Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Technical Justifications for Liquid Hydrogen Exposure Distances

The previous separation distances in the National Fire Protection Association (NFPA) Hydrogen Technologies Code (NFPA 2, 2020 Edition) for bulk liquid hydrogen systems lack a well-documented basis and can be onerous. This report describes the technical justifications for revisions of the bulk liquid hydrogen storage setback distances in NFPA 2, 2023 Edition. Distances are calculated based on a leak area that is 5% of the nominal pipe flow area. Models from the open source HyRAM+ toolkit are used to justify the leak size as well as calculate consequence-based separation distances from that leak size. Validation and verification of the numerical models is provided, as well as justification for the harm criteria used for the determination of the setback distances for each exposure type. This report also reviews mitigations that could result in setback distance reduction. The resulting updates to the liquid hydrogen separation distances are well-documented, retrievable, repeatable, revisable, independently verified, and use experimental results to verify the models.

08 HYDROGEN↗

All-digital Sensor System for Distributed Downhole Pressure Monitoring in Unconventional Fields

This project developed and validated (through field tests) a new low-cost all-digital pressure sensing technology for in situ distributed downhole pressure monitoring in unconventional oil and gas (UOG) fields. The all-digital sensing technology uses a built-in non-electric analog-to-digital converter (ADC) to transform the pressure information into a combination of binary (ON/OFF) states. As such, the system does not need downhole electronics for signal conditioning and telemetry. The all-digital sensors can be remotely logged over a long distance, and many sensors can be multiplexed for distributed sensing. Based on a review of unconventional wells in the Lower 48 states, the specification of the sensor is to measure pressure up to 69 MPa (10,000 psi) and temperature up to 250°C. A sensor with a helical bourdon sensing element and a digital signal decoder of 50 mm diameter and 109 mm length was constructed. The helical bourdon sensing element was made of 304L stainless steel and filled with motor oil. The digital converter was made up of 8 digital reading pads constructed of high-temperature epoxy with conductive inserts made of stainless steel. The sensor had a linear response to pressure with an accuracy of 0.14 MPa (20 psi). To withstand the high pressure, the sensor was enclosed in a stainless-steel pressure housing with a wall thickness of 5.5 mm, a diameter of 73 mm, and a length of 724 mm. In the laboratory tests, the sensor exhibited no temperature-related effects on the results. The sensor did not show drift over a 14-day test period at elevated pressure. A field test was conducted where the sensor was deployed in a test wellbore at the Quest drilling test facility to a depth of 0 feet over three weeks. The sensor was attached to the production rods, along with a downhole reference sensor of PPS27 type, which is a permanent downhole monitoring system. During the testing phase, the test well annular blow-out preventer was closed, and the well was pressurized at the surface to 11 MPa (1600 psi). The sensor read the elevated bottom hole pressure of 1500 psi. A multiplexing unit was created for the sensor to deploy multiple sensors on one data transmission line in a distributed approach. The multiplexing unit was tested in a simulated environment of 3048 m (10,000 ft) with five sensors distributed. The sensors were pressurized at different intervals. The multiplexed sensors recorded the correct pressure, and the multiplexing did not interfere with the readings. The proposed concept of an all-digital pressure sensor for harsh downhole environments was designed, manufactured, and tested in the laboratory and tested at the field to a up to 69 MPa and 250°C. This technology has high-temperature tolerance and has potential in downhole areas outside oil and gas, such as carbon capture and storage (CCS) and geothermal wells. The sensor concept has been proven in this project, but to create a commercially viable product, manufacturing a sensor with a smaller diameter needs to be performed.

