Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AFM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Multiparametric AFM Insights into Electron Transport Mechanisms in Biomemristors

Biomemristors have attracted significant attention due to their applications in biodegradable and flexible electronic devices, and their prospective functions in information storage, neural synapses, and neuromorphic computation. Hence, understanding biomaterials' resistive switching (RS) mechanism is essential to design novel biomemristors with enhanced performance. In the last decade, various atomic force microscopy (AFM) modes, such as Kelvin probe force microscopy (KPFM) and conductive atomic force microscopy (cAFM), in situ/operando visualize the electron transport behaviors within biomemristors at the nanoscale. This review provides a comprehensive discussion of multiparametric AFM techniques to characterize biomemristors and inspire new ideas in developing next-generation consumer electronics. We also summarize the progress of revealing the internal mechanism of biomemristors with functional AFM to visualize and understand the switching behavior. Finally, the opportunities and challenges of further utilizing multiparametric AFM to explore the electron transport mechanisms in biomemristors are presented.

Shi, Chenyang↗

Photothermal Atomic Force Microscopy Coupled with Infrared Spectroscopy (AFM-IR) Analysis of High Extinction Coefficient Materials: A Case Study with Silica and Silicate Glasses

Photothermal atomic force microscopy coupled with infrared spectroscopy (AFM-IR) brings significant value as a spatially resolved surface analysis technique for disordered oxide materials such as glasses, but additional development and fundamental understanding of governing principles is needed to interpret AFM-IR spectra, since the existing theory described for organic materials does not work for materials with high extinction coefficients for infrared (IR) absorption. This paper describes theoretical calculation of a transient temperature profile inside the IR-absorbing material considering IR refraction at the interface as well as IR adsorption and heat transfer inside the sample. Furthermore, this calculation explains the differences in peak positions and amplitudes of AFM-IR spectra from those of specular reflectance and extinction coefficient spectra. It also addresses the information depth of the AFM-IR characterization of bulk materials. AFM-IR applied to silica and silicate glass surfaces has demonstrated novel capability of characterizing subsurface structural changes and surface heterogeneity due to mechanical stresses from physical contacts, as well as chemical alterations manifested in surface layers through aqueous corrosion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of biofilm assembly by large area automated AFM

Biofilms are complex microbial communities critical in medical, industrial, and environmental contexts. Understanding their assembly, structure, genetic regulation, interspecies interactions, and environmental responses is key to developing effective control and mitigation strategies. While atomic force microscopy (AFM) offers critically important high-resolution insights on structural and functional properties at the cellular and even sub-cellular level, its limited scan range and labor-intensive nature restricts the ability to link these smaller scale features to the functional macroscale organization of the films. We begin to address this limitation by introducing an automated large area AFM approach capable of capturing high-resolution images over millimeter-scale areas, aided by machine learning for seamless image stitching, cell detection, and classification. Large area AFM is shown to provide a very detailed view of spatial heterogeneity and cellular morphology during the early stages of biofilm formation which were previously obscured. Using this approach, we examined the organization of Pantoea sp. YR343 on PFOTS-treated glass surfaces. Our findings reveal a preferred cellular orientation among surface-attached cells, forming a distinctive honeycomb pattern. Detailed mapping of flagella interactions suggests that flagellar coordination plays a role in biofilm assembly beyond initial attachment. Additionally, we use large-area AFM to characterize surface modifications on silicon substrates, observing a significant reduction in bacterial density. This highlights the potential of this method for studying surface modifications to better understand and control bacterial adhesion and biofilm formation.

