Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99

Development of ac corona discharge modes at atmospheric pressure

Corona discharges in gases exist under several distinctive forms. In this paper, a survey study has been made of ac corona discharge modes generated in some different gases fed in a wire-duct reactor with a constant rate of flowing at atmospheric pressure. The properties of different corona modes are analyzed under some condition transitions from Trichel pulses to a steady glow. In the course of the presented experimental work, numerous apparent contradictions with earlier observations necessitated further study and are given to provide more information on the physical mechanisms of the ac corona discharges. Furthermore, we have gained insight into some new technologies and applications of the environmentally friendly corona and plasma discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectral-domain phase microscopy with improved sensitivity using two-dimensional detector arrays

In this work we demonstrate the use of two-dimensional detectors to improve the signal-to-noise ratio (SNR) and sensitivity in spectral-domain phase microscopy for subnanometer accuracy measurements. We show that an increase in SNR can be obtained, from 82 dB to 105 dB, using 150 pixel lines of a low-cost CCD camera as compared to a single line, to compute an averaged axial scan. In optimal mechanical conditions, phase stability as small as 92 {mu}rad, corresponding to 6 pm displacement accuracy, could be obtained. We also experimentally demonstrate the benefit of spatial-averaging in terms of the reduction of signal fading due to an axially moving sample. The applications of the improved system are illustrated by imaging live cells in culture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reduction of frequency noise and frequency shift by phase shifting elements in frequency modulation atomic force microscopy

We recently reported the analysis of the frequency noise in the frequency modulation atomic force microscopy (FM-AFM) both in high-Q and low-Q environments [Rev. Sci. Instrum. 80, 043708 (2009)]. We showed in the paper that the oscillator noise, the frequency fluctuation of the oscillator, becomes prominent in the modulation frequency lower than f{sub 0}/2Q, where f{sub 0} and Q are the resonance frequency and Q-factor. The magnitude of the oscillator noise is determined by the slope of the phase versus frequency curve of the cantilever at f{sub 0}. However, in actual FM-AFM in liquids, the phase versus frequency curve may not be always ideal because of the existence of various phase shifting elements (PSEs). For example, the spurious resonance peaks caused by the acoustic excitation and a band-pass filter in the self-oscillation loop increase the slope of the phase versus frequency curve. Due to those PSEs, the effective Q-factor is often increased from the intrinsic Q-factor of the cantilever. In this article, the frequency noise in the FM-AFM system with the PSEs in the self-oscillation loop is analyzed to show that the oscillator noise is reduced by the increase of the effective Q-factor. It is also shown that the oscillation frequency deviates from the resonance frequency due to the increase of the effective Q-factor, thereby causing the reduction in the frequency shift signal with the same factor. Therefore the increase of the effective Q-factor does not affect the signal-to-noise ratio in the frequency shift measurement, but it does affect the quantitativeness of the measured force in the FM-AFM. Furthermore, the reduction of the frequency noise and frequency shift by the increase of the effective Q-factor were confirmed by the experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An accurate symplectic calculation of the inboard magnetic footprint from statistical topological noise and field errors in the DIII-D

