Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Preparing Solar Photovoltaic Systems Against Storms. Pre-Storm Solar PV Checklist: Utility-Scale Ground-Mounted Systems

Through funding provided by the U.S. Department of Energy, the National Renewable Energy Laboratory (NREL) has used subject matter experts to compile a set of checklists to help Puerto Rico and other communities prepare for storms. Renewable energy and distributed energy systems have the potential to provide power to neighborhoods, vulnerable residents, and certain facilities within a community, if those systems are designed to provide power during a grid disruption. The storm-hardening checklists provide storm preparation actions that can increase the chances that solar photovoltaic (PV) systems are available when communities need them most. This resource was translated from English to Spanish for greater accessibility.

POWER TRANSMISSION AND DISTRIBUTION,SOLAR ENERGY↗

Systems and methods for enhanced power system model validation

A system for enhanced power system model validation is provided. The system includes a computing device including at least one processor in communication with at least one memory device. The at least one processor is programmed to store a plurality of models for a plurality of devices and a plurality of input files associated with the plurality of models, receive, from a user, a selection of model of the plurality of models to simulate, retrieve one or more input files of the plurality of input files, perform a model validity check on the selected model, if the selected model passed the model validity check, perform a model calibration on the selected model, and if the selected model passed the model calibration, perform a post evaluation on the selected model.

Wang, Honggang↗

Cooling systems having an integrated ionic liquid salt dehumidification system

A cooling system utilizes an organic ionic salt composition for dehumidification of an airflow. The organic ionic salt composition absorbs moisture from an inlet airflow to produce an outlet airflow with a reduce moisture from that of the inlet airflow. The organic ionic salt composition may be regenerated, wherein the absorbed moisture is expelled by heating with a heating device. The heating device may be an electrochemical heating device, such as a fuel cell, an electrochemical metal hydride heating device, an electrochemical heat pump or compressor, or a condenser of a refrigerant cycle, which may utilize an electrochemical pump or compressor. The efficiency of the cooling system may be increased by utilization of the waste heat the cooling system. The organic ionic salt composition may circulate back and forth or in a loop between a conditioner, where it absorbs moisture, to a regenerator, where moisture is desorbed by heating.

Bahar, Bamdad↗

Simulation system for testing a radar system

A simulation system for use in testing a radar system comprises a coarse delay module, a fine delay module, and a doppler shift module. The coarse delay module is configured to receive a first stream of digital data samples that are sampled from a radar signal at a sample time period or a second stream of digital data samples that are processed by another simulation system component and delay the digital data samples by a selectable first delay time that is greater than or equal to the sample time period. The fine delay module is configured to receive the digital data samples and filter the digital data samples to represent delay by a selectable second delay time that is less than the sample time period. The doppler shift module is configured to receive the digital data samples and adjust a value of a frequency content of the fine delayed samples.

Chritton, Audrey L.↗

Methods and systems for rebalancing electrolytes for a redox flow battery system

A rebalancing reactor for a redox flow battery system may include a first side through which hydrogen gas is flowed, a second side through which electrolyte from the redox flow battery system is flowed, and a porous layer separating and fluidly coupled to the first side and the second side, wherein, the hydrogen gas and the electrolyte are fluidly contacted at a surface of the porous layer, and a pressure drop across the second side is less than a pressure drop across the porous layer. In this way, rebalancing of electrolyte charges in a redox flow battery system may be performed with increased efficiency and cost effectiveness as compared to conventional rebalancing reactors.

Evans, Craig E.↗

Testing Results from the Low Activity Waste Pretreatment System (LAWPS) Full-Scale Ion Exchange Column Test and Engineering Scale Integrated System Test - 18634

