Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIR INFILTRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An inverse approach to solving zone air infiltration rate and people count using indoor environmental sensor data

Physics-based simulation of energy use in buildings is typically widely used in building design and performance rating, controls design and operations. However, various challenges exist in the modeling process. Model parameters such as people count and air infiltration rate are usually highly uncertain, yet they have significant impacts on the simulation accuracy. With the increasing availability and affordability of sensors and meters in buildings, a large amount of measured data has been collected including indoor environmental parameters, such as room air dry-bulb temperature, humidity ratio, and CO 2 concentration levels. Fusing these sensor data with traditional energy modeling poses new opportunities to improve simulation accuracy. This study develops a set of physics-based inverse algorithms which can solve the highly uncertain and hard-to-measure building parameters such as zone-level people count and air infiltration rate. A simulation-based case study is conducted to verify the inverse algorithms implemented in EnergyPlus covering various sensor measurement scenarios and different modeling use cases. The developed inverse models can solve the zone people count and air infiltration at sub-hourly resolution using the measured zone air temperature, humidity and/or CO 2 concentration given other easy-to-measure model parameters are known.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simultaneously improved reversibility and hydrogen production of solid oxide cells through infiltrating air electrode

Among the various fuel cells, solid oxide cells (SOCs) are the unique type that can principally operate reversibly as either fuel cells to produce electricity or as an electrolyser to split water and produce green hydrogen (H 2 ). Nevertheless, the SOCs' reversibility presents enormous challenges that are manifested by the fast degradation through the cycling between fuel cell and electrolysis mode. While the La 0.8 Sr 0.2 MnO 3 /yttria-stabilized zirconia (LSM/YSZ) air electrode possesses significant advantages in terms of high electrical conductivity and high thermal stability under fuel cell mode, the SOCs with the LSM/YSZ air electrode experience rapid performance degradation with catastrophic electrode delamination shortly after switching from fuel cell to electrolysis mode. To prevent such catastrophic delamination and enable the electrolysis H 2 production, a chemical solution with the designed chemistry of SrFe 2 O 4-d was infiltrated into the LSM/YSZ air electrode. The infiltration immediately mitigates the catastrophic delamination, and the infiltrated cells exhibit significantly improved reversibility upon the electrochemical operation. Nanostructure examination reveals nanoscale cracks and second-phase nanograins formed in the air electrode from the baseline cell. By contrast, no delamination was observed at either the micron or the nanoscale for the infiltrated cell, which is attributed to the increased ion conductivity of the Fe-doped LSM mixed conductor induced by the significant interdiffusion between the LSM backbone and infiltrates. Here, this study presents a viable method for preventing electrode delamination while enhancing the durability of H 2 production and power generation for reversible fuel cell/electrolysis cell operation. It further opens new research directions of modifying the electrochemical activity of the electrode of inherently functional cells through the infiltration of the solutions with different chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of Modular Modeling System to Predict Evaporation, Infiltration, Air Temperature, and Soil Moisture

Models are used for numerous application including hydrology. The Modular Modeling System (MMS) is one of the few that can simulate a hydrology process. MMS was tested and used to compare infiltration, soil moisture, daily temperature, and potential and actual evaporation for the Elinsboro sandy loam soil and the Mattapex silty loam soil in the Microwave Radiometer Experiment of Soil Moisture Sensing at Beltsville Agriculture Research Test Site in Maryland. An input file for each location was created to nut the model. Graphs were plotted, and it was observed that the model gave a good representation for evaporation for both plots. In comparing the two plots, it was noted that infiltration and soil moisture tend to peak around the same time, temperature peaks in July and August and the peak evaporation was observed on September 15 and July 4 for the Elinsboro Mattapex plot respectively. MMS can be used successfully to predict hydrological processes as long as the proper input parameters are available.

