Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AUXILIARY HEATING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Fast response of electron-scale turbulence to auxiliary heating cessation in National Spherical Torus Experiment

In this letter, we report the first observation of the fast response of electron-scale turbulence to auxiliary heating cessation in National Spherical Torus eXperiment [Ono et al., Nucl. Fusion 40, 557 (2000)]. The observation was made in a set of RF-heated L-mode plasmas with toroidal magnetic field of 0.55 T and plasma current of 300 kA. It is observed that electron-scale turbulence spectral power (measured with a high-k collective microwave scattering system) decreases significantly following fast cessation of RF heating that occurs in less than 200 μs. The large drop in the turbulence spectral power has a short time delay of about 1–2 ms relative to the RF cessation and happens on a time scale of 0.5–1 ms, much smaller than the energy confinement time of about 10 ms. Power balance analysis shows a factor of about 2 decrease in electron thermal diffusivity after the sudden drop of turbulence spectral power. Measured small changes in equilibrium profiles across the RF cessation are unlikely able to explain this sudden reduction in the measured turbulence and decrease in electron thermal transport, supported by local linear stability analysis and both local and global nonlinear gyrokinetic simulations. The observations imply that nonlocal flux-driven mechanism may be important for the observed turbulence and electron thermal transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air-Source Heat Pumps

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climate conditions. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in northwest United States and one in Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five-seconds, to calculate heat pump's capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides valuable insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving the overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air Source Heat Pumps: Preprint

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climates. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in the northwest United States and one in a Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five seconds, to calculate the heat pump’s capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysing the effects of heating and gas puffing in Proto-MPEX helicon and auxiliary heated plasmas

The Material Plasma Exposure Experiment (MPEX) is being constructed at Oak Ridge National Laboratory to investigate critical fusion reactor issues, such as plasma–material interactions (PMIs) under reactor-relevant conditions and time scales. The linear device Proto-MPEX was used as a test bed to address anticipated research and development issues associated with heating scenarios and establish the physics basis for MPEX. The SOLPS-ITER code suite has been applied to understand plasma and neutral transport in Proto-MPEX and to increase confidence in predictive simulations for MPEX. Coupling between COMSOL and SOLPS is performed to implement a 2D electron heating profile of the helicon source. The simulations show reasonable agreement with the experimental data for plasma with helicon and auxiliary electron cyclotron heating (ECH). Both Bohm and constant diffusion (D$_\perp$: 0.5 m 2 s –1 and $\chi_\perp$: 1 m 2 s –1 ) simulations show similar levels of agreement with respect to the sparse experimental data available, assuming a few per cent impurity concentration. ECH significantly increases the target electron temperature, however, the target electron density is reduced compared to helicon-only heated plasmas due to an increase in flow velocity and radial losses. The simulations show that further increasing the ECH power results in an increase in the target electron density due to increased recycling flux and ionization. The results indicate that ECH significantly enhances the target heat flux, with ECH power of 50 kW increasing the target heat flux from 0.4 to 17 MW m –2 . It is found that a small amount of gas puffing (GP) near the target plate can further increase the target heat fluxes at the higher ECH power cases, but the target heat flux is reduced at higher GP conditions due to a significant reduction in electron temperature via radiation. ECH and GP scenarios can generate a higher target flux, facilitating improved PMI studies with more reactor-relevant plasma conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Auxiliary heating and current drive physics for the ST-E1 fusion power plant

This work describes the physics basis for the proposed auxiliary heating and current drive system on the ST-E1 fusion power plant. The ST-E1 flattop plasma considered here is fully non-inductive with a bootstrap fraction of 0.9 and the remaining current driven by EC waves. Using the recently published physics-based optimization method for EC launchers (Lopez et al 2025 Plasma Phys. Control. Fusion 67 055012), we show that the target flattop ECCD can be achieved with a net efficiency of 52 kA MW −1 using fundamental O-mode (O1) with frequency range 160–200 GHz launched from the low-field side top half of the vacuum vessel (LFS top-launch). From considering two candidate rampup scenarios, we conclude that LFS top-launch O1 ECCD can be equally effective during the early stages of plasma operation, although poloidal steering might be needed. X-mode waves injected from the LFS midplane are also shown to be effective for rampup even when T e < 1 keV. We also present modeling results for the pre-conceptual design of an ICRH system proposed for ST-E1. Using TORIC, we find that an ICRH system aiming for 42–48 MHz and toroidal mode number n φ ~ 10 robustly achieves dominant ion damping via Helium-3 minority heating transitioning to second-harmonic Tritium heating. We then show that such waves can be efficiently generated by a 5-strap traveling-wave antenna (TWA) using the Petra-M code. The TWA has a 40–45 MHz passband within which ~60% of the power entering the TWA is coupled to the plasma with the remaining ~40% of the power being transmitted through the TWA and possibly recirculated; the power reflected back into the transmission lines is negligible. This passband structure persists even when the evanescent distance is increased by a factor of two, or when the magnetic-field angle is increased by 30°, demonstrating inherent load resilience that will be crucial for effective ICRH on ST-E1.

