Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Hippocampal-Sparing Whole-Brain Radiotherapy: A 'How-To' Technique Using Helical Tomotherapy and Linear Accelerator-Based Intensity-Modulated Radiotherapy

Purpose: Sparing the hippocampus during cranial irradiation poses important technical challenges with respect to contouring and treatment planning. Herein we report our preliminary experience with whole-brain radiotherapy using hippocampal sparing for patients with brain metastases. Methods and Materials: Five anonymous patients previously treated with whole-brain radiotherapy with hippocampal sparing were reviewed. The hippocampus was contoured, and hippocampal avoidance regions were created using a 5-mm volumetric expansion around the hippocampus. Helical tomotherapy and linear accelerator (LINAC)-based intensity-modulated radiotherapy (IMRT) treatment plans were generated for a prescription dose of 30 Gy in 10 fractions. Results: On average, the hippocampal avoidance volume was 3.3 cm{sup 3}, occupying 2.1% of the whole-brain planned target volume. Helical tomotherapy spared the hippocampus, with a median dose of 5.5 Gy and maximum dose of 12.8 Gy. LINAC-based IMRT spared the hippocampus, with a median dose of 7.8 Gy and maximum dose of 15.3 Gy. On a per-fraction basis, mean dose to the hippocampus (normalized to 2-Gy fractions) was reduced by 87% to 0.49 Gy{sub 2} using helical tomotherapy and by 81% to 0.73 Gy{sub 2} using LINAC-based IMRT. Target coverage and homogeneity was acceptable with both IMRT modalities, with differences largely attributed to more rapid dose fall-off with helical tomotherapy. Conclusion: Modern IMRT techniques allow for sparing of the hippocampus with acceptable target coverage and homogeneity. Based on compelling preclinical evidence, a Phase II cooperative group trial has been developed to test the postulated neurocognitive benefit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiological and Clinical Pneumonitis After Stereotactic Lung Radiotherapy: A Matched Analysis of Three-Dimensional Conformal and Volumetric-modulated Arc Therapy Techniques

Purpose: Lung fibrosis is common after stereotactic body radiotherapy (SBRT) for lung tumors, but the influence of treatment technique on rates of clinical and radiological pneumonitis is not well described. After implementing volumetric modulated arc therapy (RapidArc [RA]; Varian Medical Systems, Palo Alto, CA) for SBRT, we scored the early pulmonary changes seen with arc and conventional three-dimensional SBRT (3D-CRT). Methods and Materials: Twenty-five SBRT patients treated with RA were matched 1:2 with 50 SBRT patients treated with 3D-CRT. Dose fractionations were based on a risk-adapted strategy. Clinical pneumonitis was scored using Common Terminology Criteria for Adverse Events version 3.0. Acute radiological changes 3 months posttreatment were scored by three blinded observers. Relationships among treatment type, baseline factors, and outcomes were assessed using Spearman's correlation, Cochran-Mantel-Haenszel tests, and logistic regression. Results: The RA and 3D-CRT groups were well matched. Forty-three patients (57%) had radiological pneumonitis 3 months after treatment. Twenty-eight patients (37%) had computed tomography (CT) findings of patchy or diffuse consolidation, and 15 patients (20%) had ground-glass opacities only. Clinical pneumonitis was uncommon, and no differences were seen between 3D-CRT vs. RA patients in rates of grade 2/3 clinical pneumonitis (6% vs. 4%, respectively; p = 0.99), moderate/severe radiological changes (24% vs. 36%, respectively, p = 0.28), or patterns of CT changes (p = 0.47). Radiological severity scores were associated with larger planning target volumes (p = 0.09) and extended fractionation (p = 0.03). Conclusions: Radiological changes after lung SBRT are common with both approaches, but no differences in early clinical or radiological findings were observed after RA. Longer follow-up will be required to exclude late changes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Positional Reproducibility of Pancreatic Tumors Under End-Exhalation Breath-Hold Conditions Using a Visual Feedback Technique

