Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Acoustic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Modeling Urban Acoustic Noise in the Las Vegas, NV Region

Ambient infrasound noise in quiet, rural environments has been extensively studied and well-characterized through noise models for several decades. More recently, creating noise models for high-noise rural environments has also become an area of active research. However, far less work has been done to create generalized low-frequency noise models for urban areas. The high ambient noise levels expected in cities and other highly populated areas means that these environments are regarded as poor locations for acoustic sensors, and historically, sensor deployment in urban areas were avoided for this reason. However, there are several advantages to placing sensors in urban environments, including convenience of deployment and maintenance, and increasingly, necessity, as more previously rural areas become populated. This study seeks to characterize trends in low-frequency urban noise by creating a background noise model for Las Vegas, NV, using the Las Vegas Infrasound Array (LVIA): a network of eleven infrasound sensors deployed throughout the city. Data included in this study spans from 2019 to 2021 and provides a largely uninterrupted record of noise levels in the city from 0.1–500 Hz, with only minor discontinuities on individual stations. We organize raw data from the LVIA sensors into hourly power spectral density (PSD) averages for each station and select from these PSDs to create frequency distributions for time periods of interest . These frequency distributions are converted into probability density functions (PDFs), which are then used to evaluate variations in frequency and amplitude over daily to seasonal timescale s. In addition to PDFs, the median, 5 th percentile, and 95 th percentile amplitude values are calculated across the entire frequency range. This methodology follows a well-established process for noise model creation.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Clustering Acoustic Background Noise in the Stratosphere Using Machine Learning

Infrasound, characterized by low-frequency sound inaudible to humans (<20 Hz), emanates from natural and anthropogenic sources. Its efficacy for monitoring phenomena necessitates robust sensing networks. Traditional ground-based infrasound sensors have limitations due to atmospheric dynamics and noise interference. Balloon-bore sensors have emerged as an alternative, offering reduced noise and improved capabilities. This study bridges clustering algorithms with balloon borne infrasound data, a domain yet to be explored. Employing K-Means, DBSCAN, and GMM algorithms on normalized and reshaped data and only normalized data from a New Zealand-based NASA balloon flight, insights into background noise at stratospheric altitudes were revealed. Despite challenges arising from distinguishing signals amid unique background noise, this research provides vital reference material for noise analysis and calibration. Beyond infrasound event capture, the dataset enriches comprehension of background noise characteristics in the southern hemisphere.

47 OTHER INSTRUMENTATION↗

A non-intrusive framework using acoustic signals and deep learning for boiling diagnostics in visual-limited environments

Accurate monitoring of boiling heat transfer is critical for safeguarding high-power systems operating in environments where conventional optical diagnostics are hindered by radiation fields or restricted visual accessibility. This study presents a non-intrusive framework that integrates hydroacoustic sensing with deep learning to infer near-wall boiling characteristics and enable predictive thermal assessment without visual access. In a prototypical subcooled flow-boiling facility representative of the Isotope Production Facility (IPF) at Los Alamos, hydrophones capture boiling-induced acoustic emissions that are transformed into background-removed Short-Time Fourier Transform (STFT) spectrograms. A convolutional neural network (CNN) then regresses heat flux, wall superheat, and key bubble parameters directly from these spectrograms. The CNN achieved predictive accuracy under nominal conditions and demonstrated robustness and generalization under acoustic noise for Signal-to-Noise Ratios (SNRs) down to approximately 0 dB. When integrated into an ANSYS CFX wall-boiling model, the acoustically inferred parameters reproduced boiling curve and critical heat flux (CHF) values consistent with image-based benchmarks. Furthermore, the model retained reliable performance under moderate variations in bulk temperature, flow rate, and hydrophone placement, confirming its generalizability across practical boundary conditions. These results demonstrate the feasibility of hydroacoustic-based deep learning as a viable path toward real-time, radiation-tolerant boiling diagnostics and predictive thermal safety assessment in inaccessible systems such as the IPF.

