Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software specification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

User Manual for the Thermal Hydraulic Code SE2RCT

SE2-ANL is a modified version of SUPERENERGY-2 which interfaces the power distribution in the ANL maintained physics codes for the user. SE2RCT is a special version of SE2-ANL developed for specific use on models of the Experimental Breeder Reactor-II (EBR-II). SE2RCT fulfills a specific role in the calculated results as part of the Fuels Irradiation and Physics Database (FIPD) and is built to connect with the Physics and Analysis DataBase (PADB) for metallic fuel research and development in advanced sodium-cooled fast reactors (SFRs) created for EBR-II. SE2RCT is primarily a thermal analysis code that interfaces with the RCT based pin power details instead of the built-in pin power dehomogenization strategy in SE2-ANL. Beyond the thermal hydraulic calculation, the SE2RCT code provides detailed axial distributions of the RCT calculated results. SE2RCT also calculates the the axial distribution of pin wise DPA for the cladding materials which is part of the FIPD calculated results. This report serves as the user manual for SE2RCT and thus eliminates the QA gap of missing documentation on the SE2RCT software. All of the features and limitations of SE2RCT are documented in this report. The input and output specifications of SE2RCT are discussed in detail, and some unique features of SE2RCT, e.g. accurate pin power and temperature results for problems with non-uniform composition within an assembly, are also demonstrated and tested.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Essence of Cryptol: A Denotational Cryptol Interpreter in Coq for Foundational Assurances for Quantum Resistant Cryptosystems

Systems of the utmost consequence need a means to establish authenticity of software and data. Cryptosystems implement authentication, but can be vulnerable to cryptographic and implementation attacks. With the threat of quantum cryptographic attacks, “post-quantum” cryptosystems (PQCs) must be henceforth used in these systems. However, the new cryptography needs new ways to, rigorously and machine-checkably, prove systems free of vulnerabilities. We propose a retargetable capability to rapidly instantiate proven correct postquantum cryptosystems through novel proof-carrying synthesis and proof-automation technique, extending those proven successful on existing systems. This capability is crucial to meeting the cryptographic requirements for future high-consequence systems. Since specifications for high consequence cryptography are presently captured in a domain specific language known as Cryptol. While this can enable convenient fully automated reasoning about Cryptol specificaitons and implementations via the Software Analysis Workbench (SAW), Cryptol has expressivity gaps, so that cryptosystems with probabilistic programming features like Falcon cannot be fully expressed in the language. Moreover, SAW’s automation fails for programs and specificaitons with inductive and recursive structure, as in the Sphincs+ PQC. Finally, Cryptol and SAW together represent some 200,000 lines of unverified Haskell, so that the any guarantees about high consequence cryptography are presently contingent on a large, unverified, yet trusted computing base. The first step of the larger project of agile, assured crpytography is therefore to provide a formal, mechanized semantics for Cryptol, so that the specifications expressed by cryptographers in Cryptol can be reasoned about and compiled into performant implementations with a foundational, machine checkable certificate of correctness. This report describes our work on this first step, culminating in the design of a certified denotational interpreter, in Coq, for core Cryptol.

97 MATHEMATICS AND COMPUTING↗

Calibration of multisite raters for prospective visual reads of amyloid PET scans

Abstract INTRODUCTION In multicenter Alzheimer's disease studies, amyloid positron emission tomography (PET) visual reads are typically performed centrally by a few experts. Incorporating a broader reader network enhances scalability and generalizability. METHODS Ten neuroimaging experts from eight Alzheimer's Disease Research Centers (ADRCs) visually read 180 amyloid PET scans (30 scans and 15 duplicate scans for each of four tracers, imaged across a wide variety of scanners), using preferred reading software without anatomical imaging or quantitation. Scans were classified as elevated or non‐elevated per tracer‐specific criteria. Inter‐ and intra‐rater agreement was assessed. RESULTS Inter‐rater agreement was substantial (Fleiss’κ = 0.78), with full consensus on 69% of scans. Inter‐rater reliability was substantial to perfect across tracers (Fleiss’κ = 0.70–0.87). Intra‐rater agreement was substantial to perfect (Cohen'sκ = 0.79‐1). Scans with intermediate (10–40 Centiloid) quantitation had lower reader agreement. DISCUSSION A multicenter expert network achieved substantial agreement classifying amyloid PET scans. These scans provide a standard for reader training and reliability assurance in future studies. Highlights Calibration methods ensure reliable amyloid positron emission tomography (PET) visual reads across multiple raters. Substantial agreement is possible across readers using their preferred tools. Agreement is also substantial regardless of the amyloid PET tracer used. Scans with intermediate (10–40 Centiloid) quantitation have lower reader agreement. The calibration set will become a training tool for amyloid PET visual read studies.

