Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “source code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Delayed Gamma-Ray Spectroscopy for Non-Destructive Assay of Nuclear Materials

High-­energy, beta-delayed gamma-­ray spectroscopy is a potential, non-­destructive assay techniques for the independent verification of declared quantities of special nuclear materials at key stages of the fuel cycle and for directly assaying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Other potential applications include determination of MOX fuel composition, characterization of nuclear waste packages, and challenges in homeland security and arms control verification. Experimental measurements were performed to evaluate fission fragment yields, to test methods for determining isotopic fractions, and to benchmark the modeling code package. Experimental measurement campaigns were carried out at the IAC using a photo-­neutron source and at OSU using a thermal neutron beam from the TRIGA reactor to characterize the emission of high-­energy delayed gamma rays from 235 U, 239 Pu, and 241 Pu targets following neutron induced fission. Data were collected for pure and combined targets for several irradiation/spectroscopy cycle times ranging from 10/10 seconds to 15/30 minutes.The delayed gamma-ray signature of 241 Pu, a significant fissile constituent in spent fuel, was measured and compared to 239 Pu. The 241 Pu/ 239 Pu ratios varied between 0.5 and 1.2 for ten prominent lines in the 2700-­3600 keV energy range. Such significant differences in relative peak intensities make it possible to determine relative fractions of these isotopes in a mixed sample. A method for determining fission product yields by fitting the energy and time dependence of the delayed gamma-­ray emission was developed and demonstrated on a limited 235 U data set. De-­convolution methods for determining fissile fractions were developed and tested on the experimental data. The use of high count-­rate LaBr 3 detectors was investigated as a potential alternative to HPGe detectors. Modeling capabilities were added to an existing framework and codes were adapted as needed for analyzing experiments and assessing application-­specific assay concepts. A de-­convolution analysis of the delayed gamma-­ray response spectra modeled for spent fuel assemblies was performed using the same method that was applied to the experimental spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reproducibility of fixed-node diffusion Monte Carlo across diverse community codes: The case of water–methane dimer

Fixed-node diffusion quantum Monte Carlo (FN-DMC) is a widely trusted many-body method for solving the Schrödinger equation, known for its reliable predictions of material and molecular properties. Furthermore, its excellent scalability with system complexity and near-perfect utilization of computational power make FN-DMC ideally positioned to leverage new advances in computing to address increasingly complex scientific problems. Even though the method is widely used as a computational gold standard, reproducibility across the numerous FN-DMC code implementations has yet to be demonstrated. This difficulty stems from the diverse array of DMC algorithms and trial wave functions, compounded by the method’s inherent stochastic nature. Here, this study represents a community-wide effort to assess the reproducibility of the method, affirming that yes, FN-DMC is reproducible (when handled with care). Using the water–methane dimer as the canonical test case, we compare results from eleven different FN-DMC codes and show that the approximations to treat the non-locality of pseudopotentials are the primary source of the discrepancies between them. In particular, we demonstrate that, for the same choice of determinantal component in the trial wave function, reliable and reproducible predictions can be achieved by employing the T-move, the determinant locality approximation, or the determinant T-move schemes, while the older locality approximation leads to considerable variability in results. These findings demonstrate that, with appropriate choices of algorithmic details, fixed-node DMC is reproducible across diverse community codes—highlighting the maturity and robustness of the method as a tool for open and reliable computational science.

Della Pia, Flaviano [Univ. of Cambridge (United Ki↗

Methodology for Sensitivity Analysis of Homogenized Cross-Sections to Instantaneous and Historical Lattice Conditions with Application to AP1000® PWR Lattice

In the two-step method for nuclear reactor simulation, lattice physics calculations are performed to compute homogenized cross-sections for a variety of burnups and lattice configurations. A nodal code is then used to perform full-core analysis using the pre-calculated homogenized cross-sections. One source of uncertainty introduced in this method is that the lattice configuration or depletion conditions typically do not match a pre-calculated one from the lattice physics simulations. Therefore, some interpolation model must be used to estimate the homogenized cross-sections in the nodal code. This current study provides a methodology for sensitivity analysis to quantify the impact of state variables on the homogenized cross-sections. This methodology also allows for analyses of the historical effect that the state variables have on homogenized cross-sections. An application of this methodology on a lattice for the Westinghouse AP1000® reactor is presented where coolant density, fuel temperature, soluble boron concentration, and control rod insertion are the state variables of interest. The effects of considering the instantaneous values of the state variables, historical values of the state variables, and burnup-averaged values of the state variables are analyzed. Using these methods, it was found that a linear model that only considers the instantaneous and burnup-averaged values of state variables can fail to capture some variations in the homogenized cross-sections.

