Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “7A Type A”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development and Application of an Oversize Reusable DOT 7A Type A Overpack Container at the Y-12 National Security Complex - 13150

Waste Management personnel at the Y-12 National Security Complex (Y-12) are concluding a multi-year effort to dispose of a large backlog of low-level waste. Six containers presented a particularly difficult technical challenge in that they each contained large robust equipment (mostly salt baths) with elevated levels of highly enriched uranium (exceeding U.S. Department of Transportation (DOT) fissile-excepted quantities). The equipment was larger than the standard 1.2 m x 1.2 m x 1.8 m (4 ft x 4 ft x 6 ft) DOT Specification 7A Type A box and would have been very difficult to size-reduce because of several inches of steel plate (along with insulating block and concrete) in the equipment design. A critical breakthrough for the success of the project involved procuring and developing two oversize reusable DOT Specification 7A Type A (fissile tested) containers (referred to as the CTI Model 7AF-690-SC) that could be used as overpacks for the original boxes of equipment. The 7A Type A overpack containers are approximately 3.5 m long x 2.7 m wide x 2.8 m high (11.7 ft x 8.9 ft x 9.2 ft) with a maximum gross weight of 10,660 kg (23,500 lb) and a payload capacity of 6,804 kg (15,000 lbs). The boxes were designed and fabricated using a split cavity design that allowed the gasketed and bolted closure to lie along the horizontal centerline of the box. The central closure location in this design allows for strengthening of box corners that tend to be points of weakness or failure in 49CFR173.465 drop tests. By combining the split cavity design with large diameter tubing and diagonal cross bracing, drop test requirements of 49CFR173.465(1) and (2) were met and demonstrated through finite element analysis modeling. The development and use of this new container dramatically reduced the need for down-sizing the equipment and allowed the project to meet objectives within cost and schedule targets. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recommendations for DOT 7A Type A Drum Closure and Drop Testing with Additional 49 CFR 173.465(c)(2) Testing and Analysis

The Savannah River National Laboratory (SRNL) is in the process of developing recommendation for the U S. Department of Energy contractors and vendors who want to qualify drums as U S. Department of Transportation (DOT) 7A Type A to meet 49 CFR 173.465 drop testing requirements for fissile and non-ftssile material to maintain containment. Based on the finite element analysis (FEA) models, the safety features suffering the maximum damage that result in loss of containment are identified as the closure ring mechanism (in entirety), the top (mouth area) of the drum, and the lid (including the gasket). The maximum damage is measured in terms of the collective ability of these combined three safety features to maintain containment. As such, both drop testing and FEA were performed to determine the sensitivities of these safety features to drop variations. As part of this effort, a series of physical drop tests and FEAs were conducted at SRNL. These tests used Skolnik drums, CQ5508L (see Attachment 1), which are open DOT 7A Type A open- head carbon steel 208-liter (55-gallon) drums with 12-gauge bolted closure rings. Variables studied were (1) stress relief methods during closure ring installation, (2) content configurations, and (3) drum orientations during a 4-foot free fall. It should be noted that the Skolnik CQ5508L drums have a closure ring with a "V shaped" cross section. (1) The closure testing with analysis confirmed that closure stress relief by rapping is necessary to distribute the closure ring tension around the perimeter and to maintain sufficient closure pre-load for lid retention during 4-foot drops of the heavier packages (500 to 1,000 lbs). It was concluded that no specific style of stress relief is preferred (e g., multi-step rapping/torqueing process, heavy hits vs. light hits, hitting near closure vs. away), as long as no additional change in bolt torque occurs with additional rapping. (2) (3) Modeling indicated that maximum damage is a result of both: (2) content configuration and (3) drop orientation. The worst-case content configuration is one with an eccentrically loaded concentrated content mass. FEA modeling showed that the center- of-gravity over top (CGoT) with the eccentric content on the high side was the orientation of maximum damage relative to drum lid retention. In this content configuration (i.e., CGoT), FEA modeling showed payloads over 500 lbs were required to contain a load distribution plate between content and lid. Both analysis and testing showed the drum with distribution plate can pass the 4-foot CGoT drop.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cask RT-100 Type B(U) Self-Certification for DOT 7A, Type A Nuclear Waste Transportation - 20098