Boggs, Johnny↗

Healthy Indoor Air Quality: A Guide to Understanding Pollutants in Extreme Cold Climates

Internal air quality management through commonly supported recommendations in extreme cold weather climates is complicated by cold air infiltration. Air filtration and IAQ monitoring, through central and stand-alone systems can improve internal air quality to the benefit of occupant health and safety. This fact sheet includes reference information for pollutants, sources, health effects, and mitigation strategies.

cold climate↗

Effectiveness of Urban Shelter-in-Place. III: Commercial Districts

In the event of a toxic chemical release to the atmosphere, shelter-in-place (SIP) is an emergency response option available to protect public health. This paper is the last in a three-part series that examines the effectiveness of SIP at reducing adverse health effects in communities. We model a hypothetical chemical release in an urban area, and consider SIP effectiveness in protecting occupants of commercial buildings. Building air infiltration rates are predicted from empirical data using an existing model. We consider the distribution of building air infiltration rates both with mechanical ventilation systems turned off and with the systems operating. We also consider the effects of chemical sorption to indoor surfaces and nonlinear chemical dose-response relationships. We find that commercial buildings provide effective shelter when ventilation systems are off, but that any delay in turning off ventilation systems can greatly reduce SIP effectiveness. Using a two-zone model, we find that there can be substantial benefit by taking shelter in the inner parts of a building that do not experience direct air exchange with the outdoors. Air infiltration rates vary substantially among buildings and this variation is important in quantifying effectiveness for emergency response. Community-wide health metrics, introduced in the previous papers in this series, can be applied in pre-event planning and to guide real-time emergency response.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Assessing the impacts of air-sealing on the sizing, operation, and economic feasibility of ground-source heat pumps for electrifying single-family houses in the US

According to recent studies and reports, in single-family houses (SFHs), air-sealing can significantly lower the thermal loads for space heating and cooling. Thus, air-sealing in SFHs could reduce the required size and cost of ground source heat pump (GSHP) systems for electrifying SFHs. Here, this study investigated the costs and benefits of integrating air-sealing with GSHPs for retrofitting existing SFHs when compared with air-source heat pumps. A whole building energy simulation tool integrated with an advanced design tool for modeling ground heat exchangers was used to calculate changes in required GSHP capacity, total borehole length, and building energy consumption with and without air-sealing in SFHs in 16 US climatic regions. The results from this study showed that reducing outdoor air infiltration from 0.8 air changes per hour (ACH) to the minimum ventilation requirement (0.35 ACH) can significantly reduce borehole length (up to 55 %), GSHP capacity (up to 48 %), and total heating electricity reduction, especially in cold climates (up to 44 %). The results also showed that for airtight homes (0.03 ACH infiltration) with a direct outdoor air system, the minimum required borehole length, GSHP capacity, and total heating electricity consumption can be reduced up to 70 %, 68 %, and 67 %, respectively, when compared with SFHs with 0.8 ACH infiltration. Moreover, the life cycle cost analysis showed that air-sealing in conjunction with a GSHP is more profitable than replacing the existing system with an air-source heat pump, even without any incentives for most climatic regions in the US (except for some hot regions).

