Engineering PapersSearch

SEARCH · Engineering Papers

Results for “ANESTHETICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Concentrations of anesthetics across the water-membrane interface; the Meyer-Overton hypothesis revisited

The free energies of transferring a variety of anesthetic and nonanesthetic compounds across water-oil and water-membrane interfaces were obtained using computer simulations. Anesthetics exhibit greatly enhanced concentrations at these interfaces, compared to nonanesthetics. The substitution of the interfacial solubilites of the anesthetics for their bulk lipid solubilities in the Meyer-Overton relation, was found to give a better correlation, indicating that the potency of an anesthetic is directly proportional to its solubility at the interface.

NASA Center ARC

Anesthetic Concerns of Space Flight

Anesthesiologists are acutely aware of the fact that, although a given surgical procedure may be relatively simple, the required anesthetic care is, in certain cases, extremely complex. This principle is particularly evident when one ponders the difficulties involved in providing even basic anesthetic care in microgravity. In this issue some of these difficulties through the evaluation of airway management techniques during water immersion are confronted, a simulation of the gravito-inertial conditions of space flight. As prelude for this paper, I would like to outline some of the challenges to be overcome before surgical, anesthetic, and critical care can be delivered beyond our home planet.

Norfleet, William T.

Interactions of anesthetics with the water-hexane interface. A molecular dynamics study

The free energy profiles characterizing the transfer of nine solutes across the liquid-vapor interfaces of water and hexane and across the water-hexane interface were calculated from molecular dynamics simulations. Among the solutes were n-butane and three of its halogenated derivatives, as well as three halogenated cyclobutanes. The two remaining molecules, dichlorodifluoromethane and 1,2-dichloroperfluoroethane, belong to series of halo-substituted methanes and ethanes, described in previous studies (J. Chem. Phys. 1996, 104, 3760; Chem. Phys. 1996, 204, 337). Each series of molecules contains structurally similar compounds that differ greatly in anesthetic potency. The accuracy of the simulations was tested by comparing the calculated and the experimental free energies of solvation of all nine compounds in water and in hexane. In addition. the calculated and the measured surface excess concentrations of n-butane at the water liquid-vapor interface were compared. In all cases, good agreement with experimental results was found. At the water-hexane interface, the free energy profiles for polar molecules exhibited significant interfacial minima, whereas the profiles for nonpolar molecules did not. The existence of these minima was interpreted in terms of a balance between the free energy contribution arising from solute-solvent interactions and the work to form a cavity that accommodates the solute. These two contributions change monotonically, but oppositely, across the interface. The interfacial solubilities of the solutes, obtained from the free energy profiles, correlate very well with their anesthetic potencies. This is the case even when the Meyer-Overton hypothesis, which predicts a correlation between anesthetic potency and solubility in oil, fails.

NASA Center ARC

Interactions of anesthetics with the membrane-water interface

Although the potency of conventional anesthetics correlates with lipophilicity, an affinity to water also is essential. It was recently found that compounds with very low affinities to water do not produce anesthesia regardless of their lipophilicity. This finding implies that clinical anesthesia might arise because of interactions at molecular sites near the interface of neuronal membranes with the aqueous environment and, therefore, might require increased concentrations of anesthetic molecules at membrane interfaces. As an initial test of this hypothesis, we calculated in molecular dynamics simulations the free energy profiles for the transfer of anesthetic 1,1,2-trifluoroethane and nonanesthetic perfluoroethane across water-membrane and water-hexane interfaces. Consistent with the hypothesis, it was found that trifluoroethane, but not perfluoroethane, exhibits a free energy minimum and, therefore, increased concentrations at both interfaces. The transfer of trifluoroethane from water to the nonpolar hexane or interior of the membrane is accompanied by a considerable, solvent-induced shift in the conformational equilibrium around the C-C bond.