42 ENGINEERING↗

Infrasound direction of arrival determination using a balloon-borne aeroseismometer

Free-floating balloons are an emerging platform for infrasound recording, but they cannot host arrays sufficiently wide for multi-sensor acoustic direction finding techniques. Because infrasound waves are longitudinal, the balloon motion in response to acoustic loading can be used to determine the signal azimuth. This technique, called “aeroseismometry,” permits sparse balloon-borne networks to geolocate acoustic sources. This is demonstrated by using an aeroseismometer on a stratospheric balloon to measure the direction of arrival of acoustic waves from successive ground chemical explosions. A geolocation algorithm adapted from hydroacoustics is then used to calculate the location of the explosions.

47 OTHER INSTRUMENTATION↗

Identification of Acoustic Wave Signatures in the Ionosphere From Conventional Surface Explosions Using MF/HF Doppler Sounding

Here, we present an experiment to detect one ton TNT-equivalent chemical explosions using pulsed Doppler radar observations of isodensity layers in the ionospheric E region during two campaigns. The first campaign, conducted on 15 October 2019, produced potential detections of all three shots. The detections closely resemble the temporal and spectral properties predicted using the InfraGA ray tracing and weakly nonlinear waveform propagation model. Here the model predicts that within 6.5–7.25 min of each shot a waveform peaking between 0.9 and 0.4 Hz will impact the ionosphere at 100 km. As the waves pass through this region, they will imprint their signal on an isodensity layer, which is detectable using a Doppler radar operating at the plasma frequency of the isodensity. Within the time windows of each of the three shots in the first campaign, we detect enhanced wave activity peaking near 0.5 Hz. These waves were imprinted on the Doppler signal probing an isodensity layer at 2.785 MHz near 100 km altitude. Despite these detections, the method appears to be unreliable as none of the six shots from the second campaign, conducted on 10 July 2020 were detected. The observations from this campaign were characterized by an increased acoustic noise environment in the microbarom band and persistent scintillation on the radar returns. These effects obscured any detectable signal from these shots and the baseline noise was well above the detection levels of the first campaign.

47 OTHER INSTRUMENTATION↗

Condition monitoring of permanent magnet AC machines for all-electric transportation systems: State of the art

The current state of the art on emerging and efficient techniques for condition monitoring of permanent magnet (PM) alternating-current (AC) machines deployed in electric vehicle (EV) applications is presented. The discussion includes the most common and specific types of faults in PM motors, such as rotor demagnetisation and stator inter-turn faults, respectively. Fault indicators, such as voltage (v s ) and current (i s ) signals and machine signatures based on motor back electromotive force (EMF) (E B ) and magnetic flux (φ), are taken into account as a measuring quantity in diagnosing motor faults. Other signatures, including thermal analysis, acoustic noise, and vibrations, are also illustrated as some of the emerging techniques in estimating the performance of EV motors while under operations. In addition, various fault modelling methods, condition monitoring techniques, and comprehensive approaches applied in diagnosing the effect of machine faults during its incipient stages are illustrated. Since most of the fault diagnostic techniques discussed here include only machine-based quantities as fault indices/indicators, the provided solutions are therefore found to be more reliable and accurate for diagnosing the motor faults. This comprehensive review study is inclusive of the existing fault diagnostic techniques, which are currently employed in industrial and commercial practices, in addition to the new methodologies proposed by the authors. All the given condition monitoring schemes therefore seem significantly vital in estimating the state of health of PM AC machines while under operation in all-electric transportation systems.

33 ADVANCED PROPULSION SYSTEMS↗

S-band acoustoelectric amplifier in an InGaAs-AlScN-SiC architecture

Here, we report on an acoustoelectric slab waveguide heterostructure for phonon amplification using a thin Al 0.58 Sc 0.42 N film grown directly on a 4H-SiC substrate with an ultra-thin In 0.53 Ga 0.47 As epitaxial film heterogeneously integrated onto the surface of the Al 0.58 Sc 0.42 N. The aluminum scandium nitride film grown directly on silicon carbide enables a thin (∼850 nm thick) piezoelectric film to be deposited on a thermally conductive bulk substrate (370 W/m K for 4H-SiC); the high thermal conductivity of the substrate, large mobility of the semiconductor (∼7000 cm 2 /V s), and low carrier concentration (∼5 × 10 15 cm −3 ) yield low self-heating. A Sezawa mode with optimal overlap between the peak of its evanescent electric field and the semiconductor charge carriers is supported. The high velocity of the heterostructure materials allows us to operate the Sezawa mode amplifier at 3.05 GHz, demonstrating a gain of 500 dB/cm (40 dB in 800 μm). Additionally, a terminal end-to-end radio frequency gain of 7.7 dB and a nonreciprocal transmission of 52.6 dB are achieved with a dissipated DC power of 2.3 mW. In conclusion, the power added efficiency and acoustic noise figure are also characterized.

