Potential reductions in fine particulate matter and premature mortality following implementation of air pollution controls on coal-fired power plants in India

Coal-fired power plants (CFPPs) account for > 70% of electricity generation in India, but < 5% of facilities have installed technologies for sulfur dioxide (SO 2 ) and nitrogen oxide (NO X ) removal. Emissions of these pollutants lead to the formation of fine particulate matter (PM 2.5 ) and an increased risk of premature mortality for exposed populations. Here, we use a nested version of the GEOS-Chem global chemical transport model (0.5° × 0.625° resolution) for India to estimate reductions in PM 2.5 concentrations that could have been achieved by implementing existing emission control technologies like flue-gas desulfurization (FGD) and/or selective catalytic reduction (SCR). We quantify the associated burden of disease using the integrated exposure response (IER) and global exposure mortality model (GEMM) functions and compare the costs of premature mortality to those for FGD installation. Model simulations for 2010 suggest installation of FGD would have reduced mean annual PM 2.5 concentrations across India by 8%, compared to 3% with SCR installation, and 11% with both FGD and SCR. A 7–28% reduction in PM 2.5 was simulated for local communities closest to CFPPs (same model grid cell), leading to up to 17% reduction in annual premature mortality. Overall, more than 0.21–0.48 million premature deaths would have been avoided over a 10-year period if FGD had been implemented on all CFPPs, compared to 0.09–0.21 million with SCR and 0.22–0.72 million with both FGD and SCR. Benefits associated with such actions are approximately $\$18.1$–$\$604$ billion USD per year, which is equivalent to ~ 0.44 to 10% of India’s GDP. These results suggest that monetary benefits from avoided premature mortality far outweigh the capital and operational costs of FGD and/or SCR installation of $\$19.5$ billion and/or $\$32.8$ billion per year, respectively. This information is essential because the high costs of installation and operation are often given as reasons for delaying installation and commissioning. Finally, we conclude that policy actions to control air pollution from CFPPs are economically justifiable.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Life-cycle-assessment of the historical development of air pollution control and energy recovery in waste incineration

Incineration of municipal solid waste is a debated waste management technology. In some countries it is the main waste management option whereas in other countries it has been disregarded. The main discussion point on waste incineration is the release of air emissions from the combustion of the waste, but also the energy recovery efficiency has a large importance. The historical development of air pollution control in waste incineration was studied through life-cycle-assessment modelling of eight different air pollution control technologies. The results showed a drastic reduction in the release of air emissions and consequently a significant reduction in the potential environmental impacts of waste incineration. Improvements of a factor 0.85-174 were obtained in the different impact potentials as technology developed from no emission control at all, to the best available emission control technologies of today (2010). The importance of efficient energy recovery was studied through seven different combinations of heat and electricity recovery, which were modelled to substitute energy produced from either coal or natural gas. The best air pollution control technology was used at the incinerator. It was found that when substituting coal based energy production total net savings were obtained in both the standard and toxic impact categories. However, if the substituted energy production was based on natural gas, only the most efficient recovery options yielded net savings with respect to the standard impacts. With regards to the toxic impact categories, emissions from the waste incineration process were always larger than those from the avoided energy production based on natural gas. The results shows that the potential environmental impacts from air emissions have decreased drastically during the last 35 years and that these impacts can be partly or fully offset by recovering energy which otherwise should have been produced from fossil fuels like coal or natural gas.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Detecting tropospheric composition and climate responses to US air pollution controls in the context of internally-arising variability

Since the 1970s, air pollutant emissions controls in the United States (US) have lowered concentrations of ozone (O 3 ) and aerosols, which have opposing radiative effects on surface temperature. Using a pair of initial-condition ensembles generated by a fully-coupled chemistry-climate model, we simulate the “world avoided” by US air pollution controls. In this counterfactual world, we find tropospheric column O 3 increases, robust to natural internal variability, extending across the Northern Hemisphere. Robust aerosol increases, dominated by sulfate, remain localized near the US. Wintertime Northwest Atlantic cloud droplet number concentration is particularly sensitive to US aerosol. While an ensemble mean US surface cooling signal (−0.4 °C) implies that aerosol-driven cooling prevails over any O 3 -induced warming, we find that large regional internal variability will confound its detection in any single transient realization. Larger signal-to-noise ratios for composition versus climate variables underscore the greater detectability of emissions-driven changes in tropospheric composition compared to their associated climate impacts.

