Dynamic blade loading in the ERDA/NASA 100 kW and 200 kW wind turbines

Dynamic blade loads, including aerodynamic, gravitational, and inertial effects, are presented for two large horizontal-axis wind turbines: the ERDA-NASA 100 kW Mod-0 and 200 kw Mod-0A wind power systems. Calculated and measured loads are compared for an experimental Mod-0 machine in operation. Predicted blade loads are also given for the higher power Mod-0A wind turbine now being assembled for operation as part of a municipal power plant. Two major structural modifications have been made to the Mod-0 wind turbine for the purpose of reducing blade loads. A stairway within the truss tower was removed to reduce the impulsive aerodynamic loading caused by the tower wake on the downwind rotor blades. Also, the torsional stiffness of the yaw drive mechanism connecting the turbine nacelle to the tower was doubled to reduce rotor-tower interaction loads. Measured reductions in load obtained by means of these two modifications equaled or exceeded predictions.

Spera, D. A.↗

Niowave Design and Analysis of a 200 kW Converter

LANL is providing support to Niowave Inc. on the design and analysis of a 200 kW converter. The current design of the 200 kW (40 MeV, 5 mA electron beam) converter consists of LBE flowing from the top to the bottom. When compared to the Mk.5 20 kW converter, which flowed LBE from the bottom, flowing over a divider plate to create a waterfall, the 200 kW converter eliminates the divider plate, which would otherwise have melted with the higher beam power. Because the LBE flows from the top to the bottom, alternate methods to the divider plate need to be utilized to ensure a stable flow that minimizes splashing at the bottom of the LBE waterfall, while maintaining a uniform LBE thickness at the beam, and steady LBE flow at the desired flow rate.

43 PARTICLE ACCELERATORS↗

Design and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters

This paper presents a design and optimization methodology for a 200-kW medium-frequency transformer (MFT) based on low-loss magnetic core (FINEMET FT-3TL). The proposed optimal design methodology consists of predesign, preliminary design, and optimal design. In the preliminary design, the parallel-concentric winding structure is selected to increase the current carrying capability and reduce the leakage inductance. Based on the parallel-concentric winding concept, a novel cooing and insulation structure with 3-D printed bobbins are proposed. The optimal designed MFT prototype achieves a power density higher than 19.23 kW/L. The electrical insulation system is tested at 12 kV ac peak voltage. In addition, the partial discharge (PD) test is conducted at 7.5 kV ac peak voltage to ensure the PD-free design. The high-frequency bipolar pulsewidth modulation voltage insulation (PD) test is the first time applied in MFT design and test process. Finally, the transformer is applied in a dual-active-bridge (DAB) converter with 200 kW rated power. The peak efficiency of the DAB converter is 99.53%, and the efficiency at 200 kW is 98.85%. The peak efficiency of MFT is 99.844%, and the efficiency at 200 kW is 99.842%.

42 ENGINEERING↗

A 200-kW wind turbine generator conceptual design study

A conceptual design study was conducted to define a 200 kW wind turbine power system configuration for remote applications. The goal was to attain an energy cost of 1 to 2 cents per kilowatt-hour at a 14-mph site (mean average wind velocity at an altitude of 30 ft.) The costs of the Clayton, New Mexico, Mod-OA (200-kW) were used to identify the components, subsystems, and other factors that were high in cost and thus candidates for cost reduction. Efforts devoted to developing component and subsystem concepts and ideas resulted in a machine concept that is considerably simpler, lighter in weight, and lower in cost than the present Mod-OA wind turbines. In this report are described the various innovations that contributed to the lower cost and lighter weight design as well as the method used to calculate the cost of energy.

Source record↗

Utility operational experience on the NASA/DOE Mod-OA 200 kW Wind Turbine

The Mod-OA 200 kW Wind Turbine was designed and fabricated by the Lewis Research Center of the NASA under the direction of the U.S. Department of Energy. The project is a part of the Federal Wind Energy Program and is designed to obtain early wind turbine operation and performance data while gaining initial experience in the operation of large, horizontal axis wind turbines in typical utility environments. On March 6, 1978, the Mod-OA wind turbine was turned over to the Town of Clayton Light and Water Plant, Clayton, NM, for utility operation and on December 31, 1978 the machine had completed ten months of utility operation. This paper describes the machine and documents the recent operational experience at Clayton, NM.

