Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ANODE PLANE ARRAYS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

ProtoDUNE Anode Plane Assembly

ProtoDUNE is a test bed for the Deep Underground Neutrino Experiment, an international physics project hosted at the Department of Energy's Fermilab. One of the ProtoDUNE detectors, which are being constructed at CERN, is a single-phase neutrino detector that uses liquid argon. It will require a number of anode plane arrays, special panels made of wire, to detect the signature of a neutrino interaction in the argon bath. This is a glimpse into the process of fabricating these planes, some of which are being created at the University of Wisconsin-Madison. Learn more about the ProtoDUNE detectors here: https://www.symmetrymagazine.org/article/the-biggest-little-detectors

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Demonstration and performance of an online data selection algorithm for liquid argon time projection chambers using MicroBooNE

The MicroBooNE detector is a liquid argon time projection chamber (LArTPC) that produces three-dimensional images of particle interactions using ionization charge collected by anode wire plane arrays and scintillation light collected by a light detection system. In addition to testing long-standing experimental neutrino anomalies and performing measurements of neutrino interactions with argon nuclei using the Fermilab Booster Neutrino Beam, MicroBooNE aims to develop methodologies for rare beyond the Standard Model and off-beam physics searches. Looking ahead to the upcoming Deep Underground Neutrino Experiment (DUNE), with MicroBooNE serving as a valuable testbed, achieving high sensitivity and livetime for off-beam physics while satisfying data processing and storage constraints will require data-driven, intelligent, and online or real-time data selection techniques. These techniques are essential for reducing data rates and preserving rare signals with high accuracy. In this paper, we describe a fast data selection algorithm suitable for online execution to identify electrons from stopping cosmic ray muons in the MicroBooNE detector utilizing ionization charge information, and present its performance. This represents the first demonstration of online data selection in a LArTPC using real data and charge information exclusively and provides an important proof-of-principle for applying such techniques to other LArTPC experiments such as the Short-Baseline Near Detector and DUNE.

Abratenko, P. [Tufts U. (main)]↗

CdZnTe Image Detectors for Hard-X-Ray Telescopes

Arrays of CdZnTe photodetectors and associated electronic circuitry have been built and tested in a continuing effort to develop focal-plane image sensor systems for hard-x-ray telescopes. Each array contains 24 by 44 pixels at a pitch of 498 m. The detector designs are optimized to obtain low power demand with high spectral resolution in the photon- energy range of 5 to 100 keV. More precisely, each detector array is a hybrid of a CdZnTe photodetector array and an application-specific integrated circuit (ASIC) containing an array of amplifiers in the same pixel pattern as that of the detectors. The array is fabricated on a single crystal of CdZnTe having dimensions of 23.6 by 12.9 by 2 mm. The detector-array cathode is a monolithic platinum contact. On the anode plane, the contact metal is patterned into the aforementioned pixel array, surrounded by a guard ring that is 1 mm wide on three sides and is 0.1 mm wide on the fourth side so that two such detector arrays can be placed side-by-side to form a roughly square sensor area with minimal dead area between them. Figure 1 shows two anode patterns. One pattern features larger pixel anode contacts, with a 30-m gap between them. The other pattern features smaller pixel anode contacts plus a contact for a shaping electrode in the form of a grid that separates all the pixels. In operation, the grid is held at a potential intermediate between the cathode and anode potentials to steer electric charges toward the anode in order to reduce the loss of charges in the inter-anode gaps. The CdZnTe photodetector array is mechanically and electrically connected to the ASIC (see Figure 2), either by use of indium bump bonds or by use of conductive epoxy bumps on the CdZnTe array joined to gold bumps on the ASIC. Hence, the output of each pixel detector is fed to its own amplifier chain.

