Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AXIAL FLOW COMPRESSOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Detailed Simulations of a Three-Stage Supercritical Carbon Dioxide Axial Compressor with a Focus on the Shrouded Stator Cavities Flow

This paper describes the findings of detailed simulations performed to investigate the impact of seal teeth cavity leakage flow on the aerodynamic and thermal performance of a three-stage supercritical CO 2 axial compressor. The study compares a shrouded stator configuration (with cavities) to a cantilevered stator configuration (without cavities) to highlight their differences. High-fidelity computational fluid dynamics simulations were performed using non-linear harmonic (NLH) and mixing plane assumptions, considering various possible rotor/stator interface configurations for mixing plane calculations. The key performance parameters for each case were compared, and the best-performing configuration selected for further analysis. The individual stage performance parameters are also examined and compared between the cantilevered and shrouded configurations. It was observed that in the shrouded case, the leakage flow enters the cavity downstream of the stator trailing edge and gets entrained into the primary flow upstream of the stator, leading to boundary layer changes at the hub and degradation of stator and downstream rotor performance. Vortical flow structures were also observed in the stator wells, which tended to change the flow angles around the region, thereby affecting mixing and velocity distribution, resulting in a slight deterioration of compressor performance. Additionally, the study examines windage heating due to shear work from rotating walls, including the seal teeth surface. The amount of shear work done on the leakage flow and the corresponding rise in fluid temperature were quantified, tabulated, and further compared with a simple analytical model, showing good agreement between them and, hence, validating the numerical approach used.

42 ENGINEERING↗

Automated Belt Grinding of Axial-Compressor Blades in Gas-Turbine Engines

The finishing of the flow sections of compressor blades is considered. A sequence of operations for this purpose in an automated cycle is proposed. The development of control programs for the grinding of flow sections of the blades is discussed, with allowance for the nonuniform distribution of the margin over the blade surface.

42 ENGINEERING↗

Gas turbine engine with radial diffuser and shortened mid section

An industrial gas turbine engine (10), including: a can annular combustion assembly (80), having a plurality of discrete flow ducts configured to receive combustion gas from respective combustors (82) and deliver the combustion gas along a straight flow path at a speed and orientation appropriate for delivery directly onto the first row (56) of turbine blades (62); and a compressor diffuser (32) having a redirecting surface (130, 140) configured to receive an axial flow of compressed air and redirect the axial flow of compressed air radially outward.

33 ADVANCED PROPULSION SYSTEMS↗

Swirling midframe flow for gas turbine engine having advanced transitions

A gas turbine engine can-annular combustion arrangement (10), including: an axial compressor (82) operable to rotate in a rotation direction (60); a diffuser (100, 110) configured to receive compressed air (16) from the axial compressor; a plenum (22) configured to receive the compressed air from the diffuser; a plurality of combustor cans (12) each having a combustor inlet (38) in fluid communication with the plenum, wherein each combustor can is tangentially oriented so that a respective combustor inlet is circumferentially offset from a respective combustor outlet in a direction opposite the rotation direction; and an airflow guiding arrangement (80) configured to impart circumferential motion to the compressed air in the plenum in the direction opposite the rotation direction.

33 ADVANCED PROPULSION SYSTEMS↗

Large Eddy Simulation of Rotationally Induced Ingress and Egress around an Axial Seal between Rotor and Stator Disks

In gas turbines, the hot gas exiting the combustor can have temperatures as high as 2000 °C, and some of this hot gas enter into the space between the stator and rotor disks (wheelspace). Since the entering hot gas could damage the disks, its ingestion must be minimized. This is carried out by rim seals and by introducing a cooler flow from the compressor (sealing flow) into the wheelspace. Ingress and egress into rim seals are driven by the stator vanes, the rotor and its rotation, and the rotor blades. This study focuses on the ingress and egress driven by the rotor and its rotation. This is carried out by performing wall-resolved large eddy simulation (LES) around an axial seal in a rotor–stator configuration without vanes and blades. Results obtained show the mechanisms by which the rotor and its rotation induce ingress, egress, and flow trajectories. Kelvin–Helmholtz instability was found to create a wavy shear layer and displacement thickness that produces alternating regions of high and low pressures around the rotor side of the seal. Vortex shedding on the backward-facing side of the seal and its impingement on the rotor side of the seal also produces alternating regions of high and low pressures. The locations of the alternating regions of high and low pressures were found to be statistically stationary and to cause ingress to start on the rotor side of the seal. Vortex shedding and recirculating flow in the seal clearance also cause ingress by entrainment. With the effects of the rotor and its rotation on ingress and egress isolated, this study enables the effects of stator vanes and rotor blades to be assessed.