Glasgow, J. C.↗

Modular Design of Receiver Side Power Electronics for 200 kW High Power Dynamic Wireless Charging System

Dynamic wireless power transfer (DWPT) can provide energy to EVs in motion and extend the drive range. By upscaling the charging power to 200 kW (High Power DWPT), the percentage of electrified roadway reduces and the solution becomes cost-effective. However, coil coupling-coefficient variation during vehicle movement fluctuates the transferred power which is unfavorable for vehicle battery. Secondary regulation design can smooth the power but the converter design becomes very challenging due to requirement in high power, high efficiency, fast control, as well as high power density since the unit will be onboard. This paper provides the modular design approach of a 200 kW secondary side unit to achieve high performance and scalability. The DC/DC converter using SiC devices demonstrated 98.3% efficiency.

Xue, Lincoln↗

Characterizing the plasma-induced thermal loads on a 200 kW light-ion helicon plasma source via infra-red thermography

The light-ion helicon plasma source of the Proto-MPEX linear plasma device has been recently upgraded to enable pulsed (0.5–1 s) operation up to 200 kW. The main objective of this work is to report on the plasma-induced surface heat fluxes incident on the helicon window during high power operation (60–150 kW net power) for the purpose of the design of the upcoming material plasma exposure eXperiment (MPEX). The IR imaging system and associated physics models for the extraction of surface heat fluxes are presented. Furthermore, experimental results demonstrate that the control of the plasma strike point via magnetic flux mapping and the use of dedicated limiters is effective at reducing the heat loads on the dielectric window. Moreover, it is found that the flux mapping must create a gap between the plasma and the dielectric window of at least the plasma radial decay length. Extrapolated to 200 kW net RF power, this mode of operation can reduce the power lost to the dielectric window by 33%. The results presented have direct application to the design of high-powered helicon plasma sources that operate in a steady state. Examples include linear divertor simulators such as MPEX, electric thrusters, negative ion sources for NBI and linear plasma–material interaction test stands.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electromagnetic Shielding Design for 200 kW Stationary Wireless Charging of Light-Duty EV

Wireless power transfer (WPT) is a developing technology with the advantage of convenience and flexible charging. SAE recommended practice J2954 defines typical size and geometry with aluminum or ferrite plate shielding to limit leakage electromagnetic (EM) fields for WPT with power levels lower than 22 kVA from the input side. However, as the WPT power goes up to 100- or 200-kW level, EM safety surrounding the WPT becomes a critical concern. To address this oncoming safety challenge, a novel ferrite shielding design is proposed in this paper. Different misalignment scenarios in accordance with definitions in SAE J2954 are also taken into consideration to ensure EM safety under various operation scenarios. Simulation results, which are preliminarily verified by magnetic field measurements at 1.1 m from the center of the vehicle side coil under 100 kW operation, indicate that the magnetic field leakage can be maintained below the limits defined in SAE J2954 for 200 kW operation. A 3.3 kW scale-down test was also carried out and compared to parallel scale-down simulations. 26.8% field emission reduction is observed from the scale-down test, which supports the effectiveness of the proposed shielding design.

Zhang, Bo↗

Electromagnetic Shielding Design for 200 kW Stationary Wireless Charging of Light-Duty EV

Wireless power transfer (WPT) is a developing technology with the advantage of convenience and flexible charging. SAE recommended practice J2954 defines typical size and geometry with aluminum or ferrite plate shielding to limit leakage electromagnetic (EM) fields for WPT with power levels lower than 22 kVA from the input side. However, as the WPT power goes up to 100- or 200-kW level, EM safety surrounding the WPT becomes a critical concern. To address this oncoming safety challenge, a novel ferrite shielding design is proposed in this paper. Different misalignment scenarios in accordance with definitions in SAE J2954 are also taken into consideration to ensure EM safety under various operation scenarios. Simulation results, which are preliminarily verified by magnetic field measurements at 1.1 m from the center of the vehicle side coil under 100 kW operation, indicate that the magnetic field leakage can be maintained below the limits defined in SAE J2954 for 200 kW operation. A 3.3 kW scale-down test was also carried out and compared to parallel scale-down simulations. 26.8% field emission reduction is observed from the scale-down test, which supports the effectiveness of the proposed shielding design.