The purpose of this Type A certification is to diversify the use of the RT-100 cask by allowing the end user to transport either Type A or Type B radioactive waste in accordance with the handling procedures for each waste category. The project's scope included the development of a matrix that contains all applicable requirements for a Type A package from the Code of Federal Regulations (CFR), Title 49 for the Department of Transportation (DOT) with a justification for each requirement. Moreover, the scope included the writing of conditions and restrictions list for the transportation of Type A nuclear waste, the writing of a compliance statement, and the design and fabrication of a Type A placard to be permanently placed on the RT-100 cask. Type A packages are self-certified by the end user using one of three methods as permitted by 49 CFR 173.461, either by performance of tests with prototypes or samples of the specimens representing the packaging, or reference to a previous satisfactory demonstration of compliance of a sufficiently similar nature, or calculations or reasoned evaluation using reliable and conservative procedures and parameters. Since the RT-100 cask was licensed by the Nuclear Regulatory Commission (NRC) as a Type B cask, Robatel relied on the method of reference to a previous satisfactory demonstration of compliance of a sufficiently similar nature for Type A certification. This method was determined to be acceptable, since Type B packages are evaluated for more demanding transport conditions than those required for Type A packages. This paper presents Robatel's process for certifying the RT-100 cask for Type A shipments, an overview of the DOT regulations related to Type A packages, and the documents that were generated for the end user. This paper is concluded with a discussion on the advantages of having the option to transport both Type A and Type B nuclear waste, and possible future projects to further improve the operation of the cask when making Type A shipments. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Test report dot 7A type a liquid packaging

This test report documents the performance of Savannah River National Laboratory’s (SRNL’s) U.S. Department of Transportation (DOT) Specification 7A; General Packaging, Type A shielded liquid shipping packaging and compliance with the regulatory requirements of Title 49 of the Code of Federal Regulations (CFR). The primary use of this packaging design is for the transport of radioactive liquids of up to 1.3 liters in an unshielded configuration and up to 113 mL of radioactive liquids in a shielded configuration, with no more than an A2 quantity in either configuration, over public highways and/or commercial aircraft. The contents are liquid radioactive materials sufficiently shielded and within the activity limits specified in173.435 or 173.433 for A2 (normal form) materials, as well as within the analyzed thermal heat limits. Any contents must be compatibly packaged and must be compatible with the packaging. The basic packaging design is based on the U.S. Department of Energy’s (DOE’s) Model 9979 Type A fissile shipping packaging designed and tested by SRNL. The shielded liquid configuration consists of the outer and inner drums of the 9979 package with additional low density polyethylene (LDPE) dunnage nesting a tungsten shielded cask assembly (WSCA) within the 30-gallon inner drum. The packaging model for the DOT Specification 7A, Type A liquids packaging is HVYTAL.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of Different Standard Type A7A Drum Closure-Ring Practices on Gasket Contraction and Bolt Closure Distance– 15621

The Department of Energy, the Savannah River National Laboratory, several manufacturers of specification drums, and the United States Department of Transportation (DOT) are collaborating in the development of a guidance document for DOE contractors and vendors who wish to qualify containers to DOT 7A Type A requirements. Currently, the effort is focused on DOT 7A Type A 208-liter (55-gallons) drums with a standard 12-gauge bolted closure ring. The U.S. requirements, contained in Title 49, Part 178.350 “Specification 7A; general packaging, Type A specifies a competent authority review of the packaging is not required for the transport of (Class 7) radioactive material containing less than Type A quantities of radioactive material. For Type AF drums, a 4 ft. regulatory free drop must be performed, such that the drum “suffers maximum damage.” Although the actual orientation is not defined by the specification, recent studies suggest that maximum damage would result from a shallow angle top impact, where kinetic energy is transferred to the lid, ultimately causing heavy damage to the lid, or even worse, causing the lid to come off. Since each vendor develops closure recommendations/procedures for the drums they manufacture, key parameters applied to drums during closing vary based on vendor. As part of the initial phase of the collaboration, the impact of the closure variants on the ability of the drum to suffer maximum damage is investigated. Specifically, closure testing is performed varying: 1) the amount of torque applied to the closure ring bolt; and, 2) stress relief protocol, including: a) weight of hammer; and, b) orientation that the hammer hits the closure ring. After closure, the amount of drum lid gasket contraction and the distance that the closure bolt moves through the closure ring is measured.

