Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vessel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Subintimal Recanalization of Occluded Stents: The Substent Technique

PurposeApplication of metal stents is complicated by neointimal hyperplasia leading to vessel restenosis and reocclusion. Treatment options in cases presenting with complete occlusion of the stented segment and recurrent critical limb ischemia (CLI) are limited. We present the option of the subintimal/substent technique in dealing with occluded stents.MethodsThe study included patients presenting with recurrent CLI due to impaired blood flow as a result of complete occlusion of previously inserted metal stents and unsuccessful intraluminal crossing of the lesion via either the antegrade or retrograde approach. In these cases, crossing the occlusion through the subintimal/substent plane was attempted. Primary end points included technical success, safety of the procedure, clinical improvement, and limb salvage, while secondary end points were patient survival, primary patency, and vessel restenosis rates at 1-year follow-up. Study end points were calculated by Kaplan-Meier survival analysis.ResultsBetween July 2006 and October 2011, a total of 14 patients (mean age 69.14 {+-} 12.59 years, 12 men) were treated with the substent technique and included in the analysis. Technical success rate was 85.71 % (12 of 14), with a total lesion length of 193.57 {+-} 90.78 mm. The mean occluded stented segment length was 90.21 {+-} 44.34 mm. In 10 (83.33 %) of 12 cases, a new stent had to be placed by the side of the old occluded one, while the remaining two cases (16.67 %) were treated only with balloon angioplasty. No serious adverse events were noted during the immediate postprocedural period. All successfully treated patients improved clinically. Estimated limb salvage was 90.9 %, and patient survival rate was 90.0 % at 1 year's follow-up. Primary patency was 45.50 % and vessel restenosis 77.30 %.ConclusionSubintimal recanalization of occluded metal stents through the substent plane is a valuable alternative treatment option, especially in patients with recurrent CLI with few alternatives.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Management of Extra-cranial Supra-aortic Vascular Injuries

Supra-aortic vessel injuries are uncommon but can be life-threatening and surgically challenging. Trauma to these vessels may be blunt or penetrating, including iatrogenic trauma following the insertion of central venous lines, which may be preventable. Recent advances in technology have resulted in endovascular therapy becoming a common first-line treatment, and interventional radiologists now play a major role in the management of these vascular injuries. We review the literature on the endovascular management of these types of injuries and describe a spectrum of case-based extra-cranial supra-aortic vascular injuries managed at our institution and the range of imaging appearances, including active contrast extravasation, traumatic vessel occlusion, true aneurysms, pseudoaneurysms, and arteriovenous fistulae.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Root Cause Analysis of Gastroduodenal Ulceration After Yttrium-90 Radioembolization

Introduction: A root cause analysis was performed on the occurrence of gastroduodenal ulceration after hepatic radioembolization (RE). We aimed to identify the risk factors in the treated population and to determine the specific mechanism of nontarget RE in individual cases. Methods: The records of 247 consecutive patients treated with yttrium-90 RE for primary (n = 90) or metastatic (n = 157) liver cancer using either resin (n = 181) or glass (n = 66) microspheres were reviewed. All patients who developed a biopsy-proven microsphere-induced gastroduodenal ulcer were identified. Univariate and multivariate analyses were performed on baseline parameters and procedural data to determine possible risk factors in the total population. Individual cases were analyzed to ascertain the specific cause, including identification of the culprit vessel(s) leading to extrahepatic deposition of the microspheres. Results: Eight patients (3.2 %) developed a gastroduodenal ulcer. Stasis during injection was the strongest independent risk factor (p = 0.004), followed by distal origin of the gastroduodenal artery (p = 0.004), young age (p = 0.040), and proximal injection of the microspheres (p = 0.043). Prolonged administrations, pain during administration, whole liver treatment, and use of resin microspheres also showed interrelated trends in multivariate analysis. Retrospective review of intraprocedural and postprocedural imaging showed a probable or possible culprit vessel, each a tiny complex collateral vessel, in seven patients. Conclusion: Proximal administrations and those resulting in stasis of flow presented increased risk for gastroduodenal ulceration. Patients who had undergone bevacizumab therapy were at high risk for developing stasis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanical Thrombectomy of Iliac Vein Thrombosis in a Pig Model Using the Rotarex and Aspirex Catheters