Price, Dean (ORCID:0000000309990111)↗

LevSeq: Rapid Generation of Sequence-Function Data for Directed Evolution and Machine Learning

Sequence-function data provides valuable information about the protein functional landscape but is rarely obtained during directed evolution campaigns. Here, we present Long-read every variant Sequencing (LevSeq), a pipeline that combines a dual barcoding strategy with nanopore sequencing to rapidly generate sequence-function data for entire protein-coding genes. LevSeq integrates into existing protein engineering workflows and comes with open-source software for data analysis and visualization. The pipeline facilitates data-driven protein engineering by consolidating sequence-function data to inform directed evolution and provide the requisite data for machine learning-guided protein engineering (MLPE). LevSeq enables quality control of mutagenesis libraries prior to screening, which reduces time and resource costs. Simulation studies demonstrate LevSeq’s ability to accurately detect variants under various experimental conditions. Lastly, we show LevSeq’s utility in engineering protoglobins for new-to-nature chemistry. Widespread adoption of LevSeq and sharing of the data will enhance our understanding of protein sequence-function landscapes and empower data-driven directed evolution.

59 BASIC BIOLOGICAL SCIENCES↗

Description of the code ANVIL (ANisotropic Vhf Impulse Location)

In this paper, we have developed a general, three-dimensional method to locate sources of earth-directed radiation which takes into account the flight paths of reflected signals. While time-of-arrival algorithms exist for locating radio sources using line-of-sight propagation paths, radio sources originating above the surface of the earth will not necessarily emit strong power along direct paths to satellites. A combination of direct and ground-reflected pulses or only ground-reflected signals from such sources could be received by satellite-borne sensors. The work presented here applies to satellite detection of sub-ionospheric radio sources in a vacuum environment with ideal reflection off the earth's surface. Because satellites are not static receivers, their configuration with respect to a radio source is not always optimal. Therefore, a statistical study is performed using 1000 randomized configurations of 24 satellites in middle earth orbit. For each configuration, the radio source latitude and longitude is fixed, and its altitude is varied from 1 to 97 km. An analytic direct-path algorithm using the five satellites nearest the radio source provides an initial guess for the radio source latitude and longitude. We find that, using this approximation, the mean error in the calculated nadir location has a maximum value of 134 m for the 97-km source altitude. The coordinates of the initial guess are used to define the origin of a grid within which an all-points search refinement is performed. Finally, using this procedure, the overall maximum mean error in radio source position is found to be on the order of the computational grid size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coded aperture imaging for fluorescent x-rays

We employ a coded aperture pattern in front of a pixilated charge couple device detector to image fluorescent x-rays (6–25 KeV) from samples irradiated with synchrotron radiation. Coded apertures encode the angular direction of x-rays, and given a known source plane, allow for a large numerical aperture x-ray imaging system. The algorithm to develop and fabricate the free standing No-Two-Holes-Touching aperture pattern was developed. The algorithms to reconstruct the x-ray image from the recorded encoded pattern were developed by means of a ray tracing technique and confirmed by experiments on standard samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiphysics Analyses of the Protected and Unprotected Loss of Forced Cooling Accidents in the HTR-PM

Here, we present the multiphysics simulation results for the protected pressurized and depressurized loss of forced cooling (PLOFC and DLOFC) events in the High-Temperature gas-cooled Reactor--Pebble-bed Module (HTR-PM) equilibrium core using the Griffin-Pronghorn coupled code system. Additionally, this paper discusses the strategy for estimating the spontaneous fission neutron source needed for unprotected events and re-criticality calculations. The solutions of the protected PLOFC and DLOFC events were verified against similar solutions obtained for temperature evolutions from the open literature. Both the average and maximum pebble surface temperatures behaved as expected during the DLOFC and remained below 1800 K. The PLOFC results are highly dependent on the ability to resolve the natural circulation in the core, which is impacted by the mesh resolution in Pronghorn. Furthermore, we present the results of the unprotected DLOFC transient to predict the timing of the re-criticality event, which occurred 47 hours after the onset of the transient, and the new steady-state power of 1.3 MW.