54 ENVIRONMENTAL SCIENCES↗

Win–Win strategies to promote air pollutant control policies and non-fossil energy target regulation in China

The rapid growth of energy consumption in China has led to increased emissions of air pollutants. As a response, in its 12th Five Year Plan the Chinese government proposed mitigation targets for SO2 and NOx emissions. Herein we have investigated mitigation measures taken in different sectors and their corresponding impacts on the energy system. Additionally, as non-fossil energy development has gained traction in addressing energy and environmental challenges in China, we further investigated the impact of non-fossil energy development on air pollutant emissions, and then explored interactions and co-benefits between these two types of policies. An extended Global Change Assessment Model (GCAM) was used in this study, which includes an additional air pollutant emissions control module coupling multiple end-of-pipe (EOP) control technologies with energy technologies, as well as more detailed end-use sectors in China. We find that implementing EOP control technologies would reduce air pollution in the near future, but with little room left to implement these EOP technologies, other cleaner and more efficient technologies are also effective. These technologies would reduce final energy consumption, increase electricity’s share in final energy, and increase the share of non-fossil fuels in primary energy and electricity consumption. Increasing non-fossil energy usage at China’s proposed adoption rate would in turn also reduce SO2 and NOx emissions, however, the reductions from this policy alone still lag behind the targeted requirements of air pollutant reduction. Fortunately, a combination of air pollutant controls and non-fossil energy development could synergistically help realize the respective individual targets, and would result in lower costs than would addressing these issues separately.

Air pollution↗

Air pollution control strategies directly limiting national health damages in the US

Exposure to fine particulate matter (PM 2.5 ) from fuel combustion significantly contributes to global and US mortality. Traditional air pollution control strategies typically focus on emission reductions for specific air pollutants or sectors to maintain air pollutant concentrations within acceptable levels. Here we directly set national PM 2.5 mortality cost reduction targets within a global human-earth system model with US state-level energy systems, identifying endogenously the control actions, sectors, and locations that most cost-effectively reduce PM 2.5 mortality. Our results show that substantial health benefits can be cost-effectively achieved by using electricity to replace sources with high primary PM 2.5 emission intensities, including industrial coal, building biomass, and industrial liquids. Increasing the stringency of PM 2.5 reduction targets expedites the phaseout of high emission intensity sources, leading to larger declines in major air pollutant emissions, but very limited co-benefits in reducing CO 2 emissions. Control strategies achieve the greatest mortality cost reductions in the East North Central and Middle Atlantic states.

54 ENVIRONMENTAL SCIENCES↗

Fate of mercury collected from air pollution control devices

Mercury that enters a coal-fired power plant originates from the coal that is burned and leaves through the output streams, which include stack emissions and air pollution control (APC) residues (either in solid or liquid form). This article describes recent findings on the fate and environmental stability of mercury in coal combustion residues (CCRs) such as fly ash and solid products from flue gas desulfurization (FGD) scrubbers when either disposed or reused in agricultural, commercial, or engineering applications. 19 refs., 4 figs., 5 tabs.

01 COAL, LIGNITE, AND PEAT↗

Air pollution control systems in WtE units: An overview

Highlights: • The paper describes in brief terms the development of gas cleaning in waste incineration. • The main technologies for pollutant removal are described including their basic mechanisms. • Their respective efficiencies and their application are discussed. • A cautious outlook regarding future developments is made. - Abstract: All WtE (waste-to-energy) plants, based on combustion or other thermal processes, need an efficient gas cleaning for compliance with legislative air emission standards. The development of gas cleaning technologies started along with environment protection regulations in the late 1960s. Modern APC (air pollution control) systems comprise multiple stages for the removal of fly ashes, inorganic and organic gases, heavy metals, and dioxins from the flue gas. The main technologies and devices used for abatement of the various pollutants are described and their basic principles, their peculiarities, and their application are discussed. Few systems for cleaning of synthesis gas from waste gasification plants are included. Examples of APC designs in full scale plants are shown and cautious prospects for the future development of APC systems are made.