59 BASIC BIOLOGICAL SCIENCES↗

AFM Slip Length Measurements for Water at Selected Phyllosilicate Surfaces

Most reported slip length measurements have been made at the surfaces of synthetic materials and modified synthetic materials. In contrast, few slip length measurements at the surface of unmodified natural mineral surfaces have been reported. In this regard, flow at the silica face surfaces of the phyllosilicate minerals, talc and mica, was considered. A slip boundary condition was expected at the nonpolar hydrophobic silica surface of talc leading to enhanced flow, and a no-slip boundary condition was expected at the hydrophilic silica surface of mica. Atomic force microscopy (AFM) slip length measurements were made at the talc and mica surfaces. The slip length results for the hydrophobic silica surface of talc were contrasted to the results for the hydrophilic silica surface of mica (no-slip flow). The results are discussed based on molecular dynamics simulations (MDS), as reported in the literature, and AFM images of surface nanobubbles. For nonpolar hydrophobic surfaces (such as talc), it is doubtful that the MDS interfacial water structure and the water exclusion zone (3.2 Å) account for the AFM slip flow with slip lengths as great as 95 nm. Rather, a better explanation for the AFM slip flow condition is based on reduced interfacial viscosity due to the presence of dissolved gas and the accommodation of pancake nanobubbles at the talc surface having a height dimension of magnitude similar to the slip length.

42 ENGINEERING↗

AFM Microcantilever With a Collocated AlN Sensor-Actuator Pair: Enabling Efficient Q-Control for Dynamic Imaging

This manuscript presents a novel microcantilever with an embedded piezoelectric sensor-actuator pair for dynamic atomic force microscopy (AFM). The transducer pair is constructed from a two-layered AlN stack. Stacking the piezoelectric transducers in this manner leads to a minimal feedthrough from actuation to sense electrode, granting a high dynamic range frequency response for dynamic mode AFM. The cantilever's design allows for dual mode operation at 1 st and 2 nd resonance modes. High resolution tapping mode imaging results are reported, while the cantilever is operated at these modes. A feedback control loop is used to modify quality factor of the 1 st mode of the cantilever, using a positive position feedback (PPF) controller. Here, a faster response time is achieved by reducing the Q-factor, enabling the cantilever to track the topography at a higher scan rate. Results of bimodal AFM imaging are reported, using amplitude changes of the 1 st mode for surface topography, while material properties are encoded in phase changes of the 2 nd mode.

47 OTHER INSTRUMENTATION↗

Microfibril orientation and compositional heterogeneity in fiber and vessel cell walls of poplar xylem studied by AFM-IR and SFG spectroscopy

Understanding the structural organization of cellulose microfibrils (CMFs) within individual plant cell walls is essential for connecting cell wall architecture to its mechanical and physiological functions. However, due to the complex hierarchical structure and nanoscale heterogeneity of cell walls, it remains technically challenging to resolve detailed compositional and orientational information at subcellular levels of individual cell walls. This study investigates the internal 3D structure, chemical composition, and sublayer organization of fiber and vessel cell walls in the xylem tissue of a two-year-old field-grown hybrid poplar tree (Populus alba × P. glandulosa) using photothermal atomic force microscopy coupled with infrared spectroscopy (AFM-IR) and sum frequency generation (SFG) hyperspectral microscopy. AFM-IR provided nanoscale chemical imaging, revealing localized compositional heterogeneity, including variations between adjacent cell walls and transitional layers beyond the traditional S1, S2, and S3 sublayers. SFG microscopy revealed that CMFs in fiber walls are highly aligned along the stem axis, consistent with their role in mechanical support, while vessel cell walls exhibited slightly tilted CMFs, reflecting their function in hydraulic transport. Together, these results offer new insights into cell-type-specific CMF organization and compositional gradients in hybrid poplar xylem. These findings highlight the structural and chemical complexity of secondary cell walls in woody plants and demonstrate the value of AFM-IR and SFG spectroscopy in elucidating plant cell wall architecture.

60 APPLIED LIFE SCIENCES↗

Nanoscale Consequences of Irradiation Investigated by RAD-AFM (Final Report)

To assess the feasibility of measuring material property changes induced by ion irradiation one pristine and three legacy HT-9 samples were sectioned and polished. The polish protocol was first optimized using a pristine unirradiated HT-9 sample before polishing the ion irradiated samples as the spot size was small and repeated polishing could remove the ion irradiated region entirely. AFM tapping mode was used to assess the surface quality after each polish. AFM based hardness mapping was optimized for new diamond tips specifically for use with the HT-9 samples to compensate for differences in grain size, precipitates, and heterogeneity of hardness relative to past samples. In addition, a hardness calibration protocol was developed using NIST copper, nickel, and steel reference materials. Co-located SEM-EDS and AFM analysis was used to verify the ion irradiated edge using the silver/tungsten coating as a fiducial mark. Once benchmarked, the hardness across the ion irradiated cross section, a comparison of bulk hardness according to neutron irradiation, and the hardness of the ion irradiated surface edge was measured.

