Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Island Power Systems With High Levels of Inverter-Based Resources: Stability and Reliability Challenges

As many island power systems seek to integrate high levels of renewable energy, they face new challenges on top of the existing difficulties of operating an isolated grid. With their drastically declining cost, variable renewables, such as wind and photovoltaics (PVs), are increasingly being integrated into island grids to reduce the use of imported fuels. These deployments of renewable energy are dominated by PV and wind generators, which bring unique challenges of their own. While the integration issues span numerous timescales (from microseconds to many months), this article focuses on reliability and stability challenges on short timescales (microseconds to seconds). In other words, we seek to answer (to the extent that it is currently known) how to ensure the frequency and voltage stability in an island power system with very high instantaneous levels of wind and PVs. And because island power systems are often among the first to reach these very high instantaneous levels of wind and PV generation, we note that they are forging a path for larger interconnected power systems to follow.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Toward the Development of a High-Voltage Mg Cathode Using a Chromium Sulfide Host

Development of Mg-ion batteries as advanced electrochemical energy storage systems relies on the design and discovery of high-voltage positive electrode (cathode) materials. To date, a variety of sulfide cathodes have been reported (e.g., Mg x Mo 6 S 8 , Mg x Ti 2 S4, etc.), but the voltages of these materials are too low to prepare a high energy density Mg cell. Theoretical computations predicted that Mg x Cr 2 S 4 operating with the high-voltage Cr 3+/4+ redox couple would serve as a suitable cathode candidate, but experimental attempts to extract Mg 2+ from the lattice have been largely unsuccessful. Here, we show that reversible electrochemical activity within a thiospinel framework (AB 2 S 4 ) relies on a redox-active transition metal present in the B site; otherwise, anionic redox activity triggers decomposition of the spinel structure. Since Cr and S states are highly coupled in MgCr 2 S 4 , the Cr 3+/4+ redox couple is inaccessible so that reversible (de)intercalation of Mg 2+ cannot occur and charging leads to dissolution of the active material. These findings point to an insufficiency in the screening criteria previously used to identify MgCr 2 S 4 as a promising Mg cathode. Thus, a computable descriptor based on the electronic structure of the discharged material is proposed to predict the prevalence of cation vs anion redox and improve future surveys of potential candidates. It is unlikely that the high-voltage Cr redox couple will be accessible to oxidation in the presence of sulfur within the restrictions of a spinel framework; however, it is possible that a suitable layered Mg x CrS 2 structure could serve as a reversible high-voltage Mg cathode.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SMART SiC Power ICs: Scalable, Manufacturable, and Robust Technology for SiC Power Integrated Circuits (Final Technical Report)

This collaborative project was initiated with the goal of developing Scalable, Manufacturable, and Robust Technology for SiC Power Integrated Circuits (SMART SiC Power ICs). In pursuit of this objective, innovative designs and fabrication processes were implemented, enabling the development of large-scale (>1 cm²) SiC Complementary Metal-Oxide-Semiconductor (CMOS) integrated circuits and high-voltage (400–600 V) lateral power MOSFETs (HV-LDMOS) on 150 mm 4H-SiC substrates. The resulting SMART SiC Power ICs are tailored to support a wide range of applications requiring diverse voltage and power levels, including automotive systems, industrial equipment, electronic data processing, energy harvesting, and power conditioning. To achieve the proposed ‘SMART’ technology for SiC ICs, the team focused on 1) the Development of highly scalable CMOS (with high channel mobilities for n-type and p-type MOSFETs), LDMOS (~600V, 10A rated), and IC technologies, 2) Establishment of a manufacturable process baseline in a production-grade-, 150mm, SiC fabrication facility, and 3) Demonstration of SMART SiC ICs. The project initially comprised of fabricating 5 lots. In lot 1 monolithic integration using a single process was achieved. Here, we were able to successfully accomplish Integrated HV NMOSFET with LV CMOS on N-epi/N+ Substrate. The HV NMOS demonstrated a Breakdown Voltage (BV) more than 600V. Circuit demonstration of CMOS was also another achievement from this lot. In lot 2, priority was in place for isolation and integration. Here we addressed the isolation concerns and integrated the HV NMOS and LV CMOS using the N-epi/P-epi/N+ substrate. Similar to the lot 1, we were able to achieve a BV of 600 V for HV NMOS. Optimized gate oxide process with high channel mobilities, better gate oxide reliability, development of SPICE models, successful ohmic process development, novel wafer area saving design layouts, P+ isolation schemes with channeling implantations and high temperature operational circuits demonstrations are some of the key highlights from lot 1 and lot2. In lot 3, discrete device performances of HV NMOS with a BV ~700V and reliable LV CMOS performances were achieved. Also, novel architectural solutions were successfully implemented to suppress the electric field crowding at the gate oxide for reliable operations. In lot 4, half bridge power driver ICs with a conversion efficiency of (target 90% to 95%) in the 1-5MHz switching frequency range for output power between 25 W to 3 kW have been included in. However, due to the unfortunate events of sudden foundry shutdown (SiCamore Semi) the processing of lot 4 wafers came to a complete stop (January 2024). Arrangements have recently been made to shift the fabrication to another foundry, General Electric Aerospace. The fabrication process now on course (as of December 2024). Characterizations are delayed due to this unfortunate circumstance. The proposed trench architectural-based devices and ICs (lot 5) underwent modifications from the original project proposal. This change was necessitated by limitations in the availability of trench-based processes at commercial production-grade fabrication facilities in the US. Apart from above achievements, a Process Development Kit (PDK) was successfully developed for planar type SiC CMOS/LDMOS.

