NASA NTRS1993
High energy proton induced nuclear reaction products are examined using seven elements, namely, Aluminum, Silicon, Nickel, Copper, Zirconium, Tantalum, and Tungsten. The samples were in the form of plates, 2 x 2 x 1/8 inches. Activities due to Na-22 from Al, Co-56 and Co-57 from Ni, Co-58 from Cu, and Y-88 from Zr targets were detected. No induced activity was observed in Si, Ta, and W, most probably due to the long cooling times. Only the Zr sample contained a weak Be-7 peak, although Ta and W were also located at the leading edge of the spacecraft. Gamma-rays of individual isotopes were measured using high-resolution Ge(Li) solid state detector coupled to 4096-multichannel analyzer. Activities were calculated for Co-56 (846 keV) and Co-57 (122 and 136 keV's) at the time of the entry of the spacecraft and found to be 0.014 plus or minus 0.005 c/sec. g, 0.018 plus or minus 0.002 c/sec. g, and 0.0024 plus or minus 0.0007 c/sec. g, respectively.