42 ENGINEERING↗

Impact of different standard type A7A drum closure-ring practices on gasket contraction and bolt closure distance - 15621

The Department of Energy, the Savannah River National Laboratory, several manufacturers of specification drums, and the United States Department of Transportation (DOT) are collaborating in the development of a guidance document for DOE contractors and vendors who wish to qualify containers to DOT 7A Type A requirements. Currently, the effort is focused on DOT 7A Type A 208-liter (55-gallons) drums with a standard 12-gauge bolted closure ring. The U.S. requirements, contained in Title 49, Part 178.350 'Specification 7A; general packaging, Type A specifies a competent authority review of the packaging is not required for the transport of (Class 7) radioactive material containing less than Type A quantities of radioactive material. For Type AF drums, a 4 ft. regulatory free drop must be performed, such that the drum 'suffers maximum damage.' Although the actual orientation is not defined by the specification, recent studies suggest that maximum damage would result from a shallow angle top impact, where kinetic energy is transferred to the lid, ultimately causing heavy damage to the lid, or even worse, causing the lid to come off. Since each vendor develops closure recommendations/procedures for the drums they manufacture, key parameters applied to drums during closing vary based on vendor. As part of the initial phase of the collaboration, the impact of the closure variants on the ability of the drum to suffer maximum damage is investigated. Specifically, closure testing is performed varying: 1) the amount of torque applied to the closure ring bolt; and, 2) stress relief protocol, including: a) weight of hammer; and, b) orientation that the hammer hits the closure ring. After closure, the amount of drum lid gasket contraction and the distance that the closure bolt moves through the closure ring is measured. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Test report dot7A type A liquid packaging

This section presents a general description of the DOT Specification 7A Type A liquid content packaging (HVYTAL), the liquid content evaluated as its payload, acceptable payload shipping configurations and features special to its use. This test report documents compliance with the regulatory safety requirements of 49 CFR Parts 173.24, 173.24a, 173.27, 173.410, 173.412, 173.461 – 173.466 and 178.350.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Savannah River Site Eastern Transportation Hub: A Concept For a DOE Eastern Packaging, Staging and Maintenance Center - 13143

The Department of Energy (DOE) is working to de-inventory sites and consolidate hazardous materials for processing and disposal. The DOE administers a wide range of certified shipping packages for the transport of hazardous materials to include Special Nuclear Material (SNM), radioactive materials, sealed sources and radioactive wastes. A critical element to successful and safe transportation of these materials is the availability of certified shipping packages. There are over seven thousand certified packagings (i.e., Type B/Type AF) utilized within the DOE for current missions. The synergistic effects of consolidated maintenance, refurbishment, testing, certification, and costing of these services would allow for efficient management of the packagings inventory and to support anticipated future in-commerce shipping needs. The Savannah River Site (SRS) receives and ships radioactive materials (including SNM) and waste on a regular basis for critical missions such as consolidated storage, stabilization, purification, or disposition using H-Canyon and HB-Line. The Savannah River National Laboratory (SRNL) has the technical capability and equipment for all aspects of packaging management. SRS has the only active material processing facility in the DOE complex and is one of the sites of choice for nuclear material consolidation. SRS is a logical location to perform maintenance and periodic testing of the DOE fleet of certified packagings. This initiative envisions a DOE Eastern Packaging Staging and Maintenance Center (PSMC) at the SRS and a western hub at the Nevada National Security Site (NNSS), an active DOE Regional Disposal Site. The PSMC's would be the first place DOE would go to meet their radioactive packaging needs and the primary locations projects would go to disposition excess packaging for beneficial reuse. These two hubs would provide the centralized management of a packaging fleet rather than the current approach to design, procure, maintain and dispose of packagings on a project-by-project basis. This initiative provides significant savings in packaging costs and acceleration of project schedules. In addition to certified packaging, the PSMC would be well suited for select designs of 7A Type A packaging and Industrial Packaging. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of the Performance of the SAVY Container Subjected to Various Impact Events using Finite Element Methods