Purpose: To assess positional reproducibility of pancreatic tumors under end-exhalation (EE) breath-hold (BH) conditions with a visual feedback technique based on computed tomography (CT) images. Methods and Materials: Ten patients with pancreatic cancer were enrolled in an institutional review board-approved trial. All patients were placed in a supine position on an individualized vacuum pillow with both arms raised. At the time of CT scan, they held their breath at EE with the aid of video goggles displaying their abdominal displacement. Each three-consecutive helical CT data set was acquired four times (sessions 1-4; session 1 corresponded to the time of CT simulation). The point of interest within or in proximity to a gross tumor volume was defined based on certain structural features. The positional variations in point of interest and margin size required to cover positional variations were assessed. Results: The means {+-} standard deviations (SDs) of intrafraction positional variations were 0.0 {+-} 1.1, 0.1 {+-} 1.2, and 0.1 {+-} 1.0 mm in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions, respectively (p = 0.726). The means {+-} SDs of interfraction positional variations were 0.3 {+-} 2.0, 0.8 {+-} 1.8, and 0.3 {+-} 1.8 mm in the LR, AP, and SI directions, respectively (p = 0.533). Population-based margin sizes required to cover 95th percentiles of the overall positional variations were 4.7, 5.3, and 4.9 mm in the LR, AP, and SI directions, respectively. Conclusions: A margin size of 5 mm was needed to cover the 95th percentiles of the overall positional variations under EE-BH conditions, using this noninvasive approach to motion management for pancreatic tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Assurance of 4D-CT Scan Techniques in Multicenter Phase III Trial of Surgery Versus Stereotactic Radiotherapy (Radiosurgery or Surgery for Operable Early Stage (Stage 1A) Non-Small-Cell Lung Cancer [ROSEL] Study)

Purpose: To determine the accuracy of four-dimensional computed tomography (4D-CT) scanning techniques in institutions participating in a Phase III trial of surgery vs. stereotactic radiotherapy (SBRT) for lung cancer. Methods and Materials: All 9 centers performed a 4D-CT scan of a motion phantom (Quasar, Modus Medical Devices) in accordance with their in-house imaging protocol for SBRT. A cylindrical cedar wood insert with plastic spheres of 15 mm (o15) and 30 mm (o30) diameter was moved in a cosine-based pattern, with an extended period in the exhale position to mimic the actual breathing motion. A range of motion of R = 15 and R = 25 mm and breathing period of T = 3 and T = 6 s were used. Positional and volumetric imaging accuracy was analyzed using Pinnacle version 8.1x at various breathing phases, including the mid-ventilation phase and maximal intensity projections of the spheres. Results: Imaging using eight CT scanners (Philips, Siemens, GE) and one positron emission tomography-CT scanner (Institution 3, Siemens) was investigated. The imaging protocols varied widely among the institutions. No strong correlation was found between the specific scan protocol parameters and the observed results. Deviations in the maximal intensity projection volumes averaged 1.9% (starting phase of the breathing cycle [o]15, R = 15), 12.3% (o15, R = 25), and -0.9% (o30, R = 15). The end-expiration volume deviations (13.4%, o15 and 2.5%, o30), were, on average, smaller than the end-inspiration deviations (20.7%, o15 and 4.5%, o30), which, in turn, were smaller than the mid-ventilation deviations (32.6%, o15 and 8.0%, o30). A slightly larger variation in the mid-ventilation origin position was observed (mean, -0.2 mm; range, -3.6-4.2) than in the maximal intensity projection origin position (mean, -0.1 mm; range, -2.5-2.5). The range of motion was generally underestimated (mean, -1.5 mm; range, -5.5-1). Conclusions: Notable differences were seen in the 4D-CT imaging protocols for SBRT among centers. However, the observed deviations in target volumes were generally small. They were slightly larger for the mid-ventilation phases and smallest for the end-expiration phases. Steps to optimize and standardize the 4D-CT scanning protocols for SBRT are desirable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Breast Cancer-Related Arm Lymphedema: Incidence Rates, Diagnostic Techniques, Optimal Management and Risk Reduction Strategies