02 PETROLEUM↗

CCUS 2024, Interpreting the strain tensor Larry Murdoch Interpreting strain tensor data to characterize and monitor reservoirs for CO2 storage and other applications

Recent advances in instrumentation have made it feasible to measure the transient strain tensor caused by small changes in fluid volume or pressure in the subsurface and this has opened the door to new opportunities for characterization and monitoring during CCUS. We have demonstrated this method by deploying strainmeters at shallow depths (30 to 40m) and then conducting injection well tests in an underlying reservoir at 530m depth. The resulting data indicated that the horizontal strain at shallow strainmeters was tensile and the vertical strain was compressive. The radial strain was less than the horizontal strain, and the strain rates decreased from 100 nanostrain/day to roughly 10 ne/d over a few days (1 nanostrain = 1 part per billion strain). We then used the strain data to estimate reservoir properties, geometry and pressure through inversion of poroelastic forward models using both numerical and novel analytical methods. The average horizontal strain in the caprock resembles the transient pressure in the underlying reservoir and classic type-curve methods from transient well testing can be used for preliminary interpretations of strain data. We have developed fast, closed-form analytical solutions to a pressurized poroelastic inclusion and inhomogeneity in a half-space. Numerical models developed using finite element methods allow more details of the subsurface to be included in the inversion, but they require much longer run times and this makes inversion cumbersome using standard methods. We have developed an inversion approach that uses a proxy model created using machine learning to do most of the forward calculations. This approach markedly reduces the computational requirements and makes it feasible to use Bayesian inversion with large numerical models. Bayesian inversion is important because it provides predictions with uncertainties, which makes the results useful for decision making. We have shown with field tests and simulations that the strain tensor in the caprock is sensitive to pressure in the reservoir, reservoir properties and boundaries, and pressure in the caprock caused by leaks. These results indicate that measuring and interpreting the shallow strain tensor could be a valuable tool for both initial reservoir characterization efforts and long-term monitoring during CCUS. Recent advances in instrumentation have made it feasible to measure the transient strain tensor caused by small changes in fluid volume or pressure in the subsurface and our objective was to evaluate opportunities for strain monitoring during characterization and monitoring for CCUS. Our approach was to deploy strainmeters at shallow depths (30 to 40m) and then conduct injection well tests in an underlying reservoir at 530m depth. The results indicate that the horizontal strain at shallow strainmeters was tensile and the vertical strain was compressive. The radial strain was less than the horizontal strain, and the strain rates decreased from 100 nanostrain/day to roughly 10 ne/d over a few days (1 nanostrain = 1 part per billion strain). We then used the strain data to estimate reservoir properties, geometry and pressure through inversion of poroelastic forward models using both numerical and novel analytical methods. The average horizontal strain in the caprock resembles the transient pressure in the underlying reservoir and classic type-curve methods from transient well testing can be used for preliminary interpretations of strain data. We have developed fast, closed-form analytical solutions to a pressurized poroelastic inclusion and inhomogeneity in a half-space. Numerical models developed using finite element methods allow more details of the subsurface to be included in the inversion, but they require much longer run times and this makes inversion cumbersome using standard methods. We have developed an inversion approach that uses a proxy model created using machine learning to do most of the forward calculations. This approach markedly reduces the computational requirements and makes it feasible to use Bayesian inversion with large numerical models. Bayesian inversion is important because it provides predictions with uncertainties, which makes the results useful for decision making. In conclusion, we have shown with field tests and simulations that the strain tensor in the caprock is sensitive to pressure in the reservoir, reservoir properties and boundaries, and pressure in the caprock caused by leaks. These results indicate that measuring and interpreting the shallow strain tensor could be a valuable tool for both initial reservoir characterization efforts and long-term monitoring during CCUS.

