Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AEP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

FLOWERS AEP: An Analytical Model for Wind Farm Layout Optimization

Annual energy production (AEP) is commonly used in objective functions for wind farm layout optimization. AEP is proportional to wind farm power production integrated over an annual distribution of free-stream wind conditions. Physics-based estimates of wind farm power production typically rely on low-fidelity engineering wake models that approximate the steady-state wind farm flow field. AEP estimates are then obtained by performing independent simulations for discrete wind conditions and using rectangular quadrature to account for each condition's expected frequency of occurrence. Depending on the number of simulated discrete wind conditions, this numerical integral could be hampered by poor accuracy or high computational costs. The FLOWERS AEP model instead poses an analytical integral of the engineering wake model over the variable wind conditions, yielding a closed-form, analytical function for wind farm AEP. This paper derives the analytical functions for FLOWERS AEP and its derivatives with respect to turbine position, which are useful for gradient-based wind farm layout optimization, in nondimensional form. We then analyze the benefits of the FLOWERS AEP model over conventional reference models, focusing on its low cost, adequate wake loss predictions, and smooth design space. Although the FLOWERS approach is found to predict the exact value of AEP with some error relative to the reference model (within 14% on average), it dramatically reduces computation time by an order of magnitude, produces a qualitatively similar design space at relatively low resolution, and yields comparable optimal layouts. This significant speed improvement is critical in layout optimization applications, where determining an optimal layout in an efficient manner is more important than precise AEP prediction.

17 WIND ENERGY↗

Efficient wind farm layout optimization with the FLOWERS AEP model and analytic gradients

Wind farm layout optimization (WFLO) studies often aim to maximize the annual energy production (AEP) of a wind farm by choosing an arrangement of turbines that minimizes wake interactions. One way to reduce the cost of WFLO studies is by using more computationally efficient AEP models. The cost of standard AEP modeling approaches, based on the numerical integration of low-fidelity engineering wake models, scales poorly with the number of simulated discrete wind conditions. A second way to reduce cost when using a gradient-based algorithm is to supply exact gradient information instead of finite-difference estimates. However, analytical functions for the derivatives of AEP with respect to turbine positions are not always available in the conventional modeling approach. FLOWERS is a computationally inexpensive, analytical model for wind farm AEP that is specifically developed for WFLO applications. In this paper, we analyze the performance of the FLOWERS AEP model with analytic gradients in a layout optimization study compared with a reference optimization framework across three wind farm case studies. We find that the FLOWERS-based approach reduces computation time by a factor of 50–4000 and improves optimal AEP by about 0.3% with less than half of the variability in AEP across instances with randomized initial conditions. We also find the optimal layouts to be insensitive to model parameter tuning, making FLOWERS-based layout optimization a streamlined, user-friendly approach.

17 WIND ENERGY↗

How Wrong Can the Operational AEP Uncertainty Estimate Be When We Ignore the Correlations Between the Uncertainty Components?

Calculations of wind farm annual energy production (AEP) on operational data are essential for a variety of financial transactions during the life of wind plants. The AEP estimate is associated with an uncertainty value, which is calculated by combining contributions connected to on-site measurements, long-term reference measurements, losses, regression, windiness adjustment, and wind resource interannual variability. Although very limited documentation on the topic exists, the conventional approach currently used by the wind energy community to assess the uncertainty connected to the operational AEP estimate assume that the different uncertainty components are uncorrelated and therefore calculates the overall uncertainty with a sum of squares approach. In this analysis, we contrast the traditional technique to estimate the overall AEP uncertainty by ignoring the correlation between its different components with a novel Monte Carlo based approach, which can instead take into account the correlation between different uncertainty categories. We consider monthly operational data from 472 wind farms from the Energy Information Administration (EIA) 923 database to assess the difference between the two approaches. Long-term wind speed data needed for the AEP assessment are taken from three reanalysis products: the Modern-Era Retrospective analysis for Research and Applications v2 (MERRA-2), the European Reanalysis Interim (ERA-interim), and the National Centers for Environmental Prediction v2 (NCEP-2). The results of the Monte Carlo approach show that three pairs of AEP uncertainty components do show a statistically significant correlation: the uncertainty connected with wind resource inter-annual variability is positively correlated with the one related to the windiness correction and negatively correlated with the one due to the regression, and the wind measurement uncertainty is positively correlated with the regression uncertainty. All these correlations, which are found between uncertainty components which are not only part of an operational analysis, but also of a wind resource assessment, are currently ignored in the conventional techniques used as industry standard. We further investigate the causes of these correlations, in terms of common dependencies of different uncertainty components on wind resource variability, number of data points, and quality of the regression between wind speed and energy production data. Next, we quantify the error in the current industry standard technique, in terms of the percentage difference in total uncertainty calculated with the two considered approaches, for all the analyzed wind farms. We find a mean absolute percentage difference of about 6%, with the largest differences being greater than 20%. The data clearly confirm that ignoring the actual correlation between the uncertainty components can lead to large errors in the assessment of the operational AEP uncertainty, and the proposed Monte Carlo approach should be preferred.