54 ENVIRONMENTAL SCIENCES↗

Element composition and mineralogical characterisation of air pollution control residue from UK energy-from-waste facilities

Highlights: • 66 elements, including “critical strategic elements” were determined in UK EfW APC residues. • Metal pollutants (Zn, Pb, As, Cd, Cu, Mo, Sb, Sn, Se, Ag and In) are enriched in APC residues. • Metal pollutants were widely associated with fine deposits of highly soluble CaCl{sub x}OH{sub 2−x}. • Specific metal (Zn, Pb, Cu)-bearing minerals were also detected in APC residues. - Abstract: Air pollution control (APC) residues from energy-from-waste (EfW) are alkaline (corrosive) and contain high concentrations of metals, such as zinc and lead, and soluble salts, such as chlorides and sulphates. The EPA 3050B-extractable concentrations of 66 elements, including critical elements of strategic importance for advanced electronics and energy technologies, were determined in eight APC residues from six UK EfW facilities. The concentrations of Ag (6–15 mg/kg) and In (1–13 mg/kg), as well as potential pollutants, especially Zn (0.26–0.73 wt.%), Pb (0.05–0.2 wt.%), As, Cd, Cu, Mo, Sb, Sn and Se were found to be enriched in all APC residues compared to average crustal abundances. Results from a combination of scanning electron microscopy with energy dispersive X-ray spectroscopy and also powder X-ray diffraction, thermal analysis and Fourier transform infrared spectroscopy give an exceptionally full understanding of the mineralogy of these residues, which is discussed in the context of other results in the literature. The present work has shown that the bulk of the crystalline phases present in the investigated APC residues include Ca-based phases, such as CaCl{sub x}OH{sub 2−x}, CaCO{sub 3}, Ca(OH){sub 2}, CaSO{sub 4}, and CaO, as well as soluble salts, such as NaCl and KCl. Poorly-crystalline aragonite was identified by FTIR. Sulphur appears to have complex redox speciation, presenting as both anhydrite and hannebachite in some UK EfW APC residues. Hazardous elements (Zn and Pb) were widely associated with soluble Ca- and Cl-bearing phases (e.g. CaCl{sub x}OH{sub 2−x} and sylvite), as well as unburnt organic matter and aluminosilicates. Specific metal-bearing minerals were also detected in some samples: e.g., Pb present as cerussite; Zn in gahnite, zincowoodwardite and copper nickel zinc oxide; Cu in tenorite, copper nickel zinc oxide and fedotovite. Aluminium foil pieces were present and abundantly covered by fine phases, particularly in any cracks, probably in the form of Friedel’s salt.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Air pollution control residues from waste incineration: Current UK situation and assessment of alternative technologies

Current disposal options for APC residues in the UK and alternative treatment technologies developed world-wide have been reviewed. APC residues are currently landfilled in the UK where they undergo in situ solidification, although the future acceptability of this option is uncertain because the EU waste acceptance criteria (WAC) introduce strict limits on leaching that are difficult to achieve. Other APC residue treatment processes have been developed which are reported to reduce leaching to below relevant regulatory limits. The Ferrox process, the VKI process, the WES-PHix process, stabilisation/solidification using cementitious binders and a range of thermal treatment processes are reviewed. Thermal treatment technologies convert APC residues combined with other wastes into inert glass or glass-ceramics that encapsulate heavy metals. The waste management industry will inevitably use the cheapest available option for treating APC residues and strict interpretation and enforcement of waste legislation is required if new, potentially more sustainable technologies are to become commercially viable.