42 ENGINEERING↗

Enhancement of Distribution System Resilience Through the Application of Volt-Var Regulation Devices

This paper discusses a practical implementation of locating and sizing dynamic reactive compensation using an impedance matrix (Zbus) approach to improve distribution system resilience in scenarios with high penetration of distributed resources. The modeled system is a 14.2 kV radial residential system modified to be fed by a combination of traditional sources and solar resources. Time-varying loads and PV sources are connected along the feeder to simulate the challenging operational voltage regulation scenarios faced by Modern Distribution Systems. Additionally, enhancement of the resilience of the electrical system is demonstrated through analyzing the effect of a topology change to the system. This study uses the GridLAB-D software.

42 ENGINEERING↗

Real-time Simulation Framework for Hardware-in-the-Loop Testing of Multi-port Autonomous Reconfigurable Solar Power Plant (MARS)

Multiport autonomous reconfigurable solar power plant (MARS) has been proposed for integrated development of photovoltaic (PV) and energy storage system (ESS) that can connect to high-voltage direct current (HVdc) and alternating current (ac) transmission grid. To de-risk the development of this complex integrated system that consists of hundreds to thousands of power electronics modules, a controller hardware-in-the-loop (cHIL) test setup will be extremely beneficial. The cHIL testing can be used for evaluation of modules as well as the hierarchical control system in MARS. With the unique configuration of power electronics modules in MARS, it becomes necessary to develop custom-designed real-time simulation models in the cHIL setup in absence of off-the-shelf models. In this paper, high-fidelity dynamic model of MARS, control algorithms at the lower level, and required communication algorithms are developed and optimized for real-time performance in the cHIL setup. Real-time experimental results from the cHIL are provided.

