Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ANTICOINCIDENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The UCSD high energy X-ray timing experiment cosmic ray particle anticoincidence detector

The HEXTE, part of the X-Ray Timing Explorer (XTE), is designed to make high sensitivity temporal and spectral measurements of X-rays with energies between 15 and 250 keV using NaI/CsI phoswich scintillation counters. To achieve the required sensitivity it is necessary to provide anticoincidence of charged cosmic ray particles incident upon the instrument, some of which interact to produce background X-rays. The proposed cosmic ray particle anticoincidence shield detector for HEXTE uses a novel design based on plastic scintillators and wavelength-shifter bars. It consists of five segments, each with a 7 mm thick plastic scintillator, roughly 50 cm x 50 cm in size, coupled to two wavelength-shifter bars viewed by 1/2 inch photomultiplier tubes. These segments are configured into a five-sided, box-like structure around the main detector system. Results of laboratory testing of a model segment, and calculations of the expected performance of the flight segments and particle anticoincidence detector system are presented to demonstrate that the above anticoincidence detector system satisfies its scientific requirements.

Hink, P. L.↗

On the determination of iridium in diverse geological samples employing HPGe-coincidence/NaI(Tl)-anticoincidence spectrometry

This paper reports the Ir content of a variety of geological samples determined by the high-purity Ge-coincidence/NaI(Tl)-anticoincidence gamma-ray spectrometry (henceforth referred to as coincidence/anticoincidence technique) and by the conventional INAA. The advantages of this technique are: (1) the Ir content of the samples is obtained (ppm to a fraction of ppb ranges) not only by the 468.1 keV peak as in the conventional INAA but also by the 784.6 keV and 920.9 keV sum peaks, which gives more confidence in the values obtained; and (2) it is well suited for the samples with high Compton background for which it is difficult to measure the Ir content by the conventional INAA technique. The practical sensitivity of this technique depends on the sample matrix. Under present experimental conditions, it varied from 0.1 ng for Mn nodules and 0.004 ng for Libyan Desert Glass. Iridium values obtained on small (about 1 microg) olivine grains demonstrate the potential application of this new technique to microsamples. The principle and methodology of this new technique as well as its advantages and disadvantages over the conventional INAA are discussed.

Murali, A. V.↗

Mercuric Iodide Anticoincidence Shield for Gamma-Ray Spectrometer

A film-growth process was developed for polycrystalline mercuric iodide that creates cost-effective, large-area detectors for high-energy charged-particle detection. A material, called a barrier film, is introduced onto the substrate before the normal mercuric iodide film growth process. The barrier film improves the quality of the normal film grown and enhances the adhesion between the film and the substrate. The films grown using this improved technique were found to have adequate signal-to-noise properties so that individual high-energy charged -particle interactions could be distinguished from noise, and thus, could be used to provide an anticoincidence veto function as desired.

Hartsough, Neal↗

Design, Implementation, and Performance of the Astro-H SXS Calorimeter Array and Anticoincidence Detector

The calorimeter array of the JAXA Astro-H (renamed Hitomi) soft x-ray spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The SXS had a square array of 36 x-ray calorimeters at the focal plane. These calorimeters consisted of ion-implanted silicon thermistors and HgTe thermalizing x-ray absorbers. These devices demonstrated a resolution of better than 4.5 eV at 6 keV when operated at a heat-sink temperature of 50 mK. We will discuss the basic physical parameters of this array, including the array layout, thermal conductance of the link to the heat sink, resistance function, absorber details, and means of attaching the absorber to the thermistor-bearing element. We will also present the thermal characterization of the whole array, including thermal conductance and crosstalk measurements and the results of pulsing the frame temperature via alpha particles, heat pulses, and the environmental background. A silicon ionization detector was located behind the calorimeter array and served to reject events due to cosmic rays. We will briefly describe this anticoincidence detector and its performance.

