Engineering PapersSearch

SEARCH · Engineering Papers

Results for “AMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The development and evolution of biological AMS at Livermore: a perspective

Biological accelerator mass spectrometry (AMS) provides ultrasensitive carbon-14 isotopic analysis enabling a deeper understanding of human health concerns by enabling quantification of pharmacokinetics and other molecular endpoints directly in humans. It enables environmentally and human relevant studies of metabolic pathways through the use of very low concentrations of labeled metabolic substrates in cells and organisms. Here, we discuss why AMS is an important tool for the biosciences, the development and evolution of biological AMS at Livermore and discuss technical refinements that will improve the efficiency of operation for the measurement of ultra-trace levels of 14 C, which, long term, will enable greater ease of use and sample throughput.

47 OTHER INSTRUMENTATION

Measurement of AmLi Sources for Active Well Coincidence Counter

To support the use of the Oak Ridge National Laboratory (ORNL) large-volume active well coincidence counter (LV-AWCC) in material control and accountancy (MC&A) measurements, a set of AmLi neutron sources was acquired from Savannah River National Laboratory (SRNL). These sources were measured to verify their suitability for use in the ORNL LV-AWCC. The sources produce neutrons at a rate that is within 4% of the rate for one set of AmLi sources already in use and 40% higher than the rate for the other set. These measurements indicate that the SRNL sources are suitable for use in the LV-AWCC because their sensitivity and measurement precision will be similar to those of the sets already in use. However, the SRNL sources still need to be evaluated for MC&A use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

AMS Joint/Bilateral Surveys

A historical presentation depicting the International Joint Aerial Surveys AMS has co-created and collaborative efforts that were implemented as result of those efforts.

61 RADIATION PROTECTION AND DOSIMETRY

AmeriFlux US-AMS Argonne Testbed for Multiscale Observational Science (ATMOS)

This is the AmeriFlux version of the carbon flux data for the site US-AMS Argonne Testbed for Multiscale Observational Science (ATMOS). Site Description - This tower is located at Argonne National Laboratory approximately 2 km north of the Des Plaines river and 115 m NNW from the ATMOS meteorological tower. It is downwind of a seasonally wet grassland bordered by forest 40 m N of the flux tower. The area was managed by controlled burns until 2019.

McNicol, Gavin [University of Illinois at Chicago]

Resolving Mixtures of Soot Characterized by SP-AMS Spectra Using a Latent Dirichlet Allocation Model

Soot produced by detonation or combustion events exhibits different chemical properties depending on the fuel, device construction, and environmental conditions in which the event occurs. These properties can be useful for defining relevant signatures for probabilistically identifying the different types of events that occurred, based on the soot that is produced from these events. However, it is rare to observe samples of soot from a detonation or combustion that are not contaminated by outside particles. In this paper, we present a method for resolving mixtures of soot to determine the contributions of sources that may be present in samples of recovered soot. We use Latent Dirichlet Allocation to describe the generative process for a sample of recovered soot, and use Variational Bayesian Inference to learn about the parameters associated with the generative model. We demonstrate the utility of this method by considering real samples of mixtures of soot under various frameworks to show that the model is able to identify the different components present in a sample of soot as well as their mixing proportions.

54 ENVIRONMENTAL SCIENCES

Changes in atmospheric circulation amplify extreme snowfall fueled by Arctic sea ice loss over high-latitude land

Arctic sea-ice retreat has been linked to increased winter precipitation and heavy snowfall over land, likely due to a combination of enhanced evaporation from ice-free Arctic marginal seas (AMS) and changes in atmospheric circulation. However, their relative roles and contributions remain uncertain. Here, we show that a greater proportion of AMS evaporative moisture reached high-latitude land during the cold seasons from 1980–1989 to 2012–2021. Atmospheric circulation changes added an additional 13 % increase in the AMS moisture contribution, accounting for 11 % of the total increase in AMS-sourced land precipitation. Notably, 46 % of the increase in AMS-sourced extreme snowfall is attributed to circulation-driven landward moisture transport, representing an 84 % increase beyond the effect of enhanced AMS evaporation alone. Further analysis indicates that both the rise in Arctic moisture and the atmospheric circulation shifts are primarily driven by anthropogenic forcing. These findings highlight how atmospheric circulation changes amplify extreme snowfall fueled by AMS evaporation, underscoring the synergistic effects of Arctic sea ice loss and circulation change on high-latitude winter precipitation.

