Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation of hepatocellular carcinoma ablative margins using fused pre- and post-ablation hepatobiliary phase images

Purpose: To retrospectively evaluate the utility of fusion images of pre- and post-ablation hepatobiliary phase (HBP) series to assess the ablation margins after radiofrequency ablation (RFA) of hepatocellular carcinomas (HCCs). Additionally, to identify factors indicative of an adequate ablation margin and predictors of local tumor progression (LTP). Methods: Fifty-nine HCCs in 29 patients were treated by RFA and followed-up for > 1 year (mean 37.9 months). Fusion images of pre- and post-ablation HBP series were created using a non-rigid registration and manual correlation. The ablation margin appearance was classified as ablation margin + (ablation margin completely surrounding the tumor), ablation margin-zero (a partially discontinuous ablation margin without protrusion of HCC), ablation margin—(a partially discontinuous ablation margin with protrusion of HCC), and indeterminate (index tumor was not visible). The minimal ablation margin was measured, and clinical factors were examined to identify other risk factors for LTP. Results: LTP was observed at follow-up in 12 tumors. The mean minimal ablation margin was 3.6 mm. Multivariate analysis revealed that the ablation margin status was the only significant factor (p = 0.028). The cumulative LTP rates (3.3%, 3.3%, and 3.3% at 1, 2, and 3 years, respectively) in 30 ablation margin + nodules were significantly lower (p = 0.006) than those (20.0%, 28.0%, and 32.2% at 1, 2, and 3 years, respectively) in 25 ablation margin-zero nodules. Conclusions: Fusion images enable an early assessment of the ablation efficacy in the majority of HCCs. The ablation margin status is a significant factor for LTP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fluorescent Tissue Assessment of Colorectal Cancer Liver Metastases Ablation Zone: A Potential Real-Time Biomarker of Complete Tumor Ablation

Background: This study aimed to evaluate whether rapid fluorescent tissue examination immediately after colorectal cancer liver metastasis (CLM) ablation correlates with standard pathologic and immunohistochemical (IHC) assessments. Methods: This prospective, National Institutes of Health-supported study enrolled 34 consecutive patients with 53 CLMs ablated between January 2011 and December 2014. Immediately after ablation, core needle sampling of the ablation zone was performed. Tissue samples were evaluated with fluorescent viability (MitoTracker Red) and nuclear (Hoechst) stains. Confocal microscope imaging was performed within 30 min after ablation. The same samples were subsequently fixed and stained with hematoxylin and eosin (H&E). Identified tumor cells underwent IHC staining for proliferation (Ki67) and viability (OxPhos). The study pathologist, blinded to the H&E and IHC assessment, evaluated the fluorescent images separately to detect viable tumor cells. Sensitivity, specificity, and overall concordance of the fluorescent versus H&E and IHC assessments were calculated. Results: A total of 63 tissue samples were collected and processed. The overall concordance rate between the immediate fluorescent and the subsequent H&E and IHC assessments was 94% (59/63). The fluorescent assessment sensitivity and specificity for the identification of tumor cells were respectively 100% (18/18) and 91% (41/45). Conclusions: The study showed a high concordance rate between the immediate fluorescent assessment and the standard H&E and IHC assessment of the ablation zone. Given the documented prognostic value of ablation zone tissue characteristics for outcomes after ablation of CLM, the fluorescent assessment offers a potential intra-procedural biomarker of complete tumor ablation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

DESIGN AND TESTING OF DIMES CARBON ABLATION RODS IN THE DIII-D TOKAMAK

We present the design of ATJ graphite rods developed for ablation experiments under high heat flux (up to 50 MW/m2) in the lower divertor of the DIII-D tokamak, a magnetic plasma confinement device. This work is motivated by the need to test ablation models relevant to carbon-based thermal shields used in high-speed spacecraft atmospheric entries, where the heat fluxes encountered can be comparable to those achieved in the DIII-D divertor plasma. Several different designs for the flowfacing side of the rod are analyzed, including "sharp nose," "blunt," and "concave". The last shape is studied for its potential to lower heat fluxes at the rod surface by increased radiation from trapped neutrals and reduced parallel plasma pressure. We also analyze the possibility of applying a thin (approximately 30 microns) layer of silicon carbide (SiC) to the exposed part of several carbon ablation rods to benchmark its erosion calculations and lifetime predictions. Such calculations are of interest as SiC represents a promising material for both thermal protection systems (TPS) and a fusion plasma-facing material (PFM). Preliminary results from the DIII-D rod ablation experiments are also discussed.