42 - ENGINEERING↗

PPT-GPU: Scalable GPU Performance Modeling

Performance modeling is a challenging problem due to the complexities of hardware architectures. In this paper, we present PPT-GPU, a scalable and accurate simulation framework that enables GPU code developers and architects to predict the performance of applications in a fast, and accurate manner on different GPU architectures. PPT-GPU is part of the open source project, Performance Prediction Toolkit (PPT) developed at the Los Alamos National Laboratory. We extend the old GPU model in PPT that predict the runtimes of computational physics codes to offer better prediction accuracy, for which, we add models for different memory hierarchies found in GPUs and latencies for different instructions. To further show the utility of PPT-GPU, we compare our model against real GPU device(s) and the widely used cycle-accurate simulator, GPGPU-Sim using different workloads from RODINIA and Parboil benchmarks. The results indicate that the predicted performance of PPT-GPU is within a 10% error compared to the real device(s). In addition, PPT-GPU is highly scalable, where it is up to 450x faster than GPGPU-Sim with more accurate results.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-27: A Tool for Routine Quality Assurance of Radiotherapy Dose Calculation Software

Purpose: Dose calculation software is thoroughly evaluated when it is commissioned; however, evaluation of periodic software updates is typically limited in scope due to staffing constraints and the need to quickly return the treatment planning system to clinical service. We developed a tool for quickly and comprehensively testing and documenting dose calculation software against measured data. Methods: A tool was developed using MatLab (The MathWorks, Natick, MA) for evaluation of dose calculation algorithms against measured data. Inputs to the tool are measured data, reference DICOM RT PLAN files describing the measurements, and dose calculations in DICOM format. The tool consists of a collection of extensible modules that can perform analysis of point dose, depth dose curves, and profiles using dose difference, distance-to-agreement, and the gamma-index. Each module generates a report subsection that is incorporated into a master template, which is converted to final form in portable document format (PDF). Results: After each change to the treatment planning system, a report can be generated in approximately 90 minutes. The tool has been in use for more than 5 years, spanning 5 versions of the eMC and 4 versions of the AAA. We have detected changes to the algorithms that affected clinical practice once during this period. Conclusion: Our tool provides an efficient method for quality assurance of dose calculation software, providing a complete set of tests for an update. Future work includes the addition of plan level tests, allowing incorporation of, for example, the TG-119 test suite for IMRT, and integration with the treatment planning system via an application programming interface. Integration with the planning system will permit fully-automated testing and reporting at scheduled intervals.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-173: Evaluation of the MicroSTAR Reader for the OSLD System for Remote Dosimetry Audits at the IROC HQAC

Purpose: Analysis of the performance of the microSTARii reader for optically stimulated luminescence dosimeters (OSLD) used by the IROC Houston Quality Assurance Center (IROC HQAC) for external audits compare to the characteristics of the Microstar reader. Methods: The IROC HQAC uses the Microstar reader for the OSLD program for verification of output of photon, electron and proton beams. The calculation of dose from the OSLD system is based on a group of factors defined at time of the commissioning of a batch of detectors. Factors like system sensitivity (SS), depletion (KD), element correction factor (ECF), linearity (KL), energy correction (KE). The new microSTARii unit presents many hardware and software upgrades that were considered useful for this program. Based on these changes many factors, that were considered reader dependent, were revised in order to analyze the effect of the new reading process. The SS, KD, ECF and KL were evaluated and compared with data defined based on reading done on Microstar reader. Results: The SS is reader specific and specified at 100 cGy dose level. This value is define per reading session and monitored over time. The KD factor was found to be different because of reading procedure are different. The ECF values changed for a group of nano dots compare to values defined based on reading done on the Microstar reader. The KL was defined for the reader. Conclusion: The new microSTARii reader presents new features that improve the efficiency of the OSLD program at the IROC HQAC. New characterization is needed before final implementation is done to match the requirements of the existing OSLD system defined for the Microstar reader. Changes in uncertainty of the results has not been analized.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-195: Gantry Angle Dependency of MLC Leaf Position Error