As more women survive breast cancer, long-term toxicities affecting their quality of life, such as lymphedema (LE) of the arm, gain importance. Although numerous studies have attempted to determine incidence rates, identify optimal diagnostic tests, enumerate efficacious treatment strategies and outline risk reduction guidelines for breast cancer-related lymphedema (BCRL), few groups have consistently agreed on any of these issues. As a result, standardized recommendations are still lacking. This review will summarize the latest data addressing all of these concerns in order to provide patients and health care providers with optimal, contemporary recommendations. Published incidence rates for BCRL vary substantially with a range of 2-65% based on surgical technique, axillary sampling method, radiation therapy fields treated, and the use of chemotherapy. Newer clinical assessment tools can potentially identify BCRL in patients with subclinical disease with prospective data suggesting that early diagnosis and management with noninvasive therapy can lead to excellent outcomes. Multiple therapies exist with treatments defined by the severity of BCRL present. Currently, the standard of care for BCRL in patients with significant LE is complex decongestive physiotherapy (CDP). Contemporary data also suggest that a multidisciplinary approach to the management of BCRL should begin prior to definitive treatment for breast cancer employing patient-specific surgical, radiation therapy, and chemotherapy paradigms that limit risks. Further, prospective clinical assessments before and after treatment should be employed to diagnose subclinical disease. In those patients who require aggressive locoregional management, prophylactic therapies and the use of CDP can help reduce the long-term sequelae of BCRL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long coir and glass fiber reinforced polypropylene hybrid composites prepared via wet-laid technique

Natural fiber composites offer an advantage in terms of weight saving for many automotive applications; however, many natural fiber composites lack properties to justify substitution for synthetic composites. Hybridizing the natural fiber composites by adding a fraction of synthetic fibers is an innovative approach to provide a balance between composite's performance and weight savings. In this study, coir fiber (40 wt%)-reinforced polypropylene (PP) composites were hybridized by substituting a fraction of coir fiber with glass fiber (0–30 wt%). The composites were prepared using a novel wet-laid technique followed by compression molding, where the fiber length is preserved. The composites prepared by hybridizing PP/coir fibers with glass fibers were light in weight (6–20% lighter compared to 40 wt% glass fiber reinforced PP) with significantly enhanced tensile (strength – 49–182%, modulus – 54–130%), flexural (strength – 41–104%, modulus – 64–193%), and impact properties (157 - 474%) compared to 40 wt% coir fiber reinforced PP composites. Furthermore, the addition of glass fiber (10–30 wt%) to coir fiber reduced the water-absorbing tendency (by 18–74%) of PP/coir fiber composites. All in all, this work has potential applications in automotive, mass transit, and truck applications where natural fiber composites are being investigated as alternatives to metal and/or fully synthetic composites.

36 MATERIALS SCIENCE↗

Novel techniques for constraining neutron-capture rates relevant for r -process heavy-element nucleosynthesis

The rapid-neutron capture process (r process) is identified as the producer of about 50% of elements heavier than iron. This process requires an astrophysical environment with an extremely high neutron flux over a short amount of time ( seconds), creating very neutron-rich nuclei that are subsequently transformed to stable nuclei via beta decay. In 2017, one site for the r process was confiimed: the advanced LIGO and advanced Virgo detectors observed two neutron stars merging, and immediate follow-up measurements of the electromagnetic transients demonstrated an "afterglow" over a broad range of frequencies fully consistent with the expected signal of an r process taking place. Although neutronstar mergers are now known to be r-process element factories, contributions from other sites are still possible, and a comprehensive understanding and description of the r process is still lacking. One key ingredient to large-scale r-process reaction networks is radiative neutron-capture ( n , γ ) rates, for which there exist virtually no data for extremely neutron rich nuclei involved in the r process. Due to the current status of nuclear-reaction theory and our poor understanding of basic nuclear properties such as level densities and average g-decay strengths, theoretically estimated ( n , γ ) rates may vary by orders of magnitude and represent a major source of uncertainty in any nuclear-reaction network calculation of r-process abundances. Here in this review, we discuss new approaches to provide information on neutron-capture cross sections and reaction rates relevant to the r process. In particular, we focus on indirect, experimental techniques to measure radiative neutron-capture rates. While direct measurements are not available at present, but could possibly be realized in the future, the indirect approaches present a first step towards constraining neutron-capture rates of importance to the r process.