Orlov, Dmitri M.↗

Magnetic-field generation and its effect on ablative Rayleigh–Taylor instability in diffusive ablation fronts

The effects of self-generated magnetic fields on the ablative Rayleigh–Taylor (RT) instability are investigated in the linear regime. The main governing parameters are the Froude number (Fr), which stands for the ratio between ablative convection and acceleration of the target, and the Mach number at the ablation front (Ma), assumed to be small (isobaricity). During the development of the RT instability, magnetic fields are generated due to misalignment between pressure and density gradients (Biermann-battery effect). They accumulate at the section of the ablation front where the Nernst and the plasma velocities cancel each other. The magnetic field modifies the dynamics of the instability through the Righi–Leduc term, which acts as a heat source in the energy equation. It is found that the B fields affect perturbations with short wavelengths up to the most unstable wave in the spectrum. Here, the B field plays a destabilizing role for moderate Froude numbers and becomes stabilizing for large Froude numbers. For plastic ablators, the Fr threshold is found to be Fr = 5.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hyperfine structures and isotopic shifts of uranium transitions using tunable laser spectroscopy of laser ablation plumes

We report isotopic shifts and hyperfine structures of selected U transitions employing tunable spectroscopy viz: laser-induced fluorescence and laser absorption spectroscopy of laser ablation plumes. The laser-produced plasmas were produced during ns laser ablation on a natural U metal which contains 0.7% 235U. Our results show that isotopic shifts between 238U and 235U are entangled with hyperfine structures of 235U. The isotopic ratio obtained using laser-induced fluorescence is affected by optical saturation effect. Time-resolved laser absorption spectroscopy is carried out for evaluating the optical absorption and estimating the hyperfine constants.

(020.3260) Isotope shifts↗

Metabolomic Profiling of Wild-type and Mutant Soybean Root Nodules Using Laser-ablation Electrospray Ionization Mass Spectrometry Reveals Altered Metabolism

The establishment of the nitrogen-fixing symbiosis between soybean and Bradyrhizobium japonicum is complex. In order to document the changes in plant metabolism due to the symbiosis, we utilized laser ablation electrospray ionization mass spectrometry (LAESI-MS) for in situ metabolic profiling of wild-type nodules, nodules infected with a B. japonicum nifH mutant unable to fix nitrogen, nodules doubly infected by both strains, and nodules formed on plants mutated in the stearoyl-acyl carrier protein desaturase (sacpd-c) gene, which were previously shown to have altered nodule ultrastructure. Results showed that the relative abundance of fatty acids, purines, and lipids was significantly changed in response to the symbiosis. The nifH mutant nodules had elevated levels of jasmonic acid (JA), correlating with signs of nitrogen deprivation. Nodules resulting from the mixed inoculant displayed similar, overlapping metabolic distributions within the sectors of effective (fix+) and ineffective (nifH mutant, fix-) endosymbionts. These data are inconsistent with the notion that plant sanctioning is cell autonomous. Nodules lacking sacpd-c displayed an elevation of soyasaponins and organic acids in the central necrotic regions. This study demonstrates the utility of LAESI-MS for high-throughput screening of plant phenotypes. Overall, nodules disrupted in the symbiosis were elevated in metabolites related to plant defense.

Agtuca, Beverly J.↗

Electron temperature and electron number density measurements in laser ablation Z-pinch experiments of Al2O3

Aluminum oxide (Al2O3) plasma was generated using the Ti:Sapphire/Nd:glass laser and Z-pinch pulse-power generator at the University of Nevada, Reno, Nevada Terawatt Facility. To determine the electron temperature, we use the Boltzmann plot method for the transitions (Al III 4d 2D3/2 → 4p 2P1/2) at 451.2564 nm, (Al III 4d 2D5/2 → 4p 2P3/2) at 452.9194 nm, (Al III 4p 2P3/2 → 4s 2S1/2) at 569.6603, and (Al III 4p 2P1/2 → 4s 2S1/2) at 572.2728 nm. Simultaneously, Mach–Zehnder laser interferometry was used to measure the electron number density. We compared simulated spectra obtained from PrismSPECT with electron number density and temperature measurements, and the electron temperature was found to range from 1.8 to 2.8 eV, while the electron number density was found to range from 2.3 × 1017 to 6.9 × 1017 cm−3 early in the pinched plasma formation.