NASA Center ARC

Challenges Encountered Using Ophthalmic Anesthetics in Space Medicine

On orbit, ophthalmic anesthetics are used for tonometry and off-nominal corneal examinations. Proparacaine has been flown traditionally. However, the manufacturers recently changed its storage requirements from room temperature storage to refrigerated storage to preserve stability and prolong the shelf-life. Since refrigeration on orbit is not readily available and there were stability concerns about flying proparacaine unrefrigerated, tetracaine was selected as an alternative ophthalmic anesthetic in 2013. We will discuss the challenges encountered flying and using these anesthetics on the International Space Station.

Bayuse, T.

Test monkeys anesthetized by routine procedure

Test monkeys are safely anesthetized for five minutes by confining them for less than six minutes in enclosures containing a controlled volume of ether. Thus the monkeys can be properly and safely positioned on test couches and fitted with electrodes or other devices prior to physiological tests.

Source record

Operating Room Environment Control. Part A: a Valve Cannister System for Anesthetic Gas Adsorption. Part B: a State-of-the-art Survey of Laminar Flow Operating Rooms. Part C: Three Laminar Flow Experiments

An anesthetic gas flow pop-off valve canister is described that is airtight and permits the patient to breath freely. Once its release mechanism is activated, the exhaust gases are collected at a hose adapter and passed through activated coal for adsorption. A survey of laminar air flow clean rooms is presented and the installation of laminar cross flow air systems in operating rooms is recommended. Laminar flow ventilation experiments determine drying period evaporation rates for chicken intestines, sponges, and sections of pig stomach.

Meyer, J. S.

Comparative study of choleretic agents in anesthetized rats as well as in restrained and and unrestrained rats, with or without compensation for biliary loss

Tests were conducted on Wistar rats by using 3 control choleretic agents: 1-phenyl-1-hydroxy n-pentane, dehydrocholic acid, and phenyl-dimethylacetic acid. The effects of these agents were compared in different experimental conditions. The comparative study of choleretic agents in anesthetized rats, in restrained and unrestrained rats, with or without compensation for biliary loss by the biliary secretion of restrained or unrestrained rats does not show, in systematic pharmecodynamic investigations, an obvious superiority over the methods based on the simple technique.

Labrid, C.

Cardiopulmonary responses to acute hypoxia, head-down tilt and fluid loading in anesthetized dogs

Cardiopulmonary responses to acute hypoxia (HY), fluid loading by saline infusion (FL), and head-down tilt (HD) of mechanically ventilated anesthetized dogs were investigated by measuring thermodynamics and pulmonary gas exchange. It was found that HD decreased the total respiratory compliance both during HY and normoxia (NO) and that the reduction in compliance by FL was twice as large as by HD. Superimposing HD on HY doubled the increase in vascular resistance due to HY alone. In the systemic circulation, HD lowered the resistance to below NO levels. There was a significant positive correlation between the changes in blood volume and in pulmonary artery pressure for experimental transitions, suggesting that a shift in blood volume from systemic to pulmonary circulations and changes in the total blood volume may contribute substantially to these apparent changes in resistance.

Loeppky, J. A.

Anteroventral Third Ventricle Lesions Attenuate Pressor Responses to Serotonin in Anesthetized Rats

When administered intravenously, serotonin (5-hydroxytryptamine; 5-HT) evokes a triphasic blood pressure response, consisting of the Bezold-Jarisch-associated depressor response, a pressor action, and long-lasting depressor response. Because the pressor response may, in part, be caused by central nervous system (CNS) activation by 5-HT, we predicted that destruction of the anteroventral third ventricle (AV3V) region, an area rich in 5-HT receptors, would attenuate increases in blood pressure to intravenous 5-HT. In anesthetized sham-lesioned and AV3V-lesioned Sprague-Dawley rats. we measured mean arterial pressure (MAP), heart rate (HR), and lumbar sympathetic nerve activity (SNA) to increasing bolus doses of intravenous 5-HT (1, 2.5, 5, 10, 25 microg/kg), before and after blockade of bradycardia using methylatropine (200 microg/kg). In all rats, bolus injections of 5-HT elicited bradycardia accompanied by a fall in lumbar SNA and an initial hypotension followed by a pressor response and a longer lasting hypotensive response. The bradycardia, reduction in lumbar SNA, and both depressor responses were equivalent in sham-lesioned and AV3V-lesioned groups. Importantly, AV3V lesions attenuated pressor responses to increasing doses of 5-HT (3 +/- 1, 6 +/- 4, 6 +/- 4, 17 +/- 4, 35 +/- 3 mmHg) compared to sham-lesioned controls (6 +/- 3, 16 +/- 7, 33 +/- 5, 54 +/- 4, 51 +/- 6 mmHg; P < 0.0001). This attenuation was conserved following blockade of bradycardia with methylatropine (P < 0.01). In summary, pressor responses to intravenous 5-HT are diminished by AV3V lesions. These data indicate that the pressor component of the blood pressure response to intravenous 5-HT is partly dependent upon interaction with the CNS.