Purpose: To investigate the efficacy and safety of mechanical thrombectomy for iliac vein thrombosis using Rotarex and Aspirex catheters in a pig model. Materials and Methods: Iliac vein thrombosis was induced in six pigs by means of an occlusion-balloon catheter and thrombin injection. The presence of thrombi was verified by digital subtraction angiography (DSA) and computed tomography (CT). Thrombectomy was performed using 6F and 8F Rotarex and 6F, 8F, and 10F Aspirex catheters (Straub Medical AG, Wangs, Switzerland). After intervention, DSA and CT were repeated to evaluate the efficacy of mechanical thrombectomy and to exclude local complications. In addition, pulmonary CT was performed to rule out pulmonary embolism. Finally, all pigs were killed, and iliac veins were dissected to perform macroscopic and histological examination. Results: Thrombus induction was successfully achieved in all animals as verified by DSA and CT. Subsequent thrombectomy lead to incomplete recanalization of the iliac veins with residual thrombi in all cases. However, the use of the 6F and 8F Rotarex catheters caused vessel perforation and retroperitoneal hemorrhage in all cases. Application of the Aspirex device caused one small transmural perforation in a vessel treated with a 10F Aspirex catheter, and this was only seen microscopically. Pulmonary embolism was detected in one animal treated with the Rotarex catheters, whereas no pulmonary emboli were seen in animals treated with the Aspirex catheters. Conclusion: The Aspirex catheter allowed subtotal and safe recanalization of iliac vein thrombosis. In contrast, the use of the Rotarex catheter caused macroscopically obvious vessel perforations in all cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Can Early Computed Tomography Angiography after Endovascular Aortic Aneurysm Repair Predict the Need for Reintervention in Patients with Type II Endoleak?

PurposeThis study was designed to identify parameters on CT angiography (CTA) of type II endoleaks following endovascular aortic aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA), which can be used to predict the subsequent need for reinterventions.MethodsWe retrospectively identified 62 patients with type II endoleak who underwent early CTA in mean 3.7 ± 1.9 days after EVAR. On the basis of follow-up examinations (mean follow-up period 911 days; range, 373–1,987 days), patients were stratified into two groups: those who did (n = 18) and those who did not (n = 44) require reintervention. CTA characteristics, such as AAA, endoleak, as well as nidus dimensions, patency of the inferior mesenteric artery, number of aortic branch vessels, and the pattern of endoleak appearance, were recorded and correlated with the clinical outcome.ResultsUnivariate and receiver operating characteristic curve regression analyses revealed significant differences between the two groups for the endoleak volume (surveillance group: 1391.6 ± 1427.9 mm{sup 3}; reintervention group: 3227.7 ± 2693.8 mm{sup 3}; cutoff value of 2,386 mm{sup 3}; p = 0.002), the endoleak diameter (13.6 ± 4.3 mm compared with 25.9 ± 9.6 mm; cutoff value of 19 mm; p < 0.0001), the number of aortic branch vessels (2.9 ± 1.2 compared with 4.2 ± 1.4 vessels; p = 0.001), as well as a “complex type” endoleak pattern (13.6 %, n = 6 compared with 44.4 %, n = 8; p = 0.02).ConclusionsEarly CTA can predict the future need for reintervention in patients with type II endoleak. Therefore, treatment decision should be based not only on aneurysm enlargement alone but also on other imaging characteristics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Amplatzer Vascular Plugs Versus Coils for Embolization of Pulmonary Arteriovenous Malformations in Patients with Hereditary Hemorrhagic Telangiectasia