Purpose: The aim of this study was to investigate the gantry angle dependency of the multileaf collimator (MLC) leaf position error. Methods: An automatic MLC quality assurance system (AutoMLCQA) was developed to evaluate the gantry angle dependency of the MLC leaf position error using an electronic portal imaging device (EPID). To eliminate the EPID position error due to gantry rotation, we designed a reference maker (RM) that could be inserted into the wedge mount. After setting up the EPID, a reference image was taken of the RM using an open field. Next, an EPID-based picket-fence test (PFT) was performed without the RM. These procedures were repeated at every 45° intervals of the gantry angle. A total of eight reference images and PFT image sets were analyzed using in-house software. The average MLC leaf position error was calculated at five pickets (-10, -5, 0, 5, and 10 cm) in accordance with general PFT guidelines using in-house software. This test was carried out for four linear accelerators. Results: The average MLC leaf position errors were within the set criterion of <1 mm (actual errors ranged from -0.7 to 0.8 mm) for all gantry angles, but significant gantry angle dependency was observed in all machines. The error was smaller at a gantry angle of 0° but increased toward the positive direction with gantry angle increments in the clockwise direction. The error reached a maximum value at a gantry angle of 90° and then gradually decreased until 180°. In the counter-clockwise rotation of the gantry, the same pattern of error was observed but the error increased in the negative direction. Conclusion: The AutoMLCQA system was useful to evaluate the MLC leaf position error for various gantry angles without the EPID position error. The Gantry angle dependency should be considered during MLC leaf position error analysis.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-210: Independent MU Dose Calculation Software for S and S IMRT Using Modified Clarkson Integration Sector

Purpose: The purpose of this work was to develop and validate an open source independent MU dose calculation software for S and S IMRT based in the algorithm proposed by Kung et.al. Methods: Treatment plans were done using Iplan v4.5 BrainLAB TPS and S and S IMRT modality. A 6MV photon beam produced by a Primus linear accelerator equipped with an Optifocus MLC was used. TPS dose calculation algorithms were pencil beam and Monte Carlo. 230 IMRT treatments plans were selected for the study. The software was written under MALTLAB environment. Treatment plans were imported by the software using RTP format. Field fluences were reconstructed adding all segments.The algorithm implemented in the software calculates the dose at a reference point as the sum of primary and scatter dose. The primary dose is obtained by masking the fluence map with a circle of radius 1cm. The scatter dose is obtained through a shaped ring mask around the previous circle with a thickness of 0.5cm; the rings are increased one after another with constant thickness until cover the entire map of influence. The dosimetric parameters Sc, Sp and TPR vary depending on radio, the transmission effect of the MLC, inverse square law and dose profile are used for the calculation. Results: The average difference between measured and independent calculated dose was 0.4% ± 2.2% [−6.8%, 6.4%]. For 91% of the studied plans the difference was less than 3%. The difference between the measured and TPS dose with pencilbeam algorithm was 2.6% ± 1.41% [−2.0%, 5.6%] and Monte Carlo algorithm was 0.4% ± 1.5% [−4.9%, 3.7%]. The differences obtained are comparable to that obtained with the ionization chamber and TPS. Conclusion: The developed software is suitable for use in S and S IMRT dose calculation. This application is open and can be downloading under request.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-435: Development and Commissioning of a Complete System for In-Vivo Dosimetry and Range Verification in Proton Therapy

