Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Measurement of 227 Ac impurity in 225 Ac using decay energy spectroscopy

225 Ac is a valuable medical radionuclide for targeted $\alpha$ therapy, but 227 Ac is an undesirable byproduct of an accelerator-based synthesis method under investigation. Sufficient detector sensitivity is critical for quantifying the trace impurity of 227 Ac, with the 227 Ac/ 225 Ac activity ratio predicted to be approximately 0.15% by end-of-bombardment (EOB). Superconducting transition edge sensor (TES) microcalorimeters offer high resolution energy spectroscopy using the normal-to-superconducting phase transition to measure small changes in temperature. By embedding 225 Ac production samples in a gold foil thermally coupled to a TES microcalorimeter we can measure the decay energies of the radionuclides embedded with high resolution and 100% detection efficiency. This technique, known as decay energy spectroscopy (DES), collapses several peaks from $\alpha$ decays into single Q-value peaks. In practice there are more complex factors in the interpretation of data using DES, which we will discuss in this paper. Using this technique we measured the EOB 227 Ac impurity to be (0.142 ± 0.005)% for a single production sample. This demonstration has shown that DES is a useful tool for quantitative measurements of complicated spectra.

07 ISOTOPE AND RADIATION SOURCES↗

A Novel Three-Phase Oak Ridge AC / AC Converter for Wireless Mobility Energy Storage System (WMESS) Connectivity

In this study, a novel three-phase Oak Ridge ac to ac converter is introduced for wireless mobility energy storage system (WMESS) applications for grid support or ancillary service applications. The proposed topology can be used in bidirectional operation between ac grid and ac terminals of energy storage (output of the ESS inverter) by accomplishing unity power factor. Inherent merit of the technology is that it can directly merge ac input 60 Hz grid frequency with the high frequency by superimposing them with the Oak Ridge Converter (ORC) and through the wireless coils. Theoretical and simulation results are provided for 10 kW output power. The functionality of the proposed three-phase system is demonstrated with the coupling coils separated by 6 inches of air gap with the input / output of 277 V AC,RMS . The system overall design is presented, and simulation results demonstrate achieving 3% current total harmonic distortion (THD) and 0.99 power factor (PF) at full load of 10 kW wireless power transfer.

Asa, Erdem↗

Riemannian Optimization Applied to AC Optimal Power Flow: Preprint

The nonlinear, nonconvex AC optimal power flow problem is of growing importance as the nature of the power grid evolves. This problem can be difficult to solve for interior point methods. However, the advent of optimization algorithms over smooth Riemannian manifolds presents an alternative approach. The nonlinear, nonconvex constraints in the AC power flow problem form an embedded submanifold of Euclidean space. In this paper, the authors explore the performance of Riemannian optimization algorithms for the ACOPF problem where the optimization is performed directly on the AC power flow manifold. They demonstrate that these are viable computational alternatives to interior point methods. This is done by using Julia and the packages PowerModels.jl and Manopt.jl.

manifold optimization↗

DC-AC Tool: Fully Automating the Acquisition of AC Power Flow Solution

DC2AC is an automated tool for achieving a converged AC power flow solution from any dispatch, e.g., determined using DC power flow model based optimal power flow. The entire process is free of human interference. It is usually encountered in practice that, even with a DC power flow solution, acquiring the solved AC power flow solution, if exists, sometimes could be a challenging task, especially during the planning stage. It is also difficult to distinguish the unsolvable cases from diverging iterations. Manual adjustments to approach the desired power flow condition has been largely relied on in the past using lots of engineering heuristics. This tool provides a systematic way to first achieve a solvable AC power flow case by modifying the power flow condition, and then try to track the AC power flow solution while gradually removing the adopted changes. If all adopted changes can be completely removed, then the original AC power flow solution is obtained. Otherwise, insights for actionable controls are derived to help operation and planning. Currently, this tool has been implemented in Python using SIEMENS PTI PSS/E as power flow solver, where only adjusting generator terminal voltage set point is considered as an available means to try to turn an unsolved power flow to a solved one. In future, more means should be considered, including the operation of tap-changing transformers, switched shunts and redispatch of active power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MIDAS-DC-AC Tool: Fully Automating the Acquisition of AC Power Flow Solution (MIDAS-DC2AC)