Chen, C. M. Hubert↗

Thermal Neutron Imaging Using A New Pad-Based Position Sensitive Neutron Detector

Thermal neutrons (with mean energy of 25 meV) have a scattering mean free path of about 20 m in air. Therefore it is feasible to find localized thermal neutron sources up to ~30 m standoff distance using thermal neutron imaging. Coded aperture thermal neutron imaging was developed in our laboratory in the nineties, using He-3 filled wire chambers. Recently a new generation of coded-aperture neutron imagers has been developed. In the new design the ionization chamber has anode and cathode planes, where the anode is composed of an array of individual pads. The charge is collected on each of the individual 5x5 mm2 anode pads, (48x48 in total, corresponding to 24x24 cm2 sensitive area) and read out by application specific integrated circuits (ASICs). The high sensitivity of the ASICs allows unity gain operation mode. The new design has several advantages for field deployable imaging applications, compared to the previous generation of wire-grid based neutron detectors. Among these are the rugged design, lighter weight and use of non-flammable stopping gas. For standoff localization of thermalized neutron sources a low resolution (11x11 pixel) coded aperture mask has been fabricated. Using the new larger area detector and the coarse resolution mask we performed several standoff experiments using moderated californium and plutonium sources at Idaho National Laboratory. In this paper we will report on the development and performance of the new pad-based neutron camera, and present long range coded-aperture images of various thermalized neutron sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The GCT camera for the Cherenkov Telescope Array

The Gamma Cherenkov Telescope (GCT) is one of the designs presented for the Small Sized Telescope (SST) section of the Cherenkov Telescope Array (CTA). The GCT uses dual-mirror optics, resulting in a compact telescope with good image quality and a large field of view with a smaller, more economical, camera than is achievable with conventional single mirror solutions. The photon counting GCT camera is designed to record the flashes of atmospheric Cherenkov light from gamma and cosmic ray initiated cascades, which last only a few tens of nanoseconds. The GCT optics require that the camera detectors follow a convex surface with a radius of curvature of 1 m and a diameter of ~35 cm, which is approximated by tiling the focal plane with 32 modules. The initial camera prototype is equipped with multi-anode photomultipliers, each comprising an 8×8 array of 6×6 mm 2 pixels to provide the required angular scale, adding up to 2048 pixels in total. Detector signals are shaped, amplified and digitised by electronics based on custom ASICs that provide digitisation at 1 GSample/s. The camera is self-triggering, retaining images where the focal plane light distribution matches predefined spatial and temporal criteria. The electronics are housed in the liquid-cooled, sealed camera enclosure. LED flashers at the corners of the focal plane provide a calibration source via reflection from the secondary mirror. The first GCT camera prototype underwent preliminary laboratory tests last year. In November 2015, the camera was installed on a prototype GCT telescope (SST-GATE) in Paris and was further used to successfully record the first Cherenkov light of any CTA prototype, and the first Cherenkov light seen with such a dual-mirror optical system. A second full-camera prototype based on Silicon Photomultipliers is under construction. Up to 35 GCTs are envisaged for CTA.

47 OTHER INSTRUMENTATION↗

Performance characteristics of a curved-channel microchannel plate with a curved input face and a plane output face

The presently performance-evaluated format, in which a high-gain curved-channel microchannel plate (M2MCP) has a spherical concave input face and a plane output face, allows the input face of the MCP (1) to match such curved focal surfaces as that of a Rowland-circle spectrometer mounting, while (2) having a high-resolution plane readout array in proximity focus with the output face. This MCP has been evaluated in a discrete-anode multicathode microchannel array detector system. The saturated modal gain was found to be inversely proportional to the length/diameter ratio of the channels and directly proportional to the applied MCP voltage.