25 ENERGY STORAGE↗

Simultaneous Convective and Radiative Heating of Materials with the 200 kW Laser Enhanced Arc Jet Facility (LEAF)

Recent installation of the 200-kW Laser Enhanced Arc Jet Facility (LEAF) at the Interaction Heating Facility (IHF) arc jet at NASA Ames Research Center has enabled combined heating of material samples. The LEAF system is permanently located adjacent to IHF. During LEAF operation, IHF can convectively heat material samples with heat fluxes up to 0.16 kW/cm 2 using the 22.86-cm nozzle or up to 0.07 kW/cm 2 using the truncated semi-elliptic nozzle. LEAF can deliver radiant heating with various profiles and sizes to a material sample. In flat-top square configuration, irradiance levels of nearly 0.1 kW/cm 2 have been demonstrated over a 43.2 x 43.2 cm area, and irradiance levels up to 0.39 kW/cm 2 have been demonstrated over a 15.2 x 15.2 cm area. LEAF can also be configured to deliver a super-Gaussian profile over a variety of beam diameters (1.8 to 5.6 cm). This configuration has been demonstrated up to peak irradiance levels of 25.7 kW/cm 2 per laser at the smallest, 1.8 cm, diameter setting. The LEAF system is composed of four 50-kW lasers, so it can also be configured to simultaneously deliver two different beam shapes (e.g., one square beam and one super-Gaussian beam).

Megan MacDonald↗

MOD-0A 200 kW wind turbine generator design and analysis report

The design, analysis, and initial performance of the MOD-OA 200 kW wind turbine generator at Clayton, NM is documented. The MOD-OA was designed and built to obtain operation and performance data and experience in utility environments. The project requirements, approach, system description, design requirements, design, analysis, system tests, installation, safety considerations, failure modes and effects analysis, data acquisition, and initial performance for the wind turbine are discussed. The design and analysis of the rotor, drive train, nacelle equipment, yaw drive mechanism and brake, tower, foundation, electricl system, and control systems are presented. The rotor includes the blades, hub, and pitch change mechanism. The drive train includes the low speed shaft, speed increaser, high speed shaft, and rotor brake. The electrical system includes the generator, switchgear, transformer, and utility connection. The control systems are the blade pitch, yaw, and generator control, and the safety system. Manual, automatic, and remote control are discussed. Systems analyses on dynamic loads and fatigue are presented.

Anderson, T. S.↗

Design and Analysis of a 200 kW Dynamic Wireless Charging System for Electric Vehicles

Dynamic wireless charging of electric vehicles can significantly alleviate or eliminate range anxiety while reducing the required on-board battery capacity. To achieve an electric vehicle charging balance with minimal infrastructure costs, power transfer levels around 200 kW are required. In this paper, a system architecture with a modularized power electronics and optimized power transfer couplers was adopted to enable efficient power transfer. A DC/DC converter was used for secondary-side charging control of the battery. The system performance was validated in an experimental setup at 120 kW with 91.31% efficiency from the DC input on the primary side to the vehicle battery.

Xue, Lincoln↗

Double-Side Cooled 1.2kV, 300A SiC MOSFET Phase-leg Modules for 200 kW, > 100 kW/L Traction Inverters

The packaging of a double-side cooled 1.2 kV, 149 A SiC phase-leg modules has been reported in recent years for making 100 kW, 100 kW/L traction inverters. Each phase-leg module consists of two SiC MOSFETs, one per switch position. Six of the phase-leg modules are assembled into a segmented inverter configuration to meet the power and power density requirement. In this work, the layout of the phase-leg module was redesigned to include four of the SiC MOSFETs, two per switch position, with the aim of doubling the power to 200 kW and increasing the power density beyond 100 kW/L, but with only a 10.25% footprint increase. Key features of the packaging technology developed in the previous work were implemented in the current work, which include silver sintering for chip bonding and porous silver inter-posts for bonding device source pads to substrate. Parasitic extraction simulation showed that the four-chip module has a low parasitic inductance of 4.7 nH, like the two-chip module. Static characterization of the four-chip prototypes showed a low average on-resistance of 9 mΩ and a low average leakage current of 5 nA at Vds of 1.2 kV.