electron cyclotron↗

A novel measurement of marginal Alfven Eigenmode stability during high power auxiliary heating in JET

The interaction of Alfven Eigenmodes (AEs) and energetic particles is one of many important factors determining the success of future tokamaks. In JET, eight in-vessel antennas were installed to actively probe stable AEs with frequencies ranging 25-250 kHz and toroidal mode numbers |n| < 20. During the 2019-2020 deuterium campaign, almost 7500 resonances and their frequencies f0, net damping rates \gamma < 0, and toroidal mode numbers were measured in almost 800 plasma discharges. From a statistical analysis of this database, continuum and radiative damping are inferred to increase with edge safety factor, edge magnetic shear, and when including non-ideal effects. Both stable AE observations and their associated damping rates are found to decrease with |n|. Active antenna excitation is also found to be ineffective in H-mode as opposed to L-mode; this is likely due to the increased edge density gradient's effect on accessibility and ELM-related noise's impact on mode identification. A novel measurement is reported of a marginally stable, edge-localized Ellipticity-induced AE probed by the antennas during high-power auxiliary heating (ICRH and NBI) up to 25 MW. NOVA-K kinetic-MHD simulations show good agreement with experimental measurements of f0, \gamma, and n, indicating the dominance of continuum and electron Landau damping in this case. Similar experimental and computational studies are planned for the recent hydrogen and ongoing tritium campaigns, in preparation for the upcoming DT campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel measurement of marginal Alfvén eigenmode stability during high power auxiliary heating in JET

The interaction of Alfvén eigenmodes (AEs) and energetic particles is one of many important factors determining the success of future tokamaks. In JET, eight in-vessel antennas were installed to actively probe stable AEs with frequencies ranging 25–250 kHz and toroidal mode numbers |n| < 20. During the 2019–2020 deuterium campaign, almost 7500 resonances and their frequencies f 0 , net damping rates γ < 0, and toroidal mode numbers were measured in almost 800 plasma discharges. From a statistical analysis of this database, continuum and radiative damping are inferred to increase with edge safety factor, edge magnetic shear, and when including non-ideal effects. Both stable AE observations and their associated damping rates are found to decrease with |n|. Active antenna excitation is also found to be ineffective in H-mode as opposed to L-mode; this is likely due to the increased edge density gradient’s effect on accessibility and ELM-related noise’s impact on mode identification. A novel measurement is reported of a marginally stable, edge-localized ellipticity-induced AE probed by the antennas during high-power auxiliary heating (ion cyclotron resonance heating and neutral beam injection) up to 25 MW. NOVA-K kinetic-MHD simulations show good agreement with experimental measurements of f 0 , γ, and n, indicating the dominance of continuum and electron Landau damping in this case. Similar experimental and computational studies are planned for the recent hydrogen and ongoing tritium campaigns, in preparation for the upcoming DT campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neoclassical offset toroidal velocity and auxiliary ion heating in tokamaks

In conditions of ideal axisymmetry, for a magnetized plasma in a generic bounded domain, necessarily toroidal, the uniform absorption of external energy (e.g., RF or any isotropic auxiliary heating) cannot give rise to net forces or torques. Experimental evidence on contemporary tokamaks shows that the near central absorption of RF heating power (ICH and ECH) and current drive in presence of MHD activity drives a bulk plasma rotation in the co-I{sub p} direction, opposite to the initial one. Also the appearance of classical or neoclassical tearing modes provides a nonlinear magnetic braking that tends to clamp the rotation profile at the q-rational surfaces. The physical origin of the torque associated with P{sub RF} absorption could be due the effects of asymmetry in the equilibrium configuration or in power deposition, but here we point out also an effect of the response of the so-called neoclassical offset velocity to the power dependent heat flow increment. The neoclassical toroidal viscosity due to internal magnetic kink or tearing modes tends to relax the plasma rotation to this asymptotic speed, which in absence of auxiliary heating is of the order of the ion diamagnetic velocity. It can be shown by kinetic and fluid calculations, that the absorption of auxiliary power by ions modifies this offset proportionally to the injected power thereby forcing the plasma rotation in a direction opposite to the initial, to large values. The problem is discussed in the frame of the theoretical models of neoclassical toroidal viscosity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spheromak Energy Transport Studies via Neutral Beam Injection