Neurosciences & Neurology↗

Feasibility Study of Needle Placement in Percutaneous Vertebroplasty: Cone-Beam Computed Tomography Guidance Versus Conventional Fluoroscopy

ObjectiveTo investigate the accuracy, procedure time, fluoroscopy time, and dose area product (DAP) of needle placement during percutaneous vertebroplasty (PVP) using cone-beam computed tomography (CBCT) guidance versus fluoroscopy.Materials and MethodsOn 4 spine phantoms with 11 vertebrae (Th7-L5), 4 interventional radiologists (2 experienced with CBCT guidance and two inexperienced) punctured all vertebrae in a bipedicular fashion. Each side was randomization to either CBCT guidance or fluoroscopy. CBCT guidance is a sophisticated needle guidance technique using CBCT, navigation software, and real-time fluoroscopy. The placement of the needle had to be to a specific target point. After the procedure, CBCT was performed to determine the accuracy, procedure time, fluoroscopy time, and DAP. Analysis of the difference between methods and experience level was performed.ResultsMean accuracy using CBCT guidance (2.61 mm) was significantly better compared with fluoroscopy (5.86 mm) (p < 0.0001). Procedure time was in favor of fluoroscopy (7.39 vs. 10.13 min; p = 0.001). Fluoroscopy time during CBCT guidance was lower, but this difference is not significant (71.3 vs. 95.8 s; p = 0.056). DAP values for CBCT guidance and fluoroscopy were 514 and 174 mGy cm{sup 2}, respectively (p < 0.0001). There was a significant difference in favor of experienced CBCT guidance users regarding accuracy for both methods, procedure time of CBCT guidance, and added DAP values for fluoroscopy.ConclusionCBCT guidance allows users to perform PVP more accurately at the cost of higher patient dose and longer procedure time. Because procedural complications (e.g., cement leakage) are related to the accuracy of the needle placement, improvements in accuracy are clinically relevant. Training in CBCT guidance is essential to achieve greater accuracy and decrease procedure time/dose values.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Geospatial Visualization of Global Satellite Images with Vis-EROS

The Earth Resources Observation and Science (EROS) Center of U.S. Geological Survey is currently managing and maintaining the world largest satellite images distribution system, which provides 24/7 free download service for researchers all over the globe in many areas such as Geology, Hydrology, Climate Modeling, and Earth Sciences. A large amount of geospatial data contained in satellite images maintained by EROS is generated every day. However, this data is not well utilized due to the lack of efficient data visualization tools. This software implements a method for visualizing various characteristics of the global satellite image download requests. More specifically, Keyhole Markup Language (KML) files are generated which can be loaded into an earth browser such as Google Earth. Colored rectangles associated with stored satellite scenes are painted onto the earth browser; and the color and opacity of each rectangle is varied as a function of the popularity of the corresponding satellite image. An analysis of the geospatial information obtained relative to specified time constraints provides an ability to relate image download requests to environmental, political, and social events.