Slater, David C.↗

Roughness of Ti Substrates for Control of the Preferred Orientation of TiO 2 Nanotube Arrays as a New Orientation Factor

We report the surface roughness of a Ti substrate as a critical factor for controlling the degree of the preferred orientation of anatase TiO2 nanotube arrays (NTAs) which are synthesized by anodization and a subsequent annealing process. The degree of the preferred orientation to the (004) plane of the anatase crystal structure has a strong dependency on the root-mean-square roughness (Sq) of the initial Ti substrate when the roughness-controlled substrates are anodized in an ethylene glycol-based electrolyte containing ~2 wt % of water. Highly preferred oriented NTAs were obtained from low-Sq (<10 nm) substrates, which were accompanied by uniform pore distribution and low concentration of hydroxyl ions in as-anodized amorphous NTAs. The mechanism of the preferred oriented crystallization of nanometer-scaled tube walls is explained considering the microscopic geometrical uniformity of the oxide barrier and nanopores at the early stage of anodization, which affected the local electric field and thus the insertion of the hydroxyl group into the amorphous TiO2 tube walls.

14 SOLAR ENERGY↗

Capacitively coupled pickup in MCP-based photodetectors using a conductive metallic anode

We have designed and tested a robust 20×20 cm 2 thin metal film internal anode capacitively coupled to an external array of signal pads or micro-strips for use in fast microchannel plate photodetectors. The internal anode, in this case a 10 nm-thick NiCr film deposited on a 96% pure Al 2 O 3 3 mm-thick ceramic plate and connected to HV ground, provides the return path for the electron cascade charge. The multi-channel pickup array consists of a printed-circuit card or glass plate with metal signal pickups on one side and the signal ground plane on the other. The pickup can be put in close proximity to the bottom outer surface of the sealed photodetector, with no electrical connections through the photodetector hermetic vacuum package other than a single ground connection to the internal anode. Two pickup patterns were tested using a small commercial MCP-PMT as the signal source: 1) parallel 50 Ω 25-cm-long micro-strips with an analog bandwidth of 1.5 GHz, and 2) a 20×20 cm 2 array of 2-dimensional square ‘pads’ with sides of 1.27 cm or 2.54 cm. The rise-time of the fast input pulse is maintained for both pickup patterns. For the pad pattern, we observe 80% of the directly coupled amplitude. For the strip pattern we measure 34% of the directly coupled amplitude on the central strip of a broadened signal. The physical decoupling of the photodetector from the pickup pattern allows easy customization for different applications while maintaining high analog bandwidth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Landsat 9: Status and Plans

The Landsat 9 mission, currently under development and proceeding towards a targeted launch in late 2020, will be very similar to the Landsat 8 mission, launched in 2013. Like Landsat 8, Landsat 9 is a joint effort between NASA and USGS with two sensors, the Operational Land Imager 2 (OLI-2), essentially a copy of the OLI on Landsat 8 and the Thermal Infrared Sensor 2 (TIRS-2), very similar to the TIRS on Landsat 8. The OLI-2, like OLI, provides 14-bit image data, though for Landsat 9, all 14 bits will be retained and transmitted to the ground. The focal plane modules to be used for OLI-2 were flight spares for OLI and are currently being retested by Ball Aerospace. Results indicate radiometric performance comparable to OLI. The TIRS was a class C instrument, with a 3-year design lifetime, and therefore had limited redundancy. TIRS-2 will be a class B instrument, with a 5-year design lifetime, like OLI (and OLI-2), necessitating design changes to increase redundancy. The stray light and Scene Select Mechanism (SSM) encoder problems observed on orbit with TIRS have also instigated a few design changes to TIRS-2. Stray light analysis and testing have indicated that additional baffles in the TIRS-2 optical system will suppress the out-of-field response. The SSM encoder problems have not been definitively traced to a route cause, though conductive anodic filament growth in the circuit boards is suspected. Improved designs for the encoder are being considered for TIRS-2. The spare Focal Plane Array (FPA) from TIRS is planned for use in TIRS-2; FPA spectral and radiometric performance testing is scheduled for September of this year at NASA's Goddard Space Flight Center.