MIDAS DC2AC is an automated tool for achieving a converged AC power flow solution from any dispatch, e.g., determined using DC power flow model based optimal power flow. The entire process is free of human interference. It is usually encountered in practice that, even with a DC power flow solution, acquiring the solved AC power flow solution, if exists, sometimes could be a challenging task, especially during the planning stage. It is also difficult to distinguish the unsolvable cases from diverging iterations. Manual adjustments to approach the desired power flow condition has been largely relied on in the past using lots of engineering heuristics. This tool provides a systematic way to first achieve a solvable AC power flow case by modifying the power flow condition, and then try to track the AC power flow solution while gradually removing the adopted changes. If all adopted changes can be completely removed, then the original AC power flow solution is obtained. Otherwise, insights for actionable controls are derived to help operation and planning. Currently, this tool has been implemented in Python using SIEMENS PTI PSS/E as power flow solver, where only adjusting generator terminal voltage set point is considered as an available means to try to turn an unsolved power flow to a solved one. In future, more means should be considered, including the operation of tap-changing transformers, switched shunts and redispatch of active power.

Tan, Jin↗

Modeling the AC Power Flow Equations with Optimally Compact Neural Networks: Application to Unit Commitment

Nonlinear power flow constraints render a variety of power system optimization problems computationally intractable. Emerging research shows, however, that the nonlinear AC power flow equations can be successfully modeled using neural networks. These neural networks can be exactly transformed into mixed integer linear programs and embedded inside challenging optimization problems, thus replacing nonlinearities that are intractable for many applications with tractable piecewise linear approximations. Such approaches, though, suffer from an explosion of the number of binary variables needed to represent the neural network. Accordingly, this paper develops a technique for training an "optimally compact'' neural network, i.e., one that can represent the power flow equations with a sufficiently high degree of accuracy while still maintaining a tractable number of binary variables. We demonstrate the use of this neural network as an approximator of the nonlinear power flow equations by embedding it in the AC unit commitment problem, transforming the problem from a mixed integer nonlinear program into a more manageable mixed integer linear program. We use the 14-, 57-, and 89-bus networks as test cases and compare the AC-feasibility of commitment decisions resulting from the neural network, DC, and linearized power flow approximations. Our results show that the neural network model outperforms both the DC and linearized power flow approximations when embedded in the unit commitment problem. The neural network formulation most often selects a feasible unit commitment schedule, and furthermore, it only s

AC power flow↗

A Universal Converter for DC, Single-phase AC, and Multi-phase AC Systems (Final Report)

The goal of this project was to develop a new class of universal power converters that utilize the unique properties of WBG switches, including high reverse voltage blocking and fast switching, to achieve superior performance in universal converters. Some of the features of the proposed converter are as follows: 1) Significantly longer lifetime, higher power density, lower costs associated with bill of materials, and lower shipping, installation, and repair costs compared to the existing WBG-based solutions, 2) Very flexible operation for transferring power between any type of source (dc, single-phase ac, or multi-phase ac) and any type of load (dc, single-phase ac, or multi-phase ac) without using large passive components or additional stages/components, even when the instantaneous values of input and output power are not the same, and 3) High performance operation at all power levels. Considering its advantages and wide range of applications, the proposed converter has the potential to create a new paradigm in power electronics. Among numerous applications of this converter are electric vehicles, wind energy systems, PV systems, industrial motor drives, residential variable frequency drive systems, and nanogrid applications. This project focused on the application of this converter for residential PV, residential motor drive, and industrial motor drive applications, and evaluated the performance of this converter for these applications.

42 ENGINEERING↗

AC to AC Solid State Transformer with Bidirectional Switches

This report details the work of the 3-year project for the AC-to-AC Solid State Transformer with Bidirectional Switches project devoted to developing and demonstrated a Type I Solid State Transformer. This report details the design, fabrication, and evaluation of both three-phase and single-phase versions of this solid state transformer operating as a single module, modules in parallel, and modules in cascade. Additionally, this report details the fabrication and evaluation of custom Silicon Carbide bidirectional switches to enable this topology with a comparison between monolithically integrated bidirectional switches as well as co-packaged back-to-back unidirectional devices. Finally, results for custom-fabricated Fe 4 N/ferrite laminated toroidal cores for high frequency transformers are present.

42 ENGINEERING↗

AC losses of Roebel and CORC ® cables at higher AC magnetic fields and ramp rates

We have measured ReBCO coated conductor-based conductor on round core (CORC ® ) and Roebel cables at 77 K in a spinning magnet calorimeter, which subjected the tapes in the samples to a radial magnetic field of 566 mT (peak) at frequencies up to 120 Hz (272 T s -1 , cyclic average) with an approximately sinusoidal waveform. The samples were oriented such that the field applied to the tapes within the cables was entirely radial, simplifying subsequent analysis. An expression for loss which included hysteretic, flux creep and eddy current losses was fit to both the CORC ® and the Roebel cables. This expression allowed easy comparison of the relative influence of eddy currents and flux creep (or power-law behavior) effects. The loss of both the CORC ® and Roebel cables measured here were seen to be essentially the sum of the hysteretic loss, flux creep effects, and the normal metal eddy current losses of the individual tapes. The losses of these cables were measured at high B × d B /d t with no coupling current loss observed under the present preparation conditions. The influence of flux creep effects on loss were not negligible. The losses of the CORC ® cable per meter of tape were seen to be reduced from the case of a flat tape because of the helical geometry of the tapes.