Dutra, E. C.↗

Laser ablation spectrometry for studies of uranium plasmas, reactor monitoring, and spent fuel safety

Nuclear security is one of the defining challenges of our time. Nuclear threats range from deliberate dispersal of radioactive material to contaminate the vital infrastructure to diversion and smuggling of special nuclear material for clandestine nuclear programs and nuclear terrorism, respectively. There is an associated need to develop and sustain the nuclear forensics capabilities, which requires the understanding of complex processes that occur in plasmas of nuclear materials. The area of nuclear safety has seen a resurgence of public interest, and there is a concomitant need to safely store used nuclear fuel and detect structural material failure in nuclear power systems, especially in innovative reactor designs envisioned for future adoption. Laser-produced plasmas are complicated extreme environments that can generate intense and rich, highly specific signatures of nuclear and radiological materials, which can then be explored in a wide range of applications. They include interdiction and rapid detection of nuclear materials, including their isotopic composition, detection over long distances, laboratory simulation of weapons effects, monitoring the condition of structural materials in dry cask storage containers, and novel instrumentation for nuclear power systems. We present a compilation of recent representative examples of the application of laser spectroscopy, and laser-induced breakdown spectroscopy in particular, to nuclear safety and security problems. A case is made that spectroscopic techniques based on laser-produced plasmas offer complementary, and sometimes unique, capabilities that motivate the continued exploration of their efficient production and understanding of the signatures they produce

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

Sequential and Simultaneous 4-Antenna Microwave Ablation in an Ex Vivo Bovine Liver Model

Aims: To determine the sizes and shapes of ablation zones in 4-antenna microwave ablation in ex vivo bovine liver model under different conditions of power delivery patterns, antenna spacings, and ablation durations, for further using of multi-antenna MWA strategies in the treatment of large hepatocellular carcinoma. Methods: We tested protocols of eight ablations each on ex vivo bovine livers, involving simultaneous or sequential activation of four microwave antennas, spaced either 3 cm, 4 cm, or 5 cm apart, for either 10 or 15 min, at 60-W power. We determined the diameters, shapes, and temperatures of the ablation zones. Results: Compared to sequential power delivery, simultaneous power delivery resulted in significantly larger ablation zone diameters (P < .001). The temperatures in ablation zones were significantly higher for simultaneous than for sequential power delivery. The largest ablation diameter (7.45 ± 0.06 cm) resulted from simultaneous delivery for 15 min using 4-cm antenna spacing. Conclusions: Simultaneous 4-antenna microwave ablation results in larger ablation zones than sequential ablation, and 4-cm antenna spacing with a 15-minute ablation duration creates the largest ablation zone. This information may provide multi-antenna MWA strategies for large HCC in the further clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving indirect-drive ablator performance through pulse shaping and material selection in double shell implosions

The double shell path to inertially confined volumetric thermonuclear burn relies on efficient kinetic energy transfer from an outer ablator shell to an inner shell containing DT fuel at implosion velocities near 250 km/s. In order to experimentally realize adequate compression, target imperfections and assembly features must be tightly controlled. Pulse shape and ablator material are critical design choices that impact all aspects of the implosion. In this article, we evaluate three designs: an Al ablator with single-shock radiation drive, a CH ablator with single-shock drive, and a CH ablator with reduced-adiabat 2-shock drive. All designs use the same W inner (pusher) shell overcoated with a glow discharge polymer tamper and filled with liquid-density DT. One-dimensional HYDRA simulations revealed that the plastic ablator design required the use of the 2-shock drive to match the performance of the Al design. Two-dimensional simulations resolving broadband surface roughness up to modes of several hundred placed only on the ablator showed plastic to greatly outperform Al. The plastic ablator designs did exhibit higher levels of inner shell instability growth when surface roughness was only placed at the pusher/tamper interface, which was mitigated with higher foam cushion densities. A unique and additional benefit of a plastic ablator is also discussed, where heating of the ablator by Au M-band radiation is predicted to rapidly expand the hemi-shell surfaces, closing the equatorial joint gap ahead of the first shock. Taken together, the properties of the plastic ablator for indirect-drive double shell implosions appear promising in removing several long-standing fabrication challenges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Local Thermal Ablation with Continuous EGFR Tyrosine Kinase Inhibitors for EGFR-Mutant Non-small Cell Lung Cancers that Developed Extra-Central Nervous System (CNS) Oligoprogressive Disease