Monte Carlo↗

Maximization of the annual energy production of wind power plants by optimization of layout and yaw-based wake control: Maximization of wind plant AEP by optimization of layout and wake control

This paper presents a wind plant modeling and optimization tool that enables the maximization of wind plant annual energy production (AEP) using yaw-based wake steering control and layout changes. The tool is an extension of a wake engineering model describing the steady-state effects of yaw on wake velocity profiles and power productions of wind turbines in a wind plant. To make predictions of a wind plant's AEP, necessary extensions of the original wake model include coupling it with a detailed rotor model and a control policy for turbine blade pitch and rotor speed. This enables the prediction of power production with wake effects throughout a range of wind speeds. We use the tool to perform an example optimization study on a wind plant based on the Princess Amalia Wind Park. In this case study, combined optimization of layout and wake steering control increases AEP by 5%. The power gains from wake steering control are highest for region 1.5 inflow wind speeds, and they continue to be present to some extent for the above-rated inflow wind speeds. The results show that layout optimization and wake steering are complementary because significant AEP improvements can be achieved with wake steering in a wind plant layout that is already optimized to reduce wake losses.

17 WIND ENERGY↗

Gaussian FLOWERS: Wind-rose-based analytical integration of Gaussian wake model for extremely fast AEP estimation

A major cost in the study of wind farm layout optimization is the repeated evaluation of the annual energy production (AEP). The current approach to estimating AEP requires a large set of flow simulations to be performed that cover each discrete wind speed and direction combination contained within the wind rose, followed by a probability-weighted sum of the power production resulting from each simulation. Even with inexpensive engineering wake models, this numerical integration scheme can lead to high computational costs. In this paper, we derive an analytical formulation for estimating farm AEP across every wind direction, based on a Gaussian wake velocity model, which reduces the number of wind farm simulations to a single function evaluation. As a result, we find that the Gaussian-FLOWERS approach reduces the time for AEP calculations by more than two orders of magnitude with a small trade-off in accuracy when compared to a conventional approach. This massive reduction in computation cost is useful to reduce overall costs in wind farm layout optimization studies.

17 WIND ENERGY↗

AEP Ohio gridSMART Demonstration Project Real-Time Pricing Demonstration Analysis

This report contributes initial findings from an analysis of significant aspects of the gridSMART® Real-Time Pricing (RTP) – Double Auction demonstration project. Over the course of four years, Pacific Northwest National Laboratory (PNNL) worked with American Electric Power (AEP), Ohio and Battelle Memorial Institute to design, build, and operate an innovative system to engage residential consumers and their end-use resources in a participatory approach to electric system operations, an incentive-based approach that has the promise of providing greater efficiency under normal operating conditions and greater flexibility to react under situations of system stress. The material contained in this report supplements the findings documented by AEP Ohio in the main body of the gridSMART report. It delves into three main areas: impacts on system operations, impacts on households, and observations about the sensitivity of load to price changes.