Hackett, L.↗

A Two-Step Control Approach for Torque Ripple and Vibration Reduction in Switched Reluctance Motor Drives

The objective of this work is to reduce the torque ripple and vibration in Switched Reluctance Motor (SRM) drives. To achieve such a goal, a two-step approach is proposed. In the first step, the reference current is profiled using an optimization method, aimed to reduce the torque pulsation. In the second, the optimum current profile is applied to the SRM through an adaptive hysteresis band controller to actively cancel the radial vibration. The proposed technique uses an optimization procedure based on the Field Reconstruction Method (FRM) and Non-Derivative Optimization Method to find the optimal current profile that mitigates the torque pulsation, however, the investigation has shown that the proposed excitation leads to a higher radial vibration, which has been mitigated by using an adaptive hysteresis band controller. The theoretical basis for the proposed approach is initially presented, followed by system modeling and simulation. In addition, experimental verification has been conducted using an 8/6 SRM to show the feasibility of the proposed approach. The proposed method alleviates the acoustic noise and torque pulsation in SRM and offers an effective step towards the prevalent use of SRM in a wide range of applications.

42 ENGINEERING↗

Genetic Algorithm-Based Commutation Angle Control for Torque Ripple Mitigation in Switched Reluctance Motor Drives

This work addresses the application of the Genetic Algorithm (GA) technique to optimize the commutation angles of a 2 kW 8/6 switched reluctance machine (SRM). The primary goal is to reduce the well-known drawback of SRMs: the torque ripple. Firstly, the machine was modeled in Matlab /Simulink ® using lookup tables obtained via finite element method (FEM) simulations. Subsequently, the model was used to perform the GA routine aiming to find the optimal phase commutation angles that minimize the torque ripple factor. Notably, the torque performance of the SRM was significantly affected by the commutation angles during the search for the optimal solution. Afterwards, the GA results for four different operation points were verified experimentally through a developed drive platform with digital signal processor-based (DSP) control and an asymmetric bridge converter. As showed by the experiments, the proposed approach was suitable to reduce the torque ripple by more than 50% for one of the evaluated operating points. Furthermore, it was confirmed that the torque ripple mitigation led to acoustic noise improvement.

42 ENGINEERING↗

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-phase-noise surface-acoustic-wave oscillator using an edge mode of a phononic band gap

Low-phase-noise microwave-frequency integrated oscillators provide compact solutions for various applications in signal processing, communications, and sensing. Surface acoustic waves (SAWs), featuring orders-of-magnitude shorter wavelength than electromagnetic waves at the same frequency, enable integrated microwave-frequency systems with much smaller footprint on chip. SAW devices also allow higher-quality (Q) factors than electronic components at room temperature. Here, we demonstrate a low-phase-noise gigahertz-frequency SAW oscillator on 128°Y-cut lithium niobate, where the SAW resonator occupies a footprint of 0.05 mm 2 . Leveraging phononic crystal band-gap-edge modes to balance between Q factors and insertion losses, our 1-GHz SAW oscillator features a low phase noise of -132.5 dBc/Hz at a 10-kHz offset frequency and an overlapping Hadamard deviation of 6.5 × 10 -10 at an analysis time of 64 ms. The SAW resonator-based oscillator holds high potential in developing low-noise sensors and acousto-optic integrated circuits.

42 ENGINEERING↗

Improved Bayesian regularization of inverse problems in vibrations and acoustics using noise-only measurements

Here, this paper studies Tikhonov regularization (ridge regression) parameter selection for problems in vibrations and acoustics. The selection method is based on a popular Bayesian method, but it incorporates measurements of sensor noise. The regularization parameter is closely related to the ratio of system input energy to noise energy, so noise measurements inform the inference procedure and improve parameter identification. In cases where standard Bayesian regularization identifies zero as the optimal regularization parameter, noise measurements guarantee a unique nonzero optimum. Sufficient theoretical criteria are developed for this guarantee. The method is verified in even-determined and under-determined configurations in an acoustic source localization simulation and a vibration load identification experiment. It is shown to yield significant improvements over existing empirical Bayesian regularization. Improvements are larger in the even-determined case and smaller in the under-determined case, wherein the inverse solution is less sensitive to the regularization parameter.