Kilbourne, Caroline A.↗

Design and Characteristics of the Anticoincidence Detector for the GLAST Large Area Telescope

The Anti-Coincidence Detector (ACD) is the outermost detector layer in the GLAST Large Area Telescope (LAT), surrounding the top and sides of the tracker. The purpose of the ACD is to detect and veto incident cosmic ray charged particles, which outnumber cosmic gamma rays by 3-4 orders of magnitude. The challenge in ACD design is that it must have high (0.9997) detection efficiency for singly charged relativistic particles, but must also have low sensitivity to backsplash particles. These are products of high- energy interactions in the LAT calorimeter. They can cause a veto signal in the ACD, resulting in loss of good gamma-ray events.

Moiseev, A. A.↗

Soft X-ray astronomy proportional counter electronics

The X-ray multiwire proportional counter is designed to measure cosmic X-ray fluxes at sounding rocket altitudes in the energy range of 0.1 to 10 keV. Four instruments will be launched in a Black Brant 4 rocket employing different combinations of detector windows and gas. The detector is constructed with two layers of twelve cells. A columnator is mounted on the face of one layer whose cells are wired together alternately to form two main detector sections. The electronics and gas regulation systems are mounted on the face of the second layer whose cells are wired together to form one anticoincidence detector section. Normally X-rays will have short ionization paths in only one of the main detector cells at a time and won't enter the anticoincidence detector cells. To distinguish between X-rays and charged particles, the instrument includes a coincidence discriminator, an anticoincidence discriminator, and a pulse rise time discriminator.

Gardner, W. R.↗

Techniques for gamma rays.

The detecting systems used in high energy astrophysics are generally more similar to particle detectors than to optical devices. The basic design of the gamma ray instrument depends on whether the energy range is below about 10 MeV and therefore in the region where the Compton effect predominates in the absorption of the gamma-rays, or above that energy where electron-positron pair production is most important. The most usual approach to the detector system in the lower of the two energy intervals is to use a scintillation counter in the center of the detector system to absorb the photons and permit a measure of their energy, and to surround it by another detector which is employed as an active anticoincidence shield to discriminate against charged particles. In the gamma-ray interval above about 10 MeV, the very low flux of gamma rays and the high particle background has directed the development of high energy gamma-ray telescopes towards complicated techniques and large detector arrays. As a result, several investigators have now turned to the spark chamber as the heart of a detector system. Generally, it is surrounded by an anticoincidence system and is triggered by a counter telescope.

Fichtel, C. E.↗

Calibration of large area scintillation counters on cosmic rays

Construction and calibration are reported for a 6-sq m scintillation counter consisting of two pieces of clear Lucite optically joined along a common edge, sixteen squares of plastic scintillator optically coupled on top of the Lucite, and eight photomultiplier tubes for light collection. Calibration of this counter using an anticoincidence counter to exclude multiple particle events is described. Theoretical calculations for purely electromagnetic extensive air showers indicate that this counter should detect an average of 2.5 particles per event, while the calibration data yield about 1.8 particles per event. It is shown that the anticoincidence-counter calibration method must be used for counters with areas of more than a few square meters if calibration on the response from a single particle of an extensive air shower is desired.

Saterlie, S. F.↗

GRIS background reduction results using isotopically enriched Ge

The Gamma Ray Imaging Spectrometer (GRIS) was flown twice from Alice Springs, Australia, in the spring of 1992 for a total of 32 hr at float altitude. One of the seven Ge detectors was isotopically enriched (greater than 97% Ge-70). This was the first time an enriched-Ge detector was used for astrophysical observations. Because of its thick anticoincidence shield, the GRIS instrument background is dominated by internal beta-decay in the energy range of 200-1000 keV. Half of the contribution in this beta-decay 'hump' is due to neutron-activated Ge-74. In this energy range, GRIS observed a factor of 2 reduction in the background in the enriched detector, as predicted. In future instruments (e.g., INTEGRAL), with thicker anticoincidence shields and smaller apertures, the background reduction will be even larger. Three strong instrumental background lines (54, 67, and 139 keV) are also eliminated. The elimination of the first two is particularly important for cylotron line observations.