Results from the SSPX spheromak experiment provide strong motivation to add neutral beam injection (NBI) heating. Such auxiliary heating would significantly advance the capability to study the physics of energy transport and pressure limits for the spheromak. This LDRD project develops the physics basis for using NBI to heat spheromak plasmas in SSPX. The work encompasses three activities: (1) numerical simulation to make quantitative predictions of the effect of adding beams to SSPX, (2) using the SSPX spheromak and theory/modeling to develop potential target plasmas suitable for future application of neutral beam heating, and (3) developing diagnostics to provide the measurements needed for transport calculations. These activities are reported in several publications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heating performance of a vapor compression heat pump cascaded with a thermoelectric heat pump

Air source heat pumps (ASHPs) are widely utilized for heating and cooling in residential buildings; however, their effectiveness in heating mode is compromised during extreme weather conditions. Extensive research endeavors have been undertaken to develop, test, and assess a cost-effective vapor compression ASHP suitable for cold climate regions. Further, this study takes an innovative approach by developing component and system prototypes for a cold climate heat pump. This design combines a thermoelectric heat pump (TEHP) with a traditional residential split ASHP to augment heating capacity in low ambient temperature conditions. The component and system prototypes underwent experimental testing in the psychrometric chambers. The experimental findings revealed a 13.6% to 13.7% increase in total heat pump heating capacity, accompanied by a 3.1% to 5.0% decrease in the coefficient of performance (COP) at ambient temperatures of -15°C and -19°C, when compared to the original ASHP. The COP of the TEHP is relatively constant, ranging from 1.63 to 1.76. This prototype offers a solution to address the challenges associated with reduced heat pump capacity at low ambient temperatures. The experimental results indicated that the lower the ambient temperature, thermoelectric heat pump auxiliary heating can increase the heating efficiency 60% in comparison to electric resistance.

42 ENGINEERING↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

Research and Development of a New Field Enhanced Low Temperature Thermionic Cathode that Enables Fluorescent Dimming and Loan Shedding without Auxiliary Cathode Heating

This is the final report for project entitled 'Research and development of a new field enhanced low temperature thermionic cathode that enables fluorescent dimming and load shedding without auxiliary cathode heating', under Agreement Number: DE-FC26-04NT-42329. Under this project, a highly efficient CNT based thermionic cathode was demonstrated. This cathode is capable of emitting electron at a current density two order of magnitude stronger then a typical fluorescent cathode at same temperatures, or capable of emitting at same current density but at temperature about 300 C lower than that of a fluorescent cathode. Detailed fabrication techniques were developed including CVD growth of CNTs and sputter deposition of oxide thin films on CNTs. These are mature technologies that have been widely used in industry for large scale materials processing and device fabrications, thus, with further development work, the techniques developed in this project can be scaled-up in manufacturing environment. The prototype cathodes developed in this project were tested in lighting plasma discharge environment. In many cases, they not only lit and sustain the plasma, but also out perform the fluorescent cathodes in key parameters such like cathode fall voltages. More work will be needed to further evaluate more detailed and longer term performance of the prototype cathode in lighting plasma.

30 DIRECT ENERGY CONVERSION↗

Scenario optimization for the tokamak ramp-down phase in RAPTOR: Part A. Analysis and model validation on ASDEX Upgrade

We discuss how the combination of experimental observations and rapid modeling has enabled to improve understanding of the tokamak ramp-down phase in ASDEX Upgrade. A series of dedicated experiments has been performed, to disentangle the effect of individual actuators like plasma current, auxiliary heating and plasma shaping. Optimized discharge termination strategies with increased margin with respect to radiative and vertical stability limits are proposed and tested in experiment. Radiative collapse of the edge $T$ $e$ profile after the HL back-transition is avoided by initially maintaining auxiliary heating during L-mode, showing beneficial effects even after the auxiliary heating is turned off. The capability of the RAPTOR code to model the time evolution of the internal inductance $\ell$ $i3$ has been validated, including the effect of a change in the $I$ $p$ ramp-down rate and the HL transition timing. The reduction of $\ell$ $i3$ caused by rapid compression of the plasma cross-section has been quantitatively recovered in simulations. Successful modeling of the $\ell$ $i3$ time evolution is essential to optimize ramp-down scenarios for future fusion reactors, for which vertical stability and power balance control will be more challenging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The time-dependent simulation of CFETR baseline steady-state scenarios