Dong, Zerui↗

Predicting Thermal Response in a Li-ion Cell on a UAV Fight Profile

As the energy storage devices continue to "pack" more energy in a small space, any damage, battery component failure, manufacturing defect, or electrically abusing the battery can lead to catastrophic thermal runaway events. A catastrophic thermal event in a cell leads to high temperature, in some instances spewing of battery materials due to gas development from side reactions initiated due to high internal temperatures. Also, a thermal runaway event can propagate from a single "failed" cell to the pack in a battery pack, leading to a more significant event. Mitigating a thermal runaway event is important in the commercial and automotive sectors. However, preventing such events in an electric aircraft (or air taxis) is paramount due to the lack of alternatives in the event of a failure. Battery prognostics algorithms allow the prediction of state-of-charge (SOC) and end-of-life (EOL) of a Li-ion battery in a UAV (unmanned air vehicle) [1]. For this presentation, we will extend this two-level battery predictive algorithm to predict SOC, EOL, and estimated maximum temperature during a simulated flight. The model is extended by integrating a lumped physics-driven thermal model for high current densities [2]. The parameters used to control SOC and EOL are maximum storable charge, time constant for Li-ion diffusivity in the carbon particles, and internal cell resistance. Cycling leads to an increase in the heat generated by an aged Li-ion cell with a LiyCoO2 (LCO) cathode and a LixC6 (MCMB) anode. The aging of a cell leads to increase in SEI layer thickness, the diffusion time for the lithium ions inside the electrodes, and the local reaction rates, in addition to the thermodynamic abuse caused by fixed cycling voltages controlled by a Battery Management System. As the battery ages, the cell resistance increases, while the onset temperature of the thermal runaway decreases (depends on the cell chemistry and cell abuse history). Any large deviation of the cell temperature from the estimated (expected) value can identify a faulty cell. Since SEI decomposition has the lowest onset temperature in the series of reactions leading to thermal runaway, the model considers the self-heating rate of the SEI decomposition as onset temperature (similar to Ref. [3]). The parameters in the Arrhenius equation for the SEI heating rate depend on the number of cycles, the cell's operating temperature, and the cell's abuse history [4,5]. Coupling the electrochemical, thermal, and aging model allow the prognostic algorithm to estimate a typical cell voltage and temperature as a function of age (cycling and calendar), whose departure from measured values from the BMS is used to identify a safety event. In addition, we will present the results from two simulated flight scenarios for a UAV: typical and extreme, since the power requirements vary significantly during take-off, landing, and changing altitudes, while the power requirements remain low during the cruise. For this presentation, the power requirement for a battery pack in a UAV is scaled to a single cell. This cell is cycled through a simulated profile, and the data is collected and used to predict a safety event.

Li-ion↗

Reducing the Vulnerability of Electric Power Grids to Terrorist Attacks

This report describes the development of a cascading outage analyzer that, given an initial disturbance on an electric power system, checks for thermal overloads, under-frequency and over-frequency conditions, and under-voltage conditions that would result in removal of elements from the system. The analyzer simulates the successive tripping of elements due to protective actions until a post-event steady state or a system blackout is reached.

20 FOSSIL-FUELED POWER PLANTS↗

Distribution Grid Impacts of Community Solar [Slides]

Community solar (CS) projects often face uncertain interconnection costs and fees associated with distribution grid infrastructure upgrades required to connect the project. These costs can determine the economic viability of a CS project, but they are difficult to assess. Cost uncertainty can discourage new projects and prevent communities from accessing the benefits of community solar projects. At the same time, CS deployment strategies hold potential to defer or avoid some distribution costs due to new loads. To mitigate CS interconnection costs, it is important to find least-cost combinations of distribution system infrastructure solutions (transformer upgrades, reconductoring, voltage regulators, storage), and to understand how location of CS projects within a feeder impact distribution grid upgrade costs. This study aims to quantify CS impacts on the distribution grid and provide policy and regulatory insights and CS deployment strategies to address them. It is the first analysis that has systematically studied the technical impacts of community solar projects on a wide range of distribution feeders using state-of-the-art optimization and power flow tools. The analysis employs Berkeley Lab’s novel Least-cost Optimal Distribution Grid Expansion (LODGE) model, a deterministic version of the REPAIR model, that optimally upgrades hundreds or even thousands of distribution circuits or feeders. This is the first application of the LODGE model. LODGE finds the least-cost portfolio of traditional distribution system upgrades to integrate CS in combination with alternative solutions, such as utility-owned storage and downsizing CS capacity. Working with a set of least-cost solutions per feeder allows us to benchmark, compare and find techno-economic trends in CS interconnection.

14 SOLAR ENERGY↗

Cavallo's multiplier for in situ generation of high voltage

Here, a classic electrostatic induction machine, Cavallo's multiplier, is suggested for in situ production of very high voltage in cryogenic environments. The device is suitable for generating a large electrostatic field under conditions of very small load current. Operation of the Cavallo multiplier is analyzed, with quantitative description in terms of mutual capacitances between electrodes in the system. A demonstration apparatus was constructed, and measured voltages are compared to predictions based on measured capacitances in the system. The simplicity of the Cavallo multiplier makes it amenable to electrostatic analysis using finite element software, and electrode shapes can be optimized to take advantage of a high dielectric strength medium such as liquid helium. A design study is presented for a Cavallo multiplier in a large-scale, cryogenic experiment to measure the neutron electric dipole moment.