Barthelmy, S. D.↗

Development of a Broad High-Energy Gamma-Ray Telescope using Silicon Strip Detectors

The research effort has led to the development and demonstration of technology to enable the design and construction of a next-generation high-energy gamma-ray telescope that operates in the pair-production regime (E greater than 10 MeV). In particular, the technology approach developed is based on silicon-strip detector technology. A complete instrument concept based on this technology for the pair-conversion tracker and the use of CsI(T1) crystals for the calorimeter is now the baseline instrument concept for the Gamma-ray Large Area Space Telescope (GLAST) mission. GLAST is NASA's proposed high-energy gamma-ray mission designed to operate in the energy range from 10 MeV to approximately 300 GeV. GLAST, with nearly 100 times the sensitivity of EGRET, operates through pair conversion of gamma-rays and measurement of the direction and energy of the resulting e (+) - e (-) shower. The baseline design, developed with support from NASA includes a charged particle anticoincidence shield, a tracker/converter made of thin sheets of high-Z material interspersed with Si strip detectors, a CsI calorimeter and a programmable data trigger and acquisition system. The telescope is assembled as an array of modules or towers. Each tower contains elements of the tracker, calorimeter, and anticoincidence system. As originally proposed, the telescope design had 49 modules. In the more optimized design that emerged at the end of the grant period the individual modules are larger and the total number in the GLAST array is 25. Also the calorimeter design was advanced substantially to the point that it has a self-contained imaging capability, albeit much cruder than the tracker.

Michelson, Peter F.↗

CdZnTe Background Measurements at Balloon Altitudes with PoRTIA

Measurements of the CdZnTe internal background at balloon altitudes are essential to determine which physical processes make the most important background contributions. We present results from CdZnTe background measurements made by PoRTIA, a small CdZnTe balloon instrument that was flown three times in three different shielding configurations. PoRTIA was passively shielded during its first flight from Palestine, Texas and actively shielded as a piggyback instrument on the GRIS balloon experiment during its second and third flights from Alice Springs, Australia, using the thick GRIS Nal anticoincidence shield. A significant CdZnTe background reduction was achieved during the third flight with PoRTIA placed completely inside the GRIS shield and blocking crystal, and thus completely surrounded by 15 cm of Nal. A unique balloon altitude background data set is provided by CdZnTe and Ge detectors simultaneously surrounded by the same thick anticoincidence shield; the presence of a single coxial Ge detector inside the shield next to PoRTIA allowed a measurement of the ambient neutron flux inside the shield throughout the flight. These neutrons interact with the detector material to produce isomeric states of the Cd, Zn and Te nuclei that radiatively decay; calculations are presented that indicate that these decays may explain most of the fully shielded CdZnTe background.

Parsons, A.↗

XL-Calibur - a second-generation balloon-borne hard X-ray polarimetry mission

XL-Calibur is a hard X-ray (15-80 keV) polarimetry mission operating from a stabilised balloon-borne platform in the stratosphere. It builds on heritage from the X-Calibur mission, which observed the accreting neutron star GX 301−2 from Antarctica, between December 29th 2018 and January 1st 2019. The XL-Calibur design incorporates an X-ray mirror, which focusses X-rays onto a polarimeter comprising a beryllium rod surrounded by Cadmium Zinc Telluride (CZT) detectors. The polarimeter is housed in an anticoincidence shield to mitigate background from particles present in the stratosphere. The mirror and polarimeter-shield assembly are mounted at opposite ends of a12 m long lightweight truss, which is pointed with arcsecond precision by WASP – the Wallops Arc Second Pointer. TheXL-Calibur mission will achieve a substantially improved sensitivity over X-Caliburby using a larger effective area X-ray mirror, reducing background through thinner CZT detectors, and improved anticoincidence shielding. When observing a 1 Crab source for t(day) days, the Minimum Detectable Polarisation (at 99% confidence level) is∼2%·t−1/2day. The energy resolution at 40 keV is∼5.9 keV. The aim of this paper is to describe the design and performance of the XL-Calibur mission, as well as the foreseen science programme.