Any canonical transformation of Hamiltonian equations is symplectic, and any area-preserving transformation in 2D is a symplectomorphism. Based on these, a discrete symplectic map and its continuous symplectic analog are derived for forward magnetic field line trajectories in natural canonical coordinates. The unperturbed axisymmetric Hamiltonian for magnetic field lines is constructed from the experimental data in the DIII-D [J. L. Luxon and L. E. Davis, Fusion Technol. 8, 441 (1985)]. The equilibrium Hamiltonian is a highly accurate, analytic, and realistic representation of the magnetic geometry of the DIII-D. These symplectic mathematical maps are used to calculate the magnetic footprint on the inboard collector plate in the DIII-D. Internal statistical topological noise and field errors are irreducible and ubiquitous in magnetic confinement schemes for fusion. It is important to know the stochasticity and magnetic footprint from noise and error fields. The estimates of the spectrum and mode amplitudes of the spatial topological noise and magnetic errors in the DIII-D are used as magnetic perturbation. The discrete and continuous symplectic maps are used to calculate the magnetic footprint on the inboard collector plate of the DIII-D by inverting the natural coordinates to physical coordinates. The combination of highly accurate equilibrium generating function, natural canonical coordinates, symplecticity, and small step-size together gives a very accurate calculation of magnetic footprint. Radial variation of magnetic perturbation and the response of plasma to perturbation are not included. The inboard footprint from noise and errors are dominated by m=3, n=1 mode. The footprint is in the form of a toroidally winding helical strip. The width of stochastic layer scales as (1/2) power of amplitude. The area of footprint scales as first power of amplitude. The physical parameters such as toroidal angle, length, and poloidal angle covered before striking, and the safety factor all have fractal structure. The average field diffusion near the X-point for lines that strike and that do not strike differs by about three to four orders of magnitude. The magnetic footprint gives the maximal bounds on size and heat flux density on collector plate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pencil lead plasma for generating multimicrojoule high-order harmonics with a broad spectrum

Using the plasma harmonic method, we show the generation of efficient and intense high-order harmonics from plasma of pencil lead. We demonstrate multimicrojoule energy in each harmonic order for the 11th to the 17th order of a Ti:sapphire laser. By analyzing the target morphology and the plasma composition, we conclude that these intense harmonics are generated from nanoparticles of graphitic carbon.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microfabricated atomic vapor cell arrays for magnetic field measurements

We describe a method for charging atomic vapor cells with cesium and buffer gas. By this, it is possible to adjust the buffer gas pressure in the cells with good accuracy. Furthermore, we present a new design of microfabricated vapor cell arrays, which combine silicon wafer based microfabrication and ultrasonic machining to achieve the arrays of thermally separated cells with 50 mm{sup 3} volume. With cells fabricated in the outlined way, intrinsic magnetic field sensitivities down to 300 fT/Hz{sup 1/2} are reached.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration method to characterize the accuracy of phase-shifting point diffraction interferometer

Characterization of measurement accuracy of the phase-shifting point diffraction interferometer (PS/PDI) is usually performed by two-pinhole null test. In this procedure, the geometrical coma and detector tilt astigmatism systematic errors are almost one or two magnitude higher than the desired accuracy of PS/PDI. These errors must be accurately removed from the null test result to achieve high accuracy. Published calibration methods, which can remove the geometrical coma error successfully, have some limitations in calibrating the astigmatism error. In this paper, we propose a method to simultaneously calibrate the geometrical coma and detector tilt astigmatism errors in PS/PDI null test. Based on the measurement results obtained from two pinhole pairs in orthogonal directions, the method utilizes the orthogonal and rotational symmetry properties of Zernike polynomials over unit circle to calculate the systematic errors introduced in null test of PS/PDI. The experiment using PS/PDI operated at visible light is performed to verify the method. The results show that the method is effective in isolating the systematic errors of PS/PDI and the measurement accuracy of the calibrated PS/PDI is 0.0088{lambda} rms ({lambda}= 632.8 nm).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solitary waves of laser pulse in a plasma channel

The propagation of a Gaussian laser pulse in a preformed plasma channel is investigated. The conditions for the existence of electromagnetic solitary waves are obtained theoretically by analyzing the differential equation of the pulse spot size including the effects of relativistic self-focusing, ponderomotive self-channeling, and preformed channel focusing. Some solitarylike wave solutions are presented numerically and their possible implications on laser-plasma acceleration are discussed briefly.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma absorption effects on collisions of positively charged dust grains in dusty plasmas

The plasma absorption effects on the collisions of positively charged dust grains are investigated in dusty plasmas. The method of stationary phase and the effective interaction potential containing the attractive part are employed to obtain the scattering cross-section between a pair of positively charged dust grains as a function of the impact parameter, collision energy, electron and ion temperatures, and Debye length. The result shows that the plasma absorption effects on the dust surface strongly suppress the total scattering cross-section. It is also shown that the plasma absorption effects on the scattering cross-section decrease with an increase of the ratio of the electron temperature to the ion temperature. In addition, the plasma absorption effects are found to be decreased with increasing the collision velocity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The effect of excitation wavelength on dynamics of laser-produced tin plasma