Purpose: In-vivo dose and beam range verification in proton therapy could play significant roles in proton treatment validation and improvements. Invivo beam range verification, in particular, could enable new treatment techniques one of which, for example, could be the use of anterior fields for prostate treatment instead of opposed lateral fields as in current practice. We have developed and commissioned an integrated system with hardware, software and workflow protocols, to provide a complete solution, simultaneously for both in-vivo dosimetry and range verification for proton therapy. Methods: The system uses a matrix of diodes, up to 12 in total, but separable into three groups for flexibility in application. A special amplifier was developed to capture extremely small signals from very low proton beam current. The software was developed within iMagX, a general platform for image processing in radiation therapy applications. The range determination exploits the inherent relationship between the internal range modulation clock of the proton therapy system and the radiological depth at the point of measurement. The commissioning of the system, for in-vivo dosimetry and for range verification was separately conducted using anthropomorphic phantom. EBT films and TLDs were used for dose comparisons and range scan of the beam distal fall-off was used as ground truth for range verification. Results: For in-vivo dose measurement, the results were in agreement with TLD and EBT films and were within 3% from treatment planning calculations. For range verification, a precision of 0.5mm is achieved in homogeneous phantoms, and a precision of 2mm for anthropomorphic pelvic phantom, except at points with significant range mixing. Conclusion: We completed the commissioning of our system for in-vivo dosimetry and range verification in proton therapy. The results suggest that the system is ready for clinical trials on patient.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-BRD-13: Quantum Annealing Applied to IMRT Beamlet Intensity Optimization

Purpose: We report on the first application of quantum annealing (QA) to the process of beamlet intensity optimization for IMRT. QA is a new technology, which employs novel hardware and software techniques to address various discrete optimization problems in many fields. Methods: We apply the D-Wave Inc. proprietary hardware, which natively exploits quantum mechanical effects for improved optimization. The new QA algorithm, running on this hardware, is most similar to simulated annealing, but relies on natural processes to directly minimize the free energy of a system. A simple quantum system is slowly evolved into a classical system, representing the objective function. To apply QA to IMRT-type optimization, two prostate cases were considered. A reduced number of beamlets were employed, due to the current QA hardware limitation of ∼500 binary variables. The beamlet dose matrices were computed using CERR, and an objective function was defined based on typical clinical constraints, including dose-volume objectives. The objective function was discretized, and the QA method was compared to two standard optimization Methods: simulated annealing and Tabu search, run on a conventional computing cluster. Results: Based on several runs, the average final objective function value achieved by the QA was 16.9 for the first patient, compared with 10.0 for Tabu and 6.7 for the SA. For the second patient, the values were 70.7 for the QA, 120.0 for Tabu, and 22.9 for the SA. The QA algorithm required 27–38% of the time required by the other two methods. Conclusion: In terms of objective function value, the QA performance was similar to Tabu but less effective than the SA. However, its speed was 3–4 times faster than the other two methods. This initial experiment suggests that QA-based heuristics may offer significant speedup over conventional clinical optimization methods, as quantum annealing hardware scales to larger sizes.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-267: Development of the Compact Graphite Calorimetry System for the High Energy Photon Beam

Purpose: Graphite calorimeter systems are used for the absolute photon dosimetry. But many electronics are demanded in order to measure the tiny temperature changes. Minimizing the control system is needed to make a portable graphite calorimeter. Methods: A Domen-type graphite calorimetry system is constructing to measure the absorbed dose of the high energy photon beam. The graphite calorimeter divided into three parts, Core, Jacket, and Shield. In order to measure the temperature rising of the core due to the radiation accurately, the temperatures of the jacket and the shield should be controlled properly. A commercial temperature controller (Model 350, Lake Shore Cryogenics) was used to minimize the size of control system for making a portable graphite calorimetry system at the cost of the measurement uncertainty. The PID control of the jacket is conducted by the software (LabView) and Model 350 maintain the temperature of shield. Results: Our design value of the heat deposition power in the core is 0.04 mW for the dose rate of 3 Gy/min where the temperature sensitivity of the graphite is 1.4 mK/Gy. While the residuals of the Steinhart-hart equation fitting for the core thermistor were less than 0.1 mK, the temperature resolution of Model 350 is 1 mK. The temperature of the shield was kept within the 5 mK when the room temperature variation was about 0.5 K. Conclusion: The resolution of Model 350 for the temperature measurement and control is not good enough as the control system for the compact graphite calorimetry system. But The performance of Model 350 is good enough to maintain the temperature of the shield constantly. The Model 350 will be replaced by the AC resistance bridge (Model 372, Lake Shore Cryogenics) for the core temperature measurement and the jacket control.