36 MATERIALS SCIENCE↗

H 2 Pc and pentacene on Cu(110)-(2×1)O: A combined STM and nc-AFM study

Scanning tunneling microscopy (STM) and non-contact atomic force microscopy (nc-AFM) with a CuO tip is used to investigate adsorption of metal-free phthalocyanine (H 2 Pc) and pentacene on the Cu(110)-(2×1)O striped-phase reconstructed surface. We show that the combination of STM and nc-AFM is necessary to reveal the detailed adsorption geometry, necessary for interpreting the observed STM contrast. Comparison of the nc-AFM images with simulations shows that some of the H 2 Pc molecules are deformed out-of-plane on this surface, while pentacene retains its molecular geometry regardless of adsorption site. Our research highlights how the stiffness of CuO tips makes it possible to probe the structure of organic semiconductor / metal interfaces.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A combined SECM and electrochemical AFM approach to probe interfacial processes affecting molecular reactivity at redox flow battery electrodes

Redox flow batteries are attractive technologies for grid energy storage since they use solutions of redox-active molecules that enable a superior scalability and the decoupling of power and energy density. However, the reaction mechanisms of the redox active components at RFB electrodes are complex, and there is currently a pressing need to understand how interfacial processes impact the kinetics and operational reversibility of RFB systems. Here, we developed a combined electrochemical imaging methodology rooted in scanning electrochemical microscopy (SECM) and atomic force microscopy (AFM) for exploring the impact of electrode structure and conditioning on the electron transfer properties of model redox-active dialkoxybenzene derivatives, 2,5-di-tert-butyl-1,4-bis(2-methoxyethoxy)benzene (C1) and 2,3-dimethyl-1,4-dialkoxybenzene (C7). Using AFM and secondary-ion mass spectrometry (SIMS), we observed the formation of interfacial films with distinct mechanical properties compared to those of cleaved graphitic surfaces, and exclusively during reduction of electrogenerated radical cations. These films had an impact on the median rate and distribution of the electron transfer rate constant at the basal plane of multilayer and single layer graphene electrodes, displaying kinetically-limited values that did not yield the activation expected per the Butler–Volmer model with a transfer coefficient ~0.5. These changes were dependent on redoxmer structure: furthermore, SECM showed strong attenuation of C7 kinetics by a surface layer on MLG and SLG, while C1 kinetics were only affected by SLG. SECM and AFM results together show that these limiting films operate exclusively on the basal plane of graphite, with the edge plane showing a relative insensitivity to cycling and operation potential. Ultimately, this integrated electrochemical imaging methodology creates new opportunities to understand the unique role of interfacial processes on the heterogeneous reactivity of redoxmers at electrodes for RFBs, with a future role in elucidating phenomena at high active concentrations and spatiotemporal variations in electrode dynamics.

25 ENERGY STORAGE↗

Assessment of AFM - KPFM and SSRM for Measuring and Characterizing Materials Aging Processes

Atomic Force Microscopy (AFM), in conjunction with Peak Force Kelvin Probe Force Microscopy (PF-KPFM) and Peak Force Scanning Spreading Resistance Microscopy (PF-SSRM), was used to assess changes on thin metal films that underwent accelerated aging. The AFM technique provides a relatively easy, non-destructive methodology that does not require high-vacuum facilities to obtain nanometer-scale spatial resolution of surface chemistry changes. Surface morphology, roughness, contact potential difference, and spreading resistance were monitored to qualitatively identify effects of aging-morphology changes and oxidation of Au, Al, Cu thin film standards as well as diffusion of CuAu and AlAu thin film stacks at 65C under dried nitrogen flow conditions. AFM PF-KPFM and PF-SSRM modes have been exercised, refined and have proven to be viable and necessary early aging detection tools.