42 ENGINEERING↗

Axial load management system

An axial load management system for a turbomachine including a rotating drivetrain, a thrust bearing assembly, a sensor, and a valve supply line. The rotating drivetrain includes a compressor section and an expander section fluidly coupled together by a closed flowpath. The thrust bearing assembly includes a thrust runner, a thrust bearing housing, and a gas thrust bearing extending between the thrust runner and the thrust bearing housing. Further, the gas thrust bearing supports the rotating drivetrain. The sensor is attached to at least one of the thrust bearing housing or the gas thrust bearing. The valve supply line is fluidly coupled to the closed flowpath. A valve positioned within the valve supply line selectively allows a working fluid to flow between the closed flowpath and a thrust chamber defined by a rotating surface and a fixed surface to modify an axial load on the rotating drivetrain.

42 ENGINEERING↗

Analysis of HolosGen Sub-Scale Simulator with Plant Dynamics Code

The Subcritical Power Module Sub-scale Simulator (SPM-SS) has been designed and constructed by HolosGen LLC under the ARPA-E MEITNER program to simulate the thermal-hydraulic and heat transfer behavior of the full-scale Holos-Quad Subcritical Power Modules (SPMs). Four coupled SPMs, each rated at 5.5MW, form the Holos-Quad gas-cooled microreactor design. The SPM-SS represents a substantially scaled-down system with a power rating less than 40 kW, equipped with an electrically heated fuel cartridge heat exchanger, an electrically heated compressor heat exchanger, and a valve actuated turbine heat exchanger, in addition to a recuperator and a cooler heat exchanger. The fuel cartridge represents a portion of the full-scale SPM core, the compressor heat exchanger mimics the temperature changes resulting from the compressor’s turbomachinery inefficiencies, the turbine heat exchanger mimics the expansion process normally occurring through the turbine, while the recuperator and cooler heat exchangers complete the subscale simulator loop. The heaters equipping the fuel cartridge and the compressor heat exchangers are electronically controlled to simulate normal and off-normal SPM operating conditions. The full-scale Holos-Quad SPM design eliminates the traditional balance of plant and executes thermal-to-electric energy conversion by means of an intercooled Brayton cycle with decoupled compressor-turbine turbomachinery. The Holos-Quad full-scale design is equipped with a multi-stage axial Low- and High-Pressure compressor, and a multistage axial turbine. The SPM-SS is designed for testing and validation of selected components which are instead coupled by a traditional balance of plant. The SPMSS is not equipped with turbo-machinery (compressor and turbine) as the development of these components were excluded from the scope of work under the ARPA-E MEITNER funding program. The SPM-SS balance of plant enables modifications, replacement and testing of individual components with different working fluids and is designed to include the turbo-machinery components that will be developed in future research . The SPM-SS can be operated with different gases, variable mass-flow-rates, pressures, and temperatures to obtain test data for selected components, whose performance can be scaled to validate the computer model of the full-scale SPM at various conditions (e.g., start-up, transients conditions). The SPM-SS can operate at the maximum Holos-Quad design pressure of 7 MPa, and a maximum temperature limited to 650 °C by the electrical heaters. Several SPM-SS tests have been conducted and analyzed with the Plant Dynamics Code (PDC) developed at the Argonne National Laboratory (ANL). These tests aimed at validating the PDC modeled predictions of the full-scale Holos-Quad design with data from selected SPM-SS components. In order to address SPM-SS specific characteristics, such as components heat losses and absence of turbomachinery components, some modifications to the PDC have been implemented to factor the design differences from the full-scale Holos-Quad SPM to the SPM-SS. As the PDC offers capabilities to analyze systems with different working fluids, air, nitrogen, and helium were utilized as the SPM-SS working fluids. Air was utilized to fine-tune the SPM-SS Systems Structures and Components (SSCs), nitrogen was utilized to pressure test the SPM-SS loop at the SPMs design maximum pressure of 7MPa. Helium was utilized as the working fluid circulating through the SPM-SS SSCs for specific tests to validate the PDC predictions of the fuel cartridge heat exchanger. SPM-SS tests data were also analyzed with both the steady-state and transient analysis capabilities offered by the PDC. This report describes the PDC analysis of the SPM-SS tests data, including the necessary code modifications and comparison of the code results with the experimental data. Based on the results, a discussion is presented on how the analysis supports design and transient calculations of the full-scale Holos-Quad microreactor. Also based on the results of this work, recommendations are made for future optimizations of the SPM-SS components and PDC model development needs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Equipment List Comparing Balance of Plant Containing a Heat Pump against a Reference Electricity Generating Plant

