Aberrant Assembly Complexes of the Reaction Center Light Harvesting 1 PufX (RC-LH1-Pufx) Core Complex of Rhodobacter sphaeroides Imaged by Atomic Force Microscopy
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Here, this article describes the establishment, over a period of 10 years or so, of a multi-user, institution-wide facility for the characterization of materials and devices at the nanoscale. Emphasis is placed on the type of equipment that we have found to be most useful for our users, and the business strategy that maintains its operations. A central component of our facility is an aberration-corrected environmental transmission electron microscope and its application is summarized in the studies of plasmon energies of silver nanoparticles, the band gap of PbS quantum dots, atomic site occupancy near grain boundaries in yttria stabilized zirconia, the lithiation of silicon nanoparticles, in situ observations on carbon nanotube oxidation and the electron tomography of varicella zoster virus nucleocapsids.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided.
Purpose: Transcranial magnetic resonance-guided focused ultrasound surgery is a noninvasive technique for causing selective tissue necrosis. Variations in density, thickness, and shape of the skull cause aberrations in the location and shape of the focal zone. In this paper, the authors propose a hybrid simulation-MR-ARFI technique to achieve aberration correction for transcranial MR-guided focused ultrasound surgery. The technique uses ultrasound beam propagation simulations with MR Acoustic Radiation Force Imaging (MR-ARFI) to correct skull-caused phase aberrations. Methods: Skull-based numerical aberrations were obtained from a MR-guided focused ultrasound patient treatment and were added to all elements of the InSightec conformal bone focused ultrasound surgery transducer during transmission. In the first experiment, the 1024 aberrations derived from a human skull were condensed into 16 aberrations by averaging over the transducer area of 64 elements. In the second experiment, all 1024 aberrations were applied to the transducer. The aberrated MR-ARFI images were used in the hybrid simulation-MR-ARFI technique to find 16 estimated aberrations. These estimated aberrations were subtracted from the original aberrations to result in the corrected images. Each aberration experiment (16-aberration and 1024-aberration) was repeated three times. Results: The corrected MR-ARFI image was compared to the aberrated image and the ideal image (image with zero aberrations) for each experiment. The hybrid simulation-MR-ARFI technique resulted in an average increase in focal MR-ARFI phase of 44% for the 16-aberration case and 52% for the 1024-aberration case, and recovered 83% and 39% of the ideal MR-ARFI phase for the 16-aberrations and 1024-aberration case, respectively. Conclusions: Using one MR-ARFI image and noa priori information about the applied phase aberrations, the hybrid simulation-MR-ARFI technique improved the maximum MR-ARFI phase of the beam's focus.
Here, we derived first and second order analytic aberration formulas in the horizontal transverse plane for an electrostatic deflector specified by the reference orbit radius, the central angle spanning the deflector, and its inhomogeneity coefficients. The derivation was performed using an iterative order-by-order perturbation method in a Frenet–Serret beamline coordinate system. We produced a C program edabrt for calculation of the first and second order aberrations using the formulas that we derived. The electrostatic deflector aberration formulas from Wollnik (1965) disagree with COSY INFINITY and the aberration formulas that we derived here, and they also deviate from the first and second order symplecticity conditions. The reason for this discrepancy is that the aberration formulas from Wollnik (1965) consider only motion in the main field of the deflector and do not properly account for fringe field effects, in particular the necessarily occurring change of kinetic energy due to the change in potential. The code GIOS uses electrostatic aberration formulas from Wollnik (1965) and exhibits the same discrepancy. We performed a comparison of first and second order electrostatic deflector aberrations for (1) the analytic formulas derived in this work, (2) differential-algebraic (DA) numerical integration of the equations of motion using the code COSY INFINITY, (3) the aberration formulas from Wollnik (1965), (4) aberrations computed using the code GIOS, and (5) the aberration formulas from Wollnik (1965) adjusted to account for the occurring change in potential. An electrostatic spherical deflector and an electrostatic cylindrical deflector were used as test cases for this comparison. There is excellent agreement between methods (1), (2), and (5), and these three methods satisfy the first and second order symplecticity conditions.
An aberration calculation method which was developed by Lu [1] can treat individual aberration term precisely. Spectral aberration is the linear sum of these aberration terms, and the aberrations of multi-element systems also can be calculated correctly when the stretching ratio, defined herein, is unity. Evaluation of focusing mirror-grating systems which are optimized according to Lu’s method, along with the Light Path Function (LPF) and the Spot Diagram method (SD) are discussed to confirm the advantage of Lu’s methodology. Lu’s aberration terms are derived from a precise wave-front treatment, whereas the terms of the power series expansion of the light path function do not yield an accurate sum of the aberrations. Moreover, Lu’s aberration terms can be individually optimized. This is not possible with the analytical spot diagram formulae.
