Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “200 kW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Dynamic blade loading in the ERDA/NASA 100 kW and 200 kW wind turbines

Dynamic blade loads, including aerodynamic, gravitational, and inertial effects, are presented for two large horizontal-axis wind turbines: the ERDA-NASA 100 kW Mod-0 and 200 kw Mod-0A wind power systems. Calculated and measured loads are compared for an experimental Mod-0 machine in operation. Predicted blade loads are also given for the higher power Mod-0A wind turbine now being assembled for operation as part of a municipal power plant. Two major structural modifications have been made to the Mod-0 wind turbine for the purpose of reducing blade loads. A stairway within the truss tower was removed to reduce the impulsive aerodynamic loading caused by the tower wake on the downwind rotor blades. Also, the torsional stiffness of the yaw drive mechanism connecting the turbine nacelle to the tower was doubled to reduce rotor-tower interaction loads. Measured reductions in load obtained by means of these two modifications equaled or exceeded predictions.

Spera, D. A.↗

A 200-kW wind turbine generator conceptual design study

A conceptual design study was conducted to define a 200 kW wind turbine power system configuration for remote applications. The goal was to attain an energy cost of 1 to 2 cents per kilowatt-hour at a 14-mph site (mean average wind velocity at an altitude of 30 ft.) The costs of the Clayton, New Mexico, Mod-OA (200-kW) were used to identify the components, subsystems, and other factors that were high in cost and thus candidates for cost reduction. Efforts devoted to developing component and subsystem concepts and ideas resulted in a machine concept that is considerably simpler, lighter in weight, and lower in cost than the present Mod-OA wind turbines. In this report are described the various innovations that contributed to the lower cost and lighter weight design as well as the method used to calculate the cost of energy.

Source record↗

Utility operational experience on the NASA/DOE Mod-OA 200 kW Wind Turbine

The Mod-OA 200 kW Wind Turbine was designed and fabricated by the Lewis Research Center of the NASA under the direction of the U.S. Department of Energy. The project is a part of the Federal Wind Energy Program and is designed to obtain early wind turbine operation and performance data while gaining initial experience in the operation of large, horizontal axis wind turbines in typical utility environments. On March 6, 1978, the Mod-OA wind turbine was turned over to the Town of Clayton Light and Water Plant, Clayton, NM, for utility operation and on December 31, 1978 the machine had completed ten months of utility operation. This paper describes the machine and documents the recent operational experience at Clayton, NM.

Glasgow, J. C.↗

Simultaneous Convective and Radiative Heating of Materials with the 200 kW Laser Enhanced Arc Jet Facility (LEAF)

Recent installation of the 200-kW Laser Enhanced Arc Jet Facility (LEAF) at the Interaction Heating Facility (IHF) arc jet at NASA Ames Research Center has enabled combined heating of material samples. The LEAF system is permanently located adjacent to IHF. During LEAF operation, IHF can convectively heat material samples with heat fluxes up to 0.16 kW/cm 2 using the 22.86-cm nozzle or up to 0.07 kW/cm 2 using the truncated semi-elliptic nozzle. LEAF can deliver radiant heating with various profiles and sizes to a material sample. In flat-top square configuration, irradiance levels of nearly 0.1 kW/cm 2 have been demonstrated over a 43.2 x 43.2 cm area, and irradiance levels up to 0.39 kW/cm 2 have been demonstrated over a 15.2 x 15.2 cm area. LEAF can also be configured to deliver a super-Gaussian profile over a variety of beam diameters (1.8 to 5.6 cm). This configuration has been demonstrated up to peak irradiance levels of 25.7 kW/cm 2 per laser at the smallest, 1.8 cm, diameter setting. The LEAF system is composed of four 50-kW lasers, so it can also be configured to simultaneously deliver two different beam shapes (e.g., one square beam and one super-Gaussian beam).

Megan MacDonald↗

MOD-0A 200 kW wind turbine generator design and analysis report

The design, analysis, and initial performance of the MOD-OA 200 kW wind turbine generator at Clayton, NM is documented. The MOD-OA was designed and built to obtain operation and performance data and experience in utility environments. The project requirements, approach, system description, design requirements, design, analysis, system tests, installation, safety considerations, failure modes and effects analysis, data acquisition, and initial performance for the wind turbine are discussed. The design and analysis of the rotor, drive train, nacelle equipment, yaw drive mechanism and brake, tower, foundation, electricl system, and control systems are presented. The rotor includes the blades, hub, and pitch change mechanism. The drive train includes the low speed shaft, speed increaser, high speed shaft, and rotor brake. The electrical system includes the generator, switchgear, transformer, and utility connection. The control systems are the blade pitch, yaw, and generator control, and the safety system. Manual, automatic, and remote control are discussed. Systems analyses on dynamic loads and fatigue are presented.