Landsat↗

Larger sized wire arrays on 1.5 MA Z-pinch generator

Experiments on the UNR Zebra generator with Load Current Multiplier (LCM) allow for implosions of larger sized wire array loads than at standard current of 1 MA. Advantages of larger sized planar wire array implosions include enhanced energy coupling to plasmas, better diagnostic access to observable plasma regions, and more complex geometries of the wire loads. The experiments with larger sized wire arrays were performed on 1.5 MA Zebra with LCM (the anode-cathode gap was 1 cm, which is half the gap used in the standard mode). In particular, larger sized multi-planar wire arrays had two outer wire planes from mid-atomic-number wires to create a global magnetic field (gmf) and plasma flow between them. A modified central plane with a few Al wires at the edges was put in the middle between outer planes to influence gmf and to create Al plasma flow in the perpendicular direction (to the outer arrays plasma flow). Such modified plane has different number of empty slots: it was increased from 6 up to 10, hence increasing the gap inside the middle plane from 4.9 to 7.7 mm, respectively. Such load configuration allows for more independent study of the flows of L-shell mid-atomic-number plasma (between the outer planes) and K-shell Al plasma (which first fills the gap between the edge wires along the middle plane) and their radiation in space and time. We demonstrate that such configuration produces higher linear radiation yield and electron temperatures as well as advantages of better diagnostics access to observable plasma regions and how the load geometry (size of the gap in the middle plane) influences K-shell Al radiation. In particular, K-shell Al radiation was delayed compared to L-shell mid-atomic-number radiation when the gap in the middle plane was large enough (when the number of empty slots was increased up to ten)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

FELIX-Based Readout of the Single-Phase ProtoDUNE Detector

Large liquid argon (LAr) time projection chambers (TPCs) have been adopted for the Deep Underground Neutrino Experiment (DUNE) experiment's far detector, which will be composed of four 17-kton detectors situated 1.5 km underground at the Sanford Underground Research Facility. This represents a large increase in scale compared to existing experiments. Both single- and dual-phase technologies will be validated at CERN, in cryostats capable of accommodating full-size detector modules, and exposed to low-energy charged particle beams. This program, called ProtoDUNE, also allows for extensive tests of data acquisition strategies. The Front-End LInk eXchange (FELIX) readout system was initially developed within the ATLAS collaboration and is based on custom field-programmable gate array (FPGA)-based Peripheral Component Interconnect Express input/output cards, connected through point-to-point links to the detector front end and hosted in commodity servers. FELIX will be used in the single-phase ProtoDUNE setup to read the data coming from 2560 anode wires organized in a single anode plane assembly (APS) structure. With a continuous readout at a sampling rate of 2 MHz, the system must deal with an input rate of 96 Gb/s. An external trigger will preselect time windows of 5 ms with interesting activity expected inside the detector. Event building will occur for triggered events, at a target rate of 25 Hz; the readout system will form fragments from the data samples matching the time window, carry out lossless compression, and forward the data to event building nodes over 10-Gb/s Ethernet. This paper discusses the design and implementation of this readout system as well as the first operational experience.

47 OTHER INSTRUMENTATION↗

Speckle spectroscopy; an application for the multi-anode microchannel array detector system

Plans to combine the High Angular Resolution Imager/Spectrometer on the 4-meter Mayall telescope at the Kitt Peak National Observatory and the (256 x 1024)-pixel Multi-Anode Microchannel Array detector system to produce a unique instrument for speckle spectroscopy are described. The pulse-counting detector system will provide distortion-free imaging and will time tag each spatially-resolved photon event with an accuracy of 100 ns. The Imager/Spectrometer will provide a spatial resolution of 0.07 arcsec orthogonal to the plane of dispersion and 0.18 arcsec in the plane of dispersion.