Zhang, Zichen↗

The Sensitivity Analysis of Coil Misalignment for a 200-kW Dynamic Wireless Power Transfer System with an LCC-S and LCC-P Compensation

The dynamic wireless power transfer systems may reduce the battery size of electric vehicles while maintaining the travel range. Similar to the stationary wireless power transfer systems, the compensation networks are desired in dynamic wireless charging systems at the primary and secondary sides to reduce the reactive power requirement from the source and improve the efficiency. Consequently, it is essential to understand the behavior of the compensation networks, especially the sensitivity to misalignments. This paper presents a sensitivity analysis of LCC-S and LCC-P compensation networks for a 200-kW power transfer with variations in the coupling coefficient due to the electric vehicle travel and misalignments between the pads. The sensitivity study combines the electromagnetic finite element analysis and circuit analysis to determine the impact of misalignments on the wireless power transfer system characteristics. The theoretical analysis is verified by conducting circuit simulations at discrete points to verify the accuracy of the mathematical model.

Kavimandan, Utkarsh↗

Development of a 1 kW, 200 C Mapham Inventor

Electronic systems and components are often exposed to high temperature environment in space-based applications, nuclear power facilities, and geothermal energy extraction fields. A key requirement for these systems is, therefore, to withstand the high temperature exposure while maintaining efficient and reliable operation. Efforts were taken to design and develop a high temperature power inverter capable of 200 C operation. A 1 kW, 20 kHz Mapham inverter was designed and evaluated as a function of temperature at different load levels. The inverter system, excluding its input, control, and logic circuits, was characterized at temperatures from ambient to 200 C at 0%, 50%, and 100% resistive loading. With an applied input voltage of 75 VDC, the inverter produced an output of 250 VAC. The results obtained, which indicate good operational characteristics of the inverter up to 200 C, are presented and discussed.

Hammoud, Ahmad↗

Utility operational experience on the NASA/DOE MOD-0A 200-kW wind turbine

The Mod-0A 200 wind turbine was designed and fabricated as part of the Federal Wind Energy Program. Early wind turbine operation and performance data were obtained while gaining initial experience in the operation of large, horizontal axis wind turbines in typical utility environments. The Mod-0A wind turbine was turned over to the Town of Clayton Light and Water Plant, Clayton, NM, for utility operation and on December 31, 1978, the machine had completed ten months of utility operation. The machine is described and the recent operational experience at Clayton, NMis documented.

Glasgow, J. C.↗

An operating 200 kW horizontal axis wind turbine

Output from the 200-kilowatt machine will be enough to meet the power requirements of about 60 families. The experimental wind turbine generator (WTG) is a two-bladed, horizontal-axis, rotor system driving a synchronous electric generator through a step-up gear box located within a nacelle. The nacelle is mounted on top of a 100-foot tower with the rotor located downwind from the tower. The 200-kilowatt rated power output of the wind turbine is achieved at a turbine rotor speed of 40 rpm and a rated wind speed of 18.3 mph. The rated wind speed is defined as the lowest wind speed at which full power is achieved. Attention is given to operational details, aspects of blade design, blade fabrication, the use of strain gages, questions of aeroelastic stability, and an early analysis of test data.

Hunnicutt, C. L.↗

World’s First Vertical GaN based High Power (200 kW) Multi-level Traction Electric Drive Design

Vertical GaN (vGaN) technology leverages a fully conductive 3D semiconductor structure, enabling superior power density compared to GaN-on-Si and other wide bandgap devices. It offers a pathway to surpass cost and efficiency limitations of Si and SiC devices in traction applications. However, scaling for high-voltage, high-power systems remains challenging. This paper presents the design of an 800V, 200kW traction inverter utilizing vertical GaN devices. The inverter achieves ultra-high efficiency (> 99.5%) through advanced power module integration and employs multilevel neutral-point-less X-type (NPL.X) inverter topology to ensure optimal traction drive system performance. These innovations demonstrate the potential of vGaN for next￾generation electric propulsion systems.

Alam, Khorshed [General Motors LLC, Detroit, MI (U↗