Q Abarr↗

Digital system provides superregulation of nanosecond amplifier-discriminator circuit

Feedback system employing a digital logic comparator to detect and correct amplifier drift provides stable gain characteristics for nanosecond amplifiers used in counting applications. Additional anticoincidence logic enables application of the regulation circuit to the amplifier and discriminator while they are mounted in an operable circuit.

Forges, K. G.↗

The Measurement of Radiation Exposure of Astronauts by Radiochemical Techniques

The principal gamma-ray-omitting radioisotopes produced in the body of astronauts by cosmic-ray bombardment which have half-lives long enough to be useful for radiation dose evaluation are Be-7, Na-22, and Na-24. The sodium isotopes were measured in the preflight and postflight urine and feces, and those feces specimens collected during the manned Apollo missions, by analysis of the urine salts and the raw feces in large crystal multidimensional gamma-ray spectrometers. The Be-7 was chemically separated, and its concentration measured in an all Na(T1), anticoincidence shielded, scintillation well crystal. The overall sensitivity of the experiment was reduced by almost all variables such as low concentrations of excreted cosmogenic radionuclides, high concentrations of injected radionuclides, low sample sizes, long delay periods before analysis, and uncertain excretion rates. The astronaut radiation dose in millirads, as determined by this technique, for the Apollo 7, 8, 9, 10, 11, 12, and 13 missions was 330, 160, 315, 870 ? 550, 31, 110, and 250 respectively. In view of these limitations this technique would be best applied to cases of unusually high exposures, such as that encountered from solar flares.

R L Brodzinski↗

The measurement of radiation exposure of astronauts by radiochemical techniques

The principal gamma-ray emitting radioisotopes, produced in the body of astronauts by cosmic-ray bombardment, which have half-lives long enough to be useful for radiation dose evaluation, are Be-7, Na-22, and Na-24. The sodium isotopes were measured in the preflight and postflight urine and feces, and those feces specimens collected during the manned Apollo missions, by analysis of the urine salts and the raw feces in large crystal multidimensional gamma-ray spectrometers. The Be-7 was chemically separated, and its concentration measured in an all NaI (TL), anticoincidence shielded, scintillation well crystal. The astronaut radiation dose in millirads, as determined for the Apollo 7, 8, 9, 10, 11, 12, and 13 missions, was 330, 160, smaller than 315, 870 plus or minus 550, 31, 110, and smaller than 250, respectively.

Brodzinski, R. L.↗

The MIT OSO-7 X-ray experiment. A five color survey of the positions and time variations of cosmic X-ray sources

The all-sky, X-ray measurements are made in five broad energy bands from 0.5 to 60 keV with X-ray collimators of one and three degree FWHM response. Working with the onboard star sensor source locations may be determined to a precision of plus or minus 0.1 deg. The experiment is located in wheel compartment number three of the spacecraft. A time division logic system divides each wheel rotation into 256 data bins in each of which X-ray counts are accumulated over a 190 second interval. Measurement chain circuits include provision for both geometric and risetime anticoincidence. A detailed description of the instrument is included as is pertinent operating information.

Taylor, R. S.↗

Advanced technical developments in support of scientific experiments in space

A technique was developed for preparing solid state, lithium-drifted silicon detectors. Hollow cylindrical detectors were built and tested for possible use as anticoincidence shields to replace conventional plastic scintillators and photomultipliers. A fission cell was developed for the Pioneer F/G instruments and the IMP I subsystem. An electron current detector was developed for Jovian belt measurements of electron flux. A number of circuits and semiconductor devices was also developed.

Lamport, J. E.↗