Widergren, Steven E.↗

The Ohio River Valley CO2 Storage Project AEP Mountaineer Plan, West Virginia

This report includes an evaluation of deep rock formations with the objective of providing practical maps, data, and some of the issues considered for carbon dioxide (CO{sub 2}) storage projects in the Ohio River Valley. Injection and storage of CO{sub 2} into deep rock formations represents a feasible option for reducing greenhouse gas emissions from coal-burning power plants concentrated along the Ohio River Valley area. This study is sponsored by the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL), American Electric Power (AEP), BP, Ohio Coal Development Office, Schlumberger, and Battelle along with its Pacific Northwest Division. An extensive program of drilling, sampling, and testing of a deep well combined with a seismic survey was used to characterize the local and regional geologic features at AEP's 1300-megawatt (MW) Mountaineer Power Plant. Site characterization information has been used as part of a systematic design feasibility assessment for a first-of-a-kind integrated capture and storage facility at an existing coal-fired power plant in the Ohio River Valley region--an area with a large concentration of power plants and other emission sources. Subsurface characterization data have been used for reservoir simulations and to support the review of the issues relating to injection, monitoring, strategy, risk assessment, and regulatory permitting. The high-sulfur coal samples from the region have been tested in a capture test facility to evaluate and optimize basic design for a small-scale capture system and eventually to prepare a detailed design for a capture, local transport, and injection facility. The Ohio River Valley CO{sub 2} Storage Project was conducted in phases with the ultimate objectives of demonstrating both the technical aspects of CO{sub 2} storage and the testing, logistical, regulatory, and outreach issues related to conducting such a project at a large point source under realistic constraints. The site characterization phase was completed, laying the groundwork for moving the project towards a potential injection phase. Feasibility and design assessment activities included an assessment of the CO{sub 2} source options (a slip-stream capture system or transported CO{sub 2}); development of the injection and monitoring system design; preparation of regulatory permits; and continued stakeholder outreach.

01 COAL, LIGNITE, AND PEAT↗

Customer Engagement in AEP gridSMART Residential Transactive System

— In 2013, AEP Ohio (AEP) operated a 5-minute real-time price (RTP) electricity market system on 4 distribution feeders as part of their gridSMART® demonstration project. The RTP households were billed for their electricity usage according to an RTP tariff approved by the Public Utility Commission of Ohio. They were given the incentive that their annual bill would be no greater than if they were on the flat-rate tariff, but they had financial incentives to shift consumption from high price periods to low price periods. Incentives were also available for response under high prices from local events, such as reaching the distribution feeder capacity or a critical peak pricing event. An analysis of this transactive system experiment was completed in early 2014. This paper describes the incentive provided to the customer, the nature of their interaction with the smart thermostat that provided automated response to the transactive signal, and their level of satisfaction with the program.

Widergren, Steven E.↗

Vapor liquid equilibrium of pure and aqueous Methyl diethanolamine (MDEA), 2-Dimethylmonoethanolamine (DMMEA), N-Methylmonoethanolamine (MMEA) and 1-(2-Aminoethyl)piperazine (AEP): Experimental results and modeling

This work presents new vapor-liquid data for the pure components 2-dimethylmonoethanolamine (DMMEA) and N-methylethanolamine (MMEA) and for the binary systems of aqueous methyldiethanolamine (MDEA), DMMEA, MMEA, and 1-(2-aminoethyl)piperazine (AEP). New Antoine models are developed for the pure component systems, and new and improved NRTL models for the binary systems. In the model development, together with new data from this work, all available data on VLE, excess heat of mixing, H E , freezing point depression, and specific heat were gathered, evaluated and used selectively for parameter optimization. Emphasis has been put on a best possible representation of amine volatility to enable reasonable predictions of amine emissions from absorption plants and to form a basis for subsequent models of ternary systems with CO 2 . In conclusion, model predictions are compared with experimental results and other models, source by source, and the overall results are satisfactory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Ohio River Valley CO2 Storage Project AEP Mountaineer Plant, West Virginia Numerical Simulation and Risk Assessment Report

