The UCSD high energy X-ray timing experiment cosmic ray particle anticoincidence detector

The HEXTE, part of the X-Ray Timing Explorer (XTE), is designed to make high sensitivity temporal and spectral measurements of X-rays with energies between 15 and 250 keV using NaI/CsI phoswich scintillation counters. To achieve the required sensitivity it is necessary to provide anticoincidence of charged cosmic ray particles incident upon the instrument, some of which interact to produce background X-rays. The proposed cosmic ray particle anticoincidence shield detector for HEXTE uses a novel design based on plastic scintillators and wavelength-shifter bars. It consists of five segments, each with a 7 mm thick plastic scintillator, roughly 50 cm x 50 cm in size, coupled to two wavelength-shifter bars viewed by 1/2 inch photomultiplier tubes. These segments are configured into a five-sided, box-like structure around the main detector system. Results of laboratory testing of a model segment, and calculations of the expected performance of the flight segments and particle anticoincidence detector system are presented to demonstrate that the above anticoincidence detector system satisfies its scientific requirements.

Hink, P. L.↗

Development of a TES based Cryo-Anticoincidence for a large array of microcalorimeters

The employment of large arrays of microcalorimeters in space missions (IXO, EDGE/XENIA), requires the presence of an anticoincidence detector to remove the background due to the particles, with a rejection efficiency at least equal to Suzaku (98%). A new concept of anticoincidence is under development to match the very tight thermal requirements and to simplify the design of the electronic chain. The idea is to produce a Cryo-AntiCoincidence (Cryo-AC) based on a silicon absorber and read by a TES (Transition-Edge Sensor). This configuration would ensure very good performances in terms of efficiency, time response and signal to noise ratio. We present the results of estimations, simulations and preliminary measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anticoincidence analysis for radioxenon detection

A number of beta-gamma coincidence detectors have been deployed for monitoring nuclear explosions. When 133Xe is present in a sample it causes interference in the calculation of the metastable isotopes. Therefore, an alternative method for activity quantification is to analyze the anticoincidence spectrum of the plastic detector to decrease interference from 133Xe. Simulated and experimental measurements were tested. The results show that the anticoincidence analysis produces more accurate results when quantifying the activity of 131mXe but is sometimes limited by the background increasing the minimum detectable activity.

Sivels, Ciara B.↗

Efficiency Of Charged-Particle Detection with Scintillation-Detector Prototype for the Anticoincidence System of the Signal Experiment

The results obtained by measuring the efficiency of detection of charged particles (atmospheric muons) for a prototype of a polyvinyltoluene-based scintillation detector being created for the anticoincidence system of the Signal experiment on board the Interhelioprobe spacecraft are presented. These measurements rely on determining the ratio of the numbers of triple and double coincidences of pulses that arise as atmospheric muons traverse the detector system.

43 PARTICLE ACCELERATORS↗

Light dark matter constraints from SuperCDMS HVeV detectors operated underground with an anticoincidence event selection

This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g−days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/𝑐 2 , as well as upper limits on dark photon kinetic mixing and axionlike particle axioelectric coupling for masses between 1.2 and 23.3 eV/𝑐 2 . Compared to an earlier HVeV search, sensitivity was improved as a result of an increased overburden of 225 meters of water equivalent, an anticoincidence event selection, and better pile-up rejection. In the case of dark-matter-electron scattering via a heavy mediator, an improvement by up to a factor of 25 in cross section sensitivity was achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the microcalorimeter and anticoincidence detector for the Line Emission Mapper x-ray probe

The Line Emission Mapper (LEM) is an x-ray probe mission concept that is designed to provide unprecedented insight into the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. LEM incorporates a light-weight x-ray optic with a large-format microcalorimeter array. The LEM detector utilizes a 14k pixel array of transition-edge sensors (TESs) that will provide <2.5 eV spectral resolution over the energy range 0.2 to 2 keV, along with a field-of-view of 30 arcmin. The microcalorimeter array and readout builds upon the technology developed for the European Space Agency’s (ESA’s) Athena/x-ray Integral Field Unit. Here, we present a detailed overview of the base- line microcalorimeter design, its performance characteristics, including a detailed energy resolution budget and the expected count-rate capability. In addition, we outline the current status and plan for continued technology maturation. Behind the LEM array sits a high-efficiency TES-based anticoincidence (antico) detector that will reject cosmic-ray background events. We will briefly describe the design of the antico and plan for continued development.