The SAVY container is a Safety Class Design Feature utilized both inside engineered features and outside engineered features (e.g. gloveboxes) at TA-55 Plutonium Facility Building 4. These containers were certified as low damage ratio containers by demonstrating their ability to retain material after exposure to impacts and elevated temperatures resulting from a design basis seismic event. Original testing of the SAVY did not evaluate the effects of various facility specific insults to the SAVY while within a DOT Type A Container, caused either by design basis accident or an operational mishap. These insults include: 1. Impact of a structural I-beam (drum upright & drum on side); 2. Impact of a section of Positive Pressure Chilled Water Pipe (PPCWS); 3. Forklift fork tine impact; 4. Fuel truck impact. Abaqus Explicit Dynamics Finite Element Analysis was performed on a nested SAVY/DOT Type 7A container configuration to assess the structural integrity of the SAVY under the accident conditions listed.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Lightning Burnthrough to Containment Breach of 55-Gallon TRU Waste Drums

We investigated by arc-plasma heating the feasibility of attributing inherent lightning protection to 55-gallon DOT 7A, Type A, open head carbon steel drums made of 1.5 millimeter painted carbon steel, designed to protect Department of Energy transuranic nuclear waste. The Sandia Lightning Simulator transferred continuing current in 300 ampere (A), 400 A, and 500 A tests to achieve a 350 coulomb charge transfer and simulate cloud-to-ground lightning attachment to test coupons and 9 drums. A tungsten electrode was placed 0.75 inch from the drums. High-speed photography was recorded to observe the exterior containment breach, or "first light," seen on camera when burnthrough opened a hole in the containment. Sheet metal burnthrough occurred between 18 and 71 coulombs in lid and rolling hoop tests, but 12-gauge closure ring tests did not result in burnthrough, which suggests this feature may provide an inherent air terminal protective feature.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WIPP Space Faces TRU Waste Disposal Limits; The Volume Reducing Solution - 18365

Transuranic (TRU) waste packaging for removal from a glovebox has for many years involved the use of bags as the primary containment. In many cases, many hydrogenous layers of bags, yards of tape, and multiple filters are added to the waste stream in order to get the TRU waste into the final 55 gallon drum package to be shipped and buried at the Waste Isolation Pilot Plant (WIPP). The WIPP is currently limited to a total finite disposed volume of Contact Handled (CH) and Remote Handled (RH) TRU waste. As of early 2014 over half of the allotted WIPP volume had been filled with mainly CH-TRU waste. Based on current bag operation packaging methods used, the Department of Energy's (DOE) remaining CH and RH waste will not fit in the remaining limited WIPP space. Bag operations, can be performed safely by good operators following tedious repetitive processes and many Administrative Safety Controls. Since the bag is the only confinement layer between the contamination and the operator, contamination incidents can occur. Bag-out operations require close proximity to the waste to perform the process. With some waste streams, this close to waste proximity increases operator radiation dose. Central Research Laboratories (CRL), based in Red Wing Minnesota, who for many decades has developed proven engineered material transfer solutions based around their Rapid Transfer Port (RTP) technology, has worked with DOE sites to develop a TRU Waste Management Solution. The solution is a single filtered large Polyethylene (PE) or Stainless Steel (SST) Rapid Transfer Port container in a standard Department of Transportation (DOT) 7A, Type A drum, which allows for loading of TRU waste directly from the operational glovebox without the use of bags, sleeves or tapes to provide leak tight containment. All operator interventions to connect and disconnect a drum to and from the glovebox are achieved in an upright ergonomic position by one (1) operator in less than three (3) minutes. Minimal As Low As Reasonably Achievable (ALARA) levels are achieved during connect and disconnect of the drum, due to the engineered safety controls of the RTP. The CRL RTP solution allows glovebox or re-packaged TRU waste to be safely transferred to the final 55 Gallon drum container without additional bags or tape. The high diffusion coefficient filter on the CRL RTP 55G container and elimination of added hydrogenous packaging, improves the Decay Heat Limit (DHL) per drum for most TRU waste types compared with bagged drums, and in most cases allows more TRU waste to be loaded per drum. Inorganic TRU waste materials can be packaged directly into the CRL RTP SST drum container to the maximum DHL and Fissile Gram Equivalent (FGE) allowable for a drum. This paper will show how highly efficient TRAMPAC approved TRU waste packaging of CH and RH TRU waste can be accomplished in a safer, cost effective manner without adding any additional packaging materials to the waste stream, thus increasing the chance of placing all DOE's legacy and to be generated TRU waste in the remaining WIPP space. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Developments that are making the Versa-Pac Indeed More Versatile (and More Useful to Industry) - 16267