A series of numerical simulations of carbon dioxide (CO{sub 2}) injection were conducted as part of a program to assess the potential for geologic sequestration in deep geologic reservoirs (the Rose Run and Copper Ridge formations), at the American Electric Power (AEP) Mountaineer Power Plant outside of New Haven, West Virginia. The simulations were executed using the H{sub 2}O-CO{sub 2}-NaCl operational mode of the Subsurface Transport Over Multiple Phases (STOMP) simulator (White and Oostrom, 2006). The objective of the Rose Run formation modeling was to predict CO{sub 2} injection rates using data from the core analysis conducted on the samples. A systematic screening procedure was applied to the Ohio River Valley CO{sub 2} storage site utilizing the Features, Elements, and Processes (FEP) database for geological storage of CO{sub 2} (Savage et al., 2004). The objective of the screening was to identify potential risk categories for the long-term geological storage of CO{sub 2} at the Mountaineer Power Plant in New Haven, West Virginia. Over 130 FEPs in seven main classes were assessed for the project based on site characterization information gathered in a geological background study, testing in a deep well drilled on the site, and general site conditions. In evaluating the database, it was apparent that many of the items were not applicable to the Mountaineer site based its geologic framework and environmental setting. Nine FEPs were identified for further consideration for the site. These FEPs generally fell into categories related to variations in subsurface geology, well completion materials, and the behavior of CO{sub 2} in the subsurface. Results from the screening were used to provide guidance on injection system design, developing a monitoring program, performing reservoir simulations, and other risk assessment efforts. Initial work indicates that the significant FEPs may be accounted for by focusing the storage program on these potential issues. The screening method was also useful in identifying unnecessary items that were not significant given the site-specific geology and proposed scale of the Ohio River Valley CO{sub 2} Storage Project. Overall, the FEP database approach provides a comprehensive methodology for assessing potential risk for a practical CO{sub 2} storage application. An integrated numerical fate and transport model was developed to enable risk and consequence assessment at field scale. Results show that such an integrated modeling effort would be helpful in meeting the project objectives (such as site characterization, engineering, permitting, monitoring and closure) during different stages. A reservoir-scale numerical model was extended further to develop an integrated assessment framework which can address the risk and consequence assessment, monitoring network design and permitting guidance needs. The method was used to simulate sequestration of CO{sub 2} in moderate quantities at the Mountaineer Power Plant. Results indicate that at the relatively low injection volumes planned for pilot scale demonstration at this site, the risks involved are minor to negligible, owing to a thick, low permeability caprock and overburden zones. Such integrated modeling approaches coupled with risk and consequence assessment modeling are valuable to project implementation, permitting, monitoring as well as site closure.

20 FOSSIL-FUELED POWER PLANTS↗

Role of Early Proctoscopy in Predicting Late Symptomatic Proctitis After External Radiation Therapy for Prostate Carcinoma

Purpose: To determine whether acute radiation-proctitis, diagnosed by proctoscopy after radiation therapy for prostate cancer, can predict late clinical proctitis. Methods and Materials: A prospective study of 130 patients who underwent external radiation therapy (RT) for stage T1 to T4 prostate cancer between 1997 and 2008 was performed. Treatments were conventional (2-dimensional [2D]) in 61 patients and 3D conformal in 69, with a median target dose of 72 Gy (70-74 Gy). Within 1 week after RT, proctoscopy was performed to detect possible acute endoscopic proctitis (AEP). Acute clinical proctitis (ACP) and late clinical proctitis (LCP) were also evaluated. The median follow-up was 84 months (20-180 months). The influence of AEP and ACP on LCP occurrence was studied using the Cox model controlling for age, dose, prostatectomy, RT technique (2D vs 3D), and hormone therapy. Results: AEP was detected in 15 patients (11.5%) and ACP in 67 (51.5%); in 13 cases (10%) AEP and ACP occurred simultaneously. Thirty-five cases of LCP were recorded. The 5-year probability of developing LCP was highest in patients with AEP and ACP (77%, 95% confidence interval [CI] 53%-94%) and lowest in asymptomatic patients (14%, 95% CI 7%-26%; P<.001). Compared to asymptomatic patients, the 5-year probability also was slightly increased in patients with ACP only (26%, 95% CI 16%-40%; P=.052). In multivariable analysis, the combination of AEP and ACP was the main predictor of LCP: compared to asymptomatic patients, the hazard ratio was 5.6 (2.1-15.2) in patients with AEP plus ACP (P=.001) and 2.1 (0.9-4.9) in those with ACP only (P=.103). Conclusions: In patients with AEP and ACP, the risk of LCP was more than 5-fold increased compared to those who were asymptomatic, while a much smaller increase in risk occurred in patients with ACP only. Early proctoscopy can provide valuable information regarding the likelihood of late proctitis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Expanding on Successful Concepts, Models, and Organization