54 ENVIRONMENTAL SCIENCES↗

A scalable nonlinear fluid–structure interaction solver based on a Schwarz preconditioner with isogeometric unstructured coarse spaces in 3D

Nonlinear fluid-structure interaction (FSI) problems on unstructured meshes in 3D appear many applications in science and engineering, such as vibration analysis of aircrafts and patient-specific diagnosis of cardiovascular diseases. In this work, we develop a highly scalable, parallel algorithmic and software framework for FSI problems consisting of a nonlinear fluid system and a nonlinear solid system, that are coupled monolithically. The FSI system is discretized by a stabilized finite element method in space and a fully implicit backward difference scheme in time. To solve the large, sparse system of nonlinear algebraic equations at each time step, we propose an inexact Newton-Krylov method together with a multilevel, smoothed Schwarz preconditioner with isogeometric coarse meshes generated by a geometry preserving coarsening algorithm. Here ''geometry'' includes the boundary of the computational domain and the wet interface between the fluid and the solid. We show numerically that the proposed algorithm and implementation are highly scalable in terms of the number of linear and nonlinear iterations and the total compute time on a supercomputer with more than 10,000 processor cores for several problems with hundreds of millions of unknowns.

97 MATHEMATICS AND COMPUTING↗

Thermo-economic analysis of high-temperature sensible thermal storage with different ternary eutectic alkali and alkaline earth metal chlorides

Molten salt mixtures with alkali and alkaline earth metal chlorides were developed for high-temperature sensible thermal energy storage in support of concurrent efforts to develop high-temperature advanced power cycles for concentrating solar power applications. Four ternary chloride mixtures with different cation combinations (Na, K, Li, Mg) were designed using the FactSage® software, and for three of these, the eutectic point was experimentally validated by differential scanning calorimetry. Specific heat capacity measurements were conducted following the ASTM E1269 standard, and were measured between 1.18 J/g/K and 1.31 J/g/K. The mass loss of the molten chloride salts was studied under three different gas blankets of nitrogen, argon and air by thermogravimetric analysis. All the selected salt mixtures were stable up to 700 degrees C, although weight loss due to vaporisation becomes significant around this temperature due to the high vapour pressure of the chloride salt mixtures. However, it is expected that operation at a temperature up to around 750 degrees C will be feasible in a closed system with an inert environment. Additionally, removal of chemically-bonded water and salt purification may need to be considered for extending the operating temperature. In terms of economic performance, although the inclusion of LiCl in the ternary eutectic mixtures is advantageous for reducing melting point and increasing specific heat capacity, at current costs, these benefits are unlikely to be justified unless LiCl cost reduces by a factor of three. As a result, the NaCl-KCl-MgCl 2 mixture has the lowest cost per unit energy stored, at 4.5 USD/kWh.

25 ENERGY STORAGE↗

Advancing Terrestrial Ecosystem Science With a Novel Automated Measurement System for Sun‐Induced Chlorophyll Fluorescence for Integration With Eddy Covariance Flux Networks

Abstract Sun‐induced chlorophyll fluorescence (SIF) provides critical information on the dynamics of gross primary productivity, a unique role not readily achievable using other methods. Long‐term continuous SIF observations have the potential to advance terrestrial ecosystem science. Realizing this potential, however, requires synergistic implementation of SIF measurements within eddy covariance (EC) flux networks. There is a need for SIF systems that can integrate seamlessly with EC instrumentation to maximize synergistic use of obtained data. Here we introduce the Fluorescence Auto‐Measurement Equipment (FAME) and protocol that fulfill such a purpose. FAME is designed specifically for plug‐and‐play integration with existing EC data acquisition systems. Its innovative hardware and software designs provide versatility, extensibility, autonomous operation, and ease of maintenance for acquiring SIF data of high quality and quantity. A major novel feature of FAME is its synchronized sampling of spectral irradiance and environmental variables, allowing for more precise interpretation of the SIF signal. FAME has been deployed since September 2016 at the Missouri Ozark AmeriFlux site, providing high‐quality measurements even when air temperatures approached 40 °C. Results reveal that canopy SIF saturated or even slightly decreased at high light, similar to leaf‐level photosynthesis. Clear diurnal hysteresis was observed: For the same light, morning SIF was higher than afternoon. Dynamic energy dissipation processes and stress‐induced movements of chloroplasts and leaves may explain the observed pattern. The technology and measurement protocol introduced here advances the coordinated observation of SIF and EC fluxes and represents a step change in observational ecosystem and carbon cycle science research.

