Engineering PapersSearch

SEARCH · Engineering Papers

Results for “6Li”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Calibration-free analysis of Li isotope ratios using laser ablation and laser absorption spectroscopy

We introduce a rapid, calibration-free, all-optical method for high-precision lithium isotope ratio measurements in solid materials using laser ablation combined with tunable laser absorption spectroscopy. A new asynchronous acquisition method is used to acquire time-resolved, high-resolution spectra of the 6Li and 7Li D1 and D2 transitions near 671 nm. Isotope ratios and atomic column densities are extracted from measured spectra via a physics-based fitting model including hyperfine structure. Under 1 Torr air, spectra recorded = 0.75 ms after plasma onset exhibit narrow linewidths corresponding to Doppler temperatures = 400 K, enabling resolution of the isotope peaks with high signal-to-noise ratios. Analysis of LiAlO2 samples with varying 6Li:7Li ratios demonstrates isotopic precisions of 0.6–1.7% for spectra acquired in 30 s. Isotope ratios determined from the spectral fits show accuracy within –0.3% to –1.7% of reference ICP-MS measurements without requiring calibration to external standards. By eliminating sample preparation and enabling spatially resolved isotopic mapping, this method offers a rapid analysis approach to lithium isotope determination in solid materials relevant to nuclear energy, safeguards, and geochemistry.

Phillips, Mark C.

ICP-MS For Analysis of Lithium Isotopic Ratios in Materials Highly Enriched in 7 Li (CRADA 626) Final Report

The intent of this project was to determine appropriate methodologies for analysis of lithium isotopes for 1) quasi-online monitoring of isotope separations, and 2) high-precision characterization of end-products, including lithium fluoride and lithium-beryllium fluoride (FLiBe). Traditionally, isotopic analysis requires the use of expensive, sophisticated instrumentation with often relatively long analytical timelines. We determined that the use of cheaper, smaller, and easier-to-operate instruments are sufficient for rapid analysis of lithium isotopes to monitor isotope separation efficiencies. In addition, we found that the analytical precision afforded by these lower-cost instruments is comparable to the more sophisticated (i.e., more expensive) instrumentation when the isotopic composition of lithium becomes highly depleted in 6Li. This finding will ultimately help lower costs of manufacturing of depleted lithium that is required for operation of certain designs of Generation IV nuclear reactors.

07 ISOTOPE AND RADIATION SOURCES

HIGHER EFFICIENCY FISSION COUNTER FOR NEUTRON DETECTION

Fission chambers containing 235U have been used for detection of neutrons for many decades. In these chambers 235U is electroplated on a metal which is one plate of an ionization chamber. Since the range of fission products from induced fission in the chamber is extremely short, these deposits from electroplating are so thin that the amount of 235U results in low neutron detection efficiency and the chamber needs high internal 235U surface area to increase efficiency. A typical ~8 in. long, ~2 in. diameter fission counter only contains < 2 g of 235U total, resulting in very low detection efficiency per incident neutron impinging on the outer surface of the detector. However, because of their large electronic pulses from fission products compared to gamma rays it is very easy to discriminate against gamma rays impinging on the detector. These types of chambers are produced commercially and are used worldwide in nuclear research and nuclear power reactors. ORNL has made a higher efficiency fission ionization chamber by using many thin concentric annuli to increase the area. A higher efficiency fission counter would be useful and can be made by incorporating 235U into a glass or ceramic scintillator. For nearly 100 years the green color in antique glass was produced by incorporation of depleted uranium (up to 20 wt. %) into a glass. The concept for this scintillation-optical-based fission detector is to dope a scintillator (either ceramic or glass) with 235U. Glass scintillators are commercially available doped with as much as 8 wt. % 6Li for neutron detection. In the 235U doped scintillator the fission product pulses would be double the size of those in an ion chamber since all fission products produce light in the scintillator whereas in the ionization chamber half do not go into the ionizing gas volume. These higher efficiency fission chambers would be very useful for a wide variety of research, nuclear research, and nuclear power reactor applications. Because of their smaller size and weight, they should be useful for space application such as monitoring of space nuclear power reactors. This report reviews existing fission chamber technology and suggests the development of these small high-efficiency fission chambers. Other fission isotopes could be used for other research applications.