36 MATERIALS SCIENCE↗

Comparison of EBSD, DIC, AFM, and ECCI for active slip system identification in deformed Ti-7Al

The use of SEM-DIC, AFM, ECCI, and HR-EBSD to characterize slip-system activity was assessed on the same material volume of Ti-7Al. This study presents a robust comparison of the various methods for the first time, including an assessment of their advantages and disadvantages, and how they can be used effectively in a complementary fashion. The analysis of the different approaches was carried out in a blind, round-robin manner at three different universities. A Ti-7Al specimen was deformed in uniaxial tension to approximately 3% axial strain, and the active slip systems were independently identified using (i) trace analysis; (ii) in-SEM digital image correlation, (iii) observations of residual dislocations from ECCI, and (iv) long-range rotation gradients through HR-EBSD, with consistent trace identification in all cases. Displacement data from AFM was used to augment SEM-DIC displacement data by providing complementary out-of-plane displacement information. Furthermore, short-range dislocation gradients (measured by DIC) provided insight into the residual geometrically necessary dislocation (GND) content, and was consistent with the GND content extracted from EBSD data and ECCI images, confirming the presence of residual GNDs on the dominant slip systems resulting in visible slip bands. Furthermore, these approaches can be used in tandem to provide multi-modal information on slip band identification, strain and orientation gradients, out-of-plane displacements, and the presence of GNDs and SSDs, all of which can be used to inform and validate the development of dislocation-based crystal plasticity and strain gradient models.

36 MATERIALS SCIENCE↗

Synthesis‐Related Nanoscale Defects in Mo‐Based Janus Monolayers Revealed by Cross‐Correlated AFM and TERS Imaging

2D Janus transition metal dichalcogenides (TMDs) are promising candidates for various applications including non-linear optics, energy harvesting, and catalysis. These materials are usually synthesized via chemical conversion of pristine TMDs. Nanometer-scale characterization of the obtained Janus materials’ morphology and local composition is crucial for both the synthesis optimization and the future device applications. In this work, we present the results of cross-correlated atomic force microscopy (AFM) and tip-enhanced Raman spectroscopy (TERS) study of Janus monolayers synthesized by the hydrogen plasma-assisted chemical conversion of MoSe 2 and MoS 2 . We demonstrate that the choice of both the growth substrate and the starting TMD influences the residual strain, thereby shaping the nanoscale morphology of the resulting Janus material. Furthermore, by employing TERS imaging, we show the presence of nanoscale islands (≈20 nm across) of MoSe 2 - ${\mathrm{Mo}}_{{\mathrm{Se}}}^{\mathrm{S}}$ (MoS 2 -${\mathrm{Mo}}_{\mathrm{S}}^{{\mathrm{Se}}}$) vertical heterostructures originating from the bilayer nanoislands in the precursor monolayer crystals. The understanding of the origins of nanoscale defects in Janus TMDs revealed in this study can help with further optimization of the Janus conversion process towards uniform and wrinkle-/crack-free Janus materials. Moreover, this work shows that cross-correlated AFM and TERS imaging is a powerful and accessible method for studying nanoscale composition and defects in Janus TMD monolayers.

2D materials↗

The anion exchange properties of AFm (hydrocalumite-group) minerals defined from solubility experiments and crystallographic information

Solubility experiments with binary series of OH-, Cl-, SO{sub 4}- and CO{sub 3}-AFm were re-examined with a non-ideal, multicomponent solid solution model. The electrical double layer on the mineral's outer surface, which neutralizes about 5% of the anionic charge, can be included. The choice of the end-members in the solid solution and the reaction formulation can help to eliminate the ‘non-ideality’ for OH-SO{sub 4} and Cl-OH exchange. CO{sub 3}-Cl-OH exchange is not ideal in the solubility experiments, nor can it be, because the mineral volume is not a linear combination of the end-members. The solubilities of the end-members are related to the anion charge and inversely to the anion-layer thickness. OH is part of the anion-charge, even when a pure, other anion form is the target of the synthesis. Pure OH-AFm is unstable and converts into hydrogarnet and portlandite, depending on the precipitation rate of hydrogarnet.