Physics↗

Unfolder-based single-stage AC-AC conversion system

An power converter includes an unfolder connected to a three-phase source and has an output connection with a positive terminal, a negative terminal and a neutral terminal. The unfolder creates two unipolar piece-wise sinusoidal DC voltage waveforms offset by a half of a period. A three-input converter connected to the unfolder produces a quasi-sinusoidal output voltage across output terminals. Switches of the converter selectively connect the positive, negative and neutral inputs across the output terminals. A PWM controller controls a first duty ratio and a second duty ratio for the converter based on a phase angle of the source and a modulation index generated from an error signal related to a control variable. The duty ratios are time varying with a fundamental frequency of the source. The modulation index relates to output voltage of the converter, peak voltage or current of the source and/or peak current at the output terminals.

Teeneti, Chakridhar Reddy↗

Unfolder-based single-stage AC-AC conversion system

A power converter includes an unfolder connected to a three-phase source and has an output connection with three output terminals. A three-input converter connected to the unfolder produces a quasi-sinusoidal output voltage across converter output terminals. Switches of the converter selectively connect each of the three output terminals across the converter output terminals. A pulse-width modulation controller controls a first duty ratio and a second duty ratio for the converter based on a phase angle of the source and a modulation index generated from an error signal related to a control variable. The duty ratios are time varying at a rate related to a fundamental frequency of the source. The modulation index relates to output voltage of the converter, peak voltage or current of the source and/or peak current at the output terminals.

Teeneti, Chakridhar Reddy↗

Spacetime pq theory for AC and DC electric power systems

The 50/60 Hz alternating current (AC) electric power has been the standard and most flexible energy source powering our modern societies for one and a half centuries since the war of the currents: AC versus direct current (DC). A reactive power concept that was introduced at the beginning of the AC power was very useful for circuit/system analysis, design, control, optimization, and ultimately for more efficient and stable generation, transmission, distribution, and consumption. The initial reactive power theory was based on single-phase sinusoidal AC power to capture inductive and capacitive power that yields to net-zero average power over one fundamental cycle. Soon it was expanded to non-sinusoidal AC power and finally to instantaneous three-phase AC power. However, these reactive power theories remain separate and limited to special cases and have never been consolidated and made valid to all cases. Today, more widespread adoption of power electronics and renewable energy is bringing back DC power into the electric grids. The reactive power concept has never been applied to DC power systems. There is no reactive power in DC power systems according to the existing reactive power theories. Do DC power systems really have no reactive power? Capacitors and inductors are widely used in DC just like in AC power systems. Are they not reactive power components? Why are they different from their AC counterparts? Furthermore, are batteries active or reactive power components? What about active devices like power converters (or inverters) with AC (or DC) on one side and DC (or AC) on the other? Do they generate or consume reactive power? Finally, what about AC and DC hybrid power systems? How to define reactive power in such a complex power system that has a multitude of loads, buses, and sources? Is there reactive power between any two loads, any two buses, or any two sources in a power system and what is the total reactive power in such a complex power system as a whole? As the motivation and goal of this paper to answer the above basic questions, to unify the existing AC reactive power theories and to ultimately provide theoretical and insightful guidance for system analysis, design, control, efficiency, optimization, and operation of complex power systems, a concept of spacetime (both spatial and temporal) active and reactive power (pq) theory—the spatiotemporal aspect of active and reactive power—is developed for both AC and DC power systems. The theoretical definitions and physical meanings of the spacetime reactive power will be developed, and real applications and thought experiments/cases/exercises will be explored and discussed. The developed mathematics to define the active (or real) and reactive (or imaginary) power— p and q respectively by dot (scalar) and cross (vector) products of multi-dimension spacetime vectors and time-space mapping principle/law can have some fundamental implications as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Locoregional Treatment of Glioblastoma With Targeted α Therapy: [213Bi]Bi-DOTA–Substance P Versus [225Ac]Ac-DOTA–Substance P—Analysis of Influence Parameters