PurposeCoil embolization of pulmonary arteriovenous malformations (PAVMs) has a high re-canalization/re-perfusion rate. Embolization with Amplatzer plugs has been previously described, but the long-term efficacy is not established. This study reports the experience of a referral medical center with the use of coils and Amplatzer plugs for treating PAVMs in patients with hereditary hemorrhagic telangiectasia.MethodsThe study was approved by the Institutional Review Board with waiver of informed consent. The cohort included all patients who underwent PAVM embolization in 2004–2014 for whom follow-up imaging scans were available. The medical files were retrospectively reviewed for background data, embolization method (coils, Amplatzer plugs, both), and complications. Re-canalization of treated PAVMs was assessed from intrapulmonary angiograms (following percutaneous procedures) or computed tomography angiograms. Fisher’s exact test and Pearson Chi-squared test or t test were used for statistical analysis, with significance at p < 0.05.Results16 patients met the study criteria. Imaging scans were available for 63 of the total 110 PAVMs treated in 41 procedures. Coils were used for embolization in 37 PAVMs, Amplatzer plugs in 21, and both in five. Median follow-up time was 7.7 years (range 1.4–18.9). Re-canalization was detected in seven vessels, all treated with coils; there were no cases of re-canalization in plug-occluded vessels (p = 0.0413).ConclusionThe use of Amplatzer plugs for the embolization of PAVMs in patients with hemorrhagic telangiectasia is associated with a significantly lower rate of re-canalization of feeding vessels than coils. Long-term prospective studies are required to confirm these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiple Renal Artery Pseudoaneurysms in Patients Undergoing Renal Artery Embolization Following Partial Nephrectomy: Correlation with RENAL Nephrometry Scores

PurposeTo describe the incidence of multiple renal artery pseudoaneurysms (PSA) in patients referred for renal artery embolization following partial nephrectomy and to study its relationship to RENAL nephrometry scores.Materials and MethodsThe medical records of 25 patients referred for renal artery embolization after partial nephrectomy were retrospectively reviewed for the following parameters: size and number of tumors, RENAL nephrometry scores, angiographic abnormalities, technical and clinical outcomes, and estimated glomerular filtration rates (eGFRs) after embolization.ResultsTwenty-four patients had primary renal tumors, while 1 patient had a pancreatic tumor invading the kidney. Multiple tumors were resected in 4 patients. Most patients (92 %) were symptomatic, presenting with gross hematuria, flank pain, or both. Angiography revealed PSA with (n = 5) or without (n = 20) AV fistulae. Sixteen patients (64 %) had multiple PSA involving multiple renal vessels. Higher RENAL nephrometry scores were associated with an increasing likelihood of multiple PSA. Multiple vessels were embolized in 14 patients (56 %). Clinical success was achieved after one (n = 22) or two (n = 3) embolization sessions in all patients. Post-embolization eGFR values at different time points after embolization were not significantly different from the post-operative eGFR.ConclusionA majority of patients requiring renal artery embolization following partial nephrectomy have multiple pseudoaneurysms, often requiring selective embolization of multiple vessels. Higher RENAL nephrometry score is associated with an increasing likelihood of multiple pseudoaneurysms. We found transarterial embolization to be a safe and effective treatment option with no long-term adverse effect on renal function in all but one patient with a solitary kidney.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Introducing the New 3.5/28 Microstent Retriever for Recanalization of Distal Cerebral Arteries in Acute Stroke: Preliminary Results

Background and Purpose: To describe our first experience using a small stent retriever specifically designed for thrombectomy in cerebral arteries with a small caliber (Acandis APERIO{sup ®} 3.5/28) in patients with acute ischemic stroke. Materials and Methods: All patients with an acute ischemic stroke, who underwent endovascular recanalization using the APERIO{sup ®} thrombectomy device with a diameter of 3.5 mm, were identified in retrospect and included in the present analysis. Demographic and clinical data as well as data on the procedures performed were collected (patient sex, mean age, NIHSS, mRS, TICI score, and complications). Results: Stent retriever-based thrombectomy with the Aperio{sup ®} 3.5/28 alone (n = 10 vessels) or in combination with other devices (n = 13 vessels) was performed in 22 acute stroke patients with embolic occlusions of distal branches of the anterior and posterior circulations (median NIHSS = 8.5). For vessels treated with the Aperio{sup ®} 3.5/28, we achieved a TICI 2b/3 reperfusion rate of 73.9%. One patient suffered a symptomatic intracerebral hemorrhage after thrombectomy; otherwise, no procedure-related complications were seen. Conclusion: Our data suggest that mechanical thrombectomy of distal cerebral artery occlusions with the Aperio{sup ®} 3.5/28 is feasible and in general safe, thus offering a promising option for endovascular stroke therapy. However, multicentric studies with larger patient cohorts are necessary to evaluate the clinical benefit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Evaluation of Percutaneous Groin Access for EVAR