We investigated the effect of the excitation wavelength on the density evolution of laser-produced tin plasmas, both experimentally and numerically. For producing plasmas, Sn targets were excited with either 10.6 {mu}m CO{sub 2} laser or 1.06 {mu}m Nd:yttrium aluminum garnet laser; both are considered to be potential excitation lasers for extreme ultraviolet lithography laser-produced plasma light sources. The electron density of the plasma during the isothermal expansion regime was estimated using an interferometric technique. The Stark broadening of isolated singly-ionized emission was employed for deducing the density during the plasma adiabatic expansion regime. Our results indicate that the excitation source wavelength determines the initial density of the plasma, as well the plume expansion dynamics. Numerical simulation using HEIGHTS simulation package agrees well with the experimentally measured density profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Regularized Grad equations for multicomponent plasmas

The moment method of Grad is used to derive macroscopic conservation equations for multicomponent plasmas for small and moderate Knudsen numbers, accounting for the electromagnetic field influence and thermal nonequilibrium. In the low Knudsen number limit, the equations derived are fully consistent with those obtained by means of the Chapman-Enskog method. In particular, we have retieved the Kolesnikov effect coupling electrons and heavy particles in the case of the Boltzmann moment systems. Finally, a regularization procedure is proposed to achieve continuous shock structures at all Mach numbers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PIC-MCC Simulations of Capacitive RF Discharges for Plasma Etching

A numerical study of parallel-plate rf discharges in Ar has been performed including the transport of ions and electrons in the sheath on the substrate. We employ a two-dimensional particle-in-cell with Monte Carlo collisions (PIC/MCC) method for an asymmetric capacitive discharge with an external electrical circuit containing a blocking capacitor and an rf power supply. The model gives self-consistently the dc self-bias voltages that usually occur on the rf-powered electrode, along with the energy and angular distribution of ion and electron fluxes incident on substrate surfaces. The peak electron density obtained in the discharge is 5.0x10{sup 8} cm{sup -3} at the Ar gas pressure of 20 mTorr, rf frequency of 13.56 MHz, and rf voltage of 100 V, where the dc self-bias voltage is determined to be -60 V. For the range of rf voltage (50-400 V) and frequency (13.56-40.68 MHz) examined, the peak electron density increases linearly with rf voltage and frequency squared. Higher rf frequency leads to larger distribution at lower incident angle of ions (more normal to the substrate surface), so that more desirable angular distribution is obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The spatiotemporal oscillation characteristics of the dielectric wall sheath in stationary plasma thrusters

A two-dimensional particle in cell model is used to simulate the sheath oscillation in stationary plasma thrusters. The embedded secondary electron emission (SEE) submodel is based on that of Morozov but improved by considering the electron elastic reflection effect. The simulation results show that when the SEE coefficient is smaller than one due to the relative low electron temperature, one-dimensional static sheath can be found; as the electron temperature increase, the SEE coefficient approaches to one and temporal oscillation sheath appears; when the electron temperature increases so high that the SEE coefficient is beyond one, the sheath oscillates not only in time but also in space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Response to ''Comment on 'Scalings for radiation from plasma bubbles''' [Phys. Plasmas 18, 034701 (2011)]