(n, γ,) cross sections↗

Cu-Ga-Se Thin Films Prepared by a Combination of Electrodeposition and Evaporation Techniques

Cu-Ga-Se thin films were prepared using a combination of electrodeposition and evaporation techniques. A Cu-Se/Mo/glass precursor thin film was first prepared by galvanostatic electrodeposition. On top of this film three different thicknesses of Ga were deposited by evaporation. The Cu-Ga-Se thin films were formed by annealing the Ga/Cu-Se/Mo/glass thin film configuration in a tubular chamber with Se powder, at different temperatures. Thin films were characterized by X-ray diffraction (XRD), photocurrent spectroscopy (PS), inductively coupled plasma (ICP) analysis, and scanning electron microscopy (SEM). The detailed analysis from X-ray reveals that after annealing at 550 C the CuGaSe{sub 2} phase is formed when the thickness of Ga is 0.25 {mu}m, however at 0.5 {mu}m and 1.0 {mu}m Ga the formation of CuGa{sub 3}Se{sub 5} and CuGa{sub 5}Se{sub 8} phases is observed respectively. Band gap values were obtained using photocurrent spectroscopy.

14 SOLAR ENERGY↗

X-ray-Based Techniques to Study the Nano–Bio Interface

X-ray-based analytics are routinely applied in many fields, including physics, chemistry, materials science, and engineering. The full potential of such techniques in the life sciences and medicine, however, has not yet been fully exploited. We highlight current and upcoming advances in this direction. We describe different X-ray-based methodologies (including those performed at synchrotron light sources and X-ray free-electron lasers) and their potentials for application to investigate the nano–bio interface. The discussion is predominantly guided by asking how such methods could better help to understand and to improve nanoparticle-based drug delivery, though the concepts also apply to nano–bio interactions in general. We discuss current limitations and how they might be overcome, particularly for future use in vivo.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A quantitative comparison of the fingerprint of twinned microstructures through surface and three-dimensional techniques

Assessing the fingerprint of a material’s microstructure is key for supporting materials design. With the emergence of a wide range of 3D characterization techniques, it is critical to understand the main differences in fingerprints reconstructed from 2D and 3D datasets. To this end, we introduce a graph-based microstructure reconstruction framework that enables structural comparisons of twin domain networks in high purity Ti using 3D and 2D electron backscatter diffraction. Insights into the structure of the twin networks are facilitated by combining statistical analysis of twin crystallography with visual and graphical analysis of the novel graph abstractions of the twins. We demonstrate that compared to 3D reconstructions, conventional 2D views of twinning miss key aspects of the microstructure including the high interconnectivity of domains into networks that span the full reconstruction volume. The reduced cross-grain and in-grain twin connectivity typically observed in 2D has notable implications on our understanding of how twinning mediates the plastic response of microstructures and how twin networks evolve. It is thus clear that 3D characterization is critical for accurately inferring both twin network morphologies as well as the key unit processes facilitating network formation.