54 ENVIRONMENTAL SCIENCES↗

Information flow for security in control systems

This paper considers the development of information flow analyses to support resilient design and active detection of adversaries in cyber physical systems (CPS). CPS security, though well studied, suffers from fragmentation. In this paper, we consider control systems as an abstraction of CPS. Here, we use information flow analysis, a well established set of methods developed in software security, to obtain a unified framework that captures and extends results in control system security. Specifically, we propose the Kullback Liebler (KL) divergence as a causal measure of information flow, which quantifies the effect of adversarial inputs on sensor outputs. We show that the proposed measure characterizes the resilience of control systems to specific attack strategies by relating the KL divergence to optimal detection. We then relate information flows to stealthy attack scenarios where an adversary can bypass detection. Finally, this article examines active detection mechanisms where a defender intelligently manipulates control inputs or the system itself to elicit information flows from an attacker's malicious behavior. In all previous cases, we demonstrate an ability to investigate and extend existing results through the proposed information flow analyses.

Weerakkody, Sean↗

Supply Chain Risk Management: Data Structuring

Supply chain risk management (SCRM) is an area of research that addresses both logistics concepts to maximize efficiency, reliability, and revenue as well as risk features, such as potential weak points, break points, and vulnerabilities within the supply chain. SCRM is used to find risks introduced at each node in a supply chain and how these risks can impact a company’s products, individuals, customers, and reputation. SCRM is a relatively new field, so standardized processes including data structuring are not fully documented. This paper explains the importance of a standard data structuring methodology and how it can enhance current SCRM efforts. Data ingest, structuring, and analysis are predominantly managed by humans. Automating some of the less complex steps can positively impact SCRM by allowing human analysts to focus on more strategic analyses. Types of data to be collected and structured are collected via publicly available information related to hardware, software, and corporate entities. After the data has been collected, the information is formatted in a specific manner, conforming to a schema, to allow for more effective and efficient ingest for further analysis. This paper outlines data structures used by Pacific Northwest National Laboratory for SCRM research and analysis purposes. These structures have been used for hundreds of analyses and have been successful in developing a common baseline. Data structuring is one of the first steps in data standardization, which will further mature and enhance the SCRM research area.

supply chain risk management, data structuring, re↗

SU-F-T-619: Dose Evaluation of Specific Patient Plans Based On Monte Carlo Algorithm for a CyberKnife Stereotactic Radiosurgery System

Purpose: This study will use Monte Carlo to simulate the Cyberknife system, and intend to develop the third-party tool to evaluate the dose verification of specific patient plans in TPS. Methods: By simulating the treatment head using the BEAMnrc and DOSXYZnrc software, the comparison between the calculated and measured data will be done to determine the beam parameters. The dose distribution calculated in the Raytracing, Monte Carlo algorithms of TPS (Multiplan Ver4.0.2) and in-house Monte Carlo simulation method for 30 patient plans, which included 10 head, lung and liver cases in each, were analyzed. The γ analysis with the combined 3mm/3% criteria would be introduced to quantitatively evaluate the difference of the accuracy between three algorithms. Results: More than 90% of the global error points were less than 2% for the comparison of the PDD and OAR curves after determining the mean energy and FWHM.The relative ideal Monte Carlo beam model had been established. Based on the quantitative evaluation of dose accuracy for three algorithms, the results of γ analysis shows that the passing rates (84.88±9.67% for head,98.83±1.05% for liver,98.26±1.87% for lung) of PTV in 30 plans between Monte Carlo simulation and TPS Monte Carlo algorithms were good. And the passing rates (95.93±3.12%,99.84±0.33% in each) of PTV in head and liver plans between Monte Carlo simulation and TPS Ray-tracing algorithms were also good. But the difference of DVHs in lung plans between Monte Carlo simulation and Ray-tracing algorithms was obvious, and the passing rate (51.263±38.964%) of γ criteria was not good. It is feasible that Monte Carlo simulation was used for verifying the dose distribution of patient plans. Conclusion: Monte Carlo simulation algorithm developed in the CyberKnife system of this study can be used as a reference tool for the third-party tool, which plays an important role in dose verification of patient plans. This work was supported in part by the grant from Chinese Natural Science Foundation (Grant No. 11275105). Thanks for the support from Accuray Corp.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-JeP1-04: Deformable Image Registration Performances in Pelvis Patients: Impact of CBCT Image Quality