15 GEOTHERMAL ENERGY↗

Advanced Energy Efficient Roof System

Energy consumption in buildings represents 40 percent of primary U.S. energy consumption, split almost equally between residential (22%) and commercial (18%) buildings.1 Space heating (31%) and cooling (12%) account for approximately 9 quadrillion Btu. Improvements in the building envelope can have a significant impact on reducing energy consumption. Thermal losses (or gains) from the roof make up 14 percent of the building component energy load. Infiltration through the building envelope, including the roof, accounts for an additional 28 percent of the heating loads and 16 percent of the cooling loads. These figures provide a strong incentive to develop and implement more energy efficient roof systems. The roof is perhaps the most challenging component of the building envelope to change for many reasons. The engineered roof truss, which has been around since 1956, is relatively low cost and is the industry standard. The roof has multiple functions. A typical wood frame home lasts a long time. Building codes vary across the country. Customer and trade acceptance of new building products and materials may impede market penetration. The energy savings of a new roof system must be balanced with other requirements such as first and life-cycle costs, durability, appearance, and ease of construction. Conventional residential roof construction utilizes closely spaced roof trusses supporting a layer of sheathing and roofing materials. Gypsum board is typically attached to the lower chord of the trusses forming the finished ceiling for the occupied space. Often in warmer climates, the HVAC system and ducts are placed in the unconditioned and otherwise unusable attic. High temperature differentials and leaky ducts result in thermal losses. Penetrations through the ceilings are notoriously difficult to seal and lead to moisture and air infiltration. These issues all contribute to greater energy use and have led builders to consider construction of a conditioned attic. The options considered to date are not ideal. One approach is to insulate between the trusses at the roof plane. The construction process is time consuming and costs more than conventional attic construction. Moreover, the problems of air infiltration and thermal bridges across the insulation remain. Another approach is to use structurally insulated panels (SIPs), but conventional SIPs are unlikely to be the ultimate solution because an additional underlying support structure is required except for short spans. In addition, wood spline and metal locking joints can result in thermal bridges and gaps in the foam. This study undertook a more innovative approach to roof construction. The goal was to design and evaluate a modular energy efficient panelized roof system with the following attributes: (1) a conditioned and clear attic space for HVAC equipment and additional finished area in the attic; (2) manufactured panels that provide structure, insulation, and accommodate a variety of roofing materials; (3) panels that require support only at the ends; (4) optimal energy performance by minimizing thermal bridging and air infiltration; (5) minimal risk of moisture problems; (6) minimum 50-year life; (7) applicable to a range of house styles, climates and conditions; (8) easy erection in the field; (9) the option to incorporate factory-installed solar systems into the panel; and (10) lowest possible cost. A nationwide market study shows there is a defined market opportunity for such a panelized roof system with production and semi-custom builders in the United States. Senior personnel at top builders expressed interest in the performance attributes and indicate long-term opportunity exists if the system can deliver a clear value proposition. Specifically, builders are interested in (1) reducing construction cycle time (cost) and (2) offering increased energy efficiency to the homebuyer. Additional living space under the roof panels is another low-cost asset identified as part of the study. The market potential is enhanced through construction activity levels in target markets. Southern markets, from Florida to Texas account for 50 percent of the total new construction angled-roof volume. California contributes an additional 13 percent share of market volume. These states account for 28 to 30 million squares (2.8 to 3 billion square feet) of new construction angled roof opportunity. The major risk to implementation is the uncertainty of incorporating new design and construction elements into the construction process. By coordinating efforts to enhance the drivers for adoption and minimize the barriers, the panelized roof system stands to capitalize on a growing market demand for energy efficient building alternatives and create a compelling case for market adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep Energy Cuts for a Fresh Start

This case study describes an energy-efficient retrofit of 1930's bungalow in Pittsburgh, PA, done in 2008 by New Jersey builder and remodeler Bill Asdal. The gut rehab brought the home’s Home Energy Rating System (HERS) index scores from 185 down to an impressive 65, performance that makes the home 35% better than the 2006 International Energy Conservation Code. The builder kept the shell but stripped the walls down to the studs to seal, caulk, and insulate the building envelope; they also upgraded HVAC, water heating, appliances, lighting, and windows with higher performance but readily available products. A blower door infiltration test showed an air infiltration rate reduction from 0.53 ACH to 0.21 ACH and modeling of energy use showed a drop in total annual energy use from 271 million BTU to 92 million BTU. The home was used as a demonstration home at the ACI 2008 conference in Pittsburgh PA. The builder, Bill Asdal, was the chair of the retrofit committee of the National Association of Home Builders which is partially sponsored by DOE's Building America program. The article, under this title, appeared as the cover story in the trade journal Home Energy magazine Jan Feb 2009 issue. A modified version of this case study under the title "Comprehensive Energy Retrofits Case Study: Asdal Builders, LLC, Pittsburgh, PA" was distributed at the EEBA (Energy and Environmental Building Alliance) Annual Conference in Denver, Colorado, Sept 28-30, 2009.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GridLAB-D Technical Support Document: Residential End-Use Module Version 1.0