In her letter to the editor1 regarding our recent Feature Article “Completing the Link between Exposure Science and Toxicology for Improved Environmental Health Decision Making: The Aggregate Exposure Pathway Framework” 2, Dr. von Göetz expressed several concerns about terminology, and the perception that we propose the replacement of successful approaches and models for exposure assessment with a concept. We are glad to have the opportunity to address these issues here. If the goal of the AEP framework was to replace existing exposure models or databases for organizing exposure data with a concept, we would share Dr. von Göetz concerns. Instead, the outcome we promote is broader use of an organizational framework for exposure science. The framework would support improved generation, organization, and interpretation of data as well as modeling and prediction, not replacement of models. The field of toxicology has seen the benefits of wide use of one or more organizational frameworks (e.g., mode and mechanism of action, adverse outcome pathway). These frameworks influence how experiments are designed, data are collected, curated, stored and interpreted and ultimately how data are used in risk assessment. Exposure science is poised to similarly benefit from broader use of a parallel organizational framework, which Dr. von Göetz correctly points out, is currently used in the exposure modeling community. In our view, the concepts used so effectively in the exposure modeling community, expanded upon in the AEP framework, could see wider adoption by the field as a whole. The value of such a framework was recognized by the National Academy of Sciences.3 Replacement of models, databases, or any application with the AEP framework was not proposed in our article. The positive role broader more consistent use of such a framework might have in enabling and advancing “general activities such as data acquisition, organization…,” and exposure modeling was discussed in some detail. Like Dr. von Göetz, we recognized the challenges associated with acceptance of the terminology, definitions, and structure proposed in the paper. To address these challenges, an expert workshop was held in May, 2016 to consider and revise the “basic elements” outlined in the paper. The attendees produced revisions to the terminology (e.g., key events) that align with terminology currently in use in the field. We were also careful in our paper to acknowledge a point raised by Dr. von Göetz, that the term AEP implies aggregation, providing these clarifications: “The simplest form of an AEP represents a single source and a single pathway and may more commonly be referred to as an exposure pathway,”; and “An aggregate exposure pathway may represent multiple sources and transfer through single pathways to the TSE, single sources and transfer through multiple pathways to the target site exposure (TSE), or any combination of these.” These clarifications address the concern that the AEP term is not accurate or logical, and further expands upon the word “aggregate” in a broader context. Our use of AEP is consistent with the definition for “aggregate exposure”, which refers to the combined exposures to a single chemical across multiple routes and pathways.3 The AEP framework embraces existing methods for collection, prediction, organization, and interpretation of human and ecological exposure data cited by Dr. von Göetz. We remain hopeful that wider recognition and use of an organizing concept for exposure information across the exposure science, toxicology and epidemiology communities advances the development of the kind of infrastructure and models Dr. von Göetz discusses. This outcome would be a step forward, rather than a step backward.

exposure science↗

Aryl ether-free polymer electrolytes for electrochemical and energy devices

Anion exchange polymers (AEPs) play a crucial role in green hydrogen production through anion exchange membrane water electrolysis. The chemical stability of AEPs is paramount for stable system operation in electrolysers and other electrochemical devices. Given the instability of aryl ethercontaining AEPs under high pH conditions, recent research has focused on quaternized aryl ether-free variants. The primary goal of this review is to provide a greater depth of knowledge on the synthesis of aryl ether-free AEPs targeted for electrochemical devices. Synthetic pathways that yield polyaromatic AEPs include acid-catalysed polyhydroxyalkylation, metal-promoted coupling reactions, ionene synthesis via nucleophilic substitution, alkylation of polybenzimidazole, and Diels–Alder polymerization. Polyolefinic AEPs are prepared through addition polymerization, ring-opening metathesis, radiation grafting reactions, and anionic polymerization. Discussions cover structure–property–performance relationships of AEPs in fuel cells, redox flow batteries, and water and CO 2 electrolysers, along with the current status of scale-up synthesis and commercialization.

25 ENERGY STORAGE↗

Operational-based annual energy production uncertainty: are its components actually uncorrelated?