Purpose: The measurement based on Shack-Hartmann wave-front sensor(WFS), obtaining both the high and low order wave-front aberrations simultaneously and accurately, has been applied in the detection of human eyes aberration in recent years. However, Its application is limited by the small field of view (FOV), slight eye movement leads the optical bacon image exceeds the lenslet array which result in uncertain detection error. To overcome difficulties of precise eye location, the capacity of detecting eye wave-front aberration over FOV much larger than simply a single conjugate Hartmann WFS accurately and simultaneously is demanded. Methods: Plenoptic camera’s lenslet array subdivides the aperture light-field in spatial frequency domain, capture the 4-D light-field information. Data recorded by plenoptic cameras can be used to extract the wave-front phases associated to the eyes aberration. The corresponding theoretical model and simulation system is built up in this article to discuss wave-front measurement performance when utilizing plenoptic camera as wave-front sensor. Results: The simulation results indicate that the plenoptic wave-front method can obtain both the high and low order eyes wave-front aberration with the same accuracy as conventional system in single visual angle detectionand over FOV much larger than simply a single conjugate Hartmann systems. Meanwhile, simulation results show that detection of eye aberrations wave-front in different visual angle can be achieved effectively and simultaneously by plenoptic method, by both point and extended optical beacon from the eye. Conclusion: Plenoptic wave-front method possesses the feasibility in eye aberrations wave-front detection. With larger FOV, the method can effectively reduce the detection error brought by imprecise eye location and simplify the eye aberrations wave-front detection system comparing with which based on Shack-Hartmann WFS. Unique advantage of the plenoptic method lies in obtaining wave-front in different visual angle simultaneously, which provides an approach in building up 3-D model of eye refractor tomographically. Funded by the key Laboratory of High Power Laser and Physics, CAS Research Project of National University of Defense Technology No. JC13-07-01; National Natural Science Foundation of China No. 61205144.
In the past 15 years, the advent of aberration correction technology in electron microscopy has enabled materials analysis on the atomic scale. This is made possible by precise arrangements of multipole electrodes and magnetic solenoids to compensate the aberrations inherent to any focusing element of an electron microscope. In this paper, we describe an alternative method to correct for the spherical aberration of the objective lens in scanning transmission electron microscopy (STEM) using a passive, nanofabricated diffractive optical element. This holographic device is installed in the probe forming aperture of a conventional electron microscope and can be designed to remove arbitrarily complex aberrations from the electron's wave front. In this work, we show a proof-of-principle experiment that demonstrates successful correction of the spherical aberration in STEM by means of such a grating corrector (GCOR). Our GCOR enables us to record aberration-corrected high-resolution high-angle annular dark field (HAADF-) STEM images, although yet without advancement in probe current and resolution. Finally, improvements in this technology could provide an economical solution for aberration-corrected high-resolution STEM in certain use scenarios.
Aberration correction is an important aspect of modern high-resolution scanning transmission electron microscopy. Most methods of aligning aberration correctors require specialized sample regions and are unsuitable for fine-tuning aberrations without interrupting on-going experiments. Here, we present an automated method of correcting first- and second-order aberrations called BEACON, which uses Bayesian optimization of the normalized image variance to efficiently determine the optimal corrector settings. We demonstrate its use on gold nanoparticles and a hafnium dioxide thin film showing its versatility in nano- and atomic-scale experiments. BEACON can correct all first- and second-order aberrations simultaneously to achieve an initial alignment and first- and second-order aberrations independently for fine alignment. Ptychographic reconstructions are used to demonstrate an improvement in probe shape and a reduction in the target aberration.
While medical ultrasound imaging has become one of the most widely used imaging modalities in clinics, it often suffers from suboptimal image quality especially in technically difficult patients with a large amount of fat content that induces severe phase aberration effects and decreases the signal-to-noise (SNR) ratio. Several researchers have proposed various techniques, which can be broadly categorized as either a phase aberration correction (PAC) technique or a coherence-based imaging technique, to address the challenges in imaging technically difficult patients. Although both families of techniques have shown some success in improving the image quality in the presence of a mild level of phase aberration and/or random noise, they often fail to achieve meaningful improvements in the image quality and in some cases, and even create severe image artifacts. In this work, we employ an adaptive filtering technique called frequency-space (F-X) prediction filtering, which we recently introduced in ultrasound imaging, to overcome the weaknesses of existing techniques and achieve image quality improvements more effectively under varying levels of phase aberration and random noise. Using simulated and experimental phantom data with varying levels of phase aberration and random noise, we evaluate and compare the performance of FXPF with the most representative technique for each category: NNCC-based PAC and the generalized coherence factor (GCF). Our simulation, experimental phantom, and in vivo results demonstrate that FXPF is highly robust in varying levels of phase aberration and noise, and always outperforms both NNCC-based PAC and GCF in terms of the contrast-to-noise ratio (CNR) and the contrast when both random noise and phase aberration are present.
