More on Non-standard Interaction at MINOS

We discuss about effects of the non-standard interaction of neutrinos with matter on the {nu}{sub e} appearance search in the MINOS experiment. We consider the effects of the complex phase of the interaction and of the uncertainty on {theta}{sub 23} also. We show that the oscillation probability can be so large that can not be explained by the ordinary oscillation. We show also how much constraints on the non-standard effects can be improved if the experiment does not observe {nu}{sub e} appearance signal.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

How Real Detector Thresholds Create False Standard Candles

GRB satellites are relatively inefficient detectors of dim hard bursts. For example, given two bursts of identical peak luminosity near the detection threshold, a dim soft burst will be preferentially detected over a dim hard burst. This means that a high E{sub peak} burst will need a higher peak luminosity to be detected than a low E{sub peak} GRB. This purely detector-created attribute will appear as a correlation between E{sub peak} and luminosity, and should not be interpreted as a real standard candle effect. This result derives from Monte Carlo simulations utilizing a wide range of initial GRB spectra, and retriggering to create a final ''detected'' sample. In sum, E{sub peak} is not a good standard candle, and its appearance as such in seeming correlations such as the Amati and other L{sub iso} vs. E{sub peak} relations is likely a ghost of real energy-related detection thresholds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resolving Standard and Nonstandard CP Violation Phases in Neutrino Oscillations

Neutrino oscillations can exhibit extra CP violation effects, beyond those expected from the standard Kobayashi-Maskawa phase delta, if non-standard neutrino interactions are at play. We show that it is possible to disentangle the two CP violating effects by measuring muon neutrino appearance using a near-far two detector setting in a neutrino factory experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Non-Standard Neutrino Interactions and Non-Unitarity Effects from TeV Seesaw Models

The motivations and phenomena of seesaw models at the TeV scale are briefly reviewed. We show that non-standard neutrino interactions and non-unitary effects are two typical features of low-scale scalar and fermionic seesaw models, respectively. For scalar seesaw models, in principle, significant non-standard interaction effects can be accommodated in the type-II seesaw model. As for the low-scale fermionic seesaw models, the inverse seesaw model turns out to be the most natural one, and could be well tested at the future long-baseline neutrino oscillation experiments and the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration of ac and dc magnetometers with a Dy{sub 2}O{sub 3} standard

The ac susceptibility and magnetization curves of a glued Dy{sub 2}O{sub 3} powder sample are measured by an ac susceptometer and a dc superconducting quantum interference device magnetometer, both of which have been calibrated previously. It is shown that the magnetic moment of the paramagnetic sample as a function of field and temperature may be accurately expressed by a combination of the Curie-Weiss law and the Langevin function at T > 45 K with three adjusting parameters, so that the dc magnetization curves and the magnitude and phase of ac susceptibility at different values of dc bias field measured by any magnetometer can be calibrated by using Dy{sub 2}O{sub 3} as a standard. The expressions are empirical and cannot be justified in the entire field and temperature range by existing theories of paramagnetism. Below 10 K, indication of approaching a possible phase transition is found. It is shown that pure Dy{sub 2}O{sub 3} powder may be used as a primary standard, with susceptibility [13.28(T+ 17)]{sup -1} emu/Oe/g at T > 50 K and H < 10 kOe, in consistency with the Curie-Weiss law and the quantum mechanical theory of paramagnetism.

36 MATERIALS SCIENCE↗

Standardizing Activation Analysis: New Software for Photon Activation Analysis

Photon Activation Analysis (PAA) of environmental, archaeological and industrial samples requires extensive data analysis that is susceptible to error. For the purpose of saving time, manpower and minimizing error, a computer program was designed, built and implemented using SQL, Access 2007 and asp.net technology to automate this process. Based on the peak information of the spectrum and assisted by its PAA library, the program automatically identifies elements in the samples and calculates their concentrations and respective uncertainties. The software also could be operated in browser/server mode, which gives the possibility to use it anywhere the internet is accessible. By switching the nuclide library and the related formula behind, the new software can be easily expanded to neutron activation analysis (NAA), charged particle activation analysis (CPAA) or proton-induced X-ray emission (PIXE). Implementation of this would standardize the analysis of nuclear activation data. Results from this software were compared to standard PAA analysis with excellent agreement. With minimum input from the user, the software has proven to be fast, user-friendly and reliable.