54 ENVIRONMENTAL SCIENCES↗

Assessment of the Effect of Air Pollution Controls on Trends in Shortwave Radiation over the United States from 1995 through 2010 from Multiple Observation Networks

Long term datasets of total (all-sky) and clear-sky downwelling shortwave (SW) radiation, cloud cover fraction (cloudiness) and aerosol optical depth (AOD) are analyzed together with aerosol concentration from several networks (e.g. SURFRAD, CASTNET, IMPROVE and ARM) in the United States (US). Seven states with varying climatology are selected to better understand the effect of aerosols and clouds on SW radiation. This analysis aims to test the hypothesis that the reductions in anthropogenic aerosol burden resulting from substantial reductions in emissions of sulfur dioxide and nitrogen oxides over the past 15 years across the US has caused an increase in surface SW radiation. We show that the total and clear-sky downwelling SW radiation from seven sites have increasing trends except Penn State which shows no tendency in clear-sky SW radiation. After investigating several confounding factors, the causes can be due to the geography of the site, aerosol distribution, heavy air traffic and increasing cloudiness. Moreover, we assess the relationship between total column AOD with surface aerosol concentration to test our hypothesis. In our findings, the trends of clear-sky SW radiation, AOD, and aerosol concentration from the sites in eastern US agree well with our hypothesis. However, the sites in western US demonstrate increasing AOD associated with mostly increasing trends in surface aerosol concentration. At these sites, the changes in aerosol burden and/or direct aerosol effects alone cannot explain the observed changes in SW radiation, but other factors need to be considered such as cloudiness, aerosol vertical profiles and elevated plumes.

1995-2010↗

Climate and air pollution implications of potential energy infrastructure and policy measures in India

India is a rapidly developing economy with interrelated air quality, sustainable development, and climate change mitigation goals. There are unique challenges to achieving each of these goals as well as potential tradeoffs among them. This study examines the implications of possible future energy, climate, and air pollution control policies and measures in India through 2050. We take a scenario approach using the GCAM global energy-climate-land model combined with the Hector simple climate model and the TM5-FASST air quality source-receptor model to examine energy, climate and air quality outcomes. Reducing use of traditional biomass in buildings can reduce primary carbonaceous particulate emissions well below 2015 levels. However, policies that are more ambitious than current plans would likely be required to reduce SO 2 and NO x emissions well below 2015 levels. Among single policy cases considered, pricing of greenhouse gas (GHG) emissions and expansion of natural gas infrastructure have the largest impacts on overall energy system changes relative to the reference scenario. Ambitious air pollution control and GHG policies lead to the largest reductions in air pollution concentrations and radiative forcing, respectively. However, ambitious air pollution control and GHG policies differ in the extent to which they support or impede other policy objectives. Forcing increases due to reduced aerosols from ambitious air pollution policies can be mitigated, at least in part, by applying air pollution control and GHG policies together.

India↗

Effectiveness of environmental policies at OAO Koks

OAO Koks has introduced a comprehensive program for more stable plant operation and reduced environmental impact in the period 2004 2010. Methods of group relining of the coking-furnace chambers and hot repair of coke furnaces with complete relining of the heating walls have been adopted. Water-protection measures include the construction of an additional water-circulation cycle for the chemical shops, completion of the first stage of wastewater treatment, and reconstruction of the biochemical processing system for phenolic and oily water. A mobile environmental station has been acquired for air-quality monitoring.

01 COAL, LIGNITE, AND PEAT↗

Dust control for draglines

Monitoring dust levels inside draglines reveals room for improvement in how filtration systems are used and maintained. The Australian firm BMT conducted a field test program to measure airflow parameters, dust fallout rates and dust concentrations, inside and outside the machine house, on four draglines and one shovel. The study involved computational fluid dynamics (CFD) simulations. The article describes how the tests were made and gives results. It was not possible to say which of the two main filtration systems currently used on Australian draglines - Dynavane or Floseps - performs better. It would appear that more frequent maintenance and cleaning would increase the overall filtration performance and systems could be susceptible to repeat clogging in a short time. 2 figs., 1 photos.