36 MATERIALS SCIENCE↗

Status On Multi-microsecond Prepulse Technique On Sphinx Machine Going From Nested To Single Wire Array For 800 ns Implosion Time Z-pinch

The Sphinx machine{sup [1]} is a 6 MA, 1 {mu}S driver based on the LTD technology, used for Z-pinch experiments. Important improvements of Sphinx radiation output were recently obtained using a multi-microsecond current prepulse{sup [2]}. Total power per unit of length is multiplied by a factor of 6 and FWHM divided by a factor of 2.5. Early breakdown of the wires during the prepulse phase dramatically changes the ablation phase leading to an improvement of axial homogeneity of both the implosion and the final radiating column. As a consequence, the cathode bubble observed on classical shots is definitively removed. The implosion is then centered and zippering effect is reduced, leading to simultaneous x-ray emission of the whole length. A great reproducibility is obtained. Nested arrays were used before to mitigate the Rayleigh-Taylor instabilities during the implosion phase. Further experiments with pre-pulse technique are described here were inner array was removed. The goal of these experiments was to see if long prepulse could give stable enough implosion with single array and at the same time increase the {eta} parameter by reducing the mass of the load. Experimental results of single wire array loads of typical dimension 5 cm in height with implosion time between 700 and 900 ns and diameter varying between 80 and 140 mm are given. Parameters of the loads were varying in term of radius and number of wires. Comparisons with nested wire array loads are done and trends are proposed. Characteristics of both the implosion and the final radiating column are shown. 2D MHD numerical simulations of single wire array become easier as there is no interaction between outer and inner array anymore. A systematic study was done using injection mass model to benchmark simulation with experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear and Related Analytical Techniques for Environmental and Life Sciences

The role of nuclear analytical techniques (NATs) in Environmental and Life Sciences is discussed. Examples of radioanalytical investigations at the IBR-2 pulsed fast reactor in Dubna illustrate the environmental, biomedical, geochemical and industrial applications of instrumental neutron activation analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new technique for X-ray spectroscopy of laser-plasmas with simultaneous 2D spatial resolution over a broad spectral range

Over the past few years, a new X-ray diagnostic technique has been developed by the group of the Intense Laser Irradiation Laboratory of the CNR in Pisa. Here we give a brief description of this new diagnostic tool, which basically allows X-ray spectroscopy of laser-produced plasmas to be performed over a broad photon energy range with a simultaneous 2D spatial resolution. An outline of recent results will be also given in order to assess the diagnostic capabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photon counting technique applied to time-resolved laser-induced fluorescence measurements on a stabilized discharge

A novel approach to perform time-resolved laser-induced fluorescence (LIF) measurements in plasma discharges is presented. The LIF technique relies on a photon counting method associated with a sinusoidal potential modulation on a floating electrode located in the plasma to ensure time coherence. By tuning the modulation frequency, resonance can be reached with the discharge current in order to guarantee repeatable measurement conditions. Time-averaged characteristics of the discharge (such as T{sub e}, n{sub e}, V{sub p}, and V{sub ion}) remain unaffected by the modulation. As an example, the association of the photon counting method with the modulation system is employed to determine the time evolution of several ion velocity groups inside an E × B discharge. Interesting features of the velocity oscillations are examined and pave the way for more focused studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the gas puff charge exchange recombination spectroscopy (GP-CXRS) technique for ion measurements in the plasma edge

A novel charge-exchange recombination spectroscopy (CXRS) diagnostic method is presented, which uses a simple thermal gas puff for its donor neutral source, instead of the typical high-energy neutral beam. This diagnostic, named gas puff CXRS (GP-CXRS), is used to measure ion density, velocity, and temperature in the tokamak edge/pedestal region with excellent signal-background ratios, and has a number of advantages to conventional beam-based CXRS systems. Here we develop the physics basis for GP-CXRS, including the neutral transport, the charge-exchange process at low energies, and effects of energy-dependent rate coefficients on the measurements. The GP-CXRS hardware setup is described on two separate tokamaks, Alcator C-Mod and ASDEX Upgrade. Measured spectra and profiles are also presented. Profile comparisons of GP-CXRS and a beam based CXRS system show good agreement. Emphasis is given throughout to describing guiding principles for users interested in applying the GP-CXRS diagnostic technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent Rayleigh-Brillouin scattering as a flow diagnostic technique