07 ISOTOPE AND RADIATION SOURCES↗

MO-FG-213-04: Managing the Relationship

Academic-industrial collaborations are playing an increasingly prominent role in medical physics research. Successful partnerships have enabled truly translational, benchtop-to-bedside research that has significantly and positively impacted our field. Given the current flat or depleting trends in federal funding, and the increasing emphasis in the medical physics community on demonstrating translatability, efficacy, and safety prior to widespread clinical use, it is anticipated that such partnerships will become ever more important in advancing our field. In the future, it is likely that neither academia alone, nor industry alone, will be able to bring significant innovation to successfully impact patient care in radiotherapy. Such innovation will require partnership and symbiosis through the lifetime of the project. This symposium is aimed at professionals from academia and the industry who are interested in either initiating new collaborations or maintaining and improving existing partnerships. We will hear from four thought leaders from industry and academia on critical aspects of building and maintaining successful academic-industrial research partnerships. The following topics will be addressed: 1. Motivations: The industry perspective [Kevin Brown, Elekta] What goes into the development of a company’s R&D roadmap What are the motivations and expectations of the industry from academic partners How can academics make a successful pitch by identifying projects aligned with a company’s roadmap Why are some relationships successful and some not Milestones and progress reports - Why do we need them 2. Motivations: The academic perspective [T. Rock Mackie, Univ. of Madison, WI; Tomotherapy] What are the motivations and expectations of academic partners from the industry What are the cultural differences in academia vs industry on sharing information, exchanging ideas Partnership or entrepreneurship? When does each option make sense 3. Industrial Grants and Research Contracts – a Primer [Norbert Pelc; Stanford University] What topics are suited to industrial grants vs. academic grants How do resources (personnel effort, tuition) get allocated and charged in academia What are reasonable resource and timeline requests for small and big projects; from small and big companies “Fair market value” considerations Sections of a research agreement (IP including software confidential information, publications, data, exclusivity, support) 4. Managing the relationship [John Wong, Johns Hopkins University] How to effectively collaborate with each other How to adapt to changes in the relationship How to renew funding with the industry Moderated Panel Discussion [All speakers + moderators] Learning Objectives: 1. Understand the motivations of each partner 2. Elements that contribute to a successful partnership 3. Avoiding pitfalls - Challenges on either side that may derail a project 4. How to frame a research grant and agreement 5. How to sustain the collaborative relationship Amit Sawant: Funding from: NIH. Varian, Elekta and VisionRT; Michelle Svatos: Employee and shareholder: Varian, Board Member, TopasMC; Kevin Brown: Employee, Elekta; T. Rock Mackie: Consultant, Accuray; Norbert Pelc: Research support: Philips Healthcare, GE Healthcare; John Wong: Funding from NIH, Xstrahl and Elekta. Co-founder and advisor for JPLC Associates, LLC.

07 ISOTOPE AND RADIATION SOURCES↗

Nalu

Nalu is a Sierra ToolKit (STK) based application module, and it has provided a set of "lessons learned" for the STK transition effort through its early adoption of STK. It makes use of the open-sourced Trilinos/ Tpetra library. Through the investment of LORD and ASCR projects, the Nalu code module has been extended beyond prototype status. Physics capability includes low Mach, variable density turbulent flow. The ongoing objective for Nalu is to facilitate partnerships with external organizations in order to extend code capability and knowledge; however, it is not intended to support routine CFD analysis. The targeted usage of this module is for non-NW applications that support work-for-others in the multiphysics energy sector.

Source record↗

bayesian_tensor_regression

We plan to release the code used to perform the experiment described in our upcoming publication, entitled “Bayesian Tensor Modeling for Distribution-on-Distribution Regression.” This code a Bayesian regression model with a multi-way Dirichlet prior to tensor input distributions. All code to be released implements a new model that is intended for open-source publication.

Murph, Alexander C. [Los Alamos National Lab]↗