Purpose: To investigate the accuracy and robustness, against image noise and artifacts (typical of CBCT images), of a commercial algorithm for deformable image registration (DIR), to propagate regions of interest (ROIs) in computational phantoms based on real prostate patient images. Methods: The Anaconda DIR algorithm, implemented in RayStation was tested. Two specific Deformation Vector Fields (DVFs) were applied to the reference data set (CTref) using the ImSimQA software, obtaining two deformed CTs. For each dataset twenty-four different level of noise and/or capping artifacts were applied to simulate CBCT images. DIR was performed between CTref and each deformed CTs and CBCTs. In order to investigate the relationship between image quality parameters and the DIR results (expressed by a logit transform of the Dice Index) a bilinear regression was defined. Results: More than 550 DIR-mapped ROIs were analyzed. The Statistical analysis states that deformation strenght and artifacts were significant prognostic factors of DIR performances, while noise appeared to have a minor role in DIR process as implemented in RayStation as expected by the image similarity metric built in the registration algorithm. Capping artifacts reveals a determinant role for the accuracy of DIR results. Two optimal values for capping artifacts were found to obtain acceptable DIR results (DICE> 075/ 0.85). Various clinical CBCT acquisition protocol were reported to evaluate the significance of the study. Conclusion: This work illustrates the impact of image quality on DIR performance. Clinical issues like Adaptive Radiation Therapy (ART) and Dose Accumulation need accurate and robust DIR software. The RayStation DIR algorithm resulted robust against noise, but sensitive to image artifacts. This result highlights the need of robustness quality assurance against image noise and artifacts in the commissioning of a DIR commercial system and underlines the importance to adopt optimized protocols for CBCT image acquisitions in ART clinical implementation.

60 APPLIED LIFE SCIENCES↗

Q Framework

The Q Formal Analysis Framework is a set of software tools used to formally prove that implementations of high-consequence digital systems meet mathematical specifications. The tools are designed to work together as a set. Specifications are derived directly from high-level requirements and expressed in the QSpec hierarchical state machine format. The toolkit includes QSpec, QRefact, and QReqs. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. SAND2021-0504 O

Hulette, GeoffreyC.↗

Pando

SAND2025-02006O Pando is a distributed data analysis software tool. It is designed to handle large-scale graph analysis problems, often with a specific focus on blockchain/cryptocurrency data. Pando handles scalability by running on a distributed cluster of servers. Users can customize the output using the program’s plugin/extension design methodology. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Gabert, Kasimir↗

ROBOT: A Tool for Automating Ontology Workflows

BACKGROUND:Ontologies are invaluable in the life sciences, but building and maintaining ontologies often requires a challenging number of distinct tasks such as running automated reasoners and quality control checks, extracting dependencies and application-specific subsets, generating standard reports, and generating release files in multiple formats. Similar to more general software development, automation is the key to executing and managing these tasks effectively and to releasing more robust products in standard forms. For ontologies using the Web Ontology Language (OWL), the OWL API Java library is the foundation for a range of software tools, including the Protégé ontology editor. In the Open Biological and Biomedical Ontologies (OBO) community, we recognized the need to package a wide range of low-level OWL API functionality into a library of common higher-level operations and to make those operations available as a command-line tool. RESULTS:ROBOT (a recursive acronym for "ROBOT is an OBO Tool") is an open source library and command-line tool for automating ontology development tasks. The library can be called from any programming language that runs on the Java Virtual Machine (JVM). Most usage is through the command-line tool, which runs on macOS, Linux, and Windows. ROBOT provides ontology processing commands for a variety of tasks, including commands for converting formats, running a reasoner, creating import modules, running reports, and various other tasks. These commands can be combined into larger workflows using a separate task execution system such as GNU Make, and workflows can be automatically executed within continuous integration systems. CONCLUSIONS:ROBOT supports automation of a wide range of ontology development tasks, focusing on OBO conventions. It packages common high-level ontology development functionality into a convenient library, and makes it easy to configure, combine, and execute individual tasks in comprehensive, automated workflows. This helps ontology developers to efficiently create, maintain, and release high-quality ontologies, so that they can spend more time focusing on development tasks. It also helps guarantee that released ontologies are free of certain types of logical errors and conform to standard quality control checks, increasing the overall robustness and efficiency of the ontology development lifecycle.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