01 COAL, LIGNITE, AND PEAT↗

Introduction of a method for presenting health-based impacts of the emission from products, based on emission measurements of materials used in manufacturing of the products

A method for presenting the health impact of emissions from furniture is introduced, which could be used in the context of environmental product declarations. The health impact is described by the negative indoor air quality potential, the carcinogenic potential, the mutagenic and reprotoxic potential, the allergenic potential, and the toxicological potential. An experimental study of emissions from four pieces of furniture is performed by testing both the materials used for production of the furniture and the complete piece of furniture, in order to compare the results gained by adding emissions of material with results gained from testing the finished piece of furniture. Calculating the emission from a product based on the emission from materials used in the manufacture of the product is a new idea. The relation between calculated results and measured results from the same products differ between the four pieces of furniture tested. Large differences between measured and calculated values are seen for leather products. More knowledge is needed to understand why these differences arise. Testing materials allows us to compare different suppliers of the same material. Four different foams and three different timber materials are tested, and the results vary between materials of the same type. If the manufacturer possesses this type of knowledge of the materials from the subcontractors it could be used as a selection criterion according to production of low emission products. -- Highlights: • A method for presenting health impact of emissions is introduced. • An experimental study of emissions from four pieces of furniture is performed. • Health impact is calculated based on sum of contribution from the materials used. • Calculated health impact is compared to health impact of the manufactured product. • The results show that health impact could be useful in product development and for presentation in EPDs.

54 ENVIRONMENTAL SCIENCES↗

Greenridge Multi-Pollutant Control Project Preliminary Public Design Report

The Greenidge Multi-Pollutant Control Project is being conducted as part of the U.S. Department of Energy's Power Plant Improvement Initiative to demonstrate an innovative combination of air pollution control technologies that can cost-effectively reduce emissions of SO{sub 2}, NO{sub x}, Hg, acid gases (SO{sub 3}, HCl, and HF), and particulate matter from smaller coal-fired electrical generating units (EGUs). The multi-pollutant control system includes a hybrid selective non-catalytic reduction (SNCR)/in-duct selective catalytic reduction (SCR) system to reduce NOx emissions by {ge}60%, followed by a Turbosorp{reg_sign} circulating fluidized bed dry scrubber system to reduce emissions of SO{sub 2}, SO{sub 3}, HCl, and HF by {ge}95%. Mercury removal of {ge}90% is also targeted via the co-benefits afforded by the in-duct SCR, dry scrubber, and baghouse and by injection of activated carbon upstream of the scrubber, as required. The technology is particularly well suited, because of its relatively low capital and maintenance costs and small space requirements, to meet the needs of coal-fired units with capacities of 50-300 MWe. There are about 440 such units in the United States that currently are not equipped with SCR, flue gas desulfurization (FGD), or mercury control systems. These smaller units are a valuable part of the nation's energy infrastructure, constituting about 60 GW of installed capacity. However, with the onset of the Clean Air Interstate Rule, Clean Air Mercury Rule, and various state environmental actions requiring deep reductions in emissions of SO{sub 2}, NO{sub x}, and mercury, the continued operation of these units increasingly depends upon the ability to identify viable air pollution control retrofit options for them. The large capital costs and sizable space requirements associated with conventional technologies such as SCR and wet FGD make these technologies unattractive for many smaller units. The Greenidge Project aims to confirm the commercial readiness of an emissions control system that is specifically designed to meet the environmental compliance requirements of these smaller coal-fired EGUs. The multi-pollutant control system is being installed and tested on the AES Greenidge Unit 4 (Boiler 6) by a team including CONSOL Energy Inc. as prime contractor, AES Greenidge LLC as host site owner, and Babcock Power Environmental Inc. as engineering, procurement, and construction contractor. All funding for the project is being provided by the U.S. Department of Energy, through its National Energy Technology Laboratory, and by AES Greenidge. AES Greenidge Unit 4 is a 107 MW{sub e} (net), 1950s vintage, tangentially-fired, reheat unit that is representative of many of the 440 smaller coal-fired units identified above. Following design and construction, the multi-pollutant control system will be demonstrated over an approximately 20-month period while the unit fires 2-4% sulfur eastern U.S. bituminous coal and co-fires up to 10% biomass. This Preliminary Public Design Report is the first in a series of two reports describing the design of the multi-pollutant control facility that is being demonstrated at AES Greenidge. Its purpose is to consolidate for public use all available nonproprietary design information on the Greenidge Multi-Pollutant Control Project. As such, the report includes a discussion of the process concept, design objectives, design considerations, and uncertainties associated with the multi-pollutant control system and also summarizes the design of major process components and balance of plant considerations for the AES Greenidge Unit 4 installation. The Final Public Design Report, the second report in the series, will update this Preliminary Public Design Report to reflect the final, as-built design of the facility and to incorporate data on capital costs and projected operating costs.