1.0 Introduction The residential module implements the following end uses and characteristics to simulate the power demand in a single family home: • Water heater • Lights • Dishwasher • Range • Microwave • Refrigerator • Internal gains (plug loads) • House (heating/cooling loads) The house model considers the following four major heat gains/losses that contribute to the building heating/cooling load: 1. Conduction through exterior walls, roof and fenestration (based on envelope UA) 2. Air infiltration (based on specified air change rate) 3. Solar radiation (based on CLTD model and using tmy data) 4. Internal gains from lighting, people, equipment and other end use objects. The Equivalent Thermal Parameter (ETP) approach is used to model the residential loads and energy consumption. The following sections describe the modeling assumptions for each of the above end uses and the details of power demand calculations in the residential module.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Residential Energy Retrofits

To advance the market penetration of residential retrofits, Oak Ridge National Laboratory (ORNL) and Southface Energy Institute (Southface) partnered to provide technical assistance on nine home energy retrofits in metropolitan Atlanta with simulated source energy savings of 30% to 50%. Retrofit measures included duct sealing, air infiltration reductions, attic sealing and roofline insulation, crawlspace sealing, HVAC and water heating equipment replacement, and lighting and appliance upgrades. This paper will present a summary of these measures and their associated impacts on important home performance metrics, such as air infiltration and duct leakage. The average estimated source energy savings for the homes is 33%, and the actual heating season average savings is 32%. Additionally, a case study describing expected and realized energy savings of completed retrofit measures of one of the homes is described in this paper.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrating physics-based models with sensor data: An inverse modeling approach

Physics-based building energy models (e.g., EnergyPlus) rely on some unknown input parameters (e.g., zone air infiltration) that are hard to measure, leading to uncertainty in simulation results especially for existing buildings with varying operating conditions. With the increasing deployment of smart thermostats, zone air temperature data are readily available, posing a new opportunity for building energy modeling if such data can be harnessed. This study presents a novel inverse modeling approach which inverses the zone air heat balance equation and uses the measured zone air temperature to analytically calculate the zone air infiltration rate and zone internal thermal mass (e.g., furniture, interior partitions), which are two important model parameters with great variability and difficult to measure. This paper introduces the technical concept and algorithms of the inverse models, their implementation in EnergyPlus, and verification using EnergyPlus simulated building performance data. The inverse modeling approach provides new opportunities for integrating data from massive IoT sensors and devices to enhance the accuracy of simulation results which are used to inform decision making on energy retrofits and efficiency improvements of existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of Indoor Air Quality Benefits and Energy Costs of Mechanical Ventilation

Intake of chemical air pollutants in residences represents an important and substantial health hazard. Sealing homes to reduce air infiltration can save space conditioning energy, but can also increase indoor pollutant concentrations. Mechanical ventilation ensures a minimum amount of outdoor airflow that helps reduce concentrations of indoor emitted pollutants while requiring some energy for fan(s) and thermal conditioning of the added airflow. This work demonstrates a physics based, data driven modeling framework for comparing the costs and benefits of whole-house mechanical ventilation and applied the framework to new California homes. The results indicate that, on a population basis, the health benefits from reduced exposure to indoor pollutants in New California homes are worth the energy costs of adding mechanical ventilation as specified by ASHRAE Standard 62.2.This study determines the health burden for a subset of pollutants in indoor air and the costs and benefits of ASHRAE's mechanical ventilation standard (62.2) for new California homes. Results indicate that, on a population basis, the health benefits of new home mechanical ventilation justify the energy costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Zonal Infiltration Measurement Method for Multifamily Buildings: A Novel Test Procedure to Determine Air Leakage Through External and Internal Surfaces

Measuring air infiltration through the external building envelope as well as between adjacent zones within a building is important since air leakage is related to increased energy use and poor indoor air quality (IAQ). State of the art methods can determine both leakages, however it can be both time consuming and labor intensive as it requires running both guarded and compartmentalization tests. This paper presents our work on developing a simplified testing procedure to determine power law flow equation leakage parameters of both external and internal boundaries of tested zones. The proposed Zonal Multipoint Pressure Test (ZMPT) method modulates airflow in the zone using a variable airflow measurement panel (mounted in either a window or the door), and solving the mass balance equations for the leakage parameters. ZMPT results were compared to conventional test results and found to correlate to within +/-7%.

Jayarathne, Tharanga↗