The U.S. Department of Energy (DOE), Office of River Protection's (ORP) primary mission is to retrieve and treat Hanford's tank waste and close the Tank Farms to protect the Columbia River. Mixed radioactive waste is stored in 177 underground tanks at the Hanford Site as reported in DOE/ORP 2003- 02, Environmental Impact Statement for Retrieval, Treatment, and Disposal of Tank Waste and Closure of the Single Shell Tanks at the Hanford Site, Richland WA, Inventory and Source Term Data Package. The 177 underground tanks are estimated to contain about 56 million gallons of waste. The Low Activity Waste Pretreatment System (LAWPS) Project provides for the early production of immobilized low activity waste (ILAW) by feeding LAW directly from Tank Farms to the Hanford Waste Treatment Plant's (WTP's) LAW Facility, bypassing the Pretreatment Facility. Prior to the transfer of feed to the WTP LAW Vitrification Facility, tank supernatant waste will be pretreated in the LAWPS to meet the WTP LAW waste acceptance criteria. The LAWPS will also facilitate the return of secondary liquid wastes from the WTP LAW Vitrification Facility to the Tank Farms. In November of 2015 DOE's Tank Operations Contractor, Washington River Protection Solutions (WRPS), awarded a contract to the AECOM team to design, fabricate and operate two test platforms to generate performance data at two different scales and demonstrate technology maturation. The first platform models the ion exchange (IX) columns at full scale, and the second platform models the integrated flowsheet (cross flow filter (CFF) and IX) at 1/9. scale. Overarching technical objectives of performing the full-scale ion exchange test and the engineering-scale integrated test are to: 1. Test interactions between unit process operations; 2. Test removal of non-radioactive cesium from process stream; 3. Test removal of undissolved solids from process stream; 4. Confirm operational flow rate range and stability; 5. Confirm volumetric throughput of waste stream over flow operating range; 6. Confirm range of process temperatures over planned operating range; 7. Establish system hydraulics and process criteria; 8. Coordinate key control and monitoring components; 9. Establish treated product chemistry meets requirements (cesium, solids, and pH); and 10. Test the hazard control strategy for a no flow condition through the IX column. Data collected during testing will be used by WRPS to validate the preliminary design, inform the final design of the permanent plant equipment, and demonstrate that the critical technology elements have advanced to a technology readiness level of 6 (prototypical system validation in a relevant environment). Testing on both platforms started in fall of 2016 generating NQA-1 data. This paper covers test results from the first five phases of testing on the 1/9. scale integrated test platform. A further three phases of testing are currently being executed, these including a 5.6 M sodium simulant containing foulant, a high viscosity simulant and finally a run performed with a lower Cs concentration (all earlier tests were spiked to 4 x Cs to reduce volume and cost). Results from these tests were not available at the time of writing available. Results are also presented from the full scale IX testing. Eight test were performed covering column loading, elution and regeneration; column loading, elution and regeneration with upflow displacement; IX column loading and gas migration; resin removal; solids accumulation; and IX column emergency recirculation and vent. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Systems Safety Evaluation Based on System Thinking

Every engineer knows well and always considers about 'The local optimization makes the entire worst', and therefore well balanced design is required. Even the total safety has been assured by the safety design based on defense in depth concept, operational problem would occur by the chain of the fallacy of the defense in depth, then safety culture degradation, and finely organizational accident eventually happened. Probabilistic approach is required to the problem. We should answer to the question 'Safety Goal: How safe is safe enough?' for public acceptance. To respond to the operational problem and safety goal question, PRA, Probabilistic Risk Analysis is required. Further, Risk Communication should include comparison and selection among technical systems by risk and benefit analysis. Therefore, systems safety consideration is important based on systems thinking with considering following characteristics: - Goal-oriented- Optimization, Alternative proposals; - Global perspective- Bird's Eye; - Hierarchy- Isomorphism; - Life Cycle: Plan-Design-Construction-Use-Disposal; - Learning and Evolution. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimum Operation of Microgrid Systems that Employ PV Solar and Battery Systems

On a global scale, over 1.3 billion lack access to electricity (85% in rural areas), and approximately 2.8 billion people rely on traditional biomass for cooking. The World Health Organization estimates that household air pollution from inefficient stoves causes more premature deaths than malaria, tuberculosis, and HIV/AIDS. Increasing demand for energy has led to dramatic increases in emissions. The need for reliable electricity and limiting emissions drives research on Resilient Hybrid Energy Systems (RHESs), which provide cleaner energy by combining wind, solar, and biomass energy with traditional fossil energy, increasing production efficiency and reliability and reducing generating costs and emissions. Microgrids have been shown as an efficient means of implementing RHESs, with some focused mainly on reducing the environmental impact of electric power generation. The technical challenges of designing, implementing, and applying microgrids involve conducting a cradle-to-grave Life Cycle Analysis (LCA) to evaluate these systems’ environmental and economic performance under diverse operating conditions to evaluate resiliency. A sample RHES was developed and used to demonstrate the implementation in rural applications, where the system can provide reliable electricity for heating, cooling, lighting, and pumping clean water. The model and findings can be utilized by other regions around the globe facing similar challenges.