Murdoch, Larry↗

Mark-18A Cold Runs

The Savannah River National Laboratory (SRNL) is tasked by the National Nuclear Security Administration (NNSA) to recover highly valued isotopes from irradiated Mark-18A (Mk-18A) targets. The Savannah River Site (SRS) has sixty-five Mk-18A targets available for the recovery of the high valued materials. The sixty-five Mk-18A targets are currently stored in the L-Area Basin and will be removed one at a time and individually transported to SRNL. Upon receipt at SRNL, the Mk-18A target material will be removed from the confinement, dissolved, chemically separated, and calcined to a stable oxide. The flowsheet is designed to recover the plutonium as well as the trivalent actinides. The remaining unrecovered material will be discarded to the high activity drain (HAD) system in SRNL. A specially designed cask was procured for transport of the targets from L-Area to SRNL. Once received at SRNL, the targets will be loaded into the back of Cell 7 and resized as they enter the cell. The resized targets (1/4 lengths) will then be processed one at a time through the following processes: caustic dissolution and filtration; acidic dissolution and filtration, Reillex anion exchange, diglycolamide (DGA) cation exchange; and DGA calcination. This processing will result in two product streams. The first is an aqueous plutonium solution which will be removed from the shielded cells and taken to a glovebox for further purification and conversion to an oxide. The second is a calcined oxide containing the Am and Cm as well as other lanthanide fission products which will be removed from the shielded cells using a bagless transfer system. Both materials will be packaged for shipment to Oak Ridge National Laboratory (ORNL). All equipment to carry out this process was designed, procured or fabricated, and installed in a mock-up facility (716-4A) at SRS to allow for simulation testing in a non-radioactive area. This equipment was then dismantled and transferred from 716-4A to 773-A and installed in the SRNL Shielded Cells. After installation in the shielded cells facility testing was performed using water followed by surrogates and cold chemicals. Issues were identified during these evaluations, including equipment issues as well as technical challenges. Many of the issues were rectified during performance of the cold runs, and the remaining have a resolution identified. Table ES-1 provides a summary of all issues identified during the cold run operations, as well as the status and identified resolutions to outstanding issues.

07 ISOTOPE AND RADIATION SOURCES↗

Risk of theft and malicious use of radiation sources in transit

Remote radioactive source applications require frequent transportation of sources from storage locations to remote sites. This introduces risk of theft of a source during the transportation process, with the level of risk proportional to the radioactivity of the source. To that end, theft of smaller sources, such as microcurie-level moisture density gauges, are of minor concern, but larger sources, such as those used for radiography and well logging, present more risk. Radiography sources include 192 Ir, 75 Se, or 60 Co radionuclides with radioactivity amounts at or exceeding IAEA Category 2. Well-logging sources, primarily 241 Am/Be, are used for their neutron-emission properties. 137 Cs is also used in well-logging at lower activities than in radiography but at levels that still present some risk. The vulnerability for malicious use of such sources to cause contamination and associated economic effects is dependent on the elemental chemical and physical properties, especially melting point and bulk modulus. Theft of radiography sources is somewhat common, well-logging sources less so. Theft of sources commonly occurs in concert with theft of the vehicle, with the source subsequently abandoned. There have been some instances where a source appears to have been specifically targeted. There are a variety of security measures and protocols, available and under development, to mitigate the risk of theft and assist in source recovery.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Bryan Mound Collar Compression Study

This report presents a study of collar compression for the wells at the Bryan Mound site. The study includes a comprehensive review of all available Multi-Arm Caliper (MAC) logs from the site, which has been used to identify specific wells that are experiencing casing restrictions at collar joints. Additional site-wide analysis of Bryan Mound well temperature data, proximity to sulphur wells, pulsed eddy current (PEC) logs, and a general spatial analysis has been included.

02 PETROLEUM↗

Computed Tomography Scanning and Petrophysical Measurements of Eastern Williston Basin Twin Buttes and Hagel Formations

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize core from two wells that represent coal resources across North Dakota. These include the MC23080C Well in Mercer County and the 23-B001 Well in Oliver County. The primary impetus of this work was to capture a detailed digital representation of the core from the MC23080C and 23-B001 Wells. The collaboration between the NETL and the Energy and Environment Research Center (EERC) enables other research entities to access information about this potential carbon ore, rare earth, and critical mineral resource plays in the Williston Basin. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. Fractures, discontinuities, and millimeter-scale features were readily detectable with the medical CT scanner acquired images. Imaging with the NETL medical CT scanner was performed on entire cores. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), gamma density, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for potential future analysis. Higher-resolution industrial and micro-CT images were acquired from selected zones along the depth of the core to visualize the structure in higher detail. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core, with the resulting macro- and micro-descriptions relevant to many subsurface energy-related examinations traditionally performed at NETL.