36 MATERIALS SCIENCE↗

Electrolyte–Electrocatalyst Interfacial Effects of Polymeric Materials for Tandem CO 2 Capture and Conversion Elucidated Using In Situ Electrochemical AFM

Integrating CO 2 capture and electrochemical conversion has been proposed as a strategy to reduce the net energy required for CO 2 regeneration in traditional CO 2 capture and conversion schemes and can be coupled with carbon-free renewable electricity. Polyethylenimine (PEI)-based materials have been previously studied as CO 2 capture materials and can be integrated in these reactive capture processes. PEI-based electrolytes have been found to significantly increase the CO 2 loading, and impact selectivity and rate of product formation when compared to the conventional aqueous electrolytes. However, the influence of these materials at the catalyst–electrode interface is currently not well understood. In this study, PEI-based electrolytes were prepared and their impact on the morphology of a silver electrode performing electrochemical CO 2 reduction (CO 2 R) was studied using in situ electrochemical atomic force microscopy (EC-AFM). The presence of PEI on the electrode surface could be distinguished based on nanomechanical properties (DMT modulus), and changes were observed as negative polarization was applied, revealing a reorganization of the PEI chains due to electrostatic interactions. These changes were impacted by the electrolyte composition, including the addition of supporting electrolyte KHCO 3 salt, as well as CO 2 captured by the PEI-based electrolyte, which minimized the change in surface mechanical properties and degree of PEI alignment on the electrode surface. The changes in surface mechanical properties were also dependent on the PEI polymer length, with higher molecular weight PEI showing different reconfiguration than the shorter polymer brushes. The study highlights that the choice of polymer material, the electrolyte composition, and CO 2 captured impact the nearelectrode environment, which has implications for CO 2 R, and presents EC-AFM as a new tool that can be used to probe the dynamic behavior of these interfaces during electrocatalysis.

36 MATERIALS SCIENCE↗

AFM-IR and s-SNOM-IR measurements of chemically addressable monolayers on Au nanoparticles

The performance of catalysts depends on their nanoscale properties, and local variations in structure and composition can have a dramatic impact on the catalytic reactivity. Therefore, probing the localized reactivity of catalytic surfaces using high spatial resolution vibrational spectroscopy, such as infrared (IR) nanospectroscopy and tip-enhanced Raman spectroscopy, is essential for mapping their reactivity pattern. Two fundamentally different scanning probe IR nanospectroscopy techniques, namely, scattering-type scanning near-field optical microscopy (sSNOM) and atomic force microscopy-infrared spectroscopy (AFM-IR), provide the capabilities for mapping the reactivity pattern of catalytic surfaces with a spatial resolution of ~20 nm. Herein, we compare these two techniques with regard to their applicability for probing the vibrational signature of reactive molecules on catalytic nanoparticles. For this purpose, we use chemically addressable self-assembled molecules on Au nanoparticles as model systems. We identified significant spectral differences depending on the measurement technique, which originate from the fundamentally different working principles of the applied methods. While AFM-IR spectra provided information from all the molecules that were positioned underneath the tip, the s-SNOM spectra were more orientation-sensitive. Due to its field-enhancement factor, the s-SNOM spectra showed higher vibrational signals for dipoles that were perpendicularly oriented to the surface. The s-SNOM sensitivity to the molecular orientation influenced the amplitude, position, and signal-to-noise ratio of the collected spectra. Ensemble-based IR measurements verified that differences in the localized IR spectra stem from the enhanced sensitivity of s-SNOM measurements to the adsorption geometry of the probed molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct measurement of storage and loss behavior in AFM force–distance experiments using the modified Fourier transformation

Force–distance curve experiments are commonly performed in atomic force microscopy (AFM) to obtain the viscoelastic characteristics of materials, such as the storage and loss moduli or compliances. The classic methods used to obtain these characteristics consist of fitting a viscoelastic material model to the experimentally obtained AFM data. Here, we demonstrate a new method that utilizes the modified discrete Fourier transform to approximate the storage and loss behavior of a material directly from the data, without the need for a fit. Additionally, one may still fit a model to the resulting storage and loss behavior if a parameterized description of the material is desired. In contrast to fitting the data to a model chosen a priori, departing from a model-free description of the material's frequency behavior guides the selection of the model, such that the user may choose the one that is most appropriate for the particular material under study. To this end, we also include modified Fourier domain descriptions of commonly used viscoelastic models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