One of the key issues to achieve the phase I mission of China fusion engineering test reactor (CFETR) is steady-state operation with a modest fusion power up to 200 MW. To examine this feasibility, time-dependent modeling of CFETR baseline scenario is performed. The time-dependent scenario design examines actual discharge features, including auxiliary heating and current drive scheme, equilibrium, transport, PF coil systems and plasma control system during the plasma evolution. During plasma current ramp-up, 10 MW of EC or LH heating is used to effectively save volt–second consumption to a reasonable level within magnet coil capability and to reduce li for better plasma control. Three reference scenarios are designed to target full non-inductive operation with different external heating and current drive (H&CD), which are NB + EC, NB + LH, and LH + EC, respectively. Two scenarios with neutral beams reach the required fusion power of CFETR phase I target, while for LH + EC scenario the fusion power and confinement is somewhat lower. A reversed magnetic shear with q min > 2 is sustained with off-axis current drive and bootstrap current for all cases examined. Ideal MHD analysis shows that both large toroidal mode number n ballooning mode and low n kink mode are stable in the three reference cases independent of whether the current is totally relaxed or not. The L mode and H–L back transition ramp-down are designed to successfully reduce the plasma current to 2 MA and keep li below 2 with ramp-down rate of 80 kA s -1 . The H–L back transition ramp-down yields improvements in the power transfer and coil current evolution as well as the li evolution. The heating and current drive characteristics of three auxiliary heating sources are indicated by scanning studies. A 2D scan of NB energy and tangency radius indicates the features of NB power deposition, current drive, torque and shine through issue. Both ramp-up and flattop are considered in the scanning of radio frequency parameters. For EC waves, the ramp-up phase constrains the parameter space more. The 2D scan of EC launch angle shows that EC waves launched above the midplane yield a better CD efficiency than using a midplane launcher. Specifically, 10 MW of EC waves launched from LFS above the midplane yield a maximum on axis driven current of about 0.55 MA, while waves launched from top yield a maximum near edge driven current of about 0.45 MA in the region of ρ > 0.5. Scanning of n $\parallel$ in LH spectrum shows that n $\parallel$ should be set around 1.7 to get enough penetration (inside ρ = 0.7) for current drive and avoid strong accessibility problem. It is found that LH waves launched from HFS drives more current than that launched from LFS when n $\parallel$ is small. The maximum LH driven current reaches 1.1 MA with 10 MW of LH power launched from HFS.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental study of heating scheme effect on the inner divertor power footprint widths in EAST lower single null discharges

A comprehensive work of the effects of plasma current and heating schemes on divertor power footprint widths is carried out in the experimental advanced superconducting tokamak (EAST). The divertor power footprint widths, i.e., the scrape-off layer heat flux decay length λ q and the heat spreading S, are crucial physical and engineering parameters for fusion reactors. Strong inverse scaling of λ q and S with plasma current have been demonstrated for both neutral beam (NB) and lower hybrid wave (LHW) heated L-mode and H-mode plasmas at the inner divertor target. For plasmas heated by the combination of the two kinds of auxiliary heating schemes (NB and LHW), the divertor power widths tend to be larger in plasmas with higher ratio of LHW power. Comparison between experimental heat flux profiles at outer mid-plane (OMP) and divertor target for NB heated and LHW heated L-mode plasmas reveals that the magnetic topology changes induced by LHW may be the main reason to the wider divertor power widths in LHW heated discharges. The effect of heating schemes on divertor peak heat flux has also been investigated, and it is found that LHW heated discharges tend to have a lower divertor peak heat flux compared with NB heated discharges under similar input power. All these findings seem to suggest that plasmas with LHW auxiliary heating scheme are better heat exhaust scenarios for fusion reactors and should be the priorities for the design of next-step fusion reactors like China Fusion Engineering Test Reactor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preparations for a European R&D roadmap for an inertial fusion demo reactor

A European consortium of 15 laboratories across nine nations have worked together under the EUROFusion Enabling Research grants for the past decade with three principle objectives. These are: (a) investigating obstacles to ignition on megaJoule-class laser facilities; (b) investigating novel alternative approaches to ignition, including basic studies for fast ignition (both electron and ion-driven), auxiliary heating, shock ignition, etc.; and (c) developing technologies that will be required in the future for a fusion reactor. This paperr presents a brief overview of these activities, along with new calculations relates the concept of auxiliary heating of inertial fusion targets, and provides possible future directions of research and development for the updated European Roadmap that is due at the end of 2020. This article is part of a discussion meeting issue ‘Prospects for high gain inertial fusion energy (part 2)’.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solar one - The Delaware solar house and results obtained during the first year of operation

The design of a system which uses CdS/Cu2S solar cells to convert solar energy into electricity and heat, and which uses a heat pump for auxiliary heating and air conditioning is discussed. Salt hydrates are used for heat storage, while air serves as the heat transfer medium. The operational parameters and economic aspects of the system are examined, and preliminary test results are analyzed.

Boeer, K. W.↗