01 COAL, LIGNITE, AND PEAT↗

2024 Geothermal Rising Conference Poster

As part of a U.S. DOE Geothermal Technologies Office funding opportunity, Geysers Power Company, LLC, an indirect subsidiary of Calpine Corporation, partnered with Sandia National Labs, EGI at the University of Utah, and Texas A&M University to demonstrate increased drilling performance at The Geysers Geothermal Field. The performance target in the drilling demonstrations is at least a 25% improvement in rates of penetration with increased time on bottom for each bit. The planned drilling demonstrations are being conducted as part of an existing drilling campaign intended to enhance reservoir utilization. A major goal of the project is to assess the effectiveness of implementing mechanical specific energy (MSE) and drilling dysfunction diagnosis and remediation in these challenging environments, as well as alternate bit technologies. The first demonstration well has been completed, with a total of 15 PDC bit runs in the 17.5”, 12.25” and 8.5” sections. Initial analysis shows ROP gains in all three hole sections, especially in the 17.5” and 12.25” sections, compared with conventional roller cone bit runs in the demonstration well and offset wells. However in the 8.5” hole, wear and damage to the PDC bits resulted in relatively short bit runs. Analysis is underway to take advantage of the positive results and remediate the challenges.

15 GEOTHERMAL ENERGY↗

Fundamental Studies of the Vibrational, Electronic, and Photophysical Properties of Tetrapyrrolic Architectures

The ability to capture and utilize light in the near-ultraviolet (NUV), visible and near-infrared (NIR-I and NIR-II) spectral regions (i.e., 320–400, 400–700, 700–1000, 1000–1700 nm) is essential for any solar-energy conversion scheme. Nature employs chlorophylls and bacteriochlorophylls in light-harvesting architectures to absorb light in the blue and red/NIR regions. Accessory pigments (carotenoids, bilins) augment absorption of the (bacterio)chlorophylls in the green region. The harvested energy is funneled to a reaction center protein, where charge separation occurs. Subsequent migration of the electron and the hole stabilizes and stores the energy from light via redox chemistry. The long-term objective of the Bocian/Holten&Kirmaier/Lindsey research program under this DOE grant has been to develop tetrapyrrole-based molecular architectures that absorb sunlight, funnel energy and separate charge with high efficiency. Integral to the program has been iterative cycles of design, synthesis and characterization that provided deep insights into the relationships between chemical composition, electronic structure, and key static and dynamic properties (vibrational, redox, photophysical, energy/charge transfer) of tetrapyrrolic systems. Such architectures included monomers, dyads, larger arrays, and complexes with accessory components. The objective was to develop molecular designs and guiding principles to enhance current and future energy-conversion schemes. Molecular arrays targeted to address one or more fundamental questions concerning light harvesting and energy/charge transfer were constructed from analogues of the naturally occurring hemes, chlorophylls and bacteriochlorophylls. Diverse, tunable synthetic building blocks were prepared that spanned the three respective tetrapyrrole families, which are the porphyrins, chlorins and bacteriochlorins. Thus, the research focused on porphyrins as well as synthetic surrogates for chlorophylls (chlorins, 13 1 -oxophorbines and chlorin-imides) and bacteriochlorophylls (bacteriochlorins, bacterio-13 1 -oxophorbines and bacteriochlorin-imides), generically termed hydroporphyrins. Although the three tetrapyrrole classes (porphyrins, chlorins and bacteriochlorins) absorb light strongly in the violet-blue spectral region, the long-wavelength absorption band typically lies in the green-orange, red, and NIR regions, respectively, with increasing intensity. Understanding the spectra, electronic structure, and energy/charge-transfer properties of such tetrapyrrolic macrocycles is of central importance for the rational design of molecular architectures for solar-energy conversion. Our integrated program of molecular design and synthesis coupled with a variety of spectroscopic, electrochemical, and computational studies have probed from first principles how structural and electronic properties of tetrapyrrolic macrocycles dictate spectral properties as well as the rates of ground-state hole/electron transfer and excited-state energy flow in multicomponent architectures. Individual molecules and multicomponent architectures were designed to test ideas of fundamental importance, often requiring the development of new synthetic methodology. The members of the collaborative team had almost daily discussions by phone and/or e-mail concerning design of molecules, flow of compounds between the labs, planning of physical characterization studies, discussing results and analysis and integrating into design of next generation architectures, and the preparation of manuscripts. Furthermore, students and postdocs in the different labs routinely communicated with one another to facilitate the advancement of the research activities. In short, a highly integrated and collaborative research program was well established among the groups. The research effort involved molecular design and synthesis of synthetic molecular architectures by the Lindsey group integrated with physicochemical and photophysical characterization by the Bocian group and the Holten&Kirmaier group (Figure 2). The Bocian group carried out electrochemical, electron paramagnetic resonance (EPR), resonance Raman (RR), and Fourier-transform infrared (FT-IR) studies, as well as density functional theory (DFT) calculations and the time-dependent extension (TDDFT) to gain insight into excited-state properties. The Holten&Kirmaier group carried out static and time-resolved absorption and fluorescence spectroscopy studies and simulated absorption spectra using molecular orbital (MO) energies from DFT as input to the four-orbital model to complement the TDDFT calculations. The combined measurements provided understanding of the vibrational/electronic properties of the individual molecules and the changes that occur upon incorporation into multicomponent architectures. This information underpinned elucidating the mechanisms and timescales of ground-state hole/electron transfer and excited-state energy and charge transfer.