47 OTHER INSTRUMENTATION↗

On the determination of iridium in diverse geological samples employing HPGe-coincidence/NaI(Tl)-anticoincidence spectrometry

This paper reports the Ir content of a variety of geological samples determined by the high-purity Ge-coincidence/NaI(Tl)-anticoincidence gamma-ray spectrometry (henceforth referred to as coincidence/anticoincidence technique) and by the conventional INAA. The advantages of this technique are: (1) the Ir content of the samples is obtained (ppm to a fraction of ppb ranges) not only by the 468.1 keV peak as in the conventional INAA but also by the 784.6 keV and 920.9 keV sum peaks, which gives more confidence in the values obtained; and (2) it is well suited for the samples with high Compton background for which it is difficult to measure the Ir content by the conventional INAA technique. The practical sensitivity of this technique depends on the sample matrix. Under present experimental conditions, it varied from 0.1 ng for Mn nodules and 0.004 ng for Libyan Desert Glass. Iridium values obtained on small (about 1 microg) olivine grains demonstrate the potential application of this new technique to microsamples. The principle and methodology of this new technique as well as its advantages and disadvantages over the conventional INAA are discussed.

Murali, A. V.↗

Mercuric Iodide Anticoincidence Shield for Gamma-Ray Spectrometer

A film-growth process was developed for polycrystalline mercuric iodide that creates cost-effective, large-area detectors for high-energy charged-particle detection. A material, called a barrier film, is introduced onto the substrate before the normal mercuric iodide film growth process. The barrier film improves the quality of the normal film grown and enhances the adhesion between the film and the substrate. The films grown using this improved technique were found to have adequate signal-to-noise properties so that individual high-energy charged -particle interactions could be distinguished from noise, and thus, could be used to provide an anticoincidence veto function as desired.

Hartsough, Neal↗

Design, Implementation, and Performance of the Astro-H SXS Calorimeter Array and Anticoincidence Detector

The calorimeter array of the JAXA Astro-H (renamed Hitomi) soft x-ray spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The SXS had a square array of 36 x-ray calorimeters at the focal plane. These calorimeters consisted of ion-implanted silicon thermistors and HgTe thermalizing x-ray absorbers. These devices demonstrated a resolution of better than 4.5 eV at 6 keV when operated at a heat-sink temperature of 50 mK. We will discuss the basic physical parameters of this array, including the array layout, thermal conductance of the link to the heat sink, resistance function, absorber details, and means of attaching the absorber to the thermistor-bearing element. We will also present the thermal characterization of the whole array, including thermal conductance and crosstalk measurements and the results of pulsing the frame temperature via alpha particles, heat pulses, and the environmental background. A silicon ionization detector was located behind the calorimeter array and served to reject events due to cosmic rays. We will briefly describe this anticoincidence detector and its performance.

Kilbourne, Caroline A.↗

The Simbol-X Anticoincidence

The Simbol-X telescope will be constitued by two satellites in formation flight. One will host the mirror module and the other the detector payload. This payload will be built with two main detectors able to measure the position, energy and arrival time of each focused photon, between 0.5 and 80 keV. The high sensitivity required by Simbol-X will necessitate low noise background detectors. To achieve this goal, those detectors will be surrounded by a passive graded shield, aimed to stop the out of field of view photons, and an active anticoiencidence system to tag the passing particles. This anticoiencidence detector, whose conception, optimisation and realization are under responsibility of the APC Laboratory, Paris, is based on plastic scintillator plates associated to multi-anodes photo-multipliers via optical fibers. In this paper, we will present the present status of the anticoiencidence system and its expected performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Characteristics of the Anticoincidence Detector for the GLAST Large Area Telescope

The Anti-Coincidence Detector (ACD) is the outermost detector layer in the GLAST Large Area Telescope (LAT), surrounding the top and sides of the tracker. The purpose of the ACD is to detect and veto incident cosmic ray charged particles, which outnumber cosmic gamma rays by 3-4 orders of magnitude. The challenge in ACD design is that it must have high (0.9997) detection efficiency for singly charged relativistic particles, but must also have low sensitivity to backsplash particles. These are products of high- energy interactions in the LAT calorimeter. They can cause a veto signal in the ACD, resulting in loss of good gamma-ray events.