Background: Percutaneous endovascular aneurysm repair (PEVAR) has been shown to have high success rates, shorter operating times and length of stay compared to open access. However, there exists a lack of long-term follow-up data on these patients, and questions remain regarding longer-term outcomes. This study aims to assess the long-term complications and evolution of accessed vessels post-PEVAR. Methods: Sixty-one cases of bilateral PEVAR (122 groins) with > 36 months follow-up were analysed. Vessel diameter, calcification, dissection, lymphocele, pseudoaneurysm and thrombus formation were reviewed at 30th day and at the most recent follow-up CT. Notes were reviewed for groin infections, haematomas and nerve injury. Complications were considered ‘major’ if they required intervention or treatment. Results: Mean follow-up time from procedure to most recent scan was 49.9 months. There were no major short- or long-term complications. The early complication rate was 9.8%, with six pseudoaneurysms, four dissections, one thrombus, one nerve injury and no lymphoceles, haematomas or groin infections. The long-term complication rate was 0.8%, with only one pseudoaneurysm. The remainder of early complications resolved naturally without intervention. Accessed vessel showed significantly (P ≤ 0.05) increased diameter and calcification between 30th day and last follow-up scan. Conclusion: This study provides the largest clinical cohort and the longest mean follow-up time reported in the literature and demonstrates the long-term safety of PEVAR. PEVAR has a very low long-term complication rate, without any major complications in our cohort. The accessed common femoral arteries do not show stenosis or thrombosis. Minor short-term complications appear to gradually resolve without intervention. Larger multi-centre studies are recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase II Trial of Transarterial Embolization Using an n-Butyl-2-Cyanoacrylate/Lipiodol Mixture (JIVROSG-0802)

Purpose: To evaluate the embolic effect and the safety of transarterial embolization (TAE) using n-butyl-2-cyanoacrylate (NBCA) in a prospective multicenter trial. Materials and Methods: This study was an open-label, multicenter, phase II trial. The inclusion criteria were (1) active bleeding or pseudoaneurysm, (2) true aneurysm, (3) arteriovenous malformation (except cerebral lesion), (4) arteriovenous fistula, or (5) need for arterial distribution before transarterial treatment. Selective TAE with NBCA diluted 2–10 times was performed. The primary endpoint was the success rate of embolization with a per-patient analysis based on the angiographic findings. Secondary endpoints were safety, evaluated based on Common Terminology Criteria for Adverse Events (CTCAE) version 4, and the success rate of embolization with a per-vessel calculation. Results: Sixty-five patients were initially enrolled, but due to protocol violation in two patients, efficacy was ultimately analyzed in 63 patients (103 vessels) and safety was analyzed in 64 patients. The success rate per patient was 98.4% (62/63; 95% confidence interval (CI), 91.5–100.00), and the success rate per vessel was 99.0% (102/103; 95% CI, 94.7–100.0). Adverse events of grade 3 or above based on CTCAE version 4 occurred in 22/64 patients (34.4%). Twelve intraoperative or postoperative adverse events grade 3 or above, which may have been related to embolization using NBCA, occurred in 11/64 patients (17.2%). Three patients died after embolization using NBCA, but their deaths were unrelated to TAE. Conclusion: In this prospective multicenter clinical trial, the efficacy of TAE using NBCA was 98.4% and adverse events were clinically acceptable. Level of Evidence: Level 3b.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Very Unlucky Intraoperative Event During a Chimney Technique for Juxtarenal Aneurysm Exclusion

A two-vessel Ch-EVAR procedure was scheduled within the instructions for use of the devices. After deploying, it appeared that the long sheath inserted through an arm access was discovered to be trapped behind the aortic stentgraft barbs. Trying to remove the sheath, the graft was displaced upward and the procedure was converted for a three-vessel Ch-EVAR incorporating the superior mesenteric artery. Simultaneous ballooning of the target vessels and the stentgraft permitted to exert a strong pullback traction on the blocked sheath, allowing its removal. A segment of the sheath distal end was left trapped in the aortic stentgraft. At 12 months follow-up, the patient is free of any complications and there are no occlusions of the abdominal visceral branches or embolic events in peripheral arteries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Incidence and Consequence of Nontarget Embolization Following Bland Hepatic Arterial Embolization