14 SOLAR ENERGY↗

Calendar Year 2023 Underground Test Area Annual Sampling Letter Report Nevada National Security Site

The calendar year 2023 annual sampling letter report presents Plan implementation and a summary of field activities, sampling methods, well completion diagrams, and analytical laboratory results from sampling of wells associated with the Pahute Mesa CAUs. The CY 2023 letter report also presents data from samples collected from Well ER-EC-11_p3 as part of a sampling investigation. This well was resampled because of anomalously low standard tritium (3H) results from bailer sampling that occurred in July 2021.

54 ENVIRONMENTAL SCIENCES↗

Cements and a Modeling Tool to Calculate their Viability under Various Exploitation Conditions of HT RTES Systems

Primary cementing is the most important operation performed on a subterranean reservoir. Cement, placed in the annulus between the casing and the formations serves as a hydraulic seal preventing fluids and gas migrations, protecting steel casing from corrosion and supporting the well structure. Poor cementing jobs can be directly responsible for wells not reaching their full capacity, casing corrosion, compromised well integrity and, in the worst-case scenarios, well collapse.

15 GEOTHERMAL ENERGY↗

Ascorbic Acid Stability and pH Testing to Support RWM-018 Pilot Scale Wellhead Treatment System Feasibility Determination

A multitude of groundwater remediation techniques for chlorinated volatile organic compounds (cVOCs) have been conducted at the A/M-Areas of the Savannah River Site (SRS). Historical in-situ chemical oxidation (ISCO) injections of potassium permanganate and sodium persulfate conducted in 2018 and 2020, have left residual oxidant concentrations in the A/M-Area groundwater system. ISCO events targeted dense non-aqueous phase liquids (DNAPLs) through the injection of strong oxidants within plume zones upgradient of current groundwater recovery wells RWM-008 and RWM-018. These residual oxidants could significantly impede the operation of the mercury removal system needed to meet National Pollutant Discharge Elimination System (NPDES) permit requirements for the ongoing pump-and-treat system that hydraulically controls potions of the A/M-Area plume. Effluent treated groundwater from this system is discharged to surface water at the receiving outfall of the M-1 Air Stripper. To prevent interference of the M-1 Air Stripper system by residual oxidants, groundwater recovery has been ceased at well RWM-018. Modeling of oxidant transport in A/M-Area from ISCO estimated that the potential oxidant load contributed by RWM-018 could be as high as 120 mg/L. It is also possible that oxidants may be contributed via pumping at well RWM-008 in the near future as residual oxidants within the aquifer migrate toward its zone of influence. Savannah River National Laboratory (SRNL) has conducted research to investigate potential pre-treatment chemicals to neutralize these residual oxidants, before reaching the M-1 Air Stripper, to allow for resumed groundwater recovery at RWM-018 and continued pumping at RWM-008. Deployment of ascorbic acid for neutralization of residual oxidants at RWM-018 (and possibly RWM-008) is recommended based on results from previous reductant testing (SRNL, 2021). For a maximum estimated oxidant load at RWM-0018, a well-head treatment system would need to dose about 400 gallons of ascorbic acid each month to ensure complete neutralization. A second system with additional reagent should also be considered for deployment at RWM-008.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RePED 250: A Revolutionary, High Drilling Rate, High-T Geothermal Drilling System and Companion Power Electronics