Butcher, H. R.↗

Performance of an Array of 6 X 6 X 20 mm3 Virtual Frisch-Grid CdZnTe Detectors With A Waveform Sampling Readout System

Arrays of CdZnTe (CZT) bars with high spatial and energy resolution are an enabling technology for future space missions, such as the image plane detector of the Galactic Explorer with a Coded Aperture Mask Compton Telescope (GECCO). GECCO will explore the medium-energy (100 keV – 10 MeV) gamma-ray sky, which is among the least covered windows to the Universe with a massive potential for discovery. We have integrated an array of 6x6x20 mm3 virtual Frisch-grid (VFG) CZT detectors, measuring signals from the cathodes, anodes, and pads on each of the four sides of each bar. The VFG CZT detector is read out with an IDEAS GDS-100 waveform sampling readout system to optimize the signal processing and event reconstruction. We evaluated the energy and position resolution of the integrated VFG CZT array with a 137Cs source and successfully demonstrated better than 1% energy resolution and finer than 1 mm position resolution at 662 keV. Furthermore, we carried out a beam test at the High Intensity Gamma-ray Source (HIGS) at Duke University to investigate the performance of the system for higher energy gamma-rays. Together with the basic performance obtained from the 137Cs source, we present here those results from the beam test with various gamma-ray energies up to 8 MeV.

Makoto Sasaki↗

Preparing magnetic yttrium iron garnet nanodot arrays by ultrathin anodic alumina template on silicon substrate

Ultrahigh density periodically ordered magnetic yttrium iron garnet (Y{sub 3}Fe{sub 5}O{sub 12}, YIG) nanodot arrays have been prepared by pulsed laser deposition through an ultrathin alumina mask (UTAM). UTAM having periodically ordered circularly shaped holes with 350 nm in diameter, 450 nm in inter-pore distance, and 700 nm in height has been prepared on silicon substrate. Furthermore, the microstructure and magnetic properties of YIG nanodot arrays have been characterized. Nanodot arrays with a sharp distribution in diameter centered at 340 nm with standard deviation of 10 nm have been fabricated. Moreover, typical hysteresis loops and ferromagnetic resonance spectra in in-plane and out-of-plane revealed that this unique structure greatly influences the magnetics properties of YIG. First, coercivity of YIG nanodot arrays in in-plane was increased about from 15 Oe of YIG films to 500 Oe. Then, the degree of uniformity about nanodot height decided that two or more resonance peaks in out-of-plane were detected in the spectra. The peak-to-peak linewidth values were about 94 Oe and 40 Oe in the parallel and perpendicular directions, respectively, which indicated that the values were larger by the two-magnon scattering. Consequently, this pattering method creates opportunities for studying physics in oxide nanomagnets and may be applied in spin-wave devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mathematical modeling of novel porous transport layer architectures for proton exchange membrane electrolysis cells

Thin foil based porous transport layers (PTLs) that contain highly structured pore arrays have shown promise as anode PTLs in proton exchange membrane electrolysis cells. These novel PTLs, fabricated with advanced manufacturing techniques, produce thin, tunable, multifunctional layers with reduced flow and interfacial resistances and high thermal and electric conductivities. To further optimize their design, it is important to understand their fundamental impact on the transport of protons, electrons, and liquid/vapor mixtures in the electrode. In this work, we develop a two-dimensional multiphysics model to simulate the coupled electrochemistry and multiphase transport in an electrolysis cell operated with the novel PTL architecture. The results show that larger pores improve access of water to the anode catalyst layer, which is beneficial for both the oxygen evolution reaction and membrane hydration. Larger pore sizes also improve oxygen gas transport from the catalyst layer, because generated oxygen gas is forced to travel in-plane through the anode catalyst layer until it reaches a pore opening that is connected to a channel. The discussed results confirm that the proposed thin foil based PTLs are fundamentally different from conventional PTLs, such as felts or layered meshes. The model developed in this work also provides generalizable insight into fundamental PEMEC phenomena, such as the competition between liquid and gas phase transport, membrane hydration and water management, and nonuniform electrochemical reactions, which are processes relevant to all PEMEC designs.