Purpose: Estimate the incidence of nontarget embolization (NTE) as identified on immediate post-hepatic artery embolization CT. Materials and Methods: Two hundred hepatic embolizations performed with particles alone (bland embolization) in 147 patients between August 16, 2013 and August 26, 2014 with immediate post-procedure CT were retrospectively reviewed. Arterial anatomy, vessels treated, imaging findings of NTE, patient demographics, length of hospital stay following embolization, and procedure-related complications were recorded. The data were analyzed using two-sided t-tests and chi-squared tests. Results: Evidence of NTE was seen on post-procedure CT in 64 of 200 cases (64/200, 32%). Six organs were affected, with 69 discrete sites in 64 patients. The majority (49/69, 71.0%) involved the gallbladder. The mean length of hospital stay (LOS) for patients with and without NTE was 2.9 ± 1.5 nights (range 1–7) and 2.9 ± 2.3 nights (range 0–21), respectively (P = 0.81). NTE was more common following embolization of replaced or accessory hepatic vessels. There were three complications in the NTE group (3/64, 4.7%) following the embolization procedure, one of which was cholecystitis directly related to NTE. The other two were one incidence each of contrast-induced nephropathy and pneumonia. In the group without NTE, seven complications occurred (7/136, 5.1%, P = 0.889), including one death resulting from hepatic failure, two gastrointestinal bleeds, two hepatic abscesses, flash pulmonary edema, and pancreatitis. Conclusion: Unanticipated NTE is not uncommon after bland hepatic artery embolization, particularly after treating accessory or replaced vessels, but does not increase complications or LOS. Level of Evidence: Level 2b, Retrospective Cohort.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Increasing the Efficiency of Forming Coatings on the Working Rotor Blades of Steam Turbines{sup 1}

The article is devoted to an analysis of the characteristics of the KGB-5M electric-spark plant developed by the authors for use in the formation of erosion- and abrasion-resistant protective-reinforcing coatings on the leading and trailing edges of the rotor blades of the steam turbines of thermal and atomic power stations. It is shown that an increase in the thickness of electric-spark coatings and the efficiency of the plant may be produced by decreasing the “stray” inductance of the external discharge circuit and through rational selection of new wear- and erosion-resistant synthetic materials. The results of metallographic investigations of coatings produced by the KGB-5M plant are presented. The KGB-5 plant, which consists of a low-voltage vessel and a high-voltage vessel, was developed to achieve electric safety in the formation of coatings in closed metallic vessels (for example, in the capacitor of a turbine).

36 MATERIALS SCIENCE↗

Endovascular Thrombectomy for Acute Ischemic Stroke

Purpose of Review: To review the current evidence supporting the use of endovascular thrombectomy (EVT) for the treatment of acute ischemic stroke (AIS) due to anterior circulation large vessel occlusion (LVO). Recent Findings: Recent advances in AIS management by EVT have led to significant reduction in morbidity and mortality in selected patients with LVO within the anterior circulation. Until recently, use of EVT was strictly based on time criteria, within 4.5 to 12 h of symptom onset with many patients presenting with “wake-up” stroke who were not considered for EVT. The positive results of the DAWN and DEFUSE-3 trials have shown benefit in extending the therapeutic window for EVT to 24 and 16 h, respectively, after last known normal (LKN) time in the setting of large ischemic penumbra. These trials represent a paradigm shift in contemporary treatment of AIS, changing from a purely time-based decision to treat to an individualized decision based on clinical and radiographic findings of salvageable tissue. Summary: Overall, acute stroke management has evolved considerably over the years from intravenous thrombolysis to include EVT, with paralleled improvements in patient selection and thrombectomy devices. Since the results of the DAWN and DEFUSE-3, EVT is now considered the standard of care in select patients with anterior circulation LVO up to 24 h from LKN time. Despite these developments, post-stroke disability remains pervasive and further studies are warranted in establishing the role of EVT in posterior circulation and distal vessel occlusions, with need for development of new and effective techniques for revascularization of small vessels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Self-powered Through-wall communication for dry cask storage monitoring