01 COAL, LIGNITE, AND PEAT↗

Corrosion Effects of Calcium Chloride Injection for Mercury Control on the Pollution Control Equipment

In response to the Clean Air Mercury Rule (CAMR) of 2005, Black Hills Power (BHP) initiated testing of a calcium chloride (CaCl{sub 2}) injection method in their Wygen 1 (Gillette, WY) coal-fired power plant to help lower mercury emissions. In 2006, Babcock & Wilcox (B&W) was contracted to test their CaCl{sub 2} technology in-situ by adding a CaCl{sub 2} solution onto the raw, pre-pulverized coal during normal operation of Wygen 1. Follow-up tests were conducted by BHP in 2007. Data were collected from these two time periods and analyzed by a collaborative investigation team from Western Research Institute (WRI) and the University of Wyoming (UW) to see if there were any effects on the current air pollution control systems. During a CaCl{sub 2} injection period in 2007, corrosion was monitored in the flue and recycle ash system by placing corrosion coupons in strategic locations to test if corrosion was enhanced by the CaCl{sub 2} injection. While the CaCl{sub 2} produced a reduction in stack mercury levels, there was some evidence of beneficial impacts on the removal of SO{sub 2} from the flue gas during CaCl{sub 2} injection. Data on NOx remained inconclusive. It was also discovered that corrosion was enhanced significantly in the Spray Drier Absorber (SDA) vessel and corresponding outlet ductwork during CaCl{sub 2} injections. Further studies are being carried out in the field and lab to better understand the corrosive effects of CaCl{sub 2} to help formulate operation controls to manage the increased corrosion rates.

01 COAL, LIGNITE, AND PEAT↗

Surface Brightening in Eastern and Central China Since the Implementation of the Clean Air Action in 2013: Causes and Implications

Surface brightening has been observed in China since 2005. However, it remains unclear whether the brightening has accelerated recently in response to the strictest ever air pollution control policies since 2013. By combining intensive surface and satellite observations, we find an unprecedented rapid increasing trend in surface solar radiation (SSR) of 0.70–1.16 W m-2 yr-1 over the eastern and central China for 2014–2019. Using a novel method to identify the relative contributions of aerosol and cloud radiative effects to the SSR trends, we find that the strongly declining aerosol radiative effect due to the strict air pollution controls is the main cause of the upward SSR trends; cloud variations should not be the main reason. Distinction exists in seasonal trends of SSR, with decreasing trends in winter and increasing trends in other seasons. Air pollution controls play an important role in regulating SSR, which has valuable implications for photovoltaic power generation.

Shi, Hongrong↗

Emission Inventories and Projections

When the Executive Body to the Convention on Long-range Transboundary Air Pollution took the decision to establish the Task Force on Hemispheric Transport of Air Pollution (TF HTAP) in December 2004, it was on the basis of a growing understanding of the issues surrounding the hemispheric and intercontinental transport of air pollutants. It was recognised that whilst current regional emissions on their own created pollution levels that exceeded internationally-agreed air quality objectives, hemispheric transport could exacerbate local and regional air quality problems.Two particular pollutants of concern, and the focus of this report, are ozone and particulate matter (PM), known for their detrimental impacts on human health (these impacts and others are described in Chapter 5). There was well-documented evidence for the intercontinental transport of ozone and PM but, at that time, the significance of this intercontinental influence on the design of air pollution control policies was not well understood. The European Union, in drawing up its Thematic Strategy on Clean Air for Europe during 2004, became aware of the significance of intercontinental transport and the importance of sources of pollution beyond its borders and sphere of influence, in meeting its air quality goals.

54 ENVIRONMENTAL SCIENCES↗