Anderson, T. S.↗

Development of a 1 kW, 200 C Mapham Inventor

Electronic systems and components are often exposed to high temperature environment in space-based applications, nuclear power facilities, and geothermal energy extraction fields. A key requirement for these systems is, therefore, to withstand the high temperature exposure while maintaining efficient and reliable operation. Efforts were taken to design and develop a high temperature power inverter capable of 200 C operation. A 1 kW, 20 kHz Mapham inverter was designed and evaluated as a function of temperature at different load levels. The inverter system, excluding its input, control, and logic circuits, was characterized at temperatures from ambient to 200 C at 0%, 50%, and 100% resistive loading. With an applied input voltage of 75 VDC, the inverter produced an output of 250 VAC. The results obtained, which indicate good operational characteristics of the inverter up to 200 C, are presented and discussed.

Hammoud, Ahmad↗

Utility operational experience on the NASA/DOE MOD-0A 200-kW wind turbine

The Mod-0A 200 wind turbine was designed and fabricated as part of the Federal Wind Energy Program. Early wind turbine operation and performance data were obtained while gaining initial experience in the operation of large, horizontal axis wind turbines in typical utility environments. The Mod-0A wind turbine was turned over to the Town of Clayton Light and Water Plant, Clayton, NM, for utility operation and on December 31, 1978, the machine had completed ten months of utility operation. The machine is described and the recent operational experience at Clayton, NMis documented.

Glasgow, J. C.↗

An operating 200 kW horizontal axis wind turbine

Output from the 200-kilowatt machine will be enough to meet the power requirements of about 60 families. The experimental wind turbine generator (WTG) is a two-bladed, horizontal-axis, rotor system driving a synchronous electric generator through a step-up gear box located within a nacelle. The nacelle is mounted on top of a 100-foot tower with the rotor located downwind from the tower. The 200-kilowatt rated power output of the wind turbine is achieved at a turbine rotor speed of 40 rpm and a rated wind speed of 18.3 mph. The rated wind speed is defined as the lowest wind speed at which full power is achieved. Attention is given to operational details, aspects of blade design, blade fabrication, the use of strain gages, questions of aeroelastic stability, and an early analysis of test data.

Hunnicutt, C. L.↗

An operating 200-kW horizontal axis wind turbine

The Mod-OA wind turbine blades were rotated for the first time on November 30, 1977, establishing the Mod-OA as the first wind-driven generator in 35 years to be continually tied into an electrical power system which services a community. Tower-mounted equipment and blade structural design and fabrication are discussed.

Hunnicutt, C. L.↗

Development program for a 200 kW, technological processes in space

Dimensionless conservation equations, are presented and the theoretical basis of fluid behavior aboard orbiting satellites are reviewed with application to the processes of manufacturing crystals in weightlessness. The small amount of gravitational acceleration is shown to increase the separation of bands of varying concentration. Natural convection is shown to have no practical effect on crystallization from realistic conductions of weightlessness. The effects of surface tension become increasingly large, and suggestions are made for further research.

Jory, H.↗

Evaluation of an operating MOD-OA 200 kW wind turbine blade

Operating loads and structural damage were monitored during operation of the MOD-OA electric generating system. The turbine was damaged locally between stations 48 and 125 after 2.8 million rotations. Loads due to degraded yaw stiffness and fretting at rib station 48 were identified as primary to this distress. The repaired blades operated an additional 4.8 million rotations without problems.

Donham, R. E.↗

MOD-OA 200 kW wind turbine generator engineeringing

Engineering drawings and the detailed mechanical and electrical design of a horizontal-axis wind turbine designed for DOE at the NASA Lewis Research Center and installed in Clayton, New Mexico are discussed. The drawings show the hub, pitch change mechanism, drive train, nacelle equipment, yaw drive system, tower, foundation, electrical power systems, and the control and safety systems.

Andersen, T. S.↗

Operating experience with the 200 kW MOD-OA wind turbine generators

The machine configuration and its advantages and disadvantages, particularly as it affects reliability are discussed. The machine performance, both availability and power output characteristics are described. The Mod-OA operational experience is documented. The characteristics of the wind energy generated, the machine performance, and the subsystem strengths and weaknesses are discussed. An assessment of the project success in fulfilling its goals and objectives is also presented.

Birchenough, A. G.↗

Design and Development of a 200-kW Turbo-Electric Distributed Propulsion Testbed

The National Aeronautics and Space Administration (NASA) Armstrong Flight Research Center (AFRC) (Edwards, California) is developing a Hybrid-Electric Integrated Systems Testbed (HEIST) Testbed as part of the HEIST Project, to study power management and transition complexities, modular architectures, and flight control laws for turbo-electric distributed propulsion technologies using representative hardware and piloted simulations. Capabilities are being developed to assess the flight readiness of hybrid electric and distributed electric vehicle architectures. Additionally, NASA will leverage experience gained and assets developed from HEIST to assist in flight-test proposal development, flight-test vehicle design, and evaluation of hybrid electric and distributed electric concept vehicles for flight safety. The HEIST test equipment will include three trailers supporting a distributed electric propulsion wing, a battery system and turbogenerator, dynamometers, and supporting power and communication infrastructure, all connected to the AFRC Core simulation. Plans call for 18 high performance electric motors that will be powered by batteries and the turbogenerator, and commanded by a piloted simulation. Flight control algorithms will be developed on the turbo-electric distributed propulsion system.

distributed↗