07 ISOTOPE AND RADIATION SOURCES↗

Laser-pumped paraffin-coated cell rubidium frequency standard

We have realized and studied a rubidium atomic frequency standard based on a paraffin-coated cell, exhibiting a short-term frequency stability <3 Multiplication-Sign 10{sup -12} {tau}{sup -1/2} between {tau} = 1 and 100 s. Characterization of the wall-coating is performed by measuring the T{sub 1} and T{sub 2} relaxation times. Perturbations of the medium- to long-term clock stability, due to variations in the laser-intensity, laser frequency, the microwave power shift, and the shifts due to temperature variations are measured and analyzed. A method for reducing the intensity light-shift by detuning the laser frequency and the resulting improvement in clock stability is demonstrated. This work is of relevance for further improvements on Rb cell standards using anti-relaxation wall-coating technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum resistance standard accuracy close to the zero-dissipation state

We report on a comparison of four GaAs/AlGaAs-based quantum resistance standards using an original technique adapted from the well-known Wheatstone bridge. This work shows that the quantized Hall resistance at Landau level filling factor ν=2 can be reproducible with a relative uncertainty of 32×10{sup −12} in the dissipationless limit of the quantum Hall effect regime. In the presence of a very small dissipation characterized by a mean macroscopic longitudinal resistivity R{sub xx}(B) of a few μΩ, the discrepancy ΔR{sub H}(B) between quantum Hall resistors measured on the Hall plateau at magnetic induction B turns out to follow the so-called resistivity rule R{sub xx}(B)=αB×d(ΔR{sub H}(B))/dB. While the dissipation increases with the measurement current value, the coefficient α stays constant in the range investigated (40−120 μA). This result enlightens the impact of the dissipation emergence in the two-dimensional electron gas on the Hall resistance quantization, which is of major interest for the resistance metrology. The quantum Hall effect is used to realize a universal resistance standard only linked to the electron charge e and the Planck constant h and it is known to play a central role in the upcoming revised Système International of units. There are therefore fundamental and practical benefits in testing the reproducibility property of the quantum Hall effect with better and better accuracy.

36 MATERIALS SCIENCE↗

Note: A novel design of a microwave feed for a microwave frequency standard with a linear ion trap

Linear ion traps are important tools in many applications, particularly in mass spectrum analyzers and frequency standards. Here a novel design of a microwave feed integrated into one electrode of a linear quadrupole ion trap is demonstrated for the application of a microwave frequency standard based on cadmium ions. The mechanical structure of the microwave feed is compact and easy to build. The ion trap integrated with this microwave feed is successfully applied to measure the hyperfine splitting of the ground state of {sup 113}Cd{sup +}, thus demonstrating the practicality and reliability of the microwave feed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards a graphene-based quantum impedance standard

Precision measurements of the quantum Hall resistance with alternating current (ac) in the kHz range were performed on epitaxial graphene in order to assess its suitability as a quantum standard of impedance. The quantum Hall plateaus measured with alternating current were found to be flat within one part in 10{sup 7}. This is much better than for plain GaAs quantum Hall devices and shows that the magnetic-flux-dependent capacitive ac losses of the graphene device are less critical. The observed frequency dependence of about −8 × 10{sup −8}/kHz is comparable in absolute value to the positive frequency dependence of plain GaAs devices, but the negative sign is attributed to stray capacitances which we believe can be minimized by a careful design of the graphene device. Further improvements thus may lead to a simpler and more user-friendly quantum standard for both resistance and impedance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental study of surface insulated-standard hybrid tungsten planar wire array Z-pinches at “QiangGuang-I” facility

The experimental results of the insulated-standard hybrid wire array Z pinches carried out on “QiangGuang-I” facility at Northwest Institute of Nuclear Technology were presented and discussed. The surface insulating can impose a significant influence on the dynamics and radiation characteristics of the hybrid wire array Z pinches, especially on the early stage (t/t{sub imp} < 0.6). The expansion of insulated wires at the ablation stage is suppressed, while the streams stripped from the insulated wires move faster than that from the standard wires. The foot radiation of X-ray is enhanced by increment of the number of insulated wires, 19.6 GW, 33.6 GW, and 68.6 GW for shots 14037S, 14028H, and 14039I, respectively. The surface insulation also introduces nonhomogeneity along the single wire—the streams move much faster near the electrodes. The colliding boundary of the hybrid wire array Z pinches is bias to the insulated side approximately 0.6 mm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evolving data standards for cryo-EM structures