Geothermal drilling in the United States is drastically slower and more costly than Oil and Gas (O&G) drilling, primarily due to the additional challenges in geothermal wells: hard rock types and high temperatures. The Repetitive Pulsed Electric Drill (250°C) (RePED-250), developed by Tetra Corporation has the potential to change this with a novel electro-crushing technology. RePED-250 releases pulses of electricity through the rock, which causes it to break in tension, instead of compression like conventional rotary drilling. The tensile strength of hard rocks like granite is only ~5% of their compressive strength, requiring less energy, time, and wear on the bit compared to conventional drilling. The RePED drill bit has no moving parts, uses drilling mud to remove rock fragments, and uses standard drill pipe, enabling a direct transition from conventional drilling systems. The objective of this project is to move RePED technology towards commercial readiness for high-temperature geothermal applications. This involves: 1) Creating high-temperature, high power electronic components for the RePED drill capable of operating at the high temperatures of a geothermal well. The target is a 250°C ambient environment. Specifically, capacitors, high voltage switches, and a downhole generator capable of generating the necessary power. 2) Demonstrating RePED’s effectiveness drilling through hard rock (granite) and examining its pathway to commercialization and effect on the US geothermal market. Work on this project has led to significant improvement over the state-of-the-art for all the examined electronics, through design, modeling, and testing of these novel components, though some additional development is still needed to deploy these high-temperature parts in a geothermal well. Besides their use in RePED-250, each component has applications in other industries where the stability of electronics at high-temperature is needed. To address the second barrier to commercialization, a 9” hole was drilled through a sample block of granite, demonstrating the tool’s effectiveness in hard rock. The team investigated RePED-250’s effect on well cost and the geothermal industry, through various techno-economic models described in the report.

15 GEOTHERMAL ENERGY↗

Development Fiber Optic Distributed System for Direct Detection of Subsurface Gases Leakages

Carbon, natural gas, and hydrogen gas storage is an emerging solution to safeguard us against pollution, support goals of negative carbon emission, and protect sources of renewable energy. Properly constructed storage wells provide a virtually impervious barrier to any unintended subsurface transmission. The ability to ensure the long-term integrity of such wells is vital to the success of any storage operation and be successful in the public eyes. Therefore, robust monitoring of any gas migration into the subsurface is highly sought. A fiber-optic distributed chemical sensor (DCS) enables monitoring of long-term well integrity along its depth, ensuring the success of any storage operation and bolsters public acceptance of the safety of the reservoir via leak early detection. The same technique can be applied to gas monitoring in pipeline networks and nuclear stockpile monitoring applications. Fiber based Raman spectroscopy enables DCS, as optical fibers can be deployed in virtually any environment and relay spectroscopic information over long distances back to the user. Hollow core fibers (HCF) make excellent DCSs as the air core of the fiber allows gas from the environment to diffuse into the core, which interacts with the laser signal that is carried in the air core. This work builds upon the previous LDRD project, Fiber Optic System for Direct Detection of Carbon Dioxide Leakage in Carbon Storage Wells (21-FS-003), in which the feasibility of Raman spectroscopy detection of Carbon Dioxide (CO2) in HCF detection was demonstrated. We mitigated the risk of this DCS technology by establishing and completing five objectives. The first objective was to model and optically characterize HCF uptake of CO2, establishing the relationship between HCF length, gas diffusion time, detectable gas concentration, and measured Raman intensity. In objective two, we developed a fiber core drilling recipe to enable additional diffusion ports in the fiber core and established a method for maintaining fiber strength and integrity post drilling. Objective three characterized the drilled fibers against the undrilled fibers, establishing the differences in the gas mechanics and optical properties and provided parameters to iterate the drilling process. In objective four, a fusion splicing technique was developed to join the HCF to conventional single-mode fibers, localizing the gas detection point at the drilled HCF hole, emulating a DCS. Lastly, objective five was the testing of the sensor in Edgar Mines at Colorado School of Mines on a CO2 pipeline with a simulated leak, to showcase the ability to detect CO2 leaks. This capstone result showed CO2 leak detection in < 10 minutes, raising the technology readiness level of HCF segments as deployable DCS.