Calculations of annual energy production (AEP) from a wind power plant – whether based on preconstruction or operational data – are critical for wind plant financial transactions. The uncertainty in the AEP calculation is especially important in quantifying risk and is a key factor in determining financing terms. A popular industry practice is to assume that different uncertainty components within an AEP calculation are uncorrelated and can therefore be combined as the sum of their squares. We assess the practical validity of this assumption for operational-based uncertainty by performing operational AEP estimates for more than 470 wind plants in the United States, mostly in simple terrain. We apply a Monte Carlo approach to quantify uncertainty in five categories: revenue meter data, wind speed data, regression relationship between density-corrected wind speed (from reanalysis data) and measured wind power, length of long-term-correction data set, and future interannual variability. We identify correlations between categories by comparing the results across all 470 wind plants. We observe a positive correlation between interannual variability and the linearized long-term correction; a negative correlation between wind resource interannual variability and linear regression; and a positive correlation between reference wind speed uncertainty and linear regression. Then, we contrast total operational AEP uncertainty values calculated by omitting and considering correlations between the uncertainty components. We quantify that ignoring these correlations leads to an underestimation of total AEP uncertainty of, on average, 0.1% and as large as 0.5% for specific sites. Although these are not large increases, these would still impact wind plant financing rates; further, we expect these values to increase for wind plants in complex terrain. Based on these results, we conclude that correlations between the identified uncertainty components should be considered when computing the total AEP uncertainty.

17 WIND ENERGY↗

Characterization of Hot Workability of 5052 Aluminum Alloy Based on Activation Energy-Processing Map

In the design of hot forming processes for aluminum alloys, hot processing maps are usually used as a powerful tool for processing parameters optimizations. Although the stability of deformation is considered in conventional hot processing (CHP) maps, the difficulty of deformation, i.e., whether deformation is easy to occur, is not taken into account. Therefore, it is difficult for CHP maps to efficiently and accurately obtain the optimal processing parameters and achieve satisfying hot workability. Hence, in this study, thermal compression tests were performed to investigate the hot forming behavior of 5052 aluminum alloy in the deformation temperature range of 553-733 K and strain rate range of 0.001-1 s{sup −1}. We proposed an activation energy-processing (AEP) map by coupling the CHP map and the activation energy value, and thereby applied it to evaluate the hot workability of 5052 aluminum alloy. In CHP maps, the region with the highest power dissipation efficiency is generally considered to be the best processing region. However, the AEP map shows that materials with satisfying hot workability not only depends on high power dissipation efficiency, but also on low activation energy values. At the strain of 0.7, the optimal hot processing region predicted by the CHP map lies in the temperature range of 583-673 K and strain rate range of 0.001-0.1 s{sup −1}, but that predicted by AEP map locates in the temperature range of 643-733 K and strain rate range of 0.001-0.1 s{sup −1}. Microstructure characterization implies that the optimal processing region predicted by the CHP map presents necklace-like structures, which are non-uniform and unbeneficial for deformation, while that predicted by the AEP map consists of fine, uniform and equiaxed grains. Thus, it is implied that the processing regions predicted by the AEP map are more suitable for forming, i.e., the reasonability of the AEP map is verified.

36 MATERIALS SCIENCE↗

An independent analysis of bias sources and variability in wind plant pre-construction energy yield estimation methods

The wind resource assessment community has long had the goal of reducing the bias between wind plant pre-construction energy yield assessment (EYA) and the observed annual energy production (AEP). This comparison is typically made between the 50% probability of exceedance (P50) value of the EYA and the long-term corrected operational AEP (hereafter OA P50), and is known as the P50 bias. The industry has critically lacked an independent analysis of bias reduction investigated across multiple consultants to identify the greatest sources of uncertainty and variance in the EYA process and the best opportunities for uncertainty reduction. The present study addresses this gap by benchmarking consultant methodologies against each other and against operational data at a scale not seen before in industry collaborations. We consider data from 10 wind plants and evaluate discrepancies between eight consultancies in the steps taken from estimates of gross to net energy. Consultants tend to overestimate the gross energy produced at the turbines and then compensate by further overestimating downstream losses, leading to a mean P50 bias near zero, still with significant variability among the individual wind plants. Within our data sample, we find that consultant estimates of all loss categories, except environmental losses, tend to reduce the project-to-project variability of the P50 bias. The disagreement between consultants, however, remains flat throughout the addition of losses. Finally, we find that differences in consultants’ estimates of project performance can lead to differences up to $10/MWh in the levelized cost of energy for a wind plant.

Todd, Austin C.↗