Daher-TLI acquired the assets and employees of Century Industries, a radioactive material packaging manufacturing facility, in 2013. Included in that acquisition was the Versa-Pac Shipping Package. The Versa-Pac is an NRC licensed Type AF packaging (Certificate of Compliance no. USA/9342/AF-96) and was originally designed as a replacement for standard 7A drum-type transportation packaging. It can be used directly or in conjunction with pails, drums or inserts that can be manufactured to accommodate a variety of smaller containers and vessels. The Versa-Pac comes in two sizes, the VP-55 (i.e., 55-gallon drum version) and VP-110 (i.e., 110-gallon drum version). It features a patented design concept in combination with the drum exterior to provide enhanced structural protection to payloads under Normal Conditions of Transport (NCT) and Hypothetical Accident Conditions (HAC), per 10CFR71.71 and 10CFR71.73 respectively. Since its introduction in 2010, the Versa-Pac has been utilized mainly as a one-time use package for disposing of radioactive waste. The package is also designed as a reusable package for transporting front-end materials. Discussions with current and prospective clients have resulted in numerous improvements, accomplished and planned, to the package's payload capability through additional engineering analyses and actual design modifications. Revision 10 to the NRC Certificate of Compliance, dated August 6, 2015, introduces an enrichment-loading table that allows shipping larger quantities of U-235 for enrichments less than 100 wt.%. It also authorizes shipment of natural thorium. Other planned and proposed improvements include provisions to transport UF{sub 6} in 1S, 2S, and 5B cylinders, design changes that further increases the amount of U-235 at enrichments less than 100 wt.%, increasing the capacity of the VP-110, developing a lighter 30-gallon version, the VP-30, and introducing content limits specific to uranium-oxides in multiple forms. This paper traces the engineering and design efforts involved in expanding the Versa-Pac's versatility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulation evaluation of transition and hover flying qualities of the E-7A STOVL aircraft

The generalized simulation model developed for the E-7A STOVL fighter-type aircraft configuration has attempted to define the limits of acceptibility for a vertical-to-horizontal-to-vertical flight transition envelope. An effort was also made to determine the control power required during hover and transition, and to evaluate whether the integration of flight and propulsion controls thus far effected achieves good flying qualities throughout the low-speed flight envelope. The results thus obtained furnish a general view of the acceptable transition corridor, expressed in terms of the minimum-climb capability.

Franklin, James A.↗

Lin28-let7 Modulates Radiosensitivity of Human Cancer Cells With Activation of K-Ras

Purpose: To evaluate the potential of targeting Lin28-let7 microRNA regulatory network for overcoming the radioresistance of cancer cells having activated K-Ras signaling. Methods and Materials: A549 lung carcinoma cells and ASPC1 pancreatic cancer cells possessing K-RAS mutation were transfected with pre-let7a microRNA or Lin28 siRNA, respectively. Clonogenic assay, quantitative reverse transcription polymerase chain reaction, and Western analysis were performed. The effects of Lin28 on SQ20B cells having wild-type K-RAS, and a normal fibroblast were also assessed. Results: The overexpression of let-7a decreased expression of K-Ras and radiosensitized A549 cells. Inhibition of Lin28, a repressor of let-7, attenuated K-Ras expression and radiosensitized A549 and ASPC1 cells. Neither SQ20B cells expressing wild-type K-RAS nor HDF, the normal human fibroblasts, were radiosensitized by this approach. Conclusions: The Lin28-let7 regulatory network may be a potentially useful therapeutic target for overcoming the radioresistance of human cancers having activated K-Ras signaling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated Cryocooler Monitor and Control System Software