47 OTHER INSTRUMENTATION↗

Analysis of PV Fleet Performance in Western United States During August 2020 Extreme Heat Wave

Starting in June 2020 through the end of that year, the western and central United States experienced a widespread heat wave and drought, which resulted in US$5.44 billion (CPI-adjusted) worth of damages. The ongoing heat and drought produced record large wildfires across the region, responsible for an additional US$19.9 billion in damage. These natural disasters directly impacted the energy system in the western US, leading to power blackouts in August 2020. In this work, we analyze the NLR PV Fleets data set, focusing on the geographic area covered by the Western Coordinating Council (WECC). We find that over the 10-day period from August 14 through 24, the median PV system produced 12% lower energy than expected, with some locations experiencing total losses of around 30%. Analyzing the spatial-temporal structure of the data and supplementing with limited operational current and voltage data where available, we find that system underperformance was more strongly impacted by irradiance reduction from wildfire smoke rather than by the high heat itself.

14 SOLAR ENERGY↗

Hy-wire measurements of atmospheric potential

A method for directly measuring the electric potential drop across the lowest portion of the atmosphere by using an apparatus called Hy-wire is described. The Hy-wire system consists of a long, high-voltage, insulated conductor connected at the top to a wire-mesh braid and terminated at the bottom inside a large-diameter corona ball mounted on 1 m Teflon legs. The system impedance is near 10 billion ohms, while the grounded mode, Hy-wire draws about 10 micro-a at 500 m altitude. Around-the-clock measurements with characteristic peaks near 1530 and 1900 UT of potentials near 125,000 volts are presented, with total daily average potential near 90,000 volts at 507 m altitude. The experimental weather conditions varied from clear to local fog, except that there was only trace precipitation. The data have been interpreted in terms of the possible source of the potential variations; neither a local nor a global source is clearly indicated.

Holzworth, R. H.↗

Model-Free Dynamic Voltage Control of Distributed Energy Resource (DER)-Based Microgrids

In this paper, we present a new control technique for sustaining dynamic voltage stability by effective reactive power control and coordination of distributed energy resources (DERs) in microgrids. The proposed control technique is based on model-free control (MFC), which has shown successful operation and improved performance in different domains and applications. This paper presents its first use in the voltage stability of a microgrid setting employing multiple synchronous generator (SG)-based and power electronic (PE)-based DERs. MFC is a computationally efficient, data-driven control technique that does not require modelling of the different components and disturbances in the power system. It is utilized as an online controller to achieve the dynamic voltage stability of a microgrid system under different disturbances and fault conditions. A 21-bus microgrid system fed by multiple DERs is considered as a case study and the overall dynamic voltage stability is investigated using time-domain dynamic simulations. Numerical results show that the proposed MFC provides improvements on the dynamic load bus voltage profiles and requires less computational time as compared to the traditional enhanced microgrid voltage stabilizer (EMGVS) scheme. Due to its simplicity and low computational requirement, MFC can be easily implemented in resource-constrained computing devices such as smart inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Progress in the ITER electron cyclotron heating and current drive system design

We present that an electron cyclotron system is one of the four auxiliary plasma heating systems to be installed on the ITER tokamak. The ITER EC system consists of 24 gyrotrons with associated 12 high voltage power supplies, a set of evacuated transmission lines and two types of launchers. The whole system is designed to inject 20 MW of microwave power at 170 GHz into the plasma. The primary functions of the system include plasma start-up, central heating and current drive, and magneto-hydrodynamic instabilities control. The design takes present day technology and extends towards high power CW operation, which represents a large step forward as compared to the present state of the art. The ITER EC system will be a stepping stone to future EC systems for DEMO and beyond.The EC system is faced with significant challenges, which not only includes an advanced microwave system for plasma heating and current drive applications but also has to comply with stringent requirements associated with nuclear safety as ITER became the first fusion device licensed as basic nuclear installations as of 9 November 2012.Since conceptual design of the EC system established in 2007, the EC system has progressed to a preliminary design stage in 2012, and is now moving forward towards a final design. Lastly, the majority of the subsystems have completed the detailed design and now advancing towards the final design completion.