Moiseev, A. A.↗

Soft X-ray astronomy proportional counter electronics

The X-ray multiwire proportional counter is designed to measure cosmic X-ray fluxes at sounding rocket altitudes in the energy range of 0.1 to 10 keV. Four instruments will be launched in a Black Brant 4 rocket employing different combinations of detector windows and gas. The detector is constructed with two layers of twelve cells. A columnator is mounted on the face of one layer whose cells are wired together alternately to form two main detector sections. The electronics and gas regulation systems are mounted on the face of the second layer whose cells are wired together to form one anticoincidence detector section. Normally X-rays will have short ionization paths in only one of the main detector cells at a time and won't enter the anticoincidence detector cells. To distinguish between X-rays and charged particles, the instrument includes a coincidence discriminator, an anticoincidence discriminator, and a pulse rise time discriminator.

Gardner, W. R.↗

Observation of cosmic ray hadrons at the top of the Sierra Negra volcano in Mexico with the SciCRT prototype

In this work we report the flux of protons and neutral emission measured at the top of the Sierra Negra volcano at 4600 m.a.s.l. (575 g/cm2), in Eastern Mexico. As an example of the capability of the mini-SciCR as a cosmic ray detector we present the Forbush decrease recorded on March 7, 2012. These data were obtained with a cosmic ray detector prototype called mini-SciCR that was operating from October 2010 to July 2012. Our main aims were to measure the hadronic component flux of the secondary cosmic ray and to show the appropriate performance of all system of the detector. To separate the signals of protons from other charged particles we obtained the energy deposition pattern when they cross the detector using a Monte Carlo simulation, and to separate the signals of neutral emission we used an anticoincidence system between the edge bars and the internal bars of the detector. The mini-SciCR is a prototype of a new cosmic ray detector called SciBar Cosmic Ray Telescope (SciCRT) installed in the same place, which is in the process of calibration. The SciCRT will work mainly as a Solar Neutron and Muon Telescope, it is designed to achieve: (1) larger effective area than the current Solar Neutron Telescope, (2) higher energy resolution to determine the energy spectrum of solar neutrons, (3) lower energy threshold, and (4) higher particle identification ability.

58 GEOSCIENCES↗

Techniques for gamma rays.

The detecting systems used in high energy astrophysics are generally more similar to particle detectors than to optical devices. The basic design of the gamma ray instrument depends on whether the energy range is below about 10 MeV and therefore in the region where the Compton effect predominates in the absorption of the gamma-rays, or above that energy where electron-positron pair production is most important. The most usual approach to the detector system in the lower of the two energy intervals is to use a scintillation counter in the center of the detector system to absorb the photons and permit a measure of their energy, and to surround it by another detector which is employed as an active anticoincidence shield to discriminate against charged particles. In the gamma-ray interval above about 10 MeV, the very low flux of gamma rays and the high particle background has directed the development of high energy gamma-ray telescopes towards complicated techniques and large detector arrays. As a result, several investigators have now turned to the spark chamber as the heart of a detector system. Generally, it is surrounded by an anticoincidence system and is triggered by a counter telescope.

Fichtel, C. E.↗

Calibration of large area scintillation counters on cosmic rays

Construction and calibration are reported for a 6-sq m scintillation counter consisting of two pieces of clear Lucite optically joined along a common edge, sixteen squares of plastic scintillator optically coupled on top of the Lucite, and eight photomultiplier tubes for light collection. Calibration of this counter using an anticoincidence counter to exclude multiple particle events is described. Theoretical calculations for purely electromagnetic extensive air showers indicate that this counter should detect an average of 2.5 particles per event, while the calibration data yield about 1.8 particles per event. It is shown that the anticoincidence-counter calibration method must be used for counters with areas of more than a few square meters if calibration on the response from a single particle of an extensive air shower is desired.