Anthropogenic forcing

National User Resource for Biological Accelerator Mass Spectrometry (Final Report)

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science. As a NIGMS National Resource the National User Resource for Biological Accelerator Mass Spectrometry will help NIH funded scientists achieve a deeper understanding of the etiology of human health concerns by (1) enabling the quantification of pharmacokinetics and other molecular endpoints directly in humans; (2) offering the ability to conduct quantitative studies using biologics such as proteins or lipids, and thereby reducing the amount of radioisotope usage in biomedical labs; and (3) enabling more relevant studies of metabolic pathways in health and disease through the use of much lower, more biologically-relevant, concentrations of metabolic substrates in cells and intact organisms. Such studies support NIGMS’s basic biomedical research areas that contribute to the understanding of fundamental cellular and physiological principles and enable research supported by the Biophysics, Biomedical Technology, and Computational Biosciences (BBCB); Genetics and Molecular, Cellular, and Developmental Biology (GMCDB); Pharmacology, Physiology, Biological Chemistry (PPBC) and Training, Workforce Development, and Diversity (TWD) Divisions. Over the next five years, our goals are to: 1. Improve the efficiency of operation for AMS measurements through installation of new interfaces to our AMS systems, technical modifications to improve gas accepting ion source efficiency and upgrading our data analysis software for improved ease of use and data reporting. 2. Increase the accessibility and visibility of ultra-sensitive 14C measurements for the biomedical research community by training of new investigators and expanding our national user base. 3. Provide high throughput, ultra-sensitive 14C analysis for the NIGMS and NIH user community.

47 OTHER INSTRUMENTATION

Producing 236 U reference standards for Accelerator Mass Spectrometry at the University of Notre Dame

36 U is a rare isotope of uranium, naturally occurring in ores with an abundance of 236 U/ 238 U$<$ 1 x 10 -9 . The ability to detect it and make isotopic ratio measurements has applications ranging from nuclear forensics and nonproliferation to energy production and environmental protection. Currently, Accelerator Mass Spectrometry (AMS) is the only technique sensitive enough to accurately measure 236 U/ 238 U isotopic ratios as they exist in naturally occurring ores in the range of 236 U/ 238 U = 10 -12 $-$ 10 -9 . Some AMS facilities have demonstrated their capabilities to make these measurements. Historically, the lack of commercially available reference standards covering the range of naturally occurring 236 U/ 238 U abundances has necessitated the use of absolute measurements, notoriously difficult to do using AMS, resulting in increased uncertainties in measurements and a reliance on knowledge of systematic effects. To mitigate these issues, various AMS facilities have sought to develop their own reference standards. Using a reference standard prepared for other forms of mass spectrometry, a series of AMS suitable standards was created through dilution with low-background natural uranium. The techniques used to produce and characterize these materials as well as analysis of them using AMS will be discussed.

236U

Exploring the potential and impact of single-crystal active materials on dry-processed electrodes for high-performance lithium-ion batteries

Roll-to-roll powder-to-film dry processing (DP) and single-crystal (SC) active materials (AMs) with many advantages are two hot topics of lithium-ion batteries (LIBs). However, DP of SC AMs for LIBs is rarely reported. Consequently, the impact of SC AMs on dry-processed LIBs is not well understood. Herein, for the first time, via a set of experimental and theoretical studies of the conventional polycrystalline-AM- and SC-AM-based DPed electrodes (DPEs), this work not only reports a high-performance dry SC-AM cathode for LIB manufacturing, but also establishes some fundamental understanding of SC-based dry-processed electrodes, including their morphology, structure, mechanical strength, electronic conductivity and LIB electrochemical behavior. Further, the results suggest that DP of SC AMs is promising, which can dramatically improve the electrochemical kinetics at electrode level and particle level. Specifically, for the rate capability and long-term cyclability in full cells, SC DPEs exhibit a discharge specific capacity of 152.1 mAh g -1 at 1C and a capacity retention rate of 79.9 % at C/3 over 500 cycles, which are superior to those of PC DPEs (135.6 mAh g -1 and 68.3 %) at the same conditions and are further confirmed by the simulation data from the theoretical modelling study. Therefore, this comprehensive work marks a significant milestone for DP strategy and SC AMs, enlightening future research and development of LIB manufacturing.

25 ENERGY STORAGE

Using Separation-Enhanced Isotope Ratio Mass Spectrometry to Enable Increased Renewable Carbon Content in Transportation Fuels (CRADA 525)