42 ENGINEERING↗

A Unified Wireless Charger, On-Board Charger, and Auxiliary Power Module for Electric Vehicle Charging Systems

This paper proposes a unified electric vehicle (EV) charging architecture that integrates wireless power transfer (WPT), an on-board charger (OBC), and an auxiliary power module (APM) within a single architecture. By sharing a multi-functional magnetic structure and active switch bridges, the proposed topology eliminates additional transformers and converter stages, reducing hardware complexity and improving power density. A multipurpose magnetic design achieves magnetic decoupling among the WPT, OBC, and APM functions while maintaining the required coupling for each mode. Through electrical reconfiguration, the WPT operates as an LCC-S converter, whereas the OBC and APM operate as dual-active-bridge (DAB) converters. The system supports multiple operating modes, including simultaneous high-voltage and lowvoltage battery charging. Finite-element and circuit simulations verify the magnetic characteristics and system operation, demonstrating the feasibility of the proposed unified architecture for EV charging applications.

Jo, Cheolhui [ORNL] (ORCID:0000000322692434)↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Proposal of an Arc Detection Technique Based on RF Measurements for the ITER ICRF Antenna

RF arc detection is a key operational and safety issue for the ICRF system on ITER. Indeed the high voltages inside the antenna put it at risk of arcing, which could cause substantial damage. This paper describes the various possibilities explored by circuit simulation and the strategy now considered to protect the ITER ICRF antenna from RF arcs.

43 PARTICLE ACCELERATORS↗

Impact of Cyber Attacks on High Voltage DC Transmission Damping Control

Electric grids have evolved to being a huge cyberphysical system (CPS) that combines intelligent electronic devices (IEDs), computing resources, communication networks and electricity infrastructures. The wide attack surface and increasing dependence on communication make power systems vulnerable to cyber attacks. This paper studies the impact of cyber attacks on high voltage DC (HVDC) transmission oscillation damping control. Three kinds of cyber attack models are considered: timing attack , replay attack, and false data injection attack. The attacks are applied to the HVDC damping controller, which requires widearea measurements and long-distance communication. A modified IEEE New England 39-Bus AC-HVDC system is used as the test system. Simulation results have shown that all three kinds of attacks are capable of driving the AC-HVDC system into swing or unstable conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of Augmented Spark Impinging Igniter System for Methane Engines

The Lunar Cargo Transportation and Landing by Soft Touchdown (Lunar CATALYST) program is establishing multiple no-funds-exchanged Space Act Agreement (SAA) partnerships with U.S. private sector entities. The purpose of this program is to encourage the development of robotic lunar landers that can be integrated with U.S. commercial launch capabilities to deliver payloads to the lunar surface. As part of the efforts in Lander Technologies, NASA Marshall Space Flight Center (MSFC) is developing liquid oxygen (LOX) and liquid methane (LCH4) engine technology to share with the Lunar CATALYST partners. Liquid oxygen and liquid methane propellants are attractive owing to their relatively high specific impulse for chemical propulsion systems, modest storage requirements, and adaptability to NASA's Journey to Mars plans. Methane has also been viewed as a possible propellant choice for lunar missions, owing to the performance benefits and as a technology development stepping stone to Martian missions. However, in the development of methane propulsion, methane ignition has historically been viewed as a high risk area in the development of such an engine. A great deal of work has been conducted in the past decade devoted to risk reduction in LOX/CH4 ignition. This paper will review and summarize the history and results of LOX/CH4 ignition programs conducted at NASA. More recently, a NASA-developed Augmented Spark Impinging (ASI) igniter body, which utilizes a conventional spark exciter system, is being tested with LOX/CH4 to help support internal and commercial engine development programs, such as those in Lunar CATALYST. One challenge with spark exciter systems, especially at altitude conditions, is the ignition lead that transmits the high voltage pulse from the exciter to the spark igniter (spark plug). The ignition lead can be prone to corona discharge, reducing the energy delivered by the spark and potentially causing non-ignition events. For the current work, a commercial compact exciter system, which eliminates this high voltage cabling, was tested at altitude conditions. A modified, conventional exciter system with an improved ignition lead was also recently tested at altitude conditions. This test program demonstrated the capability of these exciter systems to operate at altitude. While more extensive testing may be required, these systems or similar ones may be used for future NASA and commercial engine programs.

methane↗