Electron cryo-microscopy (cryo-EM) is increasingly being used to determine 3D structures of a broad spectrum of biological specimens from molecules to cells. Anticipating this progress in the early 2000s, an international collaboration of scientists with expertise in both cryo-EM and structure data archiving was established (EMDataResource, previously known as EMDataBank). The major goals of the collaboration have been twofold: to develop the necessary infrastructure for archiving cryo-EM-derived density maps and models, and to promote development of cryo-EM structure validation standards. We describe how cryo-EM data archiving and validation have been developed and jointly coordinated for the Electron Microscopy Data Bank and Protein Data Bank archives over the past two decades, as well as the impact of evolving technology on data standards. Just as for X-ray crystallography and nuclear magnetic resonance, engaging the scientific community via workshops and challenging activities has played a central role in developing recommendations and requirements for the cryo-EM structure data archives.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microwave frequency standard on {sup 25}Mg{sup +} ions: expected characteristics and prospects

A scheme of the new frequency standard is reported based on a microwave transition between hyperfine components of the ground state in {sup 25}Mg{sup +} ions. It is proposed to capture ions into a linear quadrupole Paul trap and to perform the laser cooling, as well as to prepare the particle ensemble and to implement detection by using a single laser system based on a semiconductor laser. Characteristics of the suggested frequency standard are estimated. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Creation of the first Russian time and frequency standard on a fountain of ultracold rubidium atoms

Technical specific features of the first Russian rubidium frequency standard of a fountain type are described, which are distinct from those of abroad analogues. Test results of separate systems and the metrological characteristics of the standard are presented. The achievable output frequency instability is 4 × 10{sup −16} per measurement interval of 24 hours and 1 × 10{sup −16} per 16 days. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Acousto-optic modulators for a controlled frequency shift of light beams in optical and microwave cold-atom frequency standards

A series of specialised acousto-optic modulators/frequency shifters based on paratellurite (TeO{sub 2}) single crystals is developed for systems of laser cooling and frequency stabilisation of laser sources in optical and microwave frequency standards based on cold strontium, rubidium and caesium atoms. The methods of calculation and optimisation of the main parameters of acousto-optic modulators are considered; their basic technical characteristics are experimentally investigated in the spectral range of optical radiation 460 – 900 nm and in the frequency shift range of 5 – 400 MHz. The modulators have a high diffraction efficiency, low power consumption and the ability to work with linearly and randomly polarised optical radiation. (frequency standards)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Testing the Standard Model at the Precision Frontier with the Q weak Experiment

The standard model of particle physics (SM) has been wildly successful describing the strong, electromagnetic, and weak forces between visible matter. Despite this success, there is a host of phenomena it fails to describe, including neutrino oscillations, gravity, dark matter, and baryon asymmetry. Something is missing—the theory is not complete. This conviction has compelled physicists to develop ever-more-stringent tests in the hope of finding cracks in the SM that could point to where the beyond-the-standard-model (BSM) physics might lie. Direct searches at high-energy colliders have yielded no evidence for some of the most intriguing possibilities, like supersymmetry, and have not been able to shed much light on where to look next.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance based approaches in standards and regulations for smart ventilation in residential buildings: a summary review

As ventilation systems become more sophisticated (or ‘smart’) standards and regulations are changing to accommodate their use. A key smart ventilation concept is to use controls to ventilate more at times it provides either an energy or IAQ advantage (or both) and less when it provides a disadvantage. This paper discusses the favorable contexts that exist in many countries, with regulations and standards proposing ‘performance-based approaches’ that both enable and reward smart ventilation. The paper gives an overview of such approaches from five countries. The common thread in all these methods is the use of metrics for the exposure to an indoor generated parameter (usually CO 2 ), and condensation risk. As the result, demand-control ventilation strategies (DCV) are widely and easily available on the market, with more than 20–30 systems available in some countries.