Mihalczo, John [ORNL] (ORCID:0000000254292681)

Final Design for Thermal/Epithermal eXperiments (TEX) with Lithium Absorbers to Provide Validation Benchmarks for Y-12 Electrorefining Facility

One of the main goals of the Thermal/Epithermal eXperiments (TEX) project is to use existing Nuclear Criticality Safety Program (NCSP) assets to create critical experiment plutonium and uranium test beds for materials important to criticality safety that have insufficient benchmark evaluations. The plutonium test bed experiments were completed in 2018 and are published in the 2020 edition of the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The uranium test bed assemblies were completed in 2023 and accepted in the 2024 edition of the ICSBEP Handbook. The Nuclear Criticality Safety (NCS) group at Y-12 National Security Complex has identified programmatic need for validation cases for uranium electrorefining operations at Y-12. The electrorefining operation credits lithium enriched in 6 Li in addition to 35 Cl as absorbers in the design criticality safety evaluation for precluding criticality under upset conditions in the large and geometrically unfavorable electro-refiner. There is, however, inadequate experimental validation for the 6 Li absorbers. As an extension of the TEX uranium test bed, TEX-Cl critical experiments were performed with sodium chloride salt to address the 35 Cl thermal absorption as well as other validation needs at Los Alamos National Laboratory (LANL). These experiments were completed in 2024 and accepted into the 2025 ICSBEP Handbook. To continue the methodology used in TEX-Cl, TEX-Li aims to accomplish the same. The overall design of both experiments was to use commercially available, high purity, salts with polyethylene moderator and HEU plates to configure a critical assembly. Three experiments are planned for TEX-Li using encapsulated lithium carbonate (Li 2 CO 3 ), with natural 6 Li abundance. For all experiments, the highly enriched uranium (HEU) Jemima plates will be used as fissile material. Multiple layers will be stacked together with encapsulated Li 2 CO 3 alternated with polyethylene in standard configurations. Standard stacking was found to be optimal in matching the different sensitivity profiles provided by the Y-12 models. Three configurations are proposed with varying polyethylene moderation and a constant 1/4” absorber thickness. The first uses 11 layers of 5/4” polyethylene, the second uses 9 layers of 3/4” polyethylene, and the third uses 10 layers of 1/2” polyethylene. Calculations showed that some alternative forms of lithium-based materials provided slightly less-optimal sensitivity profiles when compared to lithium carbonate but come with other drawbacks. These alternatives included lithium aluminate (LiAlO 2 ), Aluminum-2050 alloy, Aluminum-8090, Aluminum-2095, lithium hydride (LiH), and lithium fluoride (LiF). Lithium aluminate and aluminum-2050 provided comparable sensitivity profiles when compared to lithium carbonate and can be used instead if lithium carbonate cannot be readily procured. After a broad material study, lithium carbonate outperformed any alternative material with a balance in affordability and workability. The assessment of experimental uncertainties of the non-absorber and absorber components was predicted to be 0.00089 and 0.00093 Δk eff , respectively. The largest uncertainties may be reduced with precision dimensional inspection of the components. Many of the parts and equipment for IER 575 have already been fabricated or procured for previous projects and therefore do not contribute significantly to the overall cost of this experiment. This includes the Jemima plates and Comet critical assembly machine, which are existing NCSP assets, as well as the aluminum platen and polyethylene reflector rings, which were fabricated and authorized for the TEX experiment involving HEU with polyethylene. Lithium carbonate containers will be procured by LANL and will be filled by LLNL. The total material costs for TEX-Li experiments are estimated to be on the order of $\$$47,400. Precision inspection, including dimensional, mass, density, and impurity, is recommended for all components for an estimated cost of $\$$12,000.

35Cl