42 ENGINEERING↗

Aquifer Monitoring Using Ambient Seismic Noise Recorded With Distributed Acoustic Sensing (DAS) Deployed on Dark Fiber

Abstract Groundwater is a critical resource for human activities worldwide, and a vital component of many natural ecosystems. However, the state and dynamics of water‐bearing aquifers remain uncertain, mostly due to the paucity of subsurface data at high spatial and temporal resolution. Here, we show that analysis of infrastructure‐generated ambient seismic noise acquired on distributed acoustic sensing (DAS) arrays has potential as a tool to track variations in seismic velocities (d v / v ) caused by groundwater level fluctuations. We analyze 5 months of ambient noise acquired along an unused, 23 km‐long telecommunication fiber‐optic cable in the Sacramento Valley, CA, a so‐called “dark fiber." Three array subsections, ∼6 km apart, are processed and the stretching technique is applied to retrieve daily d v / v beneath each location. Near the Sacramento river, d v / v variations in the order of 2%–3% correlate with precipitation events and fluctuations in river stage of ∼1.5 m. In contrast, regions away (2.5 km) from the river do not experience large d v / v variations. These observations reveal short‐scale spatial variability in aquifer dynamics captured by this approach. Dispersion analysis and surface wave inversion of noise gathers reveal that seismic velocity perturbations occur at depths of 10–30 m. Rock physics modeling confirms that observed d v / v are linked to pore pressure changes at these depths, caused by groundwater table fluctuations. Our results suggest that DAS combined with ambient noise interferometry provides a means of tracking aquifer dynamics at high spatial and temporal resolutions at local to regional scales, relevant for effective groundwater resource management.

58 GEOSCIENCES↗

Non-reciprocal acoustoelectric microwave amplifiers with net gain and low noise in continuous operation

Abstract Piezoelectric acoustic devices that are integrated with semiconductors can leverage the acoustoelectric effect, allowing functionalities such as gain and isolation to be achieved in the acoustic domain. This could lead to performance improvements and miniaturization of radio-frequency electronic systems. However, acoustoelectric amplifiers that offer a large acoustic gain with low power consumption and noise figure at microwave frequencies in continuous operation have not yet been developed. Here we report non-reciprocal acoustoelectric amplifiers that are based on a three-layer heterostructure consisting of an indium gallium arsenide (In 0.53 Ga 0.47 As) semiconducting film, a lithium niobate (LiNbO 3 ) piezoelectric film, and a silicon substrate. The heterostructure can continuously generate 28.0 dB of acoustic gain (4.0 dB net radio-frequency gain) for 1 GHz phonons with an acoustic noise figure of 2.8 dB, while dissipating 40.5 mW of d.c. power. We also create a device with an acoustic gain of 37.0 dB (11.3 dB net gain) at 1 GHz with 19.6 mW of d.c. power dissipation and a non-reciprocal transmission of over 55 dB.

42 ENGINEERING↗

Monitoring and flaw detection during wire-based directed energy deposition using in-situ acoustic sensing and wavelet graph signal analysis

The goal of this work is to detect flaw formation in the wire-based directed energy deposition (W-DED) process using in-situ sensor data. The W-DED studied in this work is analogous to metal inert gas electric arc welding. The adoption of W-DED in industry is limited because the process is susceptible to stochastic and environmental disturbances that cause instabilities in the electric arc, eventually leading to flaw formation, such as porosity and suboptimal geometric integrity. Moreover, due to the large size of W-DED parts, it is difficult to detect flaws post-process using non-destructive techniques, such as X-ray computed tomography. Accordingly, the objective of this work is to detect flaw formation in W-DED parts using data acquired from an acoustic (sound) sensor installed near the electric arc. To realize this objective, we develop and apply a novel wavelet integrated graph theory approach. The approach extracts a single feature called graph Laplacian Fiedler number from the noise-contaminated acoustic sensor data, which is subsequently tracked in a statistical control chart. Using this approach, the onset of various types of flaws are detected with a false alarm rate less-than 2%. This work demonstrates the potential of using advanced data analytics for in-situ monitoring of W-DED.

42 ENGINEERING↗