Stable isotope ratio measurements of carbon atoms using isotope ratio mass spectrometry (IRMS) can be an effective tool for quantifying biogenic carbon in co-processed fuels, with results approaching the precision and accuracy of accelerator mass spectrometry (AMS). The lower cost of an IRMS may enable deployment to refineries, improving access and analysis turnaround times (≤2 hours), and, by extension, provide data that can allow process optimization to maximize renewable carbon in desired refinery products. This project explored the integration of chemical separation with IRMS analyses to enable highly detailed tracking of biogenic carbon into fuel product streams separated by boiling point range, chemical class, or specific compound. Forty-nine fuels and fuel components of fossil and biogenic origin, spanning gasoline and diesel boiling point ranges, were received from three refiners and were analyzed for their δ 13 C values via IRMS. Results spanned a 13 C range from ca. 10‰ to 44‰ and reflect materials derived from sustainable sources (e.g., C4 or C3 plants, animal-based pathways, syngas) or from fossil-derived fuels. Common ranges are approximately 18‰ to 9‰ and approximately 30‰ to 20‰ for C4 and C3 plants, respectively, and approximately 34‰ to 24‰ and approximately 70‰ to 33‰ for petroleum-derived fuels and methane, respectively. Fuel-like standards were developed and tested using direct-injection elemental analyzer (EA) IRMS for liquid fuels. This method was compared with the published methods, yielding statistically similar results. Four blend curve sets were produced ranging from 0% to 100% of a fuel containing biogenic carbon, focusing on 0% to 10% biogenic carbon. Linear fits were the most applicable for two of the four blend curve sets; however, two sets were found to exhibit slightly quadratic behavior, which was more pronounced in low biogenic blend samples, necessitating second-order fits. The origin of the slight quadratic behavior remains unclear; however, the discussion points to possible interpretations. CanmetENERGY thoroughly characterized a majority of the samples using one- and two-dimensional gas chromatography (GC and GC×GC, respectively) and other analyses. Selected samples were subjected to solid phase extraction (SPE) for saturate, olefin, aromatic, and polar (SOAP) analysis, and the resulting solvent-diluted fractions containing saturates and aromatics were returned to Pacific Northwest National Laboratory (PNNL), where the solvent was removed via evaporation or physical separation using GC techniques. Characterization and separations provided an understanding of saturate and aromatic content, as well as boiling point ranges for each sample and sample fraction. Samples resulting from SPE were examined using EA-IRMS and gas chromatography combustion IRMS (GC-C-IRMS) analyses. Both approaches suggest that the range in values between end-members can be increased by selecting the paraffinic or aromatic fraction of the end-member or by selecting among individual compounds resulting from GC separation of the paraffinic fractions. Considerable work remains to put these approaches into practice and statistically validate the benefit for using a fraction or individual compound over bulk analysis of a sample. However, initial results suggest that separations provide advantages for samples having blend ratios of less than 10% biogenic blendstocks. 13 C results showed statistically similar biofuel blend results to those obtained at PNNL, although additional work is needed to obtain better reproducibility. Select samples were sent to Los Alamos National Laboratory (LANL) for IRMS measurements and Beta Analytics for AMS measurements. This work suggests that IRMS and AMS yield closely comparable results and in some circumstances, IRMS could serve as a surrogate for AMS. While additional work is needed to better resolve statistical advantages for separations and better show the comparable nature of IRMS and AMS in both the biogenic carbon analysis of bulk chemical classes, initial results from this study suggest that these should be pursued in order to proliferate this approach for quantifying biogenic carbon in transportation fuels to the refinery level, thereby potentially enabling process optimization in co-processing scenarios.

09 BIOMASS FUELS

Application of a Chemical Index to Aerosol Mass Spectrometry: Delta Plots and Functional Group Distributions

A better understanding of the chemical properties of organic aerosol (OA) particles will improve our ability to characterize their sources and predict their lifetime. The high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is widely used to measure OA in real time using thermal vaporization followed by electron ionization (EI). EI creates fragment ions that can be assigned to functional groups using delta analysis, a method of classifying mass spectra according to the presence of different chemically related ion series. In this study, we demonstrate the application of delta analysis to characterize molecular structures using a new visualization method. We also use delta analysis to quantify the functional group distribution with an average absolute error of ∼5–6% for individual standard molecules, comparable to the error observed for OA mixtures from biomass and coal combustion fit with Fourier transform infrared spectroscopy. Finally, we apply delta functional group analysis to AMS positive matrix factorization (PMF) factors across seven different field campaigns and find a similar composition across the more oxidized factors with about 55% acid and 26% alcohol groups. The analysis method described here can be applied to any HR-ToF-AMS data set to provide quantitative relative functional group distributions for OA mixtures.

aerosol

Single-particle chemical analysis reveals organic-rich detonation soot products

The detonation of high explosives produces a wide variety of particulate matter (PM) with distinct properties, not all of which are traditionally studied for chemical composition, formation processes, and forensic applications. We report particle-resolved measurements of Composition B detonation soot using soot particle aerosol mass spectrometry (SP-AMS), identifying carbonaceous species and metals not previously characterized on a single-particle basis. Results are combined with scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDS) to enhance source-dependent signatures. Black carbon, including graphitic carbon and detonation nanodiamonds, contributed 50.5-71.4% of PM 2.5 mass, while 22.5-43.4% was non-refractory organic carbon, a previously overlooked component that exhibited a complex and varying composition. Detonations were performed with and without PMMA confinement and under steady and overdriven conditions. Distinct particles enriched with polycyclic aromatic hydrocarbons (PAHs) were observed in experiments utilizing confinement, with quantities dependent on manufacturing method. SEM-EDS validated SP-AMS findings of metals internally mixed with carbonaceous species and extended the particle size range to 100 µm. This work makes detecting non-refractory organics using single-particle techniques more feasible for detonation forensics and understanding high-energy soot formation. While this analysis uses offline sample collection, SP-AMS could be deployed for in-situ measurements of detonation PM 2.5 transported in the atmosphere.

36 MATERIALS SCIENCE