Nagapurkar, Prashant↗

Control and Optimization of Energy Storage System in Power Distribution System

The widespread adoption of electric vehicles (EVs) and transportation electrification is encumbered by two chief barriers: i) the limited driving range of EVs in the market today and ii) inadequate fast-charging infrastructure for long-distance trips. Extreme fast charging (XFC) technology can recharge EVs in less than 10 minutes for 200 miles range. Firstly, a novel robust optimization-based mixed integer linear programming model is proposed to size a battery energy storage system (BESS) and PV system in an XFCS. In this part, it is assumed that the sizing and location of the XFCS are known. Secondly, the aforesaid assumption is relaxed, and a strategic multi-period coordinated planning model is proposed to optimally site and size BESS-assisted charging stations in a highway transportation network and PV systems in a power distribution network by considering the coupling between both networks. Optimal operation and control of BESS-assisted EV charging stations are vital to alleviate the adverse impact of extreme fast charging of EVs on the host power network. A joint solution is proposed to mitigate the steady state and transient impact of extremefast charging of EVs and ensure grid-friendly integration of XFCSs with the host grid. Lastly, to make the operation of the XFCS cost-effective, a multi-layered energy management framework is proposed for the XFCS by considering forecast uncertainties, monthly demand charges reduction, and BESS degradation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Human-system Interface Style Guide for ACORN Control System

The purpose of this style guide is to provide a clear, consistent framework for the design and development of human system interfaces (HSIs) used throughout the Fermilab accelerator complex. It establishes a shared visual and interaction foundation to ensure that interfaces remain intuitive, effective, and cohesive, regardless of when or by whom they are developed. By adhering to these guidelines, developers can avoid introducing unnecessary deviations that compromise usability or increase system training burden. This consistency is especially critical in long-term, multi-contributor projects where interface continuity and maintainability are paramount. This document serves as a practical reference for all HSI development activities related to the accelerator control environment. While the guidance provided is comprehensive, it is not exhaustive of every potential design scenario. As such, the style guide is intended to function as a living document, subject to regular review and revision. Updates will be made at least annually to incorporate emerging best practices, operational feedback, and evolving system needs. Areas where detailed guidance is still under development are clearly indicated in gray throughout the document and will be addressed in future revisions according to project priorities.

Hill, Rachael [Idaho Natl. Lab.] (ORCID:0000000263↗

Energy management systems for forecasted demand error compensation using hybrid energy storage system in nanogrid

This paper proposes an energy management system (EMS) for nanogrids to balance the power supply and forecasted demand in consideration of forecasting errors arising from high instantaneous demand. The proposed EMS employs a power-balancing optimization process for forecasted demand and a reference power modulation strategy for forecasting errors. This power-balancing optimization utilizes nanogrid sources, such as photovoltaics, fuel cells, and batteries, to meet forecasted demand and a supercapacitor charging process to overcome issues with a low energy density. The proposed reference power modulation strategy is utilized to allocate power from a hybrid energy storage system consisting of a battery and supercapacitor in order to compensate for forecasting errors. In addition, this proposed strategy considers battery and supercapacitor constraints such as the power changing rate and total power limitations. Further, the power-balancing optimization process also operates at faster sampling rate than the reference power modulation process in order to improve the computational efficiency. The performance of the proposed EMS is evaluated using real data obtained from the Korea Electric Power Exchange.