Saterlie, S. F.↗

GRIS background reduction results using isotopically enriched Ge

The Gamma Ray Imaging Spectrometer (GRIS) was flown twice from Alice Springs, Australia, in the spring of 1992 for a total of 32 hr at float altitude. One of the seven Ge detectors was isotopically enriched (greater than 97% Ge-70). This was the first time an enriched-Ge detector was used for astrophysical observations. Because of its thick anticoincidence shield, the GRIS instrument background is dominated by internal beta-decay in the energy range of 200-1000 keV. Half of the contribution in this beta-decay 'hump' is due to neutron-activated Ge-74. In this energy range, GRIS observed a factor of 2 reduction in the background in the enriched detector, as predicted. In future instruments (e.g., INTEGRAL), with thicker anticoincidence shields and smaller apertures, the background reduction will be even larger. Three strong instrumental background lines (54, 67, and 139 keV) are also eliminated. The elimination of the first two is particularly important for cylotron line observations.

Barthelmy, S. D.↗

Development of a Broad High-Energy Gamma-Ray Telescope using Silicon Strip Detectors

The research effort has led to the development and demonstration of technology to enable the design and construction of a next-generation high-energy gamma-ray telescope that operates in the pair-production regime (E greater than 10 MeV). In particular, the technology approach developed is based on silicon-strip detector technology. A complete instrument concept based on this technology for the pair-conversion tracker and the use of CsI(T1) crystals for the calorimeter is now the baseline instrument concept for the Gamma-ray Large Area Space Telescope (GLAST) mission. GLAST is NASA's proposed high-energy gamma-ray mission designed to operate in the energy range from 10 MeV to approximately 300 GeV. GLAST, with nearly 100 times the sensitivity of EGRET, operates through pair conversion of gamma-rays and measurement of the direction and energy of the resulting e (+) - e (-) shower. The baseline design, developed with support from NASA includes a charged particle anticoincidence shield, a tracker/converter made of thin sheets of high-Z material interspersed with Si strip detectors, a CsI calorimeter and a programmable data trigger and acquisition system. The telescope is assembled as an array of modules or towers. Each tower contains elements of the tracker, calorimeter, and anticoincidence system. As originally proposed, the telescope design had 49 modules. In the more optimized design that emerged at the end of the grant period the individual modules are larger and the total number in the GLAST array is 25. Also the calorimeter design was advanced substantially to the point that it has a self-contained imaging capability, albeit much cruder than the tracker.

Michelson, Peter F.↗

CdZnTe Background Measurements at Balloon Altitudes with PoRTIA

Measurements of the CdZnTe internal background at balloon altitudes are essential to determine which physical processes make the most important background contributions. We present results from CdZnTe background measurements made by PoRTIA, a small CdZnTe balloon instrument that was flown three times in three different shielding configurations. PoRTIA was passively shielded during its first flight from Palestine, Texas and actively shielded as a piggyback instrument on the GRIS balloon experiment during its second and third flights from Alice Springs, Australia, using the thick GRIS Nal anticoincidence shield. A significant CdZnTe background reduction was achieved during the third flight with PoRTIA placed completely inside the GRIS shield and blocking crystal, and thus completely surrounded by 15 cm of Nal. A unique balloon altitude background data set is provided by CdZnTe and Ge detectors simultaneously surrounded by the same thick anticoincidence shield; the presence of a single coxial Ge detector inside the shield next to PoRTIA allowed a measurement of the ambient neutron flux inside the shield throughout the flight. These neutrons interact with the detector material to produce isomeric states of the Cd, Zn and Te nuclei that radiatively decay; calculations are presented that indicate that these decays may explain most of the fully shielded CdZnTe background.

Parsons, A.↗