This software is used in an automated cryogenic control system developed to monitor and control the operation of small-scale cryocoolers. The system was designed to automate the cryogenically cooled low-noise amplifier system described in "Automated Cryocooler Monitor and Control System" (NPO-47246), NASA Tech Briefs, Vol. 35, No. 5 (May 2011), page 7a. The software contains algorithms necessary to convert non-linear output voltages from the cryogenic diode-type thermometers and vacuum pressure and helium pressure sensors, to temperature and pressure units. The control function algorithms use the monitor data to control the cooler power, vacuum solenoid, vacuum pump, and electrical warm-up heaters. The control algorithms are based on a rule-based system that activates the required device based on the operating mode. The external interface is Web-based. It acts as a Web server, providing pages for monitor, control, and configuration. No client software from the external user is required.

Britchcliffe, Michael J.↗

UV testing of INTELSAT-7, 7A, and 8 solar cells

A 4000 hour experiment, conducted in late 1992 through mid 1993, confirmed earlier results on the ultraviolet damage effects in covered solar cells of various types being used, or proposed for use, in INTELSAT programs. Two different UV test systems were used to identify systematic errors and to study the effects of UV source-bulb age on degradation rate. After correction for contamination and UV source-bulb aging, the extrapolated degradation rates for irradiated and unirradiated INTELSAT-5, -6 single AR(SAR) coated cells and INTELSAT-7, -7A, -8 double layer AR(DAR) coated cells in both the 1993 tests confirm the following hypotheses resulting from the 1992 experiment. (a) Irradiated cells display significantly more UV degradation than do the unirradiated cells for tests exceeding 2000 hours. The new data indicates that degradation effects from electron irradiation are proportional to t(exp 2) (the square of the UV hours), at least for times less than or equal to 3000 hours. (b) This difference does not depend upon entire reflective coating, cell resistivity, or manufacturer within the sensitivity and reproducibility of the experiment. (c) There is a clear difference in degradation rate between single AR coated cells (TiO(x)) and double layer AR coated cells (SiO(x) and Al2O3?). At 100,000 hours (11.4 years) the DAR coated cells display more degradation than do the SAR coated cells, even though at 1,000 hours the DAR cells display less degradation. (d) UV degradation rates, to modern covered silicon solar cells, at the beginning of bulb life drop from approximately 2 times the average rate to near zero after 2000 hours (average end-of-life for the xenon short-arc lamps used in the tests). The effects of 1 MeV electron irradiation (10(exp 15) e(-)/sq cm) prior to UV exposure are clearly indicated in the plot of percent change in cell open circuit voltage (Voc) versus percent change in short circuit current (Isc) during the UV test and post-test cleanup of the cells. Clearly, extended UV testing produces a permanent photo-induced redegradation of previously irradiated cells. However, this photo-induced redegradation may be caused by the long-wavelength light, not the UV light.

Meulenberg, A.↗

Generalized enzymatic mechanism of catalysis by tetrameric L -asparaginases from mesophilic bacteria

The mechanism of catalysis by the L -glutaminase-asparaginase from Pseudomonas 7A (PGA) was investigated using structural, mass spectrometry, and kinetic data. We had previously proposed mechanism of hydrolysis of L -Asn by the type II L-asparaginase from E. coli (EcAII), but that work was limited to just one enzyme. Based on results presented in this report, we postulate that all homotetrameric L -asparaginases from mesophilic bacteria utilize a common ping-pong mechanism of catalysis consisting of two subsequent nucleophilic substitutions. Several new structures of non-covalent complexes of PGA with different substrates, as well as structures of covalent acyl-enzyme intermediates of PGA with canonical substrates ( L -Asp and L -Glu) and an opportunistic ligand, a citrate anion, were determined. The results of kinetic experiments monitored by high-resolution LC/MS, when combined with new structural data, clearly show that the reaction catalyzed by L -glutaminase-asparaginases proceeds through formation of a covalent intermediate, as observed previously for EcAII. Additionally, by showing that the same mechanism applies to L -Asn and L -Gln, we postulate that it is common for all these structurally related enzymes.

59 BASIC BIOLOGICAL SCIENCES↗