25 ENERGY STORAGE↗

Duplications and losses of genes encoding known elements of the stress defence system of the Aspergilli contribute to the evolution of these filamentous fungi but do not directly influence their environmental stress tolerance

The contribution of stress protein duplication and deletion events to the evolution of the Aspergilli was studied. We performed a large-scale homology analysis of stress proteins and generated and analysed three stress defence system models based on Saccharomyces cerevisiae , Schizosaccharomyces pombe and Aspergillus nidulans . Although both yeast-based and A. nidulans -based models were suitable to trace evolutionary changes, the A. nidulans -based model performed better in mapping stress protein radiations. The strong Mantel correlation found between the positions of species in the phylogenetic tree on the one hand and either in the A. nidulans -based or S. cerevisiae -based models on the other hand demonstrated that stress protein expansions and reductions contributed significantly to the evolution of the Aspergilli. Interestingly, stress tolerance attributes correlated well with the number of orthologs only for a few stress proteins. Notable examples are Ftr1 iron permease and Fet3 ferro-O 2 -oxidoreductase, elements of the reductive iron assimilation pathway, in the S. cerevisiae -based model, as well as MpkC, a HogA-like mitogen activated protein kinase in the A. nidulans-based model. In the case of the iron assimilation proteins, the number of orthologs showed a positive correlation with H 2 O 2 -induced stress tolerance while the number of MpkC orthologs correlated positively with Congo Red induced cell wall stress, sorbitol induced osmotic stress and H 2 O 2 induced oxidative stress tolerances. For most stress proteins, changes in the number of orthologs did not correlate well with any stress tolerance attributes. As a consequence, stress tolerance patterns of the studied Aspergilli did not correlate with either the sets of stress response proteins in general or with the phylogeny of the species studied. These observations suggest that stress protein duplication and deletion events significantly contributed to the evolution of stress tolerance attributes of Aspergilli. In contrast, there are other processes, which may counterbalance the effects of stress gene duplications or deletions including (i) alterations in the structures of stress proteins leading to changes in their biological activities, (ii) varying biosynthesis of stress proteins, (iii) rewiring stress response regulatory networks or even (iv) acquiring new stress response genes by horizontal gene transfer. As a result, all these multilevel changes are indispensable for the successful adaptation of filamentous fungi to altering environmental conditions, especially when these organisms are entering new ecological niches.

59 BASIC BIOLOGICAL SCIENCES↗

ADP-Based Home Energy Management System: A Case Study Using Dynamo: Preprint

This paper explores Home Energy Management System (HEMS) algorithms to minimize household cost while maintaining comfort when faced with uncertain weather, and demand. Specifically, we consider a HEMS that optimizes forward looking schedules for a home's heating, ventilation, and air conditioning (HVAC); water heater (WH); and electric vehicle (EV) charging while considering uncertainty in outside temperature, hot water usage, and non-controllable load (NCL). We adopt a Dynamic Programming (DP) formulation and utilize the Dynamic programming for Adaptive Modeling and Optimization (DYNAMO) toolkit to implement DP and approximate dynamic programming (ADP) algorithms. Simulation results under a single tariff plan compare the quality of the solution generated by ADP to that of DP, and show significant improvement in computation time while maintaining acceptable solution accuracy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchronization of Coupled Dynamical Systems: Tolerance to Weak Connectivity and Arbitrarily Bounded Time-Varying Delays

We study synchronization of coupled linear systems over networks with weak connectivity and time-varying delays. We focus on the case that the internal dynamics are time-varying but non-expansive. Both uniformly connected and infinitely connected communication topologies are considered. A new concept of P-synchronization is introduced and we first show that global asymptotic P-synchronization can be achieved over directed networks with uniform joint connectivity and arbitrarily bounded delays. We then study the case of the infinitely jointly connected communication topology. In particular, for the undirected communication topologies, it turns out that the existence of a uniform time interval for the communication topology is not necessary and P-synchronization can be achieved when the time varying delays are arbitrarily bounded. Simulations are given to validate the theoretical results.

Linear time-varying system, Synchronization, Switc↗

Stochastic robust mathematical programming model for power system optimization

We present a stochastic robust framework for two-stage power system optimization problems with uncertainty. The model optimizes the probabilistic expectation of different worst-case scenarios with different uncertainty sets. In addition, a case study of unit commitment shows the effectiveness of the proposed model and algorithms.

97 MATHEMATICS AND COMPUTING↗