In the preceding Comment, Corde, Stordeur, and Malka claim that the trapping threshold derived in my recent paper is incorrect. Their principal argument is that the elliptical orbits I used are not exact solutions of the equation of motion in the fields of the bubble. The original paper never claimed this--rather I claimed that the use of elliptical orbits was a reasonable approximation, which I based on observations from particle-in-cell simulations. Integration of the equation of motion for analytical expressions for idealized bubble fields (either analytically [I. Kostyukov, E. Nerush, A. Pukhov, and V. Seredov, Phys. Rev. Lett. 103, 175003 (2009)] or numerically [S. Corde, A. Stordeur, and V. Malka, ''Comment on 'Scalings for radiation from plasma bubbles,' '' Phys. Plasmas 18, 034701 (2011)]) produces a trapping threshold wholly inconsistent with experiments and full particle-in-cell (PIC) simulations (e.g., requiring an estimated laser intensity of a{sub 0{approx}}30 for n{sub e{approx}}10{sup 19} cm{sup -3}). The inconsistency in the particle trajectories between PIC and the numeric model used by the comment authors arises due to the fact that the analytical fields are only approximately true for ''real'' plasma bubbles, and lack certain key features of the field structure. Two possible methods of resolution to this inconsistency are either to find ever more complicated but accurate models for the bubble fields or to find approximate solutions to the equations of motion that capture the essential features of the self-consistent electron trajectories. The latter, heuristic approach used in my recent paper produced a threshold that is better matched to experimental observations. In this reply, I will also revisit the problem and examine the relationship between bubble radius and electron momentum at the point of trapping without reference to a particular trajectory.

43 PARTICLE ACCELERATORS↗

A new method for wideband characterization of resonator-based sensing platforms

A new approach to the electronic instrumentation for extracting data from resonator-based sensing devices (e.g., microelectromechanical, piezoelectric, electrochemical, and acoustic) is suggested and demonstrated here. Traditionally, oscillator-based circuitry is employed to monitor shift in the resonance frequency of the resonator. These circuits give a single point measurement at the frequency where the oscillation criterion is met. However, the resonator response itself is broadband and contains much more information than a single point measurement. Here, we present a method for the broadband characterization of a resonator using white noise as an excitation signal. The resonator is used in a two-port filter configuration, and the resonator output is subjected to frequency spectrum analysis. The result is a wideband spectral map analogous to the magnitude of the S21 parameters of a conventional filter. Compared to other sources for broadband excitation (e.g., frequency chirp, multisine, or narrow time domain pulse), the white noise source requires no design of the input signal and is readily available for very wide bandwidths (1 MHz-3 GHz). Moreover, it offers simplicity in circuit design as it does not require precise impedance matching; whereas such requirements are very strict for oscillator-based circuit systems, and can be difficult to fulfill. This results in a measurement system that does not require calibration, which is a significant advantage over oscillator circuits. Simulation results are first presented for verification of the proposed system, followed by measurement results with a prototype implementation. A 434 MHz surface acoustic wave (SAW) resonator and a 5 MHz quartz crystal microbalance (QCM) are measured using the proposed method, and the results are compared to measurements taken by a conventional bench-top network analyzer. Maximum relative differences in the measured resonance frequencies of the SAW and QCM resonators are 0.0004% and 0.002%, respectively. The ability to track a changing sensor response is demonstrated by inducing temperature variations and measuring resonance frequency simultaneously using the proposed technique in parallel with a network analyzer. The relative difference between the two measurements is about 5.53 ppm, highlighting the impressive accuracy of the proposed system. Using commercially available digital signal processors (DSPs), we believe that this technique can be implemented as a system-on-a-chip solution resulting in a very low cost, easy to use, portable, and customizable sensing system. In addition, given the simplicity of the signal and circuit design, and its immunity to other common interface concerns (injection locking, oscillator interference, and drift, etc.), this method is better suited to accommodating array-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Diagnosing femtosecond laser-solid interactions with monochromatic K{sub {alpha}} imager and x-ray pinhole camera

An x-ray pinhole camera and a monochromatic K{sub {alpha}} imager are used to measure the interactions of intense femtosecond laser pulses with Cu foil targets. The two diagnostics give different features in the spot size and the laser energy scaling, which are resulted from different physical processes. Under our experimental conditons, the K{sub {alpha}} emission is mainly excited by the fast electrons transporting inside the cold bulk target. In contrast, the x-ray pinhole signals are dominated by the broadband thermal x-ray emission from the hot plasma at the front target surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