In this work we performed an analysis of the derivation of first and second order analytic aberration formulas by Wollnik (1965) for the case of electrostatic deflectors in the horizontal plane. We found that these aberration formulas are valid for the main field of the deflector; however, they do not account for any fringe field effects. To address this issue, we modified the aberration formulas from Wollnik (1965) for a hard edge fringe field by scaling the particle inclinations at the entrance and exit edges of the deflector. These modified aberration formulas fully agree with electrostatic aberration formulas derived by Valetov and Berz (2020), as well as with differential-algebraic (DA) calculations of electrostatic deflector aberrations using the code COSY INFINITY.
High-resolution tissue imaging is often compromised by sample-induced optical aberrations that degrade resolution and contrast. Although wavefront sensor-based adaptive optics (AO) can measure these aberrations, such hardware solutions are typically complex, expensive to implement and slow when serially mapping spatially varying aberrations across large fields of view. Here we introduce AOViFT (adaptive optical vision Fourier transformer)—a machine learning-based aberration sensing framework built around a three-dimensional multistage vision transformer that operates on Fourier domain embeddings. AOViFT infers aberrations and restores diffraction-limited performance in puncta-labeled specimens with substantially reduced computational cost, training time and memory footprint compared to conventional architectures or real-space networks. We validated AOViFT on live gene-edited zebrafish embryos, demonstrating its ability to correct spatially varying aberrations using either a deformable mirror or postacquisition deconvolution. By eliminating the need for the guide star and wavefront sensing hardware and simplifying the experimental workflow, AOViFT lowers technical barriers for high-resolution volumetric microscopy across diverse biological samples.
Wavefront errors of rotationally parabolic refractive X-ray lenses made of beryllium (Be CRLs) have been recovered for various lens sets and X-ray beam configurations. Due to manufacturing via an embossing process, aberrations of individual lenses within the investigated ensemble are very similar. By deriving a mean single-lens deformation for the ensemble, aberrations of any arbitrary lens stack can be predicted from the ensemble with σ¯ = 0.034λ. Using these findings the expected focusing performance of current Be CRLs are modeled for relevant X-ray energies and bandwidths and it is shown that a correction of aberrations can be realised without prior lens characterization but simply based on the derived lens deformation. As a result, the performance of aberration-corrected Be CRLs is discussed and the applicability of aberration-correction demonstrated over wide X-ray energy ranges.
Here, an analysis is performed of how uncorrected antisymmetric aberrations, such as coma and trefoil, affect cryo-EM single-particle reconstruction (SPR) results, and an analytical formula quantifying information loss owing to their presence is inferred that explains why Fourier-shell coefficient-based statistics may report significantly overestimated resolution if these aberrations are not fully corrected. The analysis is validated with reference-based aberration refinement for two cryo-EM SPR data sets acquired with a 200 kV microscope in the presence of coma exceeding 40 µm, and 2.3 and 2.7 Å reconstructions for 144 and 173 kDa particles, respectively, were obtained. The results provide a description of an efficient approach for assessing information loss in cryo-EM SPR data acquired in the presence of higher order aberrations, and address inconsistent guidelines regarding the level of aberrations that is acceptable in cryo-EM SPR experiments.
Aberration correction by an electron mirror dramatically improves the spatial resolution and transmission of photoemission electron microscopes. We will review the performance of the recently installed aberration corrector of the X-ray Photoemission Electron Microscope PEEM-3 and show a large improvement in the efficiency of the electron optics. Hartmann testing is introduced as a quantitative method to measure the geometrical aberrations of a cathode lens electron microscope. Here, we find that aberration correction leads to an order of magnitude reduction of the spherical aberrations, suggesting that a spatial resolution of below 100 nm is possible at 100% transmission of the optics when using x-rays. We demonstrate this improved performance by imaging test patterns employing element and magnetic contrast.
Multipole aberration correctors have given scanning transmission electron microscopes (STEM) the ability to produce high-quality, atomic-resolution images, enabling STEM to be a key tool in material sciences for characterizing the structure and composition of materials. However, the process of correcting these aberrations typically requires human input and is accomplished using scanned STEM or Ronchigram images at different focii and beam tilts. In this work, we demonstrate an automated on-sample aberration correction system using Bayesian Optimization. We have developed a Python-based server able to communicate with the CEOS DCOR aberration corrector and the Thermo Fischer microscope scripting interface. This server allows us to change aberrations, acquire images and perform basic image analysis.