides, one prepared according to common laboratory practices (hereafter, clean glass) and a second one left outdoors for six weeks (hereafter, contaminated glass). It was found that the adhesion force distribution was bimodal for the clean glass while it showed three peaks for the contaminated glass. For both surfaces, the adhesion force showed a peak at very low adhesion values (< 100 nN) representing 1.2% of the measurements for the clean glass and 58% for the contaminated glass. This low-adhesion peak is important because it represents the particles that would be resuspended first even in light winds. The low adhesion-force measurements were associated with the presence of contaminants on the surface. Another notable difference between the adhesion force distributions was a long tail at high adhesion forces for clean glass (up to ~1900 nN) and the absence of the tail for the contaminated glass, which had a maximum adhesion force of 950 nN. The mean adhesion force on the contaminated glass was also lower than on the clean glass (206 ± 240 nN vs. 516 ± 354 nN). These observations indicate that the adhesion force distribution between a 5-µm smooth and clean glass sphere and the outdoor contaminated glass surface is quite different from that of the clean glass surface. Hence, one should be cautious when using adhesion force measurements from clean surfaces to estimate particle resuspension from outdoor surfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Manipulation of polystyrene nanoparticles on a silicon wafer in the peak force tapping mode in water: pH-dependent friction and adhesion force

The friction force between nanoparticles and a silicon wafer is a crucial parameter for cleaning processes in the semiconductor industry. However, little is known about the pH-dependency of the friction forces and the shear strength at the interface. Here, we push polystyrene nanoparticles, 100 nm in diameter, with the tip of an atomic force microscope and measure the pH-dependency of the friction, adhesion, and normal forces on a silicon substrate covered with a native silicon dioxide layer. The peak force tapping mode was applied to control the vertical force on these particles. We successively increased the applied load until the particles started to move. The main advantage of this technique over single manipulation processes is the achievement of a large number of manipulation events in short time and in a straightforward manner. Geometrical considerations of the interaction forces at the tip-particle interface allowed us to calculate the friction force and shear strength from the applied normal force depending on the pH of an aqueous solution. The results clearly demonstrated that particle removal should be performed with a basic solution at pH 9 because of the low interaction forces between particle and substrate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A test method for determining adhesion forces and Hamaker constants of cementitious materials using atomic force microscopy

A method for determining Hamaker constant of cementitious materials is presented. The method involved sample preparation, measurement of adhesion force between the tested material and a silicon nitride probe using atomic force microscopy in dry air and in water, and calculating the Hamaker constant using appropriate contact mechanics models. The work of adhesion and Hamaker constant were computed from the pull-off forces using the Johnson-Kendall-Roberts and Derjagin-Muller-Toropov models. Reference materials with known Hamaker constants (mica, silica, calcite) and commercially available cementitious materials (Portland cement (PC), ground granulated blast furnace slag (GGBFS)) were studied. The Hamaker constants of the reference materials obtained are consistent with those published by previous researchers. The results indicate that PC has a higher Hamaker constant than GGBFS. The Hamaker constant of PC in water is close to the previously predicted value C{sub 3}S, which is attributed to short hydration time ({<=} 45 min) used in this study.

36 MATERIALS SCIENCE↗

Long-lasting strong electrostatic attraction and adhesion forces of dust particles on photovoltaic modules

Photovoltaic (PV) energy-yield loss due to solar module soiling has become increasingly important as solar module deployment is now at the hundreds of gigawatts scale and continues to grow rapidly. The electrostatic attraction and adhesion force (F es ) of dust particles by the high voltages from solar panels have been reported to be 1 to 2 orders of magnitude stronger than the van der Waals and water capillary forces, which has been corroborated by observing the increase in system voltage-induced soiling rate by setting up an outdoor test. Here, we report another characteristic of F es on soiling - long-lasting or slow decay after turning off the high voltage applied to solar panels. The F es decay time varies across a wide time range of 1 to 10 h, depending on two factors: 1) whether the cell, the particle, or both were charged with high voltage before the voltages were turned off; and 2) how the cell was connected to the ground after the voltage was turned off - either connected through the power-supply electronics, directly connected to the ground, or electrically floated. The Fes decay is understood in terms of 1) net electrical charge dissipations in both particle and cell, 2) thermal disordering of dipole polarization in the module glass dielectrics, and 3) charge redistribution by the electrostatic interaction of particle and module glass. This long-lasting F es for hours can affect the solar panel soiling after sunset, and it can have an even greater effect when combined with water condensation at night.

14 SOLAR ENERGY↗

Screening in nanowires and nanocontacts: field emission, adhesion force, and contact resistance

The explanations of several nanoscale phenomena such as the field enhancement factor in field emission, the large decay length of the adhesion force between a metallic tip and a surface, and the contact resistance in a nanowire break junction have been elusive. Here we develop an analytical theory of Thomas-Fermi screening in nanoscale structures. We demonstrate that nanoscale dimensions give rise to an effective screening length that depends on geometry and physical boundary conditions. The above phenomena are shown to be manifestations of the effective screening length.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Understanding the bond-energy, hardness, and adhesive force from the phase diagram via the electron work function

Properties of metallic materials are intrinsically determined by their electron behavior. However, relevant theoretical treatment involving quantum mechanics is complicated and difficult to be applied in materials design. Electron work function (EWF) has been demonstrated to be a simple but fundamental parameter which well correlates properties of materials with their electron behavior and could thus be used to predict material properties from the aspect of electron activities in a relatively easy manner. In this article, we propose a method to extract the electron work functions of binary solid solutions or alloys from their phase diagrams and use this simple approach to predict their mechanical strength and surface properties, such as adhesion. Two alloys, Fe-Ni and Cu-Zn, are used as samples for the study. EWFs extracted from phase diagrams show same trends as experimentally observed ones, based on which hardness and surface adhesive force of the alloys are predicted. This new methodology provides an alternative approach to predict material properties based on the work function, which is extractable from the phase diagram. This work may also help maximize the power of phase diagram for materials design and development.

36 MATERIALS SCIENCE↗

Less Is More: Oligomer Extraction and Hydrothermal Annealing Increase PDMS Adhesion Forces for Materials Studies and for Biology-Focused Microfluidic Applications

Cues in the micro-environment are key determinants in the emergence of complex cellular morphologies and functions. Primary among these is the presence of neighboring cells that form networks. For high-resolution analysis, it is crucial to develop micro-environments that permit exquisite control of network formation. This is especially true in cell science, tissue engineering, and clinical biology. We introduce a new approach for assembling polydimethylsiloxane (PDMS)-based microfluidic environments that enhances cell network formation and analyses. We report that the combined processes of PDMS solvent-extraction and hydrothermal annealing create unique conditions that produce high-strength bonds between solvent-extracted PDMS (E-PDMS) and glass—properties not associated with conventional PDMS. Extraction followed by hydrothermal annealing removes unbound oligomers, promotes polymer cross-linking, facilitates covalent bond formation with glass, and retains the highest biocompatibility. Herein, our extraction protocol accelerates oligomer removal from 5 to 2 days. Resulting microfluidic platforms are uniquely suited for cell-network studies owing to high adhesion forces, effectively corralling cellular extensions and eliminating harmful oligomers. We demonstrate the simple, simultaneous actuation of multiple microfluidic domains for invoking ATP- and glutamate-induced Ca 2+ signaling in glial-cell networks. These E-PDMS modifications and flow manipulations further enable microfluidic technologies for cell-signaling and network studies as well as novel applications.

36 MATERIALS SCIENCE↗