Approximately two-thirds of U.S. energy consumption in the industrial and transportation sectors relies on fossil fuels. These sectors require high-quality heat, i.e., thermal energy at very high temperatures, for molecular transformation processes. The Integrated Energy Systems (IES) program aims to assess the economic potential of utilizing nuclear-grade heat from Advanced Reactors (ARs) to meet the high-quality heat demands. By having industrial processes (IPs) supplied with nuclear-generated heat, manufacturers could benefit from more stable and potentially lower energy costs, reducing reliance on volatile fossil fuel markets. The main outcome of the FY24 research was the thermodynamic assessment and gap analysis of steam generation for IP applications. The study completed in June 2024 demonstrated that the required steam temperatures could be achieved by integrating a heat pump into an AR power plant. After identifying the thermal demands of target IPs, multiple balance of plant configurations for the Xe-100 reactor by X-energy, incorporating a heat pump, were analyzed. Their technical feasibilities were assessed, including the design of suitable axial compressors for these applications. Comparative performance analysis showed that thermal efficiency alone is insufficient to evaluate system suitability. To address this, a new indicator (heat factor) was introduced in the report released in September 2024 to quantify the low-quality thermal power needed to produce one unit of high-quality heat for the IP. Results showed that integrating heat pumps into Rankine cycles enables higher steam temperatures, though at the expense of increased thermal energy input. This report builds upon and completes the foundational work previously undertaken. It focuses on the design of two Balance of Plant (BOP) configurations, both based on Rankine energy conversion cycles: “Case 1”, which involves electricity generation only, and “Case 2”, which combines electricity and high-temperature heat generation for industrial use. For each configuration, a comprehensive equipment list was developed, detailing all major components such as turbines, compressors, heat exchangers, pumps, and control systems. These lists will serve as the basis for future comparative cost analyses, with the goal of assessing the number and type of components required to integrate a heat pump into the Rankine cycle and to establish a heat transport system capable of delivering thermal energy from the nuclear plant to an industrial facility. Using the constitutive equations presented in the June 2024 milestone, the operating conditions of all BOP components for both “Case 1” and “Case 2” were evaluated. These parameters—such as temperature, pressure, mass flow rate, and steam quality—served as the basis for calculating the associated thermal and mechanical power flows. The net power required from the heat pump to raise the steam temperature to the target level was also determined. The thermodynamic performance of the configuration was then assessed using the heat factor metric. The key outcome of this analysis is a comparative table that presents the equipment that was used in the “Case 1” and “Case 2” configurations. This study offers a preliminary comparison of the two designs, providing insight into the impact of integrating a heat pump in terms of component requirements and thermal efficiency. This equipment list, together with the evaluated operating conditions, also serves as a foundation for the economic analyses scheduled for the current fiscal year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Laser-produced aluminum plasma expansion inside a plastic plasma envelope

Previous experimental results demonstrated that the plasma pressure decreases with the growing atomic number of the target material. In this context, a question arose if the Al plasma outflow could be collimated using the plastic plasma as a compressor. To solve this problem, an experiment using a plastic target with an Al cylindrical insert was performed. The focal spot diameter substantially larger than that of the insert ensured simultaneous heating both target materials. This experiment proved that a production of Al plasma jets collimated by an action of outer plastic plasma is feasible [Kasperczuk et al., Laser Part. Beams 30, 1 (2012)]. The results of investigations presented here provide additional information on distributions of electron temperature in the outflowing plasma and time and space characteristics of ion emission, both registered at bare and constrained-flow Al targets. The experiment was carried out at the Prague asterix laser system iodine laser facility. The laser provided a 250 ps (full width at half maximum) pulse with the energy of 130 J at the third harmonic frequency ({lambda}{sub 3} = 0.438 {mu}m). A plastic target with an Al cylindrical insert of 400 {mu}m in diameter as well as a bare Al target (for comparison) was used. The focal spot diameter ({Phi}{sub L}) 1200 {mu}m ensured the lateral pressure effect of the plastic plasma strong enough to guarantee the effective Al plasma compression. The electron temperature measurements have shown that such Al plasma compression is accompanied by the increase of its temperature, dominance of which starts at distance of 0.5 mm from the target surface. Measurements of ion emission characteristics confirm the earlier numerical simulation prediction that in these conditions the plasma expansion geometry is closer to planar. The constrained Al plasma jet is very narrow and its axial velocity is considerably larger than the velocity of freely expanding Al plasma stream. It means that the plastic plasma envelope, besides the Al plasma compression, also strongly accelerates the Al plasma in its axial motion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