Broadband coherent Rayleigh-Brillouin scattering (CRBS) was used to measure translational gas temperatures for nitrogen at the ambient pressure of 0.8 atm using a purpose-built Fabry-Perot etalon spectrometer. Temperatures derived from the CRBS spectral analysis were compared with experimentally-measured temperatures, and were found to be, on average, within 2% of the experimentally-measured value. Axial flow velocities from a double jet at a pressure ratio of 0.38 were also measured by looking at the Doppler shift of the CRBS line shape. With recent developments in chirped laser technology and the capacity of CRBS to simultaneously provide thermodynamic and bulk flow information, the CRBS line shape acquisition and analysis technique presented here may allow for future time-resolved, characterization of aerospace flows.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Kinetic theory of particle-in-cell simulation plasma and the ensemble averaging technique

Abstract We derive the kinetic theory of fluctuations in physically and numerically stable particle-in-cell (PIC) simulations of electrostatic plasmas. The starting point is the single-time correlation at the start of the simulation between the statistical fluctuations of the weighted densities of macroparticle centers in the plasma particle phase-space. The fluctuations are associated with different initial conditions, typically due to the random initial conditions (in velocity space) of the macroparticles/simulation plasma, assigned according to their initial distribution of probability. The single-time correlations at all time steps and in each spatial grid cell are then determined from the Laplace–Fourier transforms of the discretized Klimontovich-like equation for the macroparticles and Maxwell’s equations for the fields, as computed by modern PIC codes. We recover the expressions for the electrostatic field and the plasma particle density fluctuation autocorrelation spectra as well as the kinetic equations describing the average evolution of PIC-simulated plasma particles, first derived by Langdon (1970b Proc. 4th Conf. Numerical Simulation of Plasmas ) using a test macroparticle approach perturbing a discretized Vlasovian plasma and then averaging the obtained physical quantity over the initial macroparticle velocity distribution. We generalize and extend these results to the modern algorithms in PIC codes using arbitrary macroparticle weights. Analytical estimates of statistical fluctuation amplitudes are derived as a function of the plasma simulation parameters, using the central limit theorem in the limit of a large number of macroparticles per cell. The theory is then used to analyze the ensemble averaging technique of PIC simulations where statistical averages are performed over ensembles of PIC simulations, modeling the same plasma physics problem but using different statistical realizations of the initial distribution functions of the macroparticles. This method is illustrated by linear Landau damping uncovering (from noise, which is usually considered numerical) the physical fluctuations driven by a single small amplitude electrostatic wave perturbing a PIC simulation plasma in equilibrium.

fluctuations correlations↗

Strongly adhesive dry transfer technique for van der Waals heterostructure

That one can stack van der Waals materials with atomically sharp interfaces has provided a new material platform of constructing heterostructures. The technical challenge of mechanical stacking is picking up the exfoliated atomically thin materials after mechanical exfoliation without chemical and mechanical degradation. Chemically inert hexagonal boron nitride (hBN) has been widely used for encapsulating and picking up vdW materials. However, due to the relatively weak adhesion of hBN, assembling vdW heterostructures based on hBN has been limited. Here, we report a new dry transfer technique. We used two vdW semiconductors (ZnPS 3 and CrPS 4 ) to pick up and encapsulate layers for vdW heterostructures, which otherwise are known to be hard to fabricate. By combining with optimized polycaprolactone (PCL) providing strong adhesion, we demonstrated various vertical heterostructure devices, including quasi-2D superconducting NbSe 2 Josephson junctions with atomically clean interface. The versatility of the PCL-based vdW stacking method provides a new route for assembling complex 2D vdW materials without interfacial degradation.

36 MATERIALS SCIENCE↗