Background Glioblastoma (GB) is the most malignant primary brain tumor. Therefore, introduction of new treatment options is critically important. The aim of this study was to assess local treatment with α emitters [ 213 Bi]Bi-DOTA–substance P (SP) and [ 225 Ac]Ac-DOTA-SP. Methods Treatment was performed as salvage therapy in patients with recurrent primary and secondary GB. [ 213 Bi]Bi-DOTA-SP with injected activity 1.85 GBq per cycle was used in 20 primary (48.2 ± 11.8 years old) and in 9 secondary (38.8 ± 10.8 years old) GB patients and [ 225 Ac]Ac-DOTA-SP in 15 primary (45.1 ± 9.9 years old) and in 6 secondary (37.8 ± 6.4 years old) GB patients with a dose escalation scheme (10, 20, and 30 MBq). Results Local treatment with [ 213 Bi]Bi-DOTA-SP and [ 225 Ac]Ac-DOTA-SP was well tolerated with only few adverse effects. There was no statistically significant difference between [ 213 Bi]Bi-DOTA-SP and [ 225 Ac]Ac-DOTA-SP groups in survival parameters. For primary GB, survival parameters of patients treated with [ 213 Bi]Bi-DOTA-SP and [ 225 Ac]Ac-DOTA-SP were as follows(in months): progression-free survival time, 2.7 versus 2.4; OS-d (overall survival from time of diagnosis to death from any cause), 23.6 versus 21.0; OS-t (overall survival from the start of treatment to death from any cause), 7.5 versus 5.0; and OS-r (overall survival from recurrence in primary tumors to death from any cause), 10.9 versus 12.0. Survival parameters of secondary GB patients treated with [ 213 Bi]Bi-DOTA-SP and [ 225 Ac]Ac-DOTA-SP were as follows (in months): progression-free survival time, 5.8 versus 2.4; OS-d, 52.3 versus 65.0; OS-t, 16.4 versus 16.0; and OS-c (overall survival from conversion into secondary GB multiforme to death from any cause), 18.4 versus 36.0. Conclusions The similarity results of 213 Bi or 225 Ac may suggest that the local treatment of brain tumors can be greatly simplified. The experience to date shows that local radioisotope treatment of brain tumors requires further dosimetry studies, taking into account the complexity of biological processes.

Radiology, Nuclear Medicine & Medical Imaging↗

225 Ac-MACROPATATE: A Novel α-Particle Peptide Receptor Radionuclide Therapy for Neuroendocrine Tumors

Neuroendocrine tumors (NETs) express somatostatin receptors (SSTRs) 2 and 5. Modified variants of somatostatin, the cognate ligand for SSTR2 and SSTR5, are used in treatment for metastatic and locoregional disease. Peptide receptor radionuclide therapy with 177 Lu-DOTATATE (DOTA-octreotate), a β-particle–emitting somatostatin derivative, has demonstrated survival benefit in patients with SSTR-positive NETs. Despite excellent results, a subset of patients has tumors that are resistant to treatment, and alternative agents are needed. Targeted α-particle therapy has been shown to kill tumors that are resistant to targeted β-particle therapy, suggesting that targeted α-particle therapy may offer a promising treatment option for patients with 177 Lu-DOTATATE–resistant disease. Although DOTATATE can chelate the clinically relevant α-particle–emitting radionuclide 225 Ac, the labeling reaction requires high temperatures, and the resulting radioconjugate has suboptimal stability. Methods: We designed and synthesized MACROPATATE (MACROPA-octreotate), a novel radioconjugate capable of chelating 225 Ac at room temperature, and assessed its in vitro and in vivo performance. Results: MACROPATATE demonstrated comparable affinity to DOTATATE (dissociation constant, 21 nM) in U2-OS-SSTR2, a SSTR2-positive transfected cell line. 225 Ac-MACROPATATE demonstrated superior serum stability at 37°C over time compared with 225 Ac-DOTATATE. Biodistribution studies demonstrated higher tumor uptake of 225 Ac-MACROPATATE than of 225 Ac-DOTATATE in mice engrafted with subcutaneous H69 NETs. Therapy studies showed that 225 Ac-MACROPATATE exhibits significant antitumor and survival benefit compared with saline control in mice engrafted with SSTR-positive tumors. However, the increased accumulation of 225 Ac-MACROPATATE in liver and kidneys and subsequent toxicity to these organs decreased its therapeutic index compared with 225 Ac-DOTATATE. Conclusion: 225 Ac-MACROPATATE and 225 Ac-DOTATATE exhibit favorable therapeutic efficacy in animal models. Because of elevated liver and kidney accumulation and lower administered activity for dose-limiting toxicity of 225 Ac-MACROPATATE, 225 Ac-DOTATATE was deemed the superior agent for targeted α-particle peptide receptor radionuclide therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