An automated framework for NMR chemical shift calculations of small organic molecules

When using nuclear magnetic resonance (NMR) to assist in chemical identification in complex samples, researchers commonly rely on databases for chemical shift spectra. However, authentic standards are typically depended upon to build libraries experimentally. Considering complex biological samples, such as blood and soil, the entirety of NMR spectra required for all possible compounds would be infeasible to ascertain due to limitations of available standards and experimental processing time. As an alternative, we introduce the in silico Chemical Library Engine (ISiCLE) NMR chemical shift module to accurately and automatically calculate NMR chemical shifts of small organic molecules through use of quantum chemical calculations. ISiCLE performs density functional theory (DFT)-based calculations for predicting chemical properties - specifically NMR chemical shifts in this manuscript - via the open source, high-performance omputational chemistry software, NWChem. ISiCLE calculates the NMR chemical shifts of sets of molecules using any available combination of DFT method, solvent, and NMR-active nuclei, using both user-selected reference compounds and/or linear regression methods. Calculated NMR chemical shifts are provided to the user for each molecule, along with comparisons with respect to a number of metrics commonly used in the literature. Here, we demonstrate ISiCLE using a set of 312 molecules, ranging in size up to 90 carbon atoms. For each, calculation of NMR chemical shifts have been performed with 8 different levels of DFT theory, and with solvation effects using the implicit solvent Conductor-like Screening Model (COSMO). The DFT method dependence of the calculated chemical shifts have been systematically investigated through benchmarking and subsequently compared to experimental data available in the literature. Furthermore, ISiCLE has been applied to a set of 80 methylcyclohexane conformers, combined via Boltzmann weighting and compared to experimental values. We demonstrate that our protocol shows promise in the automation of chemical shift calculations and, ultimately, the expansion of chemical shift libraries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutronics Studies of Uranium-bearing Fully Ceramic Micro-encapsulated Fuel for PWRs

Our study evaluated the neutronics and some of the fuel cycle characteristics of using uranium-based fully ceramic microencapsulated (FCM) fuel in a pressurized water reactor (PWR). Specific PWR lattice designs with FCM fuel have been developed that are expected to achieve higher specific burnup levels in the fuel while also increasing the tolerance to reactor accidents. The SCALE software system was the primary analysis tool used to model the lattice designs. A parametric study was performed by varying tristructural isotropic particle design features (e.g., kernel diameter, coating layer thicknesses, and packing fraction) to understand the impact on reactivity and resulting operating cycle length. Moreover, to match the lifetime of an 18-month PWR cycle, the FCM particle fuel design required roughly 10% additional fissile material at beginning of life compared with that of a standard uranium dioxide (UO 2 ) rod. Uranium mononitride proved to be a favorable fuel for the fuel kernel due to its higher heavy metal loading density compared with UO 2 . The FCM fuel designs evaluated maintain acceptable neutronics design features for fuel lifetime, lattice peaking factors, and nonproliferation figure of merit.

10 SYNTHETIC FUELS↗

GATOS Operator's Manual

This document contains information needed to operate the GATOS (GAs Transfer Operations Station) data acquisition and control system. It does not stand alone; the "GATOS System Overview" document should be read first and the following manuals should be read as needed: "GATOS Software Manual" for details of the software design. "GATOS Hardware Manual" for details of the hardware design. Various manufacturers' hardware manuals for specific device information.

97 MATHEMATICS AND COMPUTING↗