organic↗

RePED 250: A Revolutionary, High Drilling Rate, High-T Geothermal Drilling System and Companion Power Electronics (Final Report)

Geothermal drilling in the United States is drastically slower and more costly than Oil and Gas drilling, primarily due to the additional challenges in geothermal wells: hard rock types and high temperatures. The Repetitive Pulsed Electric Drill (250 degrees C) (RePED-250), developed by Tetra Corporation has the potential to change this with a novel electro-crushing technology. RePED-250 releases pulses of electricity through the rock, which causes it to break in tension, instead of compression like conventional rotary drilling. The tensile strength of hard rocks like granite is only ~5% of their compressive strength, requiring less energy, time, and wear on the bit than conventional drilling. The RePED drill bit has no moving parts, uses drilling mud to remove rock fragments, and standard drill pipe, enabling a direct transition from conventional drilling systems. The objective of this project is to move RePED technology towards commercial readiness for high-temperature geothermal applications. This involves: 1) Creating high-temperature, high power electronic components for the RePED drill capable of operating at the high temperatures of a geothermal well. The target is a 250 degrees C ambient environment. Specifically, capacitors, high voltage switches, and a downhole generator capable of generating the necessary power. 2) Demonstrating RePED's effectiveness drilling through hard rock (granite) and examining its pathway to commercialization and effect on the US geothermal market. Work on this project has led to significant improvement over the state-of-the-art for all the examined electronics, through design, modeling, and testing of these novel components, though some additional development is still needed to deploy these high-temperature parts in a geothermal well. Besides their use in RePED-250, each component has applications in other industries where the stability of electronics at high-temperature is needed. To address the second barrier to commercialization, a 9" hole was drilled through a sample block of granite, demonstrating the tool's effectiveness in hard rock. The team investigated RePED-250's effect on well cost, and the geothermal industry, through various models described in the report.

15 GEOTHERMAL ENERGY↗

Mining and Validating Social Media Data for COVID-19–Related Human Behaviors Between January and July 2020: Infodemiology Study

Background: Health authorities can minimize the impact of an emergent infectious disease outbreak through effective and timely risk communication, which can build trust and adherence to subsequent behavioral messaging. Monitoring the psychological impacts of an outbreak, as well as public adherence to such messaging, is also important for minimizing long-term effects of an outbreak. Objective: We used social media data from Twitter to identify human behaviors relevant to COVID-19 transmission, as well as the perceived impacts of COVID-19 on individuals, as a first step toward real-time monitoring of public perceptions to inform public health communications. Methods: We developed a coding schema for 6 categories and 11 subcategories, which included both a wide number of behaviors as well codes focused on the impacts of the pandemic (eg, economic and mental health impacts). We used this to develop training data and develop supervised learning classifiers for classes with sufficient labels. Classifiers that performed adequately were applied to our remaining corpus, and temporal and geospatial trends were assessed. We compared the classified patterns to ground truth mobility data and actual COVID-19 confirmed cases to assess the signal achieved here. Results: We applied our labeling schema to approximately 7200 tweets. The worst-performing classifiers had F1 scores of only 0.18 to 0.28 when trying to identify tweets about monitoring symptoms and testing. Classifiers about social distancing, however, were much stronger, with F1 scores of 0.64 to 0.66. We applied the social distancing classifiers to over 228 million tweets. We showed temporal patterns consistent with real-world events, and we showed correlations of up to –0.5 between social distancing signals on Twitter and ground truth mobility throughout the United States. Conclusions: Behaviors discussed on Twitter are exceptionally varied. Twitter can provide useful information for parameterizing models that incorporate human behavior, as well as for informing public health communication strategies by describing awareness of and compliance with suggested behaviors.