Many nuclear facilities, such as spent fuel storage dry casks and nuclear reactor pressure vessels, are entirely sealed by metal layers to prevent harmful radiation. For safety and security operations, the temperature, pressure, radiation, and humidity inside the vessel needs to be closely monitored. However, no practical technology is currently available to realize the through-wall data communication and monitoring for these vessels due to the inside harsh environment of high temperature and nuclear radiation. In this paper, an innovative self-powered wireless through-wall data communication system for the nuclear environment is presented, which demonstrates a successful solution to such challenges. The presented system is composed of four modules, i.e., energy harvester with power management circuits, ultrasound wireless communication using high-temperature piezoelectric transducers, electronic circuits for sensing and data transmission, and radiation shielding for electronics. Here, constitutive functions of each module were firstly designed and followed by the system integration. Experiments were conducted subsequently to validate the designed functions and evaluate the performance of the integrated system. Results showed that the average power of over 40 mW was harvested from the thermal flow inside the nuclear spent fuel canisters which could provide enough energy to operate the sensing and data communication systems. The gamma radiation test results showed that the thermoelectric energy harvester and ultrasound transceivers can withstand radiation dosing over 100 Mrad. Furthermore, temperature shock tests demonstrated that the entire system including the shielded electronics can survive and maintain their functionalities at temperatures as high as 195°C. Under the in-lab mocked-up high temperature conditions and radiation shielding, the proposed system is foreseen to survive and operate stably for fifty years inside a nuclear spent fuel canister, and send the frequency modulated data out of the canister for 3 s in every 10 min.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Inhibition of Notch signaling by Dll4-Fc promotes reperfusion of acutely ischemic tissues

Highlights: Black-Right-Pointing-Pointer Low dose Dll4-Fc increases vascular proliferation and overall perfusion. Black-Right-Pointing-Pointer Low dose Dll4-Fc helps vascular injury recovery in hindlimb ischemia model. Black-Right-Pointing-Pointer Low dose Dll4-Fc helps vascular injury recovery in skin flap model. Black-Right-Pointing-Pointer Dll4 heterozygous deletion promotes vascular injury recovery. Black-Right-Pointing-Pointer Dll4 overexpression delays vascular injury recovery. -- Abstract: Notch pathway regulates vessel development and maturation. Dll4, a high-affinity ligand for Notch, is expressed predominantly in the arterial endothelium and is induced by hypoxia among other factors. Inhibition of Dll4 has paradoxical effects of reducing the maturation and perfusion in newly forming vessels while increasing the density of vessels. We hypothesized that partial and/or intermittent inhibition of Dll4 may lead to increased vascular response and still allow vascular maturation to occur. Thus tissue perfusion can be restored rapidly, allowing quicker recovery from ischemia or tissue injury. Our studies in two different models (hindlimb ischemia and skin flap) show that inhibition of Dll4 at low dose allows faster recovery from vascular and tissue injury. This opens a new possibility for Dll4 blockade's therapeutic application in promoting recovery from vascular injury and restoring blood supply to ischemic tissues.

60 APPLIED LIFE SCIENCES↗

Evaluation of the in vitro and in vivo angiogenic effects of exendin-4

Highlights: •We investigated the effects of exendin-4 on the angiogenic process. •Exendin-4 increased migration, sprouting, and tube formation by HUVECs in in vitro. •Exendin-4 increased sprouts in aortic rings and induced new vessels in Matrigel in in vivo. •Exendin-4 may be of potential use for the treatment of vascular complications of diabetes. -- Abstract: Exendin-4, an analog of glucagon-like peptide (GLP)-1, has beneficial effects on cardiovascular disease induced by diabetes mellitus (DM). Recently, exendin-4 was reported to induce the proliferation of endothelial cells. However, its angiogenic effect on endothelial cells has not been clearly evaluated. Therefore, we investigated the effects of exendin-4 on the angiogenic process with respect to migration, sprouting, and neovascularization using in vitro and in vivo assays. Treatment with exendin-4 increased the migration of human umbilical vein endothelial cells (HUVECs) in in vitro scratch wound assays, as well as the number of lumenized vessels sprouting from HUVECs in in vitro 3D bead assays. These responses were abolished by co-treatment with exendin (9–39), a GLP-1 receptor antagonist, which suggests that exendin-4 regulates endothelial cell migration and tube formation in a GLP-1 receptor-dependent manner. In an ex vivo assay, treatment of aortic rings with exendin-4 increased the sprouting of endothelial cells. Exendin-4 also significantly increased the number of new vessels and induced blood flow in Matrigel plugs in in vivo assays. Our results provide clear evidence for the angiogenic effect of exendin-4 in in vitro and in vivo assays and provide a mechanism underlying the cardioprotective effects of exendin-4.

60 APPLIED LIFE SCIENCES↗