Background: Most epidermal growth factor receptor (EGFR)-mutant non-small cell lung cancer (NSCLC) patients treated with tyrosine kinase inhibitors (TKIs) experience oligoprogressive disease. Local ablation for isolated resistant sites continued with the original EGFR-TKI showed good efficacy in these patients. We conducted this multicenter retrospective study to investigate the potential benefit of thermal ablation in NSCLC patients that developed extra-central nervous system (CNS) oligoprogressive disease during TKI treatment. Methods: A total of 71 EGFR-mutant patients treated with EGFR-TKIs were identified. Progression-free survival 1 (PFS1) was calculated from the initiation of TKI treatment to first progression. Patients with metastatic sites ≤ 3 in less than 3 extra-CNS organs suitable for local ablation therapy received either radiofrequency ablation or microwave ablation to these sites and continued on the original TKIs. PFS2 was defined from the first progression to second progression after ablation. Results: The median PFS1 for all patients was 11.8 months. Eighty extra-CNS oligoprogressive lesions in 71 patients were ablated. Thirty-six of 71 patients progressed after thermal ablation and 31 of whom died during the study period. The median PFS2 after thermal ablation was 10.0 months, and the median overall survival was 26.4 months. PFS1 and PFS2 were highly correlated with OS, whereas PFS1 was not correlated with PFS2. The numbers of oligoprogressive lesions were significantly and independently associated with PFS2. Conclusion: Local thermal ablation for the oligoprogressive lesions with continuous EGFR-TKI treatment is associated with additional 10 months of disease control and should be recommended in TKI acquired resistant-NSCLC patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Carbon ablator areal density at fusion burn: Observations and trends at the National Ignition Facility

For inertial confinement fusion experiments, the pusher is composed of a high-density deuterium tritium cyrogenic fuel layer and an ablator, often made of carbon. In an ideal, no-mix implosion, increasing the areal density of the pusher transfers more pressure to the hot spot and increases the hot spot confinement time. There has been a lack of knowledge about the final compressed state of the ablator for implosions at the National Ignition Facility. 14 MeV fusion neutrons inelastically scattering on the remaining carbon ablator excites a nuclear metastable state that emits a prompt 4.4 MeV gamma ray. The gamma reaction history diagnostic data, when reduced by a new data analysis technique, can isolate and measure the carbon gamma rays, which are proportional to the areal density of the ablator during fusion burn. The trends over many National Ignition Facility campaigns show that the ablator areal density is weakly sensitive to the maximum shell velocity, the cold fuel radius, the ablator mass remaining, or the laser picket intensity. Controlled parameter scans reveal that, for specific campaigns, ablator compression has a strong dependence on laser coast time, high Z dopants, and the laser drive foot duration. Using a model of the compressed ablator density profile reveals that the greatest variation of the ablator areal density comes from its thickness, with highly compressed, thin layers having high areal density values. The compression and thickness of the ablator are other metrics that designers should understand to differentiate the types of capsule degradation and maximize the inertial confinement fusion performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Depth-Resolved Lithiated Gradients in Pristine and Laser-Ablated Anodes During Fast Charging

Laser ablating 3D electrode microstructures is a technique to improve Li-ion battery fast-charge performance. This technique has been theoretically proposed and electrochemically validated previously in the literature. The fundamental principle underlying laser ablation is that the ablated features reduce Li-ion transport pathways, improving access to the electrode active material near the current collector. This, in turn, promotes more homogeneous electrode utilization. The present study seeks to directly affirm the physics attributed to laser ablation using operando high-speed synchrotron X-ray diffraction. In this study, depth-resolved graphite lithiation gradients are measured operando during high-rate (15 min) charging. The depth-resolved lithiation dynamics of both ablated and non-ablated anodes are compared. The results highlight that the laser-ablated graphite electrode has notably more homogeneous utilization as compared to the non-ablated electrode. Additionally, the ablated electrode has a significant delay in reaching the maximum graphite lithiation at the separator, indicating less propensity for lithium plating. During low rate delithiation/discharge (2 hr), the two cells' lithiation gradients converge. Notably, a calibrated physics-based electrochemical model accurately reflects experimental findings, suggesting the potential to use pseudo-4D models not only to optimize laser ablation parameters in fast-charge capable electrodes but also to guide fast charging protocols that avoid lithium plating.

25 ENERGY STORAGE↗

Characterization of ultrafast-laser ablation of micro-structures in Li-ion battery anode and cathode materials: Morphology, rate, and efficiency

Characterization of the rate and quality of ultrafast-laser ablation of Li-ion battery (LIB) electrode materials is presented for a collection of common and next-generation electrodes. Laser ablated micro-structures on the surface of LIB electrodes have been shown to provide dramatic enhancement of high-rate capability and electrode wetting. However, industrial adoption is hampered by a lack of data enabling informed choice of laser parameters and predicting process throughput. Here this work bridges this gap by providing characterization of the ablation process at more laser parameters (laser fluence and number of pulses used) than are currently available in the literature. Further, we expand on previous graphite and lithium iron phosphate (LFP) ablation work by extending ablation characterization to new LIB materials, providing high data resolution and adopting new characterization metrics which are relevant for industrial application of this technology. Ablated pores are characterized by their ablated depth, volume, and how the depth and volume ablation rate changes as a function of pore depth. Finally, we provide a detailed characterization of the morphology of laser ablated micro-structures which informs how material and laser parameters affect the quality of laser-processed electrodes.

25 ENERGY STORAGE↗