25 ENERGY STORAGE↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

Simple, Compact, High-Resolution Monochromatic X-Ray Source for Characterization of X-Ray Calorimeter Arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

M A Leutenegger↗

Testing of an Arcjet Thruster with Capability of Direct-Drive Operation

Electric thrusters typically require a power processing unit (PPU) to convert the spacecraft provided power to the voltage-current that a thruster needs for operation. Testing has been initiated to study whether an arcjet thruster can be operated directly with the power produced by solar arrays without any additional conversion. Elimination of the PPU significantly reduces system-level complexity of the propulsion system, and lowers developmental cost and risk. The work aims to identify and address technical questions related to power conditioning and noise suppression in the system and heating of the thruster in long-duration operation. The apparatus under investigation has a target power level from 400-1,000 W. However, the proposed direct-drive arcjet is potentially a highly scalable concept, applicable to solar-electric spacecraft with up to 100's of kW and beyond. A direct-drive electric propulsion system would be comprised of a thruster that operates with the power supplied directly from the power source (typically solar arrays) with no further power conditioning needed between those two components. Arcjet thrusters are electric propulsion devices, with the power supplied as a high current at low voltage; of all the different types of electric thruster, they are best suited for direct drive from solar arrays. One advantage of an arcjet over Hall or gridded ion thrusters is that for comparable power the arcjet is a much smaller device and can provide more thrust and orders of magnitude higher thrust density (approximately 1-10 N/sq m), albeit at lower I(sub sp) (approximately 800-1000 s). In addition, arcjets are capable of operating on a wide range of propellant options, having been demonstrated on H2, ammonia, N2, Ar, Kr, Xe, while present SOA Hall and ion thrusters are primarily limited to Xe propellant. Direct-drive is often discussed in terms of Hall thrusters, but they require 250-300 V for operation, which is difficult even with high-voltage solar arrays. The arcjet requires under 100 V, which is more in-line with what is easily possible with a solar array. Direct-drive of an electric propulsion system confers the advantage of reducing or eliminating the power processing unit (PPU) that is typically needed to convert the spacecraft-provided power to the voltage and current needed for thruster operation. Since the PPU is typically the most expensive piece of an electric thruster system, from both a fabrication and qualification standpoint, its elimination offers the potential for major reductions in system cost and risk. The design of the arcjet built for this effort was based on previous low power (1 kW class) arcjets. It has a precision machined 99.95% pure tungsten anode which also serves as the nozzle. The anode constrictor region is 1 mm (0.040-in) diameter and 1 mm (0.040-in) long. The cathode is a tungsten welding electrode doped with LaO2; its tip was precision ground to a 30◦ angle ending in a blunt end. The two electrodes are separated by a boron-nitride insulator which also serves as the propellant injection manifold; it ends in six small holes which introduce the propellant gas in the diverging section of the nozzle, directly adjacent to the cathode. The electrodes and insulator are housed in a stainless-steel outer-body, with a Macor insulator at the mid-plane to provide thermal isolation between the front and back halves of the device. The gas seals were made using Grafoil gaskets. Figure 1A shows the assembled thruster in the vacuum chamber; figure 1B shows the thruster in operation on argon at a flow rate of 676 sccm (20 mg/s). Initial testing was conducted in a 3.5-ft diameter vacuum chamber; the ultimate pressure reached during quasi-steady operation of the thruster was about 330 millitorr. The thruster was powered with a high-current, 0-100A, 15 kW power supply. The discharge was initiated with a high-voltage (approximately 10 kV) spark initiator that was isolated from the supply by a stack of diodes. The testing indicated that an operating point exists within the I-V characteristics that is compatible with direct-drive solar-electric operation; for a flow rate of 20 mg/s (argon) the arc could be sustained at a voltage of about 20 V and a current of 25 A (500W).

Martin, Adam K.↗