Muntzel, Martin S.

Mechanisms for vasopressin effects on intraocular pressure in anesthetized rats

Continuous intracameral infusions of a balanced salt solution (0.175 microliter min-1) have been reported to raise intraocular pressure (IOP) in anesthetized rats. Palm et al. (1995) previously reported that this effect was attenuated significantly by inclusion of arginine-vasopressin (AVP, 10 ng 0.175 microliter-1) in the infusate. This study used experimental and computer simulation methods to investigate factors underlying these changes in IOP. First, constant intracameral infusions of artificial cerebrospinal fluid (aCSF) at different fixed rates (0.049-0.35 microliter min-1) were used to estimate the outflow resistance. Secondly, IOP responses were measured during an 2 hr intracameral infusion of either aCSF or AVP that was the sum of a small constant component (0.05 microliter min-1) and a larger periodic component (0.25 microliter min-1, cycling for 4 min on, then 4 min off); the mean infusion rate was 0.175 microliter min-1. As shown previously for 0.175 microliter min-1 constant infusions, the periodic aCSF infusion induced a significant rise in IOP that was attenuated by AVP administration. Complex demodulation analysis and the estimated gain parameter of a second order transfer function fit to the periodic responses indicated that outflow resistance increased significantly during the infusions in both aCSF and AVP groups, but that the indices of resistance did not differ significantly between aCSF and AVP infused eyes. This finding implies that changes in outflow resistance do not explain the difference in IOP responses to intracameral aCSF and AVP. The two responses differed significantly, though, in damping factors, such that the aCSF responses were considerably more underdamped than the AVP responses. It is hypothesized that aCSF-induced increase in IOP reflects both (1) a small component reflecting increased outflow resistance and (2) a larger non-resistive component. Since the non-resistive component is insensitive to pretreatment with acetazolamide, it is suggested that the aCSF-induced elevation in IOP reflects primarily vascular perfusion changes that are reduced by local vasoconstrictor actions of AVP. The latter mechanism likely maintains vascular perfusion of the globe when intraocular hypertension develops.

NASA Discipline Cardiopulmonary

Effects of angiotensin, vasopressin and atrial natriuretic peptide on intraocular pressure in anesthetized rats

The effects of atrial natriuretic peptide (ANP), vasopressin (AVP) and angiotensin (ANG) on blood and intraocular pressures of pentobarbital anesthetized rats were evaluated following intravenous, intracerebroventricular or anterior chamber routes of administration. Central injections did not affect intraocular pressure. Equipressor intravenous infusions of ANG raised, whereas AVP decreased, intraocular pressure. Direct infusions of a balanced salt solution (0.175 microliter/min) raised intraocular pressure between 30 and 60 min. Adding ANG or ANP slightly reduced this solvent effect but AVP was markedly inhibitory. An AVP-V1 receptor antagonist reversed the blunting of the solvent-induced rise by the peptide, indicating receptor specificity. Acetazolamide pretreatment lowered intraocular pressure, but the solvent-induced rise in intraocular pressure and inhibition by AVP still occurred without altering the temporal pattern. Thus, these effects appear unrelated to aqueous humor synthesis rate. The data support the possibility of intraocular pressure regulation by peptides acting from the blood and aqueous humor.

NASA Discipline Number 14-10