60 APPLIED LIFE SCIENCES↗

High Temperature Mechanical Behavior of Refractory Alloys with Digital Image Correlation

Gas turbine efficiency is typically limited by the maximum allowable temperature for components at the inlet side and in the hot gas flow. Refractory alloys and SiC/SiC ceramic-matrix composites (CMCs) are promising candidates for advancing operating temperatures beyond those of Ni-based alloys (>1200 °C). Refractory alloys are more suitable than SiC/SiC CMCs for dynamic components, due to the latter's low toughness and ductility. However, it is well known that refractory alloys suffer from poor oxidation behavior under service lifetimes and conditions, leading to embrittlement concerns. The ARPA-E ULTIMATE program has set out to combine new alloys with advanced coatings to mitigate oxidation/embrittlement effects, while increasing the mechanical performance benefits of refractory materials. Low oxygen (inert gas) or vacuum systems are needed to assess high temperature mechanical performance of developed alloys. To investigate the environmental sensitivity of candidate alloys and develop high temperature testing capabilities, four argon tensile frames were upgraded as well as a single vacuum system at Oak Ridge National Laboratory. Digital image correlation was incorporated into the vacuum frame allowing for surface strain determination and refined insight into thermomechanical response. Creep testing was performed at 1300 °C on two alloys, C-103 and MHC in vacuum and high purity argon environments. The Mo-based alloy showed less sensitivity to oxygen, indicating that testing in well-controlled argon environments may be suitable. The C-103 alloy demonstrated a stronger sensitivity to oxygen in the well-controlled argon environment, illustrating the need for the developed vacuum testing capabilities. “Small” 25 mm and “large” 76 mm MHC specimens showed comparable results in terms of strain rate during creep testing and ultimate tensile strength during tensile testing, suggesting the viability of smaller geometries that use less material of advanced developmental alloys.

Bell, Sam↗

A Geospatial Cost Comparison of CO2 Plume Geothermal (CPG) Power and Geologic CO2 Storage

CO 2 Plume Geothermal (CPG) power plants can use gigatonne-levels of CO 2 sequestration to generate electricity, but it is unknown if the resources that support low-cost CPG power align with the resources that support low-cost CO 2 sequestration. Here, we estimate and compare the geospatially-distributed cost of CPG and CO 2 storage across a portion of North America. We find that the locations with lowest-cost CO 2 storage are different than the locations with lowest-cost CPG. There are also locations with low-cost CO 2 storage (<$5/tCO 2 ) that do not support CPG power generation due to insufficient reservoir transmissivity or temperature. Thus, CPG development may require electricity prices that are greater than the levelized cost of electricity (LCOE) to offset the increased cost of sequestration. We introduce the “Additional Cost of Electricity (ACOE)” metric to account for this cost and add it to the LCOE to calculate breakeven electricity prices that are required for CPG development. We find that breakeven prices are lower when new CO 2 injection wells are drilled specifically for CPG (i.e., “greenfield” CPG development) compared to if only existing CO 2 sequestration injection wells are used (i.e., “brownfield” CPG development). This is because comparatively few wells are needed for sequestration-only, and the increased power capacity from having more CPG wells outweighs the increased costs from more drilling. We also find that sequestered CO 2 could be used to approximately triple the United States geothermal electricity power capacity via a single CPG “sweet spot” in South Dakota, but that breakeven electricity price for this development is on the order of $200/